• Title/Summary/Keyword: Rotation Center

Search Result 976, Processing Time 0.039 seconds

The Comparison of Sphere Fitting Methods for Estimating the Center of Rotation on a Human Joint (인체관절의 회전중심 추정을 위한 구적합법의 비교)

  • Kim, Jin-Uk
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.1
    • /
    • pp.53-62
    • /
    • 2013
  • The methods of fitting a circle to measured data, geometric fit and algebraic fit, have been studied profoundly in various areas of science. However, they have not been applied exactly to a biomechanics discipline for locating the center of rotation of a human joint. The purpose of this study was to generalize the methods to fitting spheres to the points in 3-dimension, and to estimate the center of rotation of a hip joint by three of geometric fit methods(Levenberg-Marquardt, Landau, and Sp$\ddot{a}$th) and four of algebraic fit methods(Delogne-K${\aa}$sa, Pratt, Taubin, and Hyper). 1000 times of simulation experiments for flexion/extension and ad/abduction at an artificial hip joint with four levels of range of motion(10, 15, 30, and $60^{\circ}$) and three levels of angular velocity(30, 60, and $90^{\circ}$/s) were executed to analyze the responses of the estimated center of rotation. The results showed that the Sp$\ddot{a}$th estimate was very sensitive to the marker near the center of rotation. The bias of Delogne-K${\aa}$sa estimate existed in an even larger range of motion. The Levenberg-Marquardt algorithm of geometric fit and the Pratt of algebraic fit showed the best results. The combination of two methods, using the Pratt's estimate as initial values of the Levenberg-Marquardt algorithm, could be a candidate of more valid estimator.

Inference on the Joint Center of Rotation by Covariance Pattern Models

  • Kim, Jinuk
    • Korean Journal of Applied Biomechanics
    • /
    • v.28 no.2
    • /
    • pp.127-134
    • /
    • 2018
  • Objective: In a statistical linear model estimating the center of rotation of a human hip joint, which is the parameter related to the mean of response vectors, assumptions of homoscedasticity and independence of position vectors measured repeatedly over time in the model result in an inefficient parameter. We, therefore, should take into account the variance-covariance structure of longitudinal responses. The purpose of this study was to estimate the efficient center of rotation vector of the hip joint by using covariance pattern models. Method: The covariance pattern models are used to model various kinds of covariance matrices of error vectors to take into account longitudinal data. The data acquired from functional motions to estimate hip joint center were applied to the models. Results: The results showed that the data were better fitted using various covariance pattern models than the general linear model assuming homoscedasticity and independence. Conclusion: The estimated joint centers of the covariance pattern models showed slight differences from those of the general linear model. The estimated standard errors of the joint center for covariance pattern models showed a large difference with those of the general linear model.

Changes in Range of Motion after Intra-Articular Corticosteroid Injection in Frozen Shoulder: A Retrospective 3-Month Follow-Up Study (동결견 환자에서 관절강내 스테로이드 주사 후 관절가동범위의 변화)

  • Cho, Hyoung Jun;Yoon, Seung-Hyun;Kim, Minchul;Kim, Dae Hwan
    • Clinical Pain
    • /
    • v.18 no.2
    • /
    • pp.76-81
    • /
    • 2019
  • Objective: To examine (1) the degree of reduction of passive range of motion (PROM) on the affected side compared to that on the unaffected side and (2) the degree of increase in PROM following intra-articular corticosteroid injection (IACI) in patients with frozen shoulder. Method: The medical records of 120 patients with frozen shoulder were retrospectively reviewed. PROM of the unaffected and affected shoulder (flexion, extension, abduction, internal rotation, external rotation) was compared, and changes in PROM of the affected shoulder after a single IACI (triamcinolone 20 mg) were evaluated after 12 weeks. Results: At the time of diagnosis, PROM of the affected shoulder was most limited in external rotation, followed by internal rotation, abduction, extension, and flexion, compared to that of the unaffected shoulder. Compared to before IACI, PROM of external rotation demonstrated the greatest increase compared to all the other movements after IACI. Conclusion: Limitation in PROM of the frozen shoulder at the time of diagnosis was greatest for external rotation. Moreover, external rotation experienced the greatest improvement after IACI. Our findings should help to further clarify the clinical characteristics of frozen shoulder, aid in its diagnosis, and allow the prediction of the effects of IACI.

SIMULATION OF IMAGE DISTORTON AND ITS CORRECTION BY OBSERVER'S ROTATION MOVEMENT IN STEREOSCOPIC DISPLAY

  • Kim, Dong-Wook;Lee, Kwang-Hoon;Chang, Eun-Young;Kim, Jin-Woong;Kim, Sung-Kyu
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.360-363
    • /
    • 2009
  • Variation of viewing position of the observer is one of factors of image distortion in the stereoscopic display. A rotation movement of the observer makes the stereoscopic image distortion and that is caused by different horizontal position of each eye of the observer. It is different from horizontal and depth directional movement of the observer. In this paper, we showed the numerical simulation result about the distortion analysis and the correction of the stereoscopic image in rotation movement of the observer.

