• 제목/요약/키워드: Restorer

검색결과 106건 처리시간 0.046초

리튬 배터리를 연계한 100kVA UPQC 개발 및 성능시험 (The Development and Experimental Evaluation of 100kVA Unified Power Quality Conditioner interconnected to the Li-Battery System)

  • 이학주;채우규;박중성;손진만;최은식
    • 조명전기설비학회논문지
    • /
    • 제26권10호
    • /
    • pp.102-110
    • /
    • 2012
  • This paper propose the advanced topology of UPQC, its DC link is connected with Lithium battery, to compensate the momentary interruptions. The proposed system can be operated as UPS mode using the parallel inverter, which control the charge or discharge of battery, in case of the interruption. We dvelop 100kVA UPQC using the proposed topology to rise the power quality and the reliability of Microgrid. We verify its usefulness through voltage compensation test, UPS operation test and etc. using Microgrid test facility.

Line-Interactive 전압보상기에 관한 연구 (A Study of Line-Interactive UPS with Voltage Compensator)

  • 우성민;강대욱;이우철;최창호;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.487-490
    • /
    • 2001
  • Power Quality and Reliability are becoming important issues for critical and sensitive loads. This paper describes the Line Interactive UPS with the function of Voltage Compensator that is 'Line interactive Dynamic Voltage Restorer(LIDVR). The main purpose of a LIDVR is to compensate for voltage sag(dip), outage and overvoltage. The overall system consists of three controller 1) current controller with prediction 2) voltage controller and 3) proposed variable DC LINK controller. The variable DC LINK control technique using the LIDVR protects DC LINK from overflowing the input current. The simulation results are depicted in this paper to show the effect of this proposed system.

  • PDF

세포질 유전자적 웅성불임계통을 이용한 유체 Heterosis 육종 개발에 관한 연구 제2보 웅성불임계통에 Non-Isogenic Maintainer를 활용한 유체 3원교잡F_1의 형질발현과 F_1종자생육 (Studies on Heterosis Breeding in Rapeseed Using Cytoplasmic Male Sterility 2, Agronomic Characteristics of F_1 Seed Production Procedure in the Three-way Crossing of Cytoplasmic-genetic Male Sterile, Non-Isogenic Maintainer and Restorer on Rape (Brassica napus L.))

  • 이정일;권병선
    • 한국작물학회지
    • /
    • 제25권2호
    • /
    • pp.49-57
    • /
    • 1980
  • A $F_1$ hybrid out of 143 crosses of rape (Brassica napus) using cytoplasmic-genetic male sterility yielded 5.18 tons per hectare. European and native varieties used, were found out to have 78% and 58% of genes restoring fertility, respectively. The $F_1$ hybrids of three way cross using non-isogenic maintainer showed higher heteroses than those of double cross. To produce F 1 hybrids of three way cross, three stages of crossing operations are needed and seeds produced from about 60 hectares can be covered to 60, 000 hectares.

  • PDF

재귀형 최소 자승법을 이용한 동적 전압 보상기의 순시전압강하 검출 (Instantaneous Voltage Sag Detection for Dynamic Voltage Restorer using Recursive Least Square Method)

  • 지균선;주성탁;이교범
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.134-135
    • /
    • 2014
  • 본 논문에서는 동적 전압 보상기를 위한 속응성을 향상시킨 입력 전압의 크기를 검출하는 기법을 제안한다. 동적 전압 보상기가 계통 전압에서 발생한 순시전압강하를 보상하기 위해서는 강하된 전압을 검출해야 한다. 외란에 강인하고 빠른 응답 특성을 가지는 재귀형 최소 자승법을 사용하여 입력 전압으로 부터 강하된 전압의 크기를 구하고 보상전압을 생성한다. 생성된 보상전압은 입력 전압에 더해져 안정된 부하전압을 공급한다. 시뮬레이션 결과를 통해 제안하는 방법의 타당성을 검증한다.

  • PDF

개선된 전압계측법에 의한 off-line type 동적전압보상기의 개발 (Off-line Type Dynamic Voltage Restorer Development by improved Voltage measuring method)

  • 한종희;오중민;손진근;전희종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1096-1098
    • /
    • 2007
  • 본 논문에서는 효율면에서 많은 장점을 가진 Off-line Type DVR을 개발하는데 있어서 중요한 문제인 순시적 전압강하 및 위상각 검출에 대한 개선된 계측 기법에 관한 연구를 수행하였다. 상시 가동되는 On-line Type과는 다르게 순시적 전압강하나 순간정전이 발생시에만 동작하는 Off-line Type DVR은 검출부의 정밀함이 전체 시스템의 신뢰도를 결정한다. 따라서, 본 논문에서는 순시적 전압강하 및 위상각 검출에 있어서 개선된 계측 기법을 제시하고, EDLC를 채용한 5[kVA] 용량의 DVR을 개발하여 그 실험 및 검증 결과를 제시한다.

