Objective: The purpose of this study was to apply a general linear model in statistics to marker position vectors used to study human joint rotational motion in biomechanics. Method: For this purpose, a linear model that represents the effect of the center of hip joint rotation and the rotation of the marker position on the response was formulated. Five male subjects performed hip joint functional motions, and the positions of nine markers attached on the thigh with respect to the pelvic coordinate system were acquired at the same time. With the nine marker positions, the center of hip joint rotation and marker positions on the thigh were estimated as parameters in the general linear model. Results: After examining the fitted model, this model did not fit the data appropriately. Conclusion: A refined model is required to take into account specific characteristics of longitudinal data and other covariates such as soft tissue artefacts.
Keywords
Marker; Hip joint; Center of rotation; General linear model;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 MacKinnon, J. G. & White, H. (1985). Some heteroskedasticity-consistent covariance matrix estimators with improved finite sample properties. Journal of Econometrics, 29, 305-325.   DOI
2 McCullagh, P. & Nelder, J. A. (1989). Generalized linear models (2nd ed.). Boca Raton, FL: Chapman & Hall/CRC.
3 McCulloch, C. E., Searle, S. R. & Neuhaus, J. M. (2008). Generalized, linear, and mixed models (2nd ed.). Hoboken, NJ: John Wiley & Sons, Inc.
4 Monahan, J. F. (2008). A primer on linear models. Boca Raton, FL: Chapman & Hall/CRC.
5 Ojeda, J., Martinez-Reina, J. & Mayo, J. (2014). A method to evaluate human skeletal models using marker residuals and global optimization. Machanism and Machine Theory, 73, 259-272.   DOI
6 Piazza, S. J., Erdemir, A., Okita, N. & Cavanagh, P. R. (2004). Assessment of the functional method of hip joint center location subject to reduced range of hip motion. Journal of Biomechanics, 37, 349-356.   DOI
7 Ravishanker, N. & Dey, D. K. (2002). A first course in linear model theory. Chapman & Hall/CRC.
8 Robinson, S. M. (1961). Fitting spheres by the method of least squares. Communications of the ACM, 4, 491.   DOI
9 Siston, R. A. & Delp, S. L. (2006). Evaluation of a new algorithm to determine the hip joint center. Journal of Biomechanics, 39, 125-130.   DOI
10 Delogne, P. (1972). Computer optimization of Deschamp' method and error cancellation reflectometry. Proceedings of the IMEKO-Symposium on Microwave Measurement, Bupapest, 117-129.
11 Spath, H. (1998). Least-square fitting spheres. Journal of Optimization Theory and Applications, 96, 191-199.   DOI
12 Taylor, J. R. (1997). An introduction to error analysis: The study of uncertainties in physical measurements (2nd ed.). University Science Books.
13 Wu, G., Siegler, S., Allard, P., Kirtley, C., Leardini, A., Rosenbaum, D., . . . Stokes, I. (2002). ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion-part I: ankle, hip, and spine, Journal of Biomechanics, 35, 543-548.   DOI
14 Chan, N. N. (1965). On circular functional relationships. Journal of the Royal Statistical Society. Series B (Methodological), 27, 45-56.
15 Diggle, P. J., Heagerty, P., Liang, K. Y. & Zeger, S. L. (2002). Analysis of longitudinal data (2nd ed.). New York, NY: Oxford University Press.
16 Draper, N. R. & Smith, H. (1998). Applied regression analysis (3rd ed.). New York, NY: John Wiley & Sons, Inc.
17 Ehrig, R. M., Taylor, W. R., Duda, G. N. & Heller, M. O. (2006). A survey of formal methods for determining the center of rotation of ball joints. Journal of Biomechanics, 39, 2798-2809.   DOI
18 De Rosario, H., Page, A., Besa, A. & Valera, A. (2013). Propagation of soft tissue artifacts to the center of rotation: A model for the correction of functional calibration techniques. Journal of Biomechanics, 46, 2619-2625.   DOI
19 Gamage, S. S. H. U. & Lasenby, J. (2002). New least squares solutions for estimating the average center of rotation and the axis of rotation. Journal of Biomechanics, 35, 87-93.   DOI
20 Faraway, J. J. (2005). Linear models with R. Boca Raton, FL: Chapman & Hall/CRC.
21 Gander, W., Golub, G. H. & Strebel, R. (1994). Least-squares fitting of circles and ellipses. BIT, 34, 558-578.   DOI
22 Ginsberg, J. H. (1998). Advanced engineering dynamics (2nd ed.). New York, NY: Cambridge University Press.
23 Goldstein, H. (1980). Classical mechanics (2nd ed.). Addison-Wesley.
24 Kasa, I. (1976). A circle fitting procedure and its error analysis. IEEE Transactions on Instrumentation and Measurement, 25, 8-14.
25 Kim, J. (2013b). The comparison of sphere fitting methods for estimating the center of rotation on a human joint. Korean Journal of Sport Biomechanics, 23, 053-062   DOI
26 Kim, J. (2010). The validity test of upper . forearm coordinate system and the exploratory analysis of the interactive effect between flexion/extension and pronation/supination during elbow joint motion. Korean Journal of Sport Biomechanics, 20, 117-127.   DOI
27 Kim, J. (2011). Comparison among functional methods of axis of rotation suitable for describing human joint motion. Korean Journal of Sport Biomechanics, 21, 449-458   DOI
28 Kim, J. (2013a). Error analysis on fitting and transformation methods for estimating the center of rotation in a spherical joint. The Korean Journal of Physical Education, 52, 523-536.
29 Long, J. S. & Ervin, L. H. (2000). Statistical computing and graphics: Using heteroscedasticity consistent standard errors in the linear regression model. The American Statistician, 54, 217-224.