• Title/Summary/Keyword: Roll-to-Roll system

Search Result 904, Processing Time 0.031 seconds

Verify Image-Guided Shifts for 6DoF Couch using Yonsei Cancer Center QA Set (Yonsei Cancer Center QA Set을 이용한 6DoF Couch의 이동 정확성 검증)

  • Jung, Dongmin;Park, Hyokuk;Yoon, Jongwon;Lee, Sangkyu;Kim, Jooho;Cho, Jeonghee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.7-18
    • /
    • 2017
  • Purpose: A QA Set was established to verify the movement accuracy of image-guided 6DoF Couch and to evaluate its usefulness. Materials and Methods: Two sets of linear accelerators equipped with 6DoF Couch and CBCT were used. Using the established QA Set, each CBCT image was obtained over 15 times through the Penta-Guide Phantom installed with off-set shift values along six translational (Translation; TX, TY, TZ) and rotational (Rotation, Pitch; RX, Roll; RY, Yaw; RZ) directions. Using this method, we compared the reference image and the registration image, and we analyzed the error calculated by measuring the positional accuracy of the modified 6DoF Couch. Results: The Air Cavity corresponding to the Pixel of the reference image and the registration image were all contained between 30 and 66, and the revealing high registration accuracy. Error between the modified off-set value of 6DoF Couch and the measured value along translational directions were $0.25{\pm}0.18mm$ in the TX direction, $0.25{\pm}0.25mm$ in the TY direction, and $0.36{\pm}0.2mm$ in the TZ direction. Misalignments along the rotational axis were $0.18{\pm}0.08^{\circ}$ in the RX direction, $0.26{\pm}0.09^{\circ}$ in the RY direction, and $0.11{\pm}0.08^{\circ}$ in the RZ direction, it was corrected precisely for any value. Conclusion: Using the YCC QA Set, we were able to verify the error of 6DoF Couch along both the translational and rotational directions in a very simple method. This system would be useful in performing Daily IGRT QA of 6DoF Couch.

  • PDF

Evaluation of the Usefulness of Exactrac in Image-guided Radiation Therapy for Head and Neck Cancer (두경부암의 영상유도방사선치료에서 ExacTrac의 유용성 평가)

  • Baek, Min Gyu;Kim, Min Woo;Ha, Se Min;Chae, Jong Pyo;Jo, Guang Sub;Lee, Sang Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.7-15
    • /
    • 2020
  • Purpose: In modern radiotherapy technology, several methods of image guided radiation therapy (IGRT) are used to deliver accurate doses to tumor target locations and normal organs, including CBCT (Cone Beam Computed Tomography) and other devices, ExacTrac System, other than CBCT equipped with linear accelerators. In previous studies comparing the two systems, positional errors were analysed rearwards using Offline-view or evaluated only with a Yaw rotation with the X, Y, and Z axes. In this study, when using CBCT and ExacTrac to perform 6 Degree of the Freedom(DoF) Online IGRT in a treatment center with two equipment, the difference between the set-up calibration values seen in each system, the time taken for patient set-up, and the radiation usefulness of the imaging device is evaluated. Materials and Methods: In order to evaluate the difference between mobile calibrations and exposure radiation dose, the glass dosimetry and Rando Phantom were used for 11 cancer patients with head circumference from March to October 2017 in order to assess the difference between mobile calibrations and the time taken from Set-up to shortly before IGRT. CBCT and ExacTrac System were used for IGRT of all patients. An average of 10 CBCT and ExacTrac images were obtained per patient during the total treatment period, and the difference in 6D Online Automation values between the two systems was calculated within the ROI setting. In this case, the area of interest designation in the image obtained from CBCT was fixed to the same anatomical structure as the image obtained through ExacTrac. The difference in positional values for the six axes (SI, AP, LR; Rotation group: Pitch, Roll, Rtn) between the two systems, the total time taken from patient set-up to just before IGRT, and exposure dose were measured and compared respectively with the RandoPhantom. Results: the set-up error in the phantom and patient was less than 1mm in the translation group and less than 1.5° in the rotation group, and the RMS values of all axes except the Rtn value were less than 1mm and 1°. The time taken to correct the set-up error in each system was an average of 256±47.6sec for IGRT using CBCT and 84±3.5sec for ExacTrac, respectively. Radiation exposure dose by IGRT per treatment was measured at 37 times higher than ExacTrac in CBCT and ExacTrac at 2.468mGy and 0.066mGy at Oral Mucosa among the 7 measurement locations in the head and neck area. Conclusion: Through 6D online automatic positioning between the CBCT and ExacTrac systems, the set-up error was found to be less than 1mm, 1.02°, including the patient's movement (random error), as well as the systematic error of the two systems. This error range is considered to be reasonable when considering that the PTV Margin is 3mm during the head and neck IMRT treatment in the present study. However, considering the changes in target and risk organs due to changes in patient weight during the treatment period, it is considered to be appropriately used in combination with CBCT.

