• Title/Summary/Keyword: Robot Foot

Search Result 144, Processing Time 0.036 seconds

Detection of Implicit Walking Intention for Walking-assistant Robot Based on Analysis of Bio/Kinesthetic Sensor Signals (보행보조로봇을 위한 다중 생체/역학 센서의 신호 분석 및 사용자 의도 감지)

  • Jang, Eun-Hye;Chun, Byung-Tae;Chi, Su-Young;Lee, Jae-Yeon;Cho, Young-Jo
    • The Journal of Korea Robotics Society
    • /
    • v.5 no.4
    • /
    • pp.294-301
    • /
    • 2010
  • In order to produce a convenient robot for the aged and the lower limb disabled, it is needed for the research detecting implicit walking intention and controlling robot by a user's intention. In this study, we developed sensor module system to control the walking- assist robot using FSR sensor and tilt sensor, and analyzed the signals being acquired from two sensors. The sensor module system consisted of the assist device control unit, communication unit by wire/wireless, information collection unit, information operation unit, and information processing PC which handles integrated processing of assist device control. The FSR sensors attached user's the palm and the soles of foot are sensing force/pressure signals from these areas and are used for detecting the walking intention and states. The tilt sensor acquires roll and pitch signal from area of vertebrae lumbales and reflects the pose of the upper limb. We could recognize the more detailed user's walking intention such as 'start walking', 'start of right or left foot forward', and 'stop walking' by the combination of FSR and tilt signals can recognize.

Fast and Safe Contact Establishment Strategy for Biped Walking Robot (이족 보행 로봇을 위한 빠르고 안전한 접촉 생성 전략)

  • Lee, Hosang;Jung, Jaesug;Ahn, Junewhee;Park, Jaeheung
    • The Journal of Korea Robotics Society
    • /
    • v.16 no.2
    • /
    • pp.147-154
    • /
    • 2021
  • One of the most challenging issues when robots interact with the environment is to establish contact quickly and avoid high impact force at the same time. The proposed method implements the passive suspension system using the redundancy of the torque-controlled robot. Instead of utilizing the actual mechanical compliance, the distal joints near the end-effector are controlled to act as a virtual spring-damper system with low feedback gains. The proximal joints are precisely controlled to push the mid-link, which is defined as the boundary link between the proximal and distal joints, towards the environment with high feedback gains. Compared to the active compliance methods, the contact force measurements or estimates are not required for contact establishment and the control time delay problems do not occur correspondingly. The proposed method was applied to the landing foot control of the 12-DoF biped robot DYROS-RED in the simulations. In the results, the impact force during landing was significantly reduced at the same collision speed.

Fault Tolerant Gaits of a Hexapod Robot with a Foot Trajectory Adjustment (다리 궤적을 조정하는 육각 보행 로봇의 내고장성 걸음새)

  • Yang Jung-Min
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.3 s.303
    • /
    • pp.1-10
    • /
    • 2005
  • This paper proposes a novel fault-tolerant gait planning of a hexapod robot considering kinematic constraints. The failure concerned in this paper is a locked joint failure for which a joint in a leg cannot move and is locked in place. It is shown that the conventional fault-tolerant gait of a hexapod robot for forward walking on even terrain may be fallen into deadlock, depending on the configuration of the failed leg. For coping with such deadlock situation, a novel fault-tolerant gait planning is proposed. It can avoid deadlock by adjusting the position of the foot trajectory, and has the same leg sequence and stride length as those of the conventional fault-tolerant gait. To demonstrate the superiority of the proposed scheme, a case study is presented in which a hexapod robot, having walked over even terrain before a locked joint failure, could avoid deadlock and continue its walking by the proposed fault-tolerant gait planning.

Frictional Behavior of Solid and Hollow Cylinders in Contact Against a Porcine Intestine Specimen

  • Kim, Young-Tae;Kim, Dae-Eun;Park, Suk-Ho;Yoon, Eui-Sung
    • KSTLE International Journal
    • /
    • v.7 no.2
    • /
    • pp.51-55
    • /
    • 2006
  • In order to design an effective foot surface which can provide adequate friction for a self-propelled medical microrobot moving inside the small intestine, frictional mechanisms between the small intestine inner wall and the foot surface of the robot must be understood. In this paper, mechanical interlocking effect was considered to design the surface of the foot that can generate the desired frictional force. The concept of the design was derived from the hookworm that lives inside the small intestine. Hookwarms are known to adhere to the small intestine wall by interlocking with villi on the surface of the small intestine. The interlocking mechanism was considered as the main frictional mechanism for the design of the microrobot foot surface in this work. 2 mm and 6 mm diameter solid and hollow cylindrical shaped foot specimens were designed and tested to assess the frictional force between the specimens and the porcine small intestine specimen.