  • PDF

22.9kV 배전선로 적용을 위한 DVR 제어시스템 설계 (DVR Control System Design applied to 22.9kV Distribution System)

  • 김희중;정용호;권기현;박태범;전영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.30-32
    • /
    • 2004
  • This paper describes control system design for the DH(dynamic voltage restorer) consisted of a diode rectifier and series inverter applied to 22.9kV distribution system. The DVR control system is consisted of the main two parts. One is a voltage event detector using a neural network and the other is deadbeat controller for the output voltage and current control of the DVR. A simulation model was developed for analyzing performance of the controller and the whole system. The results confirm that the DVR can restore load voltage under the fault of the distribution system.

  • PDF

Implementation of a Non-Linear Adaptive Filter Based Sag Detection Method for Dynamic Voltage Restorers under Unbalanced Fault Conditions

  • Cuma, M. Ugras;Teke, Ahmet;Meral, M. Emin;Bayindir, K. Cagatay;Tumay, Mehmet
    • Journal of Power Electronics
    • /
    • 제13권2호
    • /
    • pp.304-312
    • /
    • 2013
  • The most common power quality problems in distribution systems are related to unbalanced voltage sags. Voltage sags must be detected quickly and corrected in a minimum amount of time. One of the most widely used methods for sag detection is based on the d-q transformation. This method has the disadvantage of missing the detection of unbalanced faults, because this method uses a voltage sag level signal obtained from the average of 3 phases for sag detection. In this paper, an adaptive filter sag detection method is proposed for Dynamic Voltage Restorers (DVR) under unbalanced fault conditions. The proposed DVR controller is able to detect balanced, unbalanced and single phase voltage sags. A novel reference voltage generation method is also presented. To validate the proposed control methods, a 3-phase DSP controlling a DVR prototype with a power rating of 1.5-kVA has been developed. Finally, experimental results are presented to verify the performance of the proposed control methods.

멀티-레벨 H-Bridge 인버터를 이용한 Line-Interactive DVR (Line-Interactive DVR Using Multi-Level H-Bridge Inverter)

  • 강대욱;우성민;김태진;최창호;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 추계학술대회 논문집
    • /
    • pp.139-143
    • /
    • 2001
  • Recently, the interest on power quality has been hot issue. The equipments cause voltage disturbance and has become more sensitive to the voltage disturbance. This paper deals with 5-Level H-Bridge Line-Inter active Dynamic Voltage Restorer(LIDVR) system. The LIDVR has following advantages in comparison with the DVR with series injection transformer It has the power factor near to unity under normal source voltage, can compensate the harmonic current of the load and the instant interruption, and has the fast response. First, the construction, the operation mode and algebraic modeling of LIDVR are reviewed. And then a voltage controller is proposed to get sinusoidal load voltage with constant amplitude. To find PWM method suitable for H-Bridge converter, two PWM methods are compared and analyzed. Finally, simulation results verify the proposed 5-level H-Bridge LIDVR system.

  • PDF

TCR을 이용한 Voltage Sag와 Swell 발생장치에 대한 연구 (Voltage Sag and Swell Generator with Thyristor Controlled Reactor)

  • 박태범;권기현;정용호;이진;임계영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.25-27
    • /
    • 2002
  • This paper describes a new economical voltage sag and swell generator suitable to the evaluations of high power custom power devices such as DVR (Dynamic Voltage Restorer) and DSTATCOM (Distribution Static Compensator). This system was designed to generate the several power quality disturbances in MVA power ratings - voltage sag and swell, under voltage, over voltage and harmonic distortions. The basic idea for voltage sag and swell is to use the voltage drop across a reactor, while the voltage swell is to use the step-up transformer and the TCR(Thyristor Controlled Reactor). In this paper, two identical 3 phase TCRs and a step-up transformer with tap changer are used. Additional harmonic filters are added to reduce the voltage distortion when TCRs are operated. Simulation results are given for several cases of voltage sag and swell generations.

  • PDF

3상 위상제어 정류기에서 DVR의 응답시간과 허용 가능한 순시저전압의 범위에 대한 연구 (A study on the permissible range of voltage dips and the response time of DVR in 3-phase phase-controlled rectifier)

  • 한무호;권우현;박철우
    • 제어로봇시스템학회논문지
    • /
    • 제10권4호
    • /
    • pp.325-333
    • /
    • 2004
  • It is investigated that the relation between the response time of DVR(Dynamic Voltage Restorer) and the possible compensation range of voltage dip by the DVR system which protects the 3-phase phase-controlled rectifier from voltage dip. As a result, the permissible range of voltage dip is presented in the 3-phase phase-controlled rectifier, and it is presented that the range of voltage dip which can be compensated according to the DVR s response time. when the DVR compensates voltage dip, Using the proposed method, the DVR s response time can be determined from the parameters of 3-phase phase-controlled rectifier and the possible compensation range of voltage dip, and it is possible to use the control system which have an appropriate speed. Therefore, the use of excessively fast device can be avoided, and the stability of the overall system is improved. Also the reliance of DVR about the 3-phase phase-controlled rectifier can be verified.