Tourism Resource Development for the Activation of Regional Economic and the Roll of Tourism Policy (지역경제 활성화를 위한 관광자원개발과 관광정책의 역할)

  • Kim, Tae-Heon;Park, Suk-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.5
    • /
    • pp.403-412
    • /
    • 2011
  • This study aims at proposing clear direction of tourism policy through analyzing the correlation between tourism resource, tourism system and activation of regional economic. A total of 283 samples were ultimately collected in survey of 300 researchers from the national and public institutes in provinces Chungchong-do and Kyungsang-do in July 2010 alone. SPSS 15.0 and AMOS 6.0 were used to test the model. Analysis showed that the more regional tourism resources have more significant effect on tourism system and tourist-attracting strategy, and that tourism system exerts influence on tourist-attracting strategy. So it was proved that the tourism policy effects meaningfully on vitalization of regional economic, and it was confirmed that the tourism system is more effective on the energization of regional economic than the tourist-attracting strategy. But the hypothesis has been rejected unexpectedly that tourist attractions have consequences for the activation of regional economic. It establishes the fact that it is useless for regional economy regardless of abundant regional tourism resources, if the tourism policy is not concretely in force. Therefore, Korean government must intercept overissue and overlapping investments on tourism development by the local government and induce qualitative growth of tourism sector through upgrading of development guidelines and the criteria for selecting tourism special zone, regional festival and cultural assets, and its continuous assessment and management. And it is desirable to enforce the connected cooperation projects between local governments and the 5+2 great-sphere economic blocs on government-level.

Singing Voice Synthesis Using HMM Based TTS and MusicXML (HMM 기반 TTS와 MusicXML을 이용한 노래음 합성)

  • Khan, Najeeb Ullah;Lee, Jung-Chul
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.5
    • /
    • pp.53-63
    • /
    • 2015
  • Singing voice synthesis is the generation of a song using a computer given its lyrics and musical notes. Hidden Markov models (HMM) have been proved to be the models of choice for text to speech synthesis. HMMs have also been used for singing voice synthesis research, however, a huge database is needed for the training of HMMs for singing voice synthesis. And commercially available singing voice synthesis systems which use the piano roll music notation, needs to adopt the easy to read standard music notation which make it suitable for singing learning applications. To overcome this problem, we use a speech database for training context dependent HMMs, to be used for singing voice synthesis. Pitch and duration control methods have been devised to modify the parameters of the HMMs trained on speech, to be used as the synthesis units for the singing voice. This work describes a singing voice synthesis system which uses a MusicXML based music score editor as the front-end interface for entry of the notes and lyrics to be synthesized and a hidden Markov model based text to speech synthesis system as the back-end synthesizer. A perceptual test shows the feasibility of our proposed system.

Design for Deep Learning Configuration Management System using Block Chain (딥러닝 형상관리를 위한 블록체인 시스템 설계)

  • Bae, Su-Hwan;Shin, Yong-Tae
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.3
    • /
    • pp.201-207
    • /
    • 2021
  • Deep learning, a type of machine learning, performs learning while changing the weights as it progresses through each learning process. Tensor Flow and Keras provide the results of the end of the learning in graph form. Thus, If an error occurs, the result must be discarded. Consequently, existing technologies provide a function to roll back learning results, but the rollback function is limited to results up to five times. Moreover, they applied the concept of MLOps to track the deep learning process, but no rollback capability is provided. In this paper, we construct a system that manages the intermediate value of the learning process by blockchain to record the intermediate learning process and can rollback in the event of an error. To perform the functions of blockchain, the deep learning process and the rollback of learning results are designed to work by writing Smart Contracts. Performance evaluation shows that, when evaluating the rollback function of the existing deep learning method, the proposed method has a 100% recovery rate, compared to the existing technique, which reduces the recovery rate after 6 times, down to 10% when 50 times. In addition, when using Smart Contract in Ethereum blockchain, it is confirmed that 1.57 million won is continuously consumed per block creation.

