• 제목/요약/키워드: Reversed-phase high-performance liquid chromatography

검색결과 211건 처리시간 0.03초

DHPLC를 이용한 β2-교감신경수용체 유전자에서의 돌연변이 분석 (Mutation Analysis in β2-Adrenergic Receptor Gene by Denaturing High Performance Liquid Chromatography (DHPLC))

  • 박상범;오충훈;김종완;장원철
    • 분석과학
    • /
    • 제15권3호
    • /
    • pp.190-195
    • /
    • 2002
  • 본 연구에서는 ion-pair reversed-phase high performance liquid chromatography (IP-RP-HPLC)방식을 이용한 denaturing high performance liquid chromatography (DHPLC)방법을 사용하여 기관지 천식을 조절하는 ${\beta}_2$-교감신경수용체 유전자의 돌연변이를 검출하였다. 50명의 천식 환자의 혈액에서 genomic DNA를 추출하여 중합효소연쇄반응 (polymerase chain reaction, PCR)을 이용해 증폭하고, 그 산물을 DHPLC로 분석한 결과, 50개의 시료 가운데 15개 (30%)의 돌연변이를 검출하였다. 최종적으로 유전자 염기서열결정법을 통해 DHPLC의 돌연변이 검출률이 정확함을 확인하였다.

Determination of Fluorescent Whitening Agents in Paper Materials by Ion-Pair Reversed-Phase High-Performance Liquid Chromatography

  • Kim, Jeong Soo;Kim, Do Hwan;Kim, Keon
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권12호
    • /
    • pp.3971-3976
    • /
    • 2012
  • A simple method was developed for the analysis of seven stilbene-type fluorescent whitening agents (FWAs) in paper materials by ion-pair reversed-phase high-performance liquid chromatography with fluorescence detection. These stilbene-type FWAs included two disulfonate, two tetrasulfonate, and three hexasulfonate compounds. After optimization of chromatographic conditions, the FWAs were satisfactorily separated using a reversed-phase column (RP-18) with the following isocratic mobile phase: methanol-water (60:40) containing 17.5 mM TBABr and 10 mM citrate buffer (pH = 7.0). The calibration plot was linear in the range from 5 to 500 ng/mL for two disulfo-FWAs and from 1 to 500 ng/mL for the other five FWAs. Precision levels of the calibration curve as indicated by RSD of response factors were 1.2 and 8.1%. Limits of quantitation (LOQ) ranged from 1.2 to 11 ng/mL.

Simultaneous Determination of Cysteamine and Cystamine in Cosmetics by Ion-Pairing Reversed-Phase High-Performance Liquid Chromatography

  • Kim, Yejin;Na, Dong Hee
    • Toxicological Research
    • /
    • 제35권2호
    • /
    • pp.161-165
    • /
    • 2019
  • Cysteamine has been used in cosmetics as an antioxidant, a hair straightening agent, and a hair waving agent. However, recent studies indicate that cysteamine can act as an allergen to hairdressers. The objective of this study was to develop and validate a simple and effective reversed-phase high-performance liquid chromatography (RP-HPLC) method for the measurement of cysteamine and its dimer, cystamine. Sodium 1-heptanesulfonate (NaHpSO) was used as an ion-pairing agent to improve chromatographic performance. Separation was performed on a Gemini C18 column ($250mm{\times}4.6mm$, $5{\mu}m$ particle size) using a mobile phase composed of 85:15 (v/v) 4 mM NaHpSO in 0.1% phosphoric acid:acetonitrile. UV absorbance was monitored at 215 nm. The RP-HPLC method developed in this study was validated for specificity, linearity, limit of detection, limit of quantitation, precision, accuracy, and recovery. Cysteamine and cystamine were chromatographically resolved from other reducing agents such as thioglycolic acid and cysteine. Extraction using water and chloroform resulted in the recovery for cysteamine and cystamine ranging from 100.2-102.7% and 90.6-98.7%, respectively. This validated RP-HPLC method would be useful for quality control and monitoring of cysteamine and cystamine in cosmetics.

