• Title/Summary/Keyword: Room Mode

Search Result 297, Processing Time 0.026 seconds

High Temperature Characterization of Accumulation-mode Pi-gate pMOSFETs (고온에서 accumulation-mode Pi-gate p-MOSFET 특성)

  • Kim, Jin-Young;Yu, Chong-Gun;Park, Jong-Tae
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.7
    • /
    • pp.1-7
    • /
    • 2010
  • The device performances of accumulation-mode Pi-gate pMOSFETs with different fin widths have been characterized at high operating temperatures. The device fin height is 10nm and fin widths are 30nm, 40nm, and 50nm. The variation of the drain current, threshold voltage, subthreshold swing, effective mobility, and leakage current have been investigated as a function of operating temperatures. The drain current at high temperature is slightly larger than at room temperature. The variation of the threshold voltage as a function of the operating temperature is smaller than that of the inversion-mode MOSFETs. The effective mobility is decreased with the increase of operating temperature. It is observed that the effective mobility is enhanced as the fin width decreases.

Effect of thermal-induced microcracks on the failure mechanism of rock specimens

  • Khodayar, Amin;Nejati, Hamid Reza
    • Computers and Concrete
    • /
    • v.22 no.1
    • /
    • pp.93-100
    • /
    • 2018
  • It is seldom possible that geotechnical materials like rocks and concretes found without joints, cracks, or discontinuities. Thereby, the impact of micro-cracks on the mechanical properties of them is to be considered. In the present study, the effect of micro-crack on the failure mechanism of rock specimens under uniaxial compression was investigated experimentally. For this purpose, thermal stress was used to induce micro-cracks in the specimens. Several cylindrical and disk shape specimens were drilled from granite collected from Zanjan granite mine, Iran. Some of the prepared specimens were kept in room temperature and the others were heated by a laboratory furnace to different temperature levels (200, 400, 600, 800 and 1000 degree Celsius). During the experimental tests, Acoustic Emission (AE) sensors were used to monitor specimen failure at the different loading sequences. Also, Scanning Electron Microscope (SEM) was used to distinguish the induced micro-crack by heating in the specimens. The fractographic analysis revealed that the thin sections heated to $800^{\circ}C$ and $1000^{\circ}C$ contain some induced micro-fractures, but in the thin sections heated to $200^{\circ}C$, $400^{\circ}C$ and $600^{\circ}C$ have not been observed any micro-fracture. In the next, a comprehensive experimental investigation was made to evaluate mechanical properties of heated and unheated specimens. Results of experimental tests showed that induced micro-cracks significantly influence on the failure mode of specimens. The specimens kept at room temperature failed in the splitting mode, while the failure mode of specimens heated to $800^{\circ}C$ are shearing and the specimens heated to $1000^{\circ}C$ failed in the spalling mode. On the basis of AE monitoring, it is found that with increasing of the micro-crack density, the ratio of the number of shear cracks to the number of tensile cracks increases, under loading sequences.

A Study on the Shot Peening on the High Temperature Fatigue Crack Propagation (쇼트피이닝 가공된 스프링강의 고온 피로균열진전 평가)

  • 박경동;정찬기;하경준
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.264-268
    • /
    • 2001
  • In this study, CT specimens were prepared from spring steel(SUP9) processed shot peening which was room temperature, low temperature and high temperature experiment. And we got the following characteristics from fatigue crack growth test carried out in the environment of room, and high temperature at $25^{\circ}C,\; 50^{\circ}C, \;100^{\circ}C,\; 150^{\circ}C,\; and\; 180^{\circ}C$ in the range of stress ratio of 0.05 by means of opening mode displacement. The threshold stress intensity factor range $\DeltaK_{th}$ in the early stage of fatigue crack growth (Region I ) and stress intensity factor range $\Delta$K in the stable of fatigue crack growth (Region II) was decreased in proportion to descend temperature. It assumed that the fatigue resistance characteristics and fracture strength at low temperature and high temperature is considerable higher than that of room temperature in the early stage and stable of fatigue crack growth region.