Postural Control in Brain Damage Patients According to Moving Surround (뇌기능 장애 환자의 가상영상(Moving Sorround) 자극에 따른 자세 균형 제어)

  • 김연희;최종덕;이성범;김종윤;이석준;박찬희;김남균
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2002.11a
    • /
    • pp.233-244
    • /
    • 2002
  • The purpose of this study is to assess the ability of balance control in moving surround using head mount device and force platform and to examine the clinical usefulness of COP parameters. Fifteen patients with stroke and healthy persons were participated. COP parameters were obtained as total path distance, frequency of anterior-posterior and medial-lateral component by FFT analysis, weight-spectrum analysis in the two different conditions; (1) in comfortable standing with opened or closed eyes, (2) in virtual moving surround delivered using HMD to four different moving pattern. In virtual moving surround setting, moving pattern was composed of close-far, superior-inferior tilting(pitch), right-left tilting(roll) and horizontal rotation(yaw) movement. In all parameters, the reliebility of COP analysis system was significantly high. Also, the construct validity compared between fifteen patients with stroke and normal persons was excellent in virtual moving surround condition(p

  • PDF

The characteristics of nuclear powered submarine and the use of enriched uranium (원자력 추진 잠수함의 특성과 농축우라늄 사용)

  • Jang, Jun-Seop
    • Strategy21
    • /
    • s.41
    • /
    • pp.261-293
    • /
    • 2017
  • Nuclear power is a way of attaining an enormous amount of energy with relatively small amount of resources and after it has been introduced to the submarine since 1954, there are approximately 150 of nuclear powered submarine currently on a mission around the world. This is due to the maneuverability, mountability and covertness of nuclear submarines. However, there are other tasks, not only the high level of nuclear technology that are needed to be dealt with in order to construct nuclear powered submarine. The biggest task of all is to secure the enriched uranium. Accordingly, this research is about the way of enriching and securing the nuclear fuel that are used in the nuclear submarine with the characteristics, merits and demerits of the nuclear submarine. Due to the fact that the pressurized water reactor in South Korea is the reactor that was originally built for the development of nuclear powered submarine, many parts is designed to be suitable for the submarine propulsion. However, in order to apply this to submarine it is needed to consider additional requests such as the position of reactor, accident-coping system, radioactive covering, reactor output adjustment and ship's pitch and roll in order to apply this to submarine. Nuclear submarines have much higher speed based on the powerful propulsion in comparison with diesel-electric submarine and also have bigger loading area. Besides, there is no need to snorkel and they also have advantages in covertness with the multi-noise proof system. The nuclear technology in South Korea has seen the dramatic development since 1962 and in 1998 reached to the level that we have succeeded in the localization of nuclear plant and exported the world-class one-piece small-sized reactor (SMART) to UAE. To operate these reactors, we import the whole quantity of low-enriched uranium and having our own uranium enrich facility is not probable because of the budget and international regulations. With the ROK/US nuclear agreement revised on 2015 November, the enrichment of uranium that are available without special permission has changed up to 20%. According to the assumption that we use the 20% enrichment of Uranium on U.S. virginia class submarine, it is necessary to change the fuel after 11 years and it will cause additional cost of 1 billion dollars. But the replace period by the uranium's enrichment rate is not fixed so that it is possible to change according to the design of reactor. Therefore, I would like to make a suggestion on two types of design concepts of nuclear submarine that can be operated for 30 years without nuclear fuel change by using the 20% enriched uranium from ONNp.First of all, it is possible by increasing the size of reactor by 3 times and it results in the 1,000t increase of the weight. And secondly, it is by designing the one piece reactor to insert devices such as steam turbine, condenser into the inside of nuclear core like the Rubis class submarines of France.

Research on the Development of the Oriental Medical Model on the Health Examination in the Industry (산업장 건강검진의 한의학적 모델 개발 연구)

  • Chong M.S.;Kim S.C.;Lee E.K.;Chun E.J.;Han J.M.;Lee S.K.;Kang S.H.;Yu T.S.;Jeung J.Y.;Song Y.S.;Lee K.N.
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.4 no.1
    • /
    • pp.32-50
    • /
    • 2000
  • On the process of research in the plan on oriental medical participation in the industrial health sponsored by BK21 project, we carried out the oriental medical health examination program for workers during former half-year We reached the conclusion as follows, 1. The oriental medical health examination program is contents and formalities that should be determined by present industrial health system, based on the oriental medical system and scholastic character, and included probability of the western and oriental medical cooperation. 2. The oriental medical health examination program can promote capability of individual health management and productive power of workers, and it is capable to manage on the self-conscious symptoms and macroschophically approach to their environment 3. The oriental medical health examination program that we have developed, is flow as questionare, understanding of working environment, information of result and later management. It is composed of three fields as follow , first, use of pulse diagnostic apparatus, understanding of the health promotion life style, and diagnosis of the oriental medical doctor, second, analysis of constitution, third, photographing for understanding of the musculoskeletal disorders, questionare for musculoskeletal self-conscious symptoms, and diagnosis of oriental medical doctor. 4. The oriental medical health examination program that we have developed, progressive from the view point of health, makes the oriental medical doctor's roll more important. It is the first trial at the western and oriental medical cooperation and characterized by excellence about musouloskeletal disorders. But it need to be improved in aspects of time and specialist on the health examination, diagnostic apparatus, control of examinant and later management. So we think that it needs research on the employment of health examination specialist, establishment of later management system, development of significantly diagnosable standard and assessable form on the health examination, and contents of health examination on the western and oriental medical cooperation.