Rapid Isolation of Cyanidin 3-Glucoside and Peonidin 3-Glucoside from Black Rice (Oryza sativa) Using High-Performance Countercurrent Chromatography and Reversed-Phase Column Chromatography

  • Jeon, Heejin;Choi, Janggyoo;Choi, Soo-Jung;Lee, Chang Uk;Yoon, Shin Hee;Kim, Jinwoong;Yoon, Kee Dong
    • Natural Product Sciences
    • /
    • 제21권1호
    • /
    • pp.30-33
    • /
    • 2015
  • Anthocyanins are water soluble plant pigments which are responsible for the blue, red, pink, violet colors in several plant organs such as flowers, fruits, leaves and roots. In recent years, anthocyanin-rich foods have been favored as dietary supplements and health care products due to diverse biological activities of anthocyanins including antioxidant, anti-allergic, anti-diabetic, anti-microbial, anti-cancer and preventing cardiovascular disease. High-performance countercurrent chromatography (HPCCC) coupled with reversed-phase medium pressure liquid chromatography (RP MPLC) method was applied for the rapid and efficient isolation of cyanidin 3-glucoside (C3G) and peonidin 3-glucoside (P3G) from black rice (Oryza sativa L., Poaceae). The crude black rice extract (500 mg) was subjected to HPCCC using two-phase solvent system composed of tert-butyl methyl ether/n-butanol/ acetonitrile/0.01% trifluoroacetic acid (TBME/B/A/0.01% TFA, 1 : 3 : 1 : 5, v/v, flow rate - 4.5 mL/min, reversed phase mode) to give enriched anthocyanin extract (37.4 mg), and enriched anthocyanin extract was sequentially chromatographed on RP-MPLC to yield C3G (16.5 mg) and P3G (8.7 mg). The recovery rate and purity of isolated C3G were 76.0% and 98.2%, respectively, and those of P3G were 58.3% and 96.3%, respectively. The present study indicates that HPCCC coupled with RP-MPLC method is more rapid and efficient than multi-step conventional column chromatography for the separation of anthocyanins.

다량 시료중 마이크로시스틴의 농축 및 분석 (Application of Reversed-Phase Solid Phase Extraction for the HPLC Analysis of Microcystins in Water)

  • 김명희;김태승;김태근;박선구
    • 분석과학
    • /
    • 제13권3호
    • /
    • pp.399-402
    • /
    • 2000
  • To determine the concentrations of microcystins present in lake water or in tap water using high performance liquid chromatography, it is necessary to concentrate a large volume of water samples (about 20 L) into very small volume (0.1-0.3 mL). Concentration can be conveniently done when disc type solid phase extraction (SPE) apparatus is used. Using this apparatus we have investigated the recovery rates of three kinds of microcystins, RR, YR, LR. The recovery rates were relatively low and the reproducibilities were not good either. It is expected, however, that the appropriate selection of the disc conditioning and eluting solvents and reproducible reconcentration process after SPE will improve both the recovery rates and the reproducibilities.

  • PDF

Efficient Isolation of Dihydrophaseic acid 3'-O-β-D-Glucopyranoside from Nelumbo nucifera Seeds Using High-performance Countercurrent Chromatography and Reverse-phased High-performance Liquid Chromatography

  • Rho, Taewoong;Yoon, Kee Dong
    • Natural Product Sciences
    • /
    • 제24권4호
    • /
    • pp.288-292
    • /
    • 2018
  • High-performance countercurrent chromatography (HPCCC) coupled with reversed-phase highperformance liquid chromatography (RP-HPLC) method was developed to isolate dihydrophaseic acid 3'-O-${\beta}$-D-glucopyranoside (DHPAG) from the extract of Nelumbo nucifera seeds. Enriched DHPAG sample (2.3 g) was separated by HPCCC using ethyl acetate/n-butanol/water system (6:4:10, v/v/v, normal-phase mode, flow rate: 4.0 mL/min) to give 23.1 mg of DHPAG with purity of 88.7%. Further preparative RP-HPLC experiment gave pure DHPAG (16.3 mg, purity > 98%). The current study demonstrates that utilization of CCC method maximizes the isolation efficiency compared with that of solid-based conventional column chromatography.

Separation and Purification of Lipase Inhibitory Peptide from Fermented Milk by Lactobacillus plantarum Q180

  • Kim, Seulki;Lim, Sang-Dong
    • 한국축산식품학회지
    • /
    • 제40권1호
    • /
    • pp.87-95
    • /
    • 2020
  • In this study, we separated and purified lipase inhibitory peptide from fermented milk by Lactobacillus plantarum Q180 with the aim of developing a new functional anti-lipase activity yogurt product. L. plantarum 180 was inoculated into 10% reconstituted skimmed milk and incubated at 37℃ until the pH of the culture reached pH 4.4. The lipase activity was measured using porcine pancreatic lipase. The lipase inhibitory peptides were gradually isolated by ultrafiltration, reversed phase column chromatography (RPC), reversed phase high-performance liquid chromatography (RP-HPLC), and gel permeation high-performance liquid chromatography (GP-HPLC) from the fermented milk by L. plantarum Q180. An ODS-AQ column was used for the RPC, a Vydac C18 column for the RP-HPLC, and a Superdex Peptide HR column for the GP-HPLC. The peptide was composed of Asp, Thr, Ile, Ser, Ala, and Gln, and the anti-lipase activity (IC50) was 2,817 ㎍/mL.

