• 제목/요약/키워드: Road dust

검색결과 122건 처리시간 0.031초

지하철 환기구 개선 방안에 관한 연구 (A Study on Subway ventilation improve a program)

  • 최성호;최순기;손영진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1970-1974
    • /
    • 2010
  • This paper is how to improve contaminated air by the pollutant from vehicles through ventilators and entrance at the underground station. We are looking for the environment management to take care of customers. There is two ventilation systems. One is natural ventilation system, the other is forced ventilation system. Usually, subway ventilators were installed low on the sidewalk. There are lots of craps on the ventilators, so these things interrupt influx of outside air. But the gas from the vehicles comes into the station through entrance. There is lots of noise while ventilations run. So we install the supply air vents away from the road for the customers. If it's difficult, we cover around the ventilator with clear plastic plates more than 2M heights. We also install silencer on the ventilators. We install the air curtains on the entrances to prevent dust from outside. Seoul Metropolitan has a plan to make 60M deep underground road. To improve underground road air quality, ventilators should be installed that consider the above information.

  • PDF

고가 구조물 건설에 따른 일조권 분석 (Analysis of the right to sunshine for elevated structure construction)

  • 강기수;김상석;양승태;강인준
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2004년도 춘계학술발표회논문집
    • /
    • pp.485-490
    • /
    • 2004
  • Recently, distribution transfer velocity was extremely lowered by high supply rate of vehicle and low road rate. Therefore expansions of transfer network these were subway, road and railway to recover competitive power as a reform measure of physical distribution traffic were become preference previous subject. For reason of that, an expansion of transfer network is meeting competitive power as selected an elevated road in the ground road network that condition of location calm and get out of the existing urban than the underground road to connect oversensitive a large city and expanded small and medium satellite town. In the meantime, while elevated structures construct, they go through the civilian residential section, agriculture land, etc. The consequence is that it raises a vibration, noise, dust, an infringement of the right to a view and an infringement of the right to a sunshine. In this study, we analyzed Quantitatively sunshine quantity with building 3D simulation model of civil structure. Therefore, we present as planning data to reduce a civilian appeal for dispute of the right to sunshine and an economic and time loss between the government and construction company In addition to that, for the standard of the standard plan of usable sunshine quantity program in the practical business, the building of convenient user interface will be the project to be done.

  • PDF

건설폐기물 중간처리 사업장과 인근 지역의 미세먼지 발생 현황 및 특성에 관한 연구 (A Study on the Current Status and Characteristics of Fine Dust Generation in Construction Waste Intermediate Treatment Plants and Neighboring Areas)

  • 장경필;송태협;김병윤
    • 한국건설순환자원학회논문집
    • /
    • 제9권4호
    • /
    • pp.405-412
    • /
    • 2021
  • 본 연구는 건설폐기물 중간처리 사업장에서 발생하는 미세먼지의 환경영향을 조사하여, 향후 예상되는 정부의 강화된 환경규제에 공학적 자료 및 미세먼지 발생 억제 방안 제시를 목적으로 한다. 연구 결론은 다음과 같다. 1) 사업장 내의 미세먼지 농도측정 결과, 파분쇄 작업이 이루어지는 지점에서 최대치인 160㎍/m3가 측정되었으며, 폐기물 하적되는 지점이 두 번째로 높게 나타나, 향후 집중적인 발생 억제 방안의 적용이 필요하다. 2) 사업장 내 젖은 도로 상태는 113㎍/m3, 건조된 상태 때는 50㎍/m3의 미세먼지 농도가 측정되어, 살수만으로도 미세먼지를 50% 정도는 감소시키는 것으로 나타났다. 3) 이격에 따른 영향을 분석한 결과, 작업장 가동 중의 PM10은 사업장에서 인근 지역과 비교하여 약 25㎍/m3 높게 측정되었으며, PM2.5의 경우는 인근 지역과 뚜렷한 차이가 없는 것으로 나타났다. 4) 중금속 함유량을 측정한 결과는 인근 지역에 영향을 주지 않는 것으로 나타났다.