  • PDF

Daily Setup Uncertainties and Organ Motion Based on the Tomoimages in Prostatic Radiotherapy (전립선암 치료 시 Tomoimage에 기초한 Setup 오차에 관한 고찰)

  • Cho, Jeong-Hee;Lee, Sang-Kyu;Kim, Sei-Joon;Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.99-106
    • /
    • 2007
  • Purpose: The patient's position and anatomy during the treatment course little bit varies to some extend due to setup uncertainties and organ motions. These factors could affected to not only the dose coverage of the gross tumor but over dosage of normal tissue. Setup uncertainties and organ motions can be minimized by precise patient positioning and rigid immobilization device but some anatomical site such as prostate, the internal organ motion due to physiological processes are challenge. In planning procedure, the clinical target volume is a little bit enlarged to create a planning target volume that accounts for setup uncertainties and organ motion as well. These uncertainties lead to differences between the calculated dose by treatment planning system and the actually delivered dose. The purpose of this study was to evaluate the differences of interfractional displacement of organ and GTV based on the tomoimages. Materials and Methods: Over the course of 3 months, 3 patients, those who has applied rectal balloon, treated for prostatic cancer patient's tomoimage were studied. During the treatment sessions 26 tomoimages per patient, Total 76 tomoimages were collected. Tomoimage had been taken everyday after initial setup with lead marker attached on the patient's skin center to comparing with C-T simulation images. Tomoimage was taken after rectal balloon inflated with 60 cc of air for prostate gland immobilization for daily treatment just before treatment and it was used routinely in each case. The intrarectal balloon was inserted to a depth of 6 cm from the anal verge. MVCT image was taken with 5 mm slice thickness after the intrarectal balloon in place and inflated. For this study, lead balls are used to guide the registration between the MVCT and CT simulation images. There are three image fusion methods in the tomotherapy, bone technique, bone/tissue technique, and full image technique. We used all this 3 methods to analysis the setup errors. Initially, image fusions were based on the visual alignment of lead ball, CT anatomy and CT simulation contours and then the radiation therapist registered the MVCT images with the CT simulation images based on the bone based, rectal balloon based and GTV based respectively and registered image was compared with each others. The average and standard deviation of each X, Y, Z and rotation from the initial planning center was calculated for each patient. The image fusions were based on the visual alignment of lead ball, CT anatomy and CT simulation contours. Results: There was a significant difference in the mean variations of the rectal balloon among the methods. Statistical results based on the bone fusion shows that maximum x-direction shift was 8 mm and 4.2 mm to the y-direction. It was statistically significant (P=<0.0001) in balloon based fusion, maximum X and Y shift was 6 mm, 16mm respectively. One patient's result was more than 16 mm shift and that was derived from the rectal expansions due to the bowl gas and stool. GTV based fusion results ranging from 2.7 to 6.6 mm to the x-direction and 4.3$\sim$7.8 mm to the y-direction respectively. We have checked rotational error in this study but there are no significant differences among fusion methods and the result was 0.37$\pm$0.36 in bone based fusion and 0.34$\pm$0.38 in GTV based fusion.

  • PDF

A Design for Realtime Monitoring System and Data Analysis Verification TA to Improve the Manufacturing Process Using HW-SW Integrated Framework (HW-SW 통합 프레임워크를 활용한 제조공정 개선을 위한 실시간 모니터링 시스템과 데이터 분석검증 TA설계)

  • Kim, Jae Chun;Jin, Seon A;Park, Young Hee;Noh, Seong Yeo;Lee, Hyun Dong
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.9
    • /
    • pp.357-370
    • /
    • 2015
  • Massive data occurred in a manufacturing place is able to fulfill very important roll to improve the manufacturing process. Domestic manufacturing business has been making an multilateral effort to react the change of manufacturing circumstance, but it undergoes many difficulties due to technical weakness. Coatings is a type of paint. It protect products by forming a film layer on the products and assigns various properties to those. The research of coatings is one of the fields studied actively in the polymer industry. The importance of the coatings in various industries is more increased. However, the industry still performs a mixing process in dependence on operator's experiences. In this paper, we propose a design for realtime monitoring system and data analysis verification TA to improve the manufacturing process using HW-SW integrated framework. Analysis results from the proposed framework are able to improve the coatings formulation process by collecting more quantitative reference data for work and providing it to work place. In particular, the framework may reduce the deterioration and loss cost which are caused by absence of a standard data as a accurate formulation criteria. It also may suggest a counterplan regarding errors which can be occurred in the future by deriving a standard calibration equation from the analysis using R and Design of Experiments about an error data generated in the mixing step.