Optimization and sensitivity analysis of the humanoid robot's foot using the design of experiments (실험계획법에 의한 휴머노이드 발의 민감도 해석 및 최적화)

  • Yoon, Ji-Won;Park, Tae-Won;Jung, Sung-Pil;Park, Joong-Kyung
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.933-938
    • /
    • 2007
  • These days, up-to-date humanoid robots are continuously developed. Among them, Qrio, Asimo[1,2] are famous for its unique walking technology and natural movement. These robots could show manufacturers' technological improvement and leave a good impression to the customer. In accordance with global trends, Samsung is also producing humanoid robot. The humanoid robot, however, could walk like a human compared to the industrial robot fixed in the factory. This feature could cause another dynamic effect while walking. In this paper, the robot's feet were examined to find out parameters that affect stability of the humanoid robot's feet. With the sensitivity analysis, the optimization procedure in design of experiments finds the most suitable performance of robot. Maximum deflection of the frame upon various cases was minimized, and rubber coefficients for shock absorption were optimized.

  • PDF

Development of 6-axis Ankle Force/Moment Sensor for an Intelligent Foot of a Humanoid Robot (인간형 로봇의 지능형 발을 위한 6축 발목 힘/모멘트센서)

  • Kim, Gab-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.1 s.190
    • /
    • pp.27-36
    • /
    • 2007
  • This paper describes the development of 6-axis ankle force/moment sensor for the intelligent feet of a humanoid robot. When the robot walks on uneven terrain, the feet should perceive the applied forces Fx, Fy, Fz and moments Mx, My, Mz from the attached 6-axis force/moment sensor on their ankles. Papers have already been published have some disadvantages in the size of the sensor, the rated output and so on. The rated output of each component sensor (6-axis ankle force/moment sensor) is very important to design the 6-axis force/moment sensor for precision measurement. Therefore, each sensor should be designed to get the similar rated output under each rated load. Also, the size of the sensor is very important for mounting to robot's feet. Therefore, the diameter should be below 100 mm and the height should be below 40mm. In this paper, first, the structure of a 6-axis ankle force/moment sensor was modeled for a humanoid robot's feet newly, Second, the equations to predict the strains on the sensing elements was derived, third, the size of the sensing elements was designed by using the equations, then, the sensor was fabricated by attaching straingages on the sensing elements, finally, the characteristic test of the developed sensor was carried out. The rated outputs from the derived equations agree well with the results from the experiments. The interference error of the sensor is less than 2.94%.

Wireless Interface of Motion between Human and Robot

  • Jung, Seul;Jeon, Poong-Woo;Cho, Hyun-Taek;Jang, Pyung-Soo;Cho, Ki-Ho;Kim, Jeong-Gu;Song, Duck-Hee;Choi, Young-Kwon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.59.4-59
    • /
    • 2001
  • In this paper, wireless interface of the motion between human and robot is implemented. The idea is that if a human who is equiped with device including accelerometer and rate-gyro sensor move his/her arm, then the robot follows human motion. The robot is designed as wheeled type mobile robot with two link arms. The robot´s basic movements such as forward, backward, left, right movement can be controlled from foot sensor which human steps on. Arm movements can be controlled by arm motion of human motion. In order to detect human motion, sensor data analysis from gyro and accelerometer has to be done. Data from sensors are transferred through wireless communication to activate the robot.

  • PDF

Contact Repulsion of Robotic Foot and Its Influence on Knee and Hip Joints (로봇 발의 접촉 반발력이 무릎 및 힙 관절에 미치는 영향)

  • Kim, Byoung-Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.1
    • /
    • pp.12-17
    • /
    • 2013
  • This paper presents a model of bipedal leg mechanism with a compliant foot, and the contact repulsion of the foot for a typical walking pattern and its influence on the knee and hip joints of the leg will be analyzed. This analysis is useful for us to figure out the physical impact of the foot when a walking robot takes a step. Also it can be applied to determine the joint specification of the leg mechanism. As a result, it is shown that the compliance characteristics of a robotic foot can contribute to alleviate the joint torques of the leg affected by the contact repulsion of the foot.

Dynamic Trajectory Control of a Biped Robot with Curved Soles

  • Yeon, Je-Sung;Park, Jong-Hyeon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.225-230
    • /
    • 2003
  • This paper proposes a desired trajectory and a control algorithm for a biped robot with curved soles. Firstly, we derived the desired trajectory from a model called the Moving Inverted Pendulum Mode (MIPM) of which a contact point of the foot is moving in the horizontal direction. A biped robot with curved soles is under-actuated system, because it has one contact point with the ground during the single supporting phase. Therefore, to solve the under-actuated problem, we changed control variables, used modified dynamic equations and used the computed torque control. The simulation results show that a biped robot with curved soles walks stably. Also, fast walking and natural motion of a biped robot can be implemented.

  • PDF

Walking Pattern Generation for a Biped Robot Using Polynomial Approximation (다항식 근사를 이용한 이족보행 로봇의 보행패턴 생성)

  • Kang, Yun-Seok;Park, Jung-Hun;Yim, Hong-Jae
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.567-572
    • /
    • 2004
  • In this research, a stable walking pattern generation method for a biped robot is presented. A biped robot is considered as constrained multibody system by several kinematic joints. The proposed method is based on the optimized polynomial approximation of the trunk motion along the moving direction. Foot motions can be designed according to the ground condition and walking speed. To minimize the deviation from the desired ZMP, the trunk motion is generated by the fifth order polynomial approximation. Walking simulation for a virtual biped robot is performed to demonstrate the effectiveness and validity of the proposed method. The method can be applied to the biped robot for stable walking pattern generation.

  • PDF