• Title/Summary/Keyword: Retention groove

Search Result 9, Processing Time 0.024 seconds

TWO-DIMENSIONAL FINITE ELEMENT ANALYSIS ON THE EFFECT OF INTERFACE CONDITION AND RETENTION GROOVE IN CLASS V COMPOSITE RESIN RESTORATION (5급 복합레진충전된 치아에 있어서의 계면조건과 유지구의 영향에 대한 2차원유한요소법적 연구)

  • Cho, Byeong-Hoon;Yoo, Hyeon-Mee;Kim, Dong-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.2
    • /
    • pp.639-646
    • /
    • 1998
  • To evaluate the effect of interface conditions and retention grooves in the Class V composite resin restoration of the maxillary first premolar, the distribution of the values of stress and displacement was analyzed with the two-dimensional finite element method. The results were obtained as follows : 1. Boundary elements and Stiffness values could be used as the interface parameters in the, finite element method. 2. The amount of restriction of the displacement at the cervical margin by placing a retention groove at the cervical wall was about three times as high as that by placing a retention groove at the occlusal wall. 3. Because of the relative amount of tensile components of the stress values in the bucco-lingual direction, the possibility of dislocation of the restoration was much higher at the cervical margin than at the occlusal margin. 4. It might be recommended that both occlusal and cervical retention grooves be used routinely, but if one, it be placed at the cervical wall.

  • PDF

A Study on the Adhesiveness between Polyurethane Sheet for Maxillofacial Prostheses and Autopolymerizing Acrylic Resin in Various Polymerization Methods (다양한 중합방법에 따른 악안면 보철용 폴리우레탄과 자가중합 레진 간의 결합력에 관한 연구)

  • Kim, Doo-Yeol;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.2
    • /
    • pp.123-132
    • /
    • 2000
  • The field of maxillofacial prosthetics is concerned with the prosthetic reconstruction of missing head and neck tissue. Currently, facial prostheses are usually applied in cases of defects caused by the surgical removal of tumors or congenital defects. While silicone has been most widely used for the reconstruction of missing maxillofacial defects, it does not have ideal physical properties. Therefore, bonding a thin polyurethane sheet to silicone prostheses was recommended. In this case skin adhesives were used for the retention of maxillofacial prostheses. But retention of devices has always been problematic. The contributions of implants can be made to solve these problems. Implants have reduced the need for adhesive use, simplifying cleaning procedures and thus extending the life of the prostheses. For implant-retained prostheses, retentive matrix is necessary to hold attachments and/or magnets. The retentive matrix is usually fabricated with autopolymerizing acrylic resin or visible light- polymerized resin. The purpose of this study was to compare the adhesion-in-peel force of silicone adhesive to autopolymerizing acrylic resin and polyurethane sheet with two different surface textures : pumice polish only or retention groove, and three surface primers : Dow corning 1205 primer or Dow corning S-2260 primer or FactorII A-304 primer, and two polymerization methods : room temperature or dry heat oven. The t-peel bond strength of specimens was determined as described in ASTM Standard D1876-72. The results were statistically analyzed using the ANOVA test, multiple range test and t-test The results were as follows. 1. The t-peel bond strength of A-304 primer was the highest and statistically higher than that of S-2260(p<0.05). 2. The t-peel bond strength of specimens with retention groove was statistically higher than that of specimens polished with pumice(p<0.05). 3. The t-peel bond strength of specimens polymerized in dry heat oven was statistically higher than that of specimens in room temperature(p<0.01).

  • PDF

Three-dimensional finite element analysis for the effect of retentive groove design on joint strength of casting connection (유지구 설계가 주조연결강도에 미치는 영향에 관한 삼차원 유한요소법적 연구)

  • Kim, Jung-Woo;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Mi-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.29-38
    • /
    • 2009
  • Statement of problem: A casting connection technique is widely used for repair, correction and addition to base metal framework. However, a casting connection technique may increase the risk of failure in clinical situations when high stresses exist. Purpose: The purpose of this study was to investigate the mechanical retentive groove design comparatively to increase the joint strength by using the three-dimensional finite element analysis model of a 3-unit fixed partial denture. Material and methods: Ten finite element models were constructed. (Model A: One retentive groove, Model B: Two retentive grooves, Model C: Three retentive grooves, Model D: Four retentive grooves, Model E: One horizontal groove and two vertical grooves, Model F: Two horizontal grooves and one vertical groove, Model G: One groove with the enlarged dimension, Model H: Two grooves with the enlarged dimension, Model I: One groove with the increased height, Model J: One groove with the increased width of base). The vertical force was applied to the mesial and the distal fossa to the casting connection of mandibular first molar. Results: The main factors, affecting joint strength of casting connection were both the retention between the primary cast and the secondary cast and the thickness of the primary cast remaining after preparing retentive groove. The increase of retentive force, according to the numbers and the dimension of retentive groove had an effect on distributing stress. However, in some cases, the increase of retentive force resulted in the increase of stress by reducing thickness of the primary cast in the connection area. Conclusion: The design of retentive groove that limits number of retentive groove for metal thickness and increases the depth of retentive groove for retention is highly recommended.