  • PDF

A Statistical Model for Marker Position in Biomechanics

  • Kim, Jinuk
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.1
    • /
    • pp.67-74
    • /
    • 2017
  • Objective: The purpose of this study was to apply a general linear model in statistics to marker position vectors used to study human joint rotational motion in biomechanics. Method: For this purpose, a linear model that represents the effect of the center of hip joint rotation and the rotation of the marker position on the response was formulated. Five male subjects performed hip joint functional motions, and the positions of nine markers attached on the thigh with respect to the pelvic coordinate system were acquired at the same time. With the nine marker positions, the center of hip joint rotation and marker positions on the thigh were estimated as parameters in the general linear model. Results: After examining the fitted model, this model did not fit the data appropriately. Conclusion: A refined model is required to take into account specific characteristics of longitudinal data and other covariates such as soft tissue artefacts.

Theoretical Derivation of the Optimum Rotation Speed of a Desiccant Rotor (이론적 방법에 의한 제습로터 최적 회전속도의 결정)

  • Lee, Dae-Young;Song, Gwi-Eun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.10
    • /
    • pp.575-582
    • /
    • 2009
  • The optimum rotation speed of a desiccant rotor is studied theoretically based on a theoretical solution to the heat and mass transfer processes in the desiccant rotor. A simple correlation equation for the optimum rotation speed is derived to show the effects of various parameters including the thermo-physical properties, the geometric dimension, and the operating condition of the desiccant rotor. The theoretical result is compared with existing experimental data to validate the linearization and simplification included in the solution procedure. Based on the theoretical solution, the effects of major parameters on the optimum rotation speed are studied and the fundamental mechanism of the influences is investigated.

Digital Image Stabilization Using Simple Estimation of Rotational and Translational Motion (회전 및 병진운동 추정을 통한 디지털 영상안정화)

  • Seok, Ho-Dong;Kang, Kil-Soon;Lyou, Joon
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.46-48
    • /
    • 2004
  • This paper presents a simple method of rotational and translational motion estimation for digital image stabilization. The scheme first computes the rotation center by taking least squares of selected local velocity vectors, and the rotational angle is found from special subset of motion vectors. And then translational motion can be estimated by the relation among movement of rotation center, rotation angle and translation movement. To show the effectiveness of our approach, the synthetic images are evaluated, resulting in better performance.

  • PDF

A Study on the Tappet Rotation in the Direct Acting Type OHC Valve Train System (직접 구동형 OHC 밸브 트레인 시스템의 태핏 회전에 관한 연구)

  • 한동철;김형준;조명래
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.286-291
    • /
    • 1998
  • The aim of this paper is to measure the tappet rotation in OHC valve train system. Tappet is eccentric from the cam center to rotate for preventing the partial wear. The experimental system is developed to measure the tappet rotation by using the laser beam and optical fiber. The characteristics of tappet rotation is presented for various operating conctitions. Specially, it is observed that tappet is rotated at the base circle.

  • PDF

Comparative analysis of internal flow characteristics of LBE-cooled fast reactor main coolant pump with different structures under reverse rotation accident conditions

  • Lu, Yonggang;Wang, Xiuli;Fu, Qiang;Zhao, Yuanyuan;Zhu, Rongsheng
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2207-2220
    • /
    • 2021
  • Lead alloy is used as coolant in Lead-based cooled Fast Reactor (LFR). The natural characteristics of lead alloy are combined with the simple structural design of LFR. This constitutes the inherent safety characteristics of LFR. The main work of this paper is to take the main coolant pump (MCP) in the lead-cooled fast reactor (LFR) as the research object, and to study the flow pattern distribution of the internal flow field under the reverse rotation pump condition, the reverse rotation positive-flow braking condition and the reverse rotation negative-flow braking condition. In this paper, the double-outlet volute type and the space guide vane are selected as the potential designs of the CLEAR-I MCP. In this paper, the CFD method is used to study the potential reverse accident of the MCP. It is found that the highest flow velocity in the impeller appears at the impeller outlet, and the Q-H curves of the two design programs basically coincide. The space guide vane type MCP has better hydraulic performance under the reverse rotation positive-flow condition, the Q-H curves of the two designs gradually separate with increasing flow rate, and the maximum flow velocity inside the space guide vane type MCP is obviously lower than that of the double-outlet volute type. For the reverse rotation test of MCP, only the condition of the forward rotating pump of the main coolant pump is tested and verified. For the simulation of the MCP in LBE medium, it proved that the turbulence model and basic settings selected in the simulation are reliable.