• Title/Summary/Keyword: Response regulator

Search Result 387, Processing Time 0.03 seconds

Dynamic Behavior Analysis of variable Displacement Control Valve for Closed Circuit Piston Pump (피스톤 펌프 정/역 가변토출 제어밸브의 동적거동 해석)

  • 유진산;함영복;윤소남;김성동
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.721-724
    • /
    • 2002
  • This study deals with a dynamic behavior analysis of pump control regulator varied the swash plate tilting angle with the positive and negative direction. To accomplish it's purpose, modeling and displacement response analysis about principal parts (spool, servo piston, feedback lever, sleeve) of pump control regulator was performed. We have been able to verifying the propriety of servo mechanism and design parameters of pump control regulator by research results. So, it respect to utilized with useful research data at variable displacement control valve development of variable displacement piston pump.

  • PDF

Design and Performance Analysis of PID type Controllers for Automatic Voltage Regulator(AVR) System Based on i-PID, GPI and OCD Methods (AVR(Automatic Voltage Regulator)시스템을 위한 PID형 제어기의 설계 -i-PID, GPI 및 OCD 알고리즘을 중심으로 -)

  • Choe, Yeon-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.8
    • /
    • pp.1383-1391
    • /
    • 2016
  • This paper is concerned with applicability of a new type of controllers, called i-PID and GPI in which unknown parts of the plant are taken into account without any modeling procedure, to automatic voltage regulator (AVR) system. First, the procedure for applying i-PID and GPI algorithms to AVR system is proposed, which uses model reduction technique based on the given information of AVR. Second, simulations are given to verify their effectiveness comparing to various PID algorithms including PIDD2 which is four-term controller, that is, consisting of PID and second order derivative terms. Superior response performances of i-PID and GPI in comparison to conventional PID controllers are shown. Moreover, i-PID can highly improve the system robustness with respect to model uncertainties, especially to load variations.

CaPUB1, a Hot Pepper U-box E3 Ubiquitin Ligase, Confers Enhanced Cold Stress Tolerance and Decreased Drought Stress Tolerance in Transgenic Rice (Oryza sativa L.)

  • Min, Hye Jo;Jung, Ye Jin;Kang, Bin Goo;Kim, Woo Taek
    • Molecules and Cells
    • /
    • v.39 no.3
    • /
    • pp.250-257
    • /
    • 2016
  • Abiotic stresses such as drought and low temperature critically restrict plant growth, reproduction, and productivity. Higher plants have developed various defense strategies against these unfavorable conditions. CaPUB1 (Capsicum annuum Putative U-box protein 1) is a hot pepper U-box E3 Ub ligase. Transgenic Arabidopsis plants that constitutively expressed CaPUB1 exhibited drought-sensitive phenotypes, suggesting that it functions as a negative regulator of the drought stress response. In this study, CaPUB1 was over-expressed in rice (Oryza sativa L.), and the phenotypic properties of transgenic rice plants were examined in terms of their drought and cold stress tolerance. Ubi:CaPUB1 T3 transgenic rice plants displayed phenotypes hypersensitive to dehydration, suggesting that its role in the negative regulation of drought stress response is conserved in dicot Arabidopsis and monocot rice plants. In contrast, Ubi:CaPUB1 progeny exhibited phenotypes markedly tolerant to prolonged low temperature ($4^{\circ}C$) treatment, compared to those of wild-type plants, as determined by survival rates, electrolyte leakage, and total chlorophyll content. Cold stress-induced marker genes, including DREB1A, DREB1B, DREB1C, and Cytochrome P450, were more up-regulated by cold treatment in Ubi:CaPUB1 plants than in wild-type plants. These results suggest that CaPUB1 serves as both a negative regulator of the drought stress response and a positive regulator of the cold stress response in transgenic rice plants. This raises the possibility that CaPUB1 participates in the cross-talk between drought and low-temperature signaling pathways.

Electro-pneumatic regulator using multilayer PZT actuator (적층형 압전액추에이터 방식 전-공 레귤레이터)

  • Yun, So-Nam;Kim, Chan-Yong;Park, Jung-Ho;Youn, Dong-Won
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.979-984
    • /
    • 2007
  • This paper presents a new control mechanism for the proportional pressure control which is accomplished by electro-pneumatic regulator using two PZT actuators. The electro-pneumatic regulator of this study is 2-stage type and consists of two piezoelectric actuators, a controller and a main poppet valve. The piezoelectric actuators are multilayer bender type and are controlled by digital signal. Proportional pressure control technique is very important because that can derive improvement of product quality and driving ability in the pneumatic system. Solenoid actuator method for pressure control is widely used but this actuator has a high power consumption characteristics. So new actuator is required for the energy saving. In this study, PZT actuator for the pressure control was fabricated and experimented instead of the conventional type solenoid actuator. Experiments for the new control mechanism of the elector-pneumatic regulator were operated under the input condition of 0.4[MPa] and it was confirmed that this mechanism has a good control characteristics to the response sensitivity and hysteresis.

  • PDF

High precision Automatic Voltage Regulator by using series transformer (직렬 변압기를 이용한 고정밀 자동전압조절기)

  • Zhang, Lei;Lee, Hwa-Chun;Jung, Tae-Uk;Nam, Hae-Kon;Nam, Soon-Ryul;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.574-576
    • /
    • 2008
  • Now there are two types Non-contact compensation AC automatic voltage regulator (A.V.R). One is transformer compensation regulator, whose principle is the combination of multiple compensation transformers, do the compensation by turning on and off the connections of the transformer through the multi-full bridge circuit. This method removed the mechanical drive and contacts, which increases the life and the dynamic performance of the A.V.R. However, the compensation is multilevel, and it needs many compensation transformers and switches, the circuit is complex, the compensation precision is low. Another type is PWM switch AC regulator, whose principle is getting the AC voltage from the input, then induce the AC compensation voltage through commutating and high frequency PWM transforming, and phase tracking. Here the compensation is step-less, the compensation precision is high, and the response is fast. But the circuit is complex, and it needs an inverse compensation transformer, which is difficult to realize high-power applications. In this paper, it shows an Automatic Voltage Regulator which use high frequency PWM inverter do compensation. This A.V.R has the function as the custom-power, which make the performance of the power supply in a high level.