A STUDY ON COMPARISON OF VARIOUS KINDS OF CLASSII AMALGAM CAVITIES USING FINITE ELEMENT METHOD (유한요소법을 이용한 수종 2급 아말감 와동의 비교연구)

  • Seok, Chang-In;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.432-461
    • /
    • 1995
  • The basic principles in the design of Class II amalgam cavity preparations have been modified but not changed in essence over the last 90 years. The early essential principle was "extension for prevention". Most of the modifications have served to reduce the extent of preparation and, thus, increase the conservation of sound tooth structure. A more recent concept relating to conservative Class II cavity preparations involves elimination of occlusal preparation if no carious lesion exists in this area. To evaluate the ideal ClassII cavity preparation design, if carious lesion exists only in the interproximal area, three cavity design conditions were studied: Rodda's conventional cavity, simple proximal box cavity and proximal box cavity with retention grooves. In this study, MO amalgam cavity was prepared on maxillary first premolar. Three dimensional finite element models were made by serial photographic method. Linear, eight and six-nodal, isoparametric brick elements were used for the three dimensional finite element model. The periodontal ligament and alveolar bone surrounding the tooth were excluded in these models. Three types model(B option, Gap option and R option model) were developed. B option model was assumed perfect bonding between the restoration and cavty wall. Gap option model(Gap distance: $2{\mu}m$) was assumed the possibility of play at the interface simulated the lack of real bonding between the amalgam and cavity wall (enamel and dentin). R option model was assumed non-connection between the restoration and cavty wall. A load of 500N was applied vertically at the first node from the lingual slope of the buccal cusp tip. This study analysed the displacement, 1 and 2 direction normal stress and strain with FEM software ABAQUS Version 5.2 and hardware IRIS 4D/310 VGX Work-station. The results were as followed. 1. Rodda's cavity form model showed greater amount of displacement with other two models. 2. The stress and strain were increased on the distal marginal ridge and buccopulpal line angle in Rodda's cavity form model. 3. The stress and strain were increased on the central groove and a part of distal marginal ridge in simple proximal box model and proximal box model with retention grooves. 4. With Gap option, Rodda's cavity form model showed the greatest amount of the stress on distal marginal ridge followed by proximal box model with retention grooves and simple proximal box model in descending order. 5. With Gap option, simple proximal box model showed greater amount of stress on the central groove with proximal box model with retention grooves. 6. Retention grooves in the proximal box played the role of supporting the restorations opposing to loads.

  • PDF

THE INFLUENCE OF RETENTIVE GROOVE ON THE CANAL WALL UPON THE RETENTION OF POST (근관벽(根管壁) 유지구(維持溝)가 Post의 유지력(維持力)에 미치는 영향(影響))

  • Lee, Jae-Whan;Cho, Kyew-Zeung
    • Restorative Dentistry and Endodontics
    • /
    • v.12 no.2
    • /
    • pp.111-116
    • /
    • 1987
  • The experimental study was made to evaluate the influence of retentive grooves on the canal wall upon the retention of post, using different type of cements. Ninety periodontally involved anterior teeth were extracted and divided into six groups of 15 teeth. The groups were labeled as follows: Group I: Dentatus post cemented zincphosphate cement into post hole with smooth wall. Group II: Dentatus post cemented with zincphosphate cement into post hole with retentive grooves. Group III: Dentatus post cemented with glass-ionomer cement into post hole with smooth wall. Group IV: Dentatus post cemented with glass-ionomer cement into post hole with retentive grooves. Group V: Dentatus post cemented with composite resin adhesive into post hole with smooth wall. Group VI: Dentatus post cemented with composite resin adhesive into post hole with retentive grooves. The tensile strength was tested by an Instron type tester with cross-head speed of 5mm per minute. The results were as follows: In the group without retentive grooves, three kinds of cement have little effect upon retentive capacity of Dentatus post. The Dentatus post cemented on the canal wall with retentive grooves is more retentive than Dentatus post without retentive grooves.

  • PDF

A study on the changes of the posterior segments between before, after treatment and postretention period through maxillary expansion therapy (상악궁 확장술을 통한 치료전, 후 및 보정후 상악 구치부 변화에 관한 연구)

  • Park, Tae-Seo;Lee, Jin-Woo;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.55-63
    • /
    • 1997
  • The purpose of thus study was to measure the changes of arch and dentition of maxillary posterior teeth before and after treatment and postretentios in patients treated with Quad-helix. Measurements and analysis were performed on study model with carlipers. Seventeen cases, eight boys and nine girls, were selected with average ages of 12.7 years. Mean retention period was 4 months, and mean wearing time was. 127 days. The result were as follows 1. The interpremolar widths and intermolar width were significantly increased in maxillary first piennolar and molar when compared between before and after treatment and postretention. The maxillary second premolar resulted in significant increase in interpremolar between after tretment and post retention. 2. The long axis of maxillary first premolar and first molar accompaning buccal tipping was significant increased before and after Tx and post retention. Significant increase of the lingual inclination of maxillary second premolar was obsered both in before and after Tx, and before Tx and post retention. 3. The distance between the height of tooth contour was significantly increased in the first and second premolar before and after Tx, and was significant increased in the first molar before and after Tx and post retention. 4. Intermolar width at the palatal groove was increased in before and after Tx. and post retention. The palatal depth was significant increased in before and after Tx. In conclusion expansion of maxillary dental arch showed no relapse and results were stable retention