  • PDF

A Study on the Fatigue Crack Propagation Characteristics for SUP9 Steel at Low Temperature (SUP9강의 저온피로크랙 전파특성에 관한 연구)

  • 박경동;박상오
    • Journal of Ocean Engineering and Technology
    • /
    • v.16 no.5
    • /
    • pp.80-87
    • /
    • 2002
  • In this study, CT specimens were prepared from spring steel(SUP9) which was used in suspension of automobile for room temperature and low temperature service. We got the following characteristics from fatigue crack growth test carried out in the environment of room temperature and low temperature at $25^{\circ}C$, ­3$0^{\circ}C$, ­5$0^{\circ}C$, ­7$0^{\circ}C$ and ­10$0^{\circ}C$ in the range of stress ratio of 0.05 by means of opening mode displacement. The threshold stress intensity factor range ΔKth in the early stage of fatigue crack growth (Region I) and stress intensity factor range ΔK in the stable of fatigue crack growth (Region II) was decreased in proportion to descend temperature. It is assumed that the fatigue resistance characteristics and fracture strength at low temperature and high temperature is considerable higher than that of room temperature in the early stage and stable of fatigue crack growth region.

An Effect of Temperature on the Fatigue Crack Propagation Behavior of Spring Steel for Vehicle (차량용 스프링강의 피로거동에 미치는 온도의 영향)

  • 박경동;류찬욱
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.1
    • /
    • pp.83-90
    • /
    • 2004
  • In this study, CT specimens were prepared from spring steel(SUP9) processed shot peening which was room temperature and low temperature experiment. And we got the following characteristics from fatigue crack growth test carried out in the environment of room temperature and low temperature at $25^{\circ}C$, $-30^{\circ}C$, $-50^{\circ}C$, $-70^{\circ}C$,$-100^{\circ}C$, and $-150^{\circ}C$, in the range of stress ratio of 0.05 by means of opening mode displacement. The threshold stress intensity factor range ΔKth in the early stage of fatigue crack growth (Region I)was increased but stress intensity factor range ΔK in the stable of fatigue crack growth (Region II) was decreased in proportion to decrease temperature. It is assumed that the fatigue resistance characteristics and fracture strength at low temperature and high temperature is considerably higher than that of room temperature in the early stage and stable of fatigue crack growth region.

Free Vibration Characteristics of the Rectangular Plates under Uniform Thermal Loading Part I. Analytic and FEM analysis (균일 열부가 하중을 받는 사각판의 자유 진동특성 연구 Part I. 이론 및 유한요소 해석)

  • Jeon, Byoung-Hee;Kang, Hui-Won;Lee, Young-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.2
    • /
    • pp.97-105
    • /
    • 2011
  • This paper was conducted on analytical solution using superposition and FEM analysis in the free vibration analysis of rectangular plates under uniform thermal loadings. Materials of three rectangular plates were aluminum, steel and stainless-steel respectively. Applied temperature conditions were from room temperature to $300^{\circ}C$ and boundary condition was free-free condition. Fully symmetric mode(FSM), fully antisymmetric mode(FASM) and symmetric-antisymmetric mode(SAM) were analyzed.

Study on Implementation Scheme for Integrated PSD Control System of Seoul Metro (서울메트로 PSD 통합관제시스템 구축방안에 대한 연구)

  • Kim, Yong-Hyeop;Hyun, Yong-Sub;Ryoo, Ho-Joong;Kim, Jin-Su
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1551-1559
    • /
    • 2007
  • Seoul Metro has been constructing the screen doors on the platforms to provide safe and comfort environments. The screen doors of each station are configured so that they can be operated in automatic mode in connection with ATC/ATO through the integrated control panel in the station control room and in manual mode through the control panel of the station control room and crew control panel. These systems have been implemented with different data communication protocols between systems, HMI configuration, and so on due to ordering processes, implementation time and diverse suppliers, and manufactured to be operated within single station. Seoul Metro has been planning to implement the integrated control system to secure seamless train operation and safety and to have a fast response system against emergency situations such as PSD failure and fire, by implementing the system that is able to collectively manage, monitor and control the operation status and equipment conditions of PSD on to the integrated control center. This paper has studied a scheme to reduce the budget for the future facility constructions by standardizing the data format for data communication with the integrated station control panel and using the open standard protocols, in order to secure consistency of operation, system expansion and maintenance with unified and standardized control items.