HPLC를 이용한 우유중의 클로람페니콜의 정량 분석 (Determination of Chloramphenicol in Milk by High Performance Liquid Chromatography)

  • 김경례;김정한;최경숙
    • 약학회지
    • /
    • 제29권1호
    • /
    • pp.50-54
    • /
    • 1985
  • Seven different sorbents were evaluated for their adsorptivity and desorptivity of antibiotic, chloramphenicol. Among the sorbents studied, Carbopak B was found to be the most efficient in enriching the chloramphenicol from dilute aqueous solution. Interfering components in the milk matrix could be washed off by water and petroleum ether from Carbopak B column, while the chloramphenicol was retained on the surface of Carbopak B. The method of simple and efficient purification and enrichment of chloramphenicol using Carbopak B, followed by quantitative analysis employing $C_{18}$ reversed phase high performance liquid chromatography has been applied to the determination of chloramphenicol in milk.

  • PDF

소수성 파라메터를 적용한 알킬벤젠류의 역상컬럼내의 용출거동 예측 (Prediction of Retention Behavior of Alkyl Benzenes by Hydrophobicity Parameters in Reversed-Phase Column)

  • 이창영;박명용;이용문
    • 약학회지
    • /
    • 제53권5호
    • /
    • pp.281-285
    • /
    • 2009
  • The retention of solutes in reversed-phase high-performance liquid chromatography depends on their hydrophobicity. Although the retention behaviors of alkyl benzenes have been reported so far, quite a few authors have mentioned the retention behavior of alkyl benzenes with plural hydrophobicity parameters. In this sense, we were interested in the retention behaviors of alkyl benzenes having benzene moiety and increasing alkyl chain. In this study, we therefore investigated the retention behavior of alkyl benzenes in reversed-phase high-performance liquid chromatography in order to obtain information concerning the effects of the aromatic moiety and the carbon chain on the retention mechanism by comparing their capacity factor (k') in relation to the carbon chain length. The eluent acetonitrile ($CH_3CN$) showed high selectivity on alkyl benzenes, showing the high difference of capacity factor (${\Delta}log\;k'$) between toluene and octyl benzene. Indeed, the ${\Delta}log\;k'$ of 80% $CH_3CN$ represented 1.42- and 4.25-times longer than 90% MeOH and 60% THF, respectively. The hydrophobicity parameters, van der Waals volume, bond constant, partition constant, $\pi$-energy effect and enthalpy were evaluated with the capacity factor (k') of alkyl benzenes eluted on 80% CH3CN, 90% MeOH and 60% THF, respectively. The best eluent for predicting retention behavior of alkyl benzenes was 90% MeOH ($R^2$ 0.999). The three parameters, van der Waals volume, bond constant and partition constant were well coincident to log k' by increasing alkyl benzenes. However, $\pi$-energy effect and enthalpy were severely disagreeable. Taken together, van der Waals volume, bond constant and partition constant were a reliable parameters to predict the retention behaviors of alkyl benzenes on reversed-phase column.

인삼 사포닌에서 Ginsenoside-$Rg_2$와 -$Rg_3$의 이성질체인 20(R&S) Prosapogenin들의 역상 고속 액체 크로마토그래피에 의한 분리 (Separation of 20(R&S) Prosapogenin Isomers of Ginsenoside-$Rg_2$ and -$Rg_3$ from Ginseng Saponins by Reversed-Phase High Performance Liquid Chromatography)

  • 정승일;김천석;이용구;이호섭;김일광
    • 분석과학
    • /
    • 제11권5호
    • /
    • pp.404-408
    • /
    • 1998
  • Using a reversed-phase high performance liquid chromatography, the separation of 20(S)-, 20(R)-prosapogenin stereo-isomers of ginsenoside-$Rg_2$ and of ginsenoside-$Rg_3$ in ginseng saponins has been carried out with binary solvent system. The optimum conditions for the isomer separation are as following: Nova-$Pak^{(R)}C_{18}$ (Waters, $3.9{\times}150mm$) column, $CH_3CN/CH_3CN$ (100:8, v/v) binary solvent system and the flow rate was 1.7 mL/min. The stereoisomers were separated with change of the mixture ratio of the solvent system, the solvent elution by gradient program, and then detected at 203 nm of UV detector. The simultaneous separation of mixture that were the $Rg_2$, $Rg_3$ isomers was easily performed in nonpolar solvent for $Rg_2$, polar solvent for $Rg_3$ at the same optimum conditions.

  • PDF