전기로 제강분진의 재활용과정에서 발생된 Clinker의 전기로에서의 가열용해에 의한 자원화에 관한 연구 (A Study on the Resource Development by Heat Dissolution in Electric Arc Furnace of Clinker generated in the Recycling Process of Electric Arc Furnace Dust)

  • 윤재홍;윤치현;本庄昭郎
    • 열처리공학회지
    • /
    • 제36권1호
    • /
    • pp.22-32
    • /
    • 2023
  • In general, when scrap is dissolved in an electric arc furnace, the amount of electric furnace steel dust (EAFD) generated is about 1.5% of the scrap charge amount, and the electric furnace steel dust collected by the bag filter is charged into the Rotary Kiln or Rotary Hearth Furnace (RHF), and the zinc component is recovered as crude zinc oxide, at which time a clinker of Fe-Base is generated. In this research, first, for the efficient resource conversion of electric furnace steel dust, a reduction and roasting experiment was conducted and the reaction kinetics was examined. As a result of the experiment, it was observed that the reduction and roasting reaction was actively conducted in the range of 1100~1150℃, and melting occurred in the range of 1250℃. In the past, this clinker was widely used as a roadbed material for road construction and an Fe-Source for cement production, but in recent years, it has been mainly reclaimed due to strengthening environmental standards. However, landfill treatment is by no means a desirable treatment method due to environmental pollution caused by leachate, expensive landfill costs, and waste of Fe resources. Therefore, in order to more actively recycle the Fe component in the clinker, first of all the clinker was pulverized into an optimal particle size, and anthracite and binder (starch) were added to the magnetic material obtained by specific gravity and magnetic separation for briquet. As a experimental results, it was possible to efficiently separate clinker as Fe component and other slag component by specific gravity and magnetic force. As a results of loading and dissolving the manufactured briquet clinker in an electric arc furnace, it was observed that the unit of power and production yield were clearly improved and the carbon addition effect in molten metal was also somewhat.

TiO2를 치환율에 따른 투수블록의 흡착 특성 (Adsorption Properties of Permeable Block according to the Replacement Ratio of TiO2)

  • 이혜은;유재균;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.74-75
    • /
    • 2021
  • In the recent 2017 annual average fine dust concentration (PM2.5) statistics released by the Organization for Economic Cooperation and Development (OECD), Korea has a high concentration of 25.14㎍/m3, which is about twice the average of 12.5㎍/m3 in OECD countries. Fine dust (PM2.5) is the main source of secondary pollutant production by the reaction of primary pollutants emitted from automobiles and thermal power plants, mainly composed of sulfates, nitrates, and organic carbon. The permeable block is an eco-friendly product that prevents rainwater from collecting on the surface of the road because it does not penetrate the groundwater properly, and is widely constructed on sidewalks or parking lots to recharge groundwater in case of rain. In addition, the pavement of the permeable block is a fundamental solution to reduce pollution by preventing rainwater from flowing into the stream, and it also has the advantage of easy replacement as well as low replacement costs. Therefore, this study was a basic experiment to produce permeable blocks mixed with TiO2 and diatomite to improve indoor air quality, and intended to analyze the flexural strength and compressive strength of permeable blocks mixed with TiO2.

  • PDF

전산유체역학을 이용한 도로 식재 배치 유형에 따른 미세먼지 저감 분석 (Analysis of Fine Dust Reduction according to Road Planting Arrangement Type Using Computational Fluid Dynamics)