  • PDF

A Low Drop Out Regulator with Improved Load Transient Characteristics and Push-Pull Pass Transistor Structure (Push-Pull 패스 트랜지스터 구조 및 향상된 Load Transient 특성을 갖는 LDO 레귤레이터)

  • Kwon, Sang-Wook;Song, Bo Bae;Koo, Yong-Seo
    • Journal of IKEEE
    • /
    • v.24 no.2
    • /
    • pp.598-603
    • /
    • 2020
  • In this paper present a Low Drop-Out(LDO) regulator that improves load transient characteristics due to the push-pull pass transistor structure is proposed. Improved load over the existing LDO regulator by improving the overshoot and undershoot entering the voltage line by adding the proposed push-pull circuit between the output stage of the error amplifier inside the LDO regulator and the gate stage of the pass transistor and the push-pull circuit at the output stage. It has a delta voltage value of transient characteristics. The proposed LDO structure was analyzed in Samsung 0.13um process using Cadence's Virtuoso, Spectre simulator.

Phosphate Deficiency Stress Response Mediated by Pho Regulon in Bacillus subtilis (Bacillus subtilis의 Pho Regulon을 통한 인산 결핍 스트레스 반응)

  • Park, Jae-Yong
    • Korean Journal of Microbiology
    • /
    • v.46 no.2
    • /
    • pp.113-121
    • /
    • 2010
  • Bacillus subtilis PhoP-PhoR two-component system (TCS) senses phosphate deficiency conditions, and then controls expression of the Pho regulon to prolong survival. The sensor histidine kinase, PhoR, is autophosphorylated and transfers the phosphate to the response regulator, PhoP. Phosphorylated PhoP (PhoP~P) binds to repeated 6-bp consensus PhoP binding sequences of Pho regulon promoters and activates or represses gene expression. Pho signal transduction systems are part of interconnected signal transduction network involving at least three TCSs (PhoP-PhoR, ResD-ResE TCS, SpoOA phosphorelay), a global carbon metabolism regulator (CcpA), and transition state regulators (AbrB, ScoC). In addition, PhoP-PhoR TCS is cross related with YycF-YycG TCS by cross-regulation. While indescribable progress has been made in understanding phosphate deficiency stress response through refined expression of the Pho regulon in the recent past years, many important questions still remain. Solving these questions may provide important information for application study using B. subtilis.

A Capacitorless Low-Dropout Regulator With Enhanced Response Time (응답 시간을 향상 시킨 외부 커패시터가 없는 Low-Dropout 레귤레이터 회로)

  • Yeo, Jae-Jin;Roh, Jeong-Jin
    • Journal of IKEEE
    • /
    • v.19 no.4
    • /
    • pp.506-513
    • /
    • 2015
  • In this paper, an output-capacitorless, low-dropout (LDO) regulator is designed, which consumes $4.5{\mu}A$ quiescent current. Proposed LDO regulator is realized using two amplifier for good load regulation and fast response time, which provide high gain, high bandwidth, and high slew rate. In addition, a one-shot current boosting circuit is added for current control to charge and discharge the parasitic capacitance at the pass transistor gate. As a result, response time is improved during load-current transition. The designed circuit is implemented through a $0.11-{\mu}m$ CMOS process. We experimentally verify output voltage fluctuation of 260mV and recovery time of $0.8{\mu}s$ at maximum load current 200mA.

Design of LDO Regulator with Two Output (두 개의 출력을 갖는 LDO 레귤레이터 설계)

  • Kwon, Min-Ju;Kim, Chea-Won;Kwak, Jae-Chang
    • Journal of IKEEE
    • /
    • v.21 no.2
    • /
    • pp.154-157
    • /
    • 2017
  • This paper proposes the Low-Dropout regulator with two output. Each of the two output has feedback, and shared feedback loop. PMOS is added to solve the problem the occur when sharing the feedback loop. Thus eased the Load Transient Response. Also Using one of the bias citcuit and one of the pass transistor, Area is reduce by half compared to Existing Area that used to obtain output of two output.

Active neuro-adaptive vibration suppression of a smart beam

  • Akin, Onur;Sahin, Melin
    • Smart Structures and Systems
    • /
    • v.20 no.6
    • /
    • pp.657-668
    • /
    • 2017
  • In this research, an active vibration suppression of a smart beam having piezoelectric sensor and actuators is investigated by designing separate controllers comprising a linear quadratic regulator and a neural network. Firstly, design of a smart beam which consists of a cantilever aluminum beam with surface bonded piezoelectric patches and a designed mechanism having a micro servomotor with a mass attached arm for obtaining variations in the frequency response function are presented. Secondly, the frequency response functions of the smart beam are investigated experimentally by using different piezoelectric patch combinations and the analytical models of the smart beam around its first resonance frequency region for various servomotor arm angle configurations are obtained. Then, a linear quadratic regulator controller is designed and used to simulate the suppression of free and forced vibrations which are performed both in time and frequency domain. In parallel to simulations, experiments are conducted to observe the closed loop behavior of the smart beam and the results are compared as well. Finally, active vibration suppression of the smart beam is investigated by using a linear controller with a neural network based adaptive element which is designed for the purpose of overcoming the undesired consequences due to variations in the real system.