  • PDF

PROSPECTIVE CLINICAL EVALUATION OF THREE DIFFERENT BONDING SYSTEMS IN CLASS V RESIN RESTORATIONS WITH OR WITHOUT MECHANICAL RETENTION (접착제와 와동형성의 차이에 따른 5급 복합레진 수복의 전향적 임상연구)

  • Lee Kyung-Wook;Choung Sae-Joon;Han Young-Chul;Son Ho-Hyun;Um Chung-Moon;Oh Myoung-Hwan;Cho Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.4
    • /
    • pp.300-311
    • /
    • 2006
  • The purpose of this study is to evaluate prospectively the effect of different bonding systems and retention grooves on the clinical performance of resin restorations in non-carious cervical lesions (NCCLs). Thirty-nine healthy adults who had at least 2 NCCLs in their premolar areas were included in this study. One hundred and fifty teeth were equally assigned to six groups: (A) Scotchbond Multi-Purpose (SBMP, 3M ESPE, St. Paul, MN, USA, 4th generation bonding system) without retention grooves; (B) SBMP with retention grooves; (C) BC Plus (Vericom Co., Anyang, Gyeonggido, Korea, 5th generation bonding system) without retention grooves; (D) BC Plus with retention grooves; (E) Adper Prompt (3M ESPE, Seefeld, Germany, 6th generation bonding system) without retention grooves; (F) Adper Prompt with retention grooves. All cavities were filled with a hybrid composite resin. Denfil (Vericom Co., Anyang, Gyeonggido, Korea) by one operator. Restorations were evaluated at baseline and at 6-month recall, according to the modified USPHS (United States Public Health Service) criteria. Additionally, clinical photographs were taken and epoxy resin replicas were made for SEM evaluation. At 6-month recall, there were some differences in the number of alpha ratings among the experimental groups. But, despite the differences in the number of alpha ratings, there was no significant difference among the 3 adhesive systems (p < 0.05). There was also no significant difference between the groups with or without mechanical retention (p < 0.05). Follow-ups for longer periods than 6 months are needed to verify the clinical performance of different bonding systems and retention grooves.

Maxillary complete denture fabrication cases with posterior palatal seal considering palatal form and tissue displacement (구개 형태 및 조직 변위를 고려하여 후방 구개 폐쇄를 형성한 상악 총의치 제작 증례)

  • Kim, Seon-A;Son, Mee-Kyung;Heo, Yu-Ri
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.152-159
    • /
    • 2022
  • The role of the posterior palatal seal is important in retention of the maxillary complete denture. After taking the final impression, additional retention can be given to the maxillary denture through a mechanical method of forming a groove on master cast, but this is often overlooked in the clinical process. As a result, the posterior palatal seal is formed in a uniform way by the technician without considering the individual characteristics of the patient. Until now, various types of posterior palatal seal have been introduced by many people. This case report describes the process of manufacturing the maxillary complete denture by determining the position and form of an appropriate posterior palatal seal after considering the patient's anatomical palatal form and tissue displacement during function.

A Study on Electro-deposited Multi-layered Diamond Tool for Grinding Sapphire Wafers (사파이어 절삭용 다층 전착 다이아몬드 공구에 대한 연구)

  • Lim, Goun;Song, William;Hong, Joo Wha
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.30 no.5
    • /
    • pp.222-226
    • /
    • 2017
  • Recently sapphire wafer has expected as smart phone cover material, however, brittle nature of sapphire needed edge grinding processes to prevent early initiation of cracks. Electro-deposited multi-layered groove tools with $35{\mu}m$ diamond particles were studied for sapphire wafer grinding. Solid particle flow behaviors in agitated electrolyte was studied using PIV(Particle Image Velocimetry), and uniform particle distribution in Ni bond were obtained when agitating impeller was located lower part of electrolyte. Hardness values of $400{\pm}50Hv$ were maintained for retention of diamond particles in electro-deposited bond layer. Sapphire wafer edge grinding test was carried out and multi-layered $160{\mu}m$ thick diamond tool showed much greater grinding capabilities up to 2000 sapphire wafers than single-layered $50{\mu}m$ thick diamond electro-deposited tools of 420 wafers. The reason why 3 times thicker multi-layered tools than single-layered tools showed 5 times longer tool lives in grinding processes was attributed to self-dressed new diamond particles in multi-layered tools, and multi-layered diamond tools could be promising for sapphire grinding.