  • PDF

Analysis of Heating Energy in a Korean-Style Apartment Building 3 : The Effect of Room Condition Settings (한국형 아파트의 난방에너지 분석 3 :실내설정조건의 영향)

  • Park, Yoo-Won;Yoo, Ho-Seon;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.8
    • /
    • pp.722-728
    • /
    • 2005
  • The present paper deals with heating energy estimation in Korean-style apartments, paying special attention to the effect of room condition settings. Two types of heating modes are considered: continuous single-zone and scheduled multi-zone. In the latter, zones during unoccupied periods remain unconditioned. Also analyzed are sensitivities in heating energy with respect to the air change rate and the set temperature. The energy use is estimated with TRNSYS 15, a dynamic load calculation program. Heating energy for the actual residential condition (1.0 ACH and $24^{\circ}C$) appears to be nearly the same as that for a typical design standard (1.5 ACH and $20^{\circ}C$). The air change rate affects heating energy as sensitive]y as the set temperature. For all the simulated cases, the scheduled multi-zone heating mode is more energy-efficient than the continuous single-zone. Heating energy depends appreciably on the shading factor. It is expected that considerable heating energy for apartment houses can be saved by employing a multi-zone mode along with appropriate control devices.

Characteristics of Refractive Index Profiles at Different Temperatures in $LiNbO_3$ and $KTiOPO_4$ Waveguide Formed by 350 keV Light Ions

  • Wang, Ke-Ming;Feng Chen;Hui Hu;Xia, Hui-Hao;Wang, Xue-Lin;Shi, Bo-Rong;Lu, Qing-Ming
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.S1
    • /
    • pp.28-32
    • /
    • 2003
  • Both $LiNbO_3$ and $KTiOPO_4$ samples were implanted with 350 keY $H^+$ and $He^+$ ions at different doses ranging from $1 ${\times}$\times10^{16}$ to of $5 ${\times}$\times10^{16}$ ions/$\textrm{cm}^2$. Single and multi-energy implantations were performed at room temperature. Mono-mode or a few modes in both $LiNbO_3$ and $KTiOPO_4$ waveguides were observed. The effect of temperature on the refractive index profiles of $LiNbO_3$ and $KTiOPO_4$ waveguids was studied. The temperature covered from room temperature, $200^{\circ}C$, 194.5 K (dry ice) and 77K (liquid nitrogen). Different mechanisms are needed to interpret the observed behavior. A n, increased mono-mode $LiNbO_3$ waveguide was formed by multi-energy keV $He^+$ ions.

Investigation of receiving position in the measurement method for floor impact sound in a testing building (표준시험동 바닥충격음 측정위치에 대한 고찰)

  • Lee, Sin-Young;Yoo, Seung-Yup;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.964-968
    • /
    • 2007
  • The measurement of floor impact sound have been standardized in KS 2810-1 and 2. The height of receiving microphones position is specified in the standard as 1.2m which is almost half height of apartment rooms as a listening position. In this study, receiving positions are investigated by measuring the distribution of sound pressure levels at 792 receiving microphone positions in the standard testing building. Standard impact sources, tapping machine and impact ball, are driven on the center position in the source room where is located at the above floor. It was found that the distribution of sound pressure levels in the receiving room indicates significant deviation at different frequencies there is more than 5dB drop at 63Hz but 2dB rise at 125Hz at a height of 1.2m when the impact ball is driven, in the other case of a generating tapping machine there is more than 2dB rise at 125Hz at a height of 1.2m due to room modes.

  • PDF