  • 이승헌;김찬민;김락우
    • 생물환경조절학회지
    • /
    • 제32권4호
    • /
    • pp.285-294
    • /
    • 2023
  • 미세먼지 저감을 위한 가장 현실적이고 효율적인 방법은 도시 지역의 녹지 조성으로 이에 대한 관심이 증가하고 있다. 국내 도시 특성상 도로변에 녹지를 조성할 경우 별도의 녹지 조성없이 대기 중에 떠다니는 미세먼지나 차량에서 발생한 미세먼지가 도로변 가로수에 흡착돼 미세먼지 저감에 효과적이다. 하지만, 미세먼지는 대기 중에 부유하며 존재하고 지역별 미세먼지 농도 차이와 식재 배치 차이로 인해 때문에 미세먼지 농도 현장 측정 및 대기 중 이동 경로에 대해 예측과 도로 식재 배치 유형별 미세먼지 저감효과에 대한 규명이 어려운 실정이다. 이에 본 연구에서는 CFD 시뮬레이션을 이용하여 도로 중앙분리대와 가로수의 식재 유형별로 미세먼지 농도변화 및 미세먼지 저감효과를 분석하였다. 분석 결과 미세먼지 저감을 위해서는 중앙분리대에 식재가 있는 것이 미세먼지 저감 효과가 탁월할 것으로 보이며 가로수에 교목과 관목을 동시에 설치하는 것이 바람직하다고 판단된다. 본 결과를 바탕으로 도시 대기환경 개선을 위한 가로녹지 식재 기준(가이드라인) 마련에 효과적으로 이용될 것으로 판단되며 향후 도시 도로변 미세먼지 저감 연구 진행에 선행연구의 참고자료로 활용될 수 있을 것으로 기대된다.

성능 기준값 도출을 위한 재래식 도로절단기의 현장 절단성능 분석 (On-Site Cutting Performance Analysis of Conventional Pavement Cutter for Deriving Performance Standard Value)

  • 김균태
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.243-244
    • /
    • 2023
  • Noise, dust, etc. caused by road pavement cutting work, which frequently occurs in new construction or reconstruction of buildings, construction of complexes, etc., are environmental hazards and cause civil complaints. Recently, an eco-friendly pavement cutter is being developed to make the work low in noise and dust, however, the on-site cutting performance of the equipment has not been quantified. In this study, in order to derive a standard value for comparing the cutting performance of the eco-friendly cutter under development, a conventional pavement cutter was applied to four residential sites in Seoul and Gyeonggi-do, and the cutting data was collected. As a result of analyzing the collected data, the conventional pavement cutter showed a cutting performance of 12.3 to 20.2 sec/m, and the average was 27.2 sec/m. In the future, additional cutting experiments with various mixing ratios, materials, and depths are planned to confirm the performance of conventional pavement cutter in more detail.

  • PDF

Correction Factors for Outdoor Concentrations of PM2.5 Measured with Portable Real-time Monitors Compared with Gravimetric Methods: Results from South Korea

  • Yun, Dong-Min;Kim, Myeong-Bok;Lee, Jun-Bok;Kim, Bo-Kyeong;Lee, Dong-Jae;Lee, Seon-Yeub;Yu, Sol;Kim, Sung-Roul
    • 한국환경과학회지
    • /
    • 제24권12호
    • /
    • pp.1559-1567
    • /
    • 2015
  • This study investigated the association between $PM_{2.5}$ concentrations obtained with portable real-time monitors and those obtained with gravimetric methods in national urban air-quality monitoring sites in Seoul, South Korea. We used the SidePak AM510 Personal Aerosol Monitor (TSI Inc., 500 Cardigan Road Shoreview, MN) and DustTrak DRX 8533 (TSI Inc., 500 Cardigan Road Shoreview, MN) as portable real-time monitors for measuring $PM_{2.5}$ concentrations and compared these values with those measured with the PMS-103 or SEQ 47/50 models operated by Federal Reference Method (FRM) or the European Committee for Standardization(ECS), respectively, in national urban air-quality monitoring sites in Seoul. Measurements were conducted every other day in the winter and spring seasons of 2014. The estimated daily mean concentrations of $PM_{2.5}$ ranged between 13.4 and $161.9{\mu}g/m^3$ using AM 510 and between 22.0 and $156.0{\mu}g/m^3$ using DustTrak. The Spearman correlation coefficient for $PM_{2.5}$ concentrations between AM 510 and gravimetric results was 0.99, and the correlation between DustTrak and gravimetric results was 0.87. The correction factor suggested was 0.42 and 0.29 for AM 510 and DustTrak, respectively. We found that $PM_{2.5}$ concentrations measured with real-time monitors could overestimate true $PM_{2.5}$ concentrations and therefore the application of a correction factor (0.43) is strongly suggested for quantification when Real-time monitors were operated of $PM_{2.5}$ levels at urban atmospheric environment of South Korea.