• Title/Summary/Keyword: Resorbable blasting media

Search Result 24, Processing Time 0.02 seconds

3-Year Survival Analysis of RBM and Acid-Etched Surface Implants (RBM 표면 임플란트와 산부식 표면 임플란트의 3년 생존율에 대한 비교 연구)

  • Yoon, Dae-Woong;Kim, Moon-Seob;Jang, Han-Seung;Jin, Soo-Young;Mah, Deuk-Hyun;Jeong, Gyeong-Dal;Park, Hyun-Chun;Kim, Hee-Jung;Kim, Hak-Kyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.4
    • /
    • pp.393-403
    • /
    • 2011
  • The purpose of this study was to analyze and compare survival rates of resorbable blast media(RBM) surface and acid-etched surface implants being usually used in clinics. RBM surface implants (USII, Osstem, Busan, Korea) or acid-etched surface implants ($Osseotite^{(R)}$, Biomet $3i^{[TM]}$, FL, USA) were placed in edentulous area of 140 patients between January of 2005 and March of 2007. The number of implants was 304, and 152 out of them were RBM surface implants while another 152 were acid-etched surface implants. According to the evaluation items, the survey was performed before and after the implants installations. The 3-year survival rates of both kind of implants were calculated. 1. Total of 152 RBM surface implants were placed. Among them, one implant was failed, which was implanted in the posterior mandible with D2 bone quality. The failure was resulted from fracture of the fixture. Others showed good results and survival rate of RBM surface implant was 99.34%. 2. Total of 152 acid-etched surface implants were placed. Seven implants of them were failed, thus, survival rate was 95.39%. The causes of the failures were considered as infection, overheat and the lack of initial stability. In this research, both implants showed good 3-year survival rate, although RMB surface implant represented a better result.

Evaluation of titanium surface properties by $Nd:YVO_4$ laser irradiation: pilot study ($Nd:YVO_4$ 레이저 조사에 따른 티타늄의 표면특성 평가: 예비 연구)

  • Kim, Ae-Ra;Park, Ji-Yoon;Kim, Yeon;Jun, Sei-Won;Seo, Yoon-Jeong;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.167-174
    • /
    • 2013
  • Purpose: This study was conducted to evaluate the roughness and surface alternations of three differently blasted titanium discs treated by $Nd:YVO_4$ Laser irradiation in different conditions. Materials and methods: Thirty commercially pure titanium discs were prepared and divided into three groups. Each group was consisted of 10 samples and blasted by $ZrO_2$ (zirconium dioxide), $Al_2O_3$ (aluminum oxide), and RBM (resorbable blasted media). All the samples were degreased by ultrasonic cleaner afterward. Nine different conditions were established by changing scanning speed (100, 300, 500 mm/s) and repetition rate (5, 15, 35 kHz) of $Nd:YVO_4$ Laser (Laser Pro D-20, Laserval $Korea^{(R)}$, Seoul, South Korea). After laser irradiation, a scanning electron microscope, X-ray diffraction analysis, energy dispersive X-ray spectroscopic analysis, and surface roughness analysis were used to assess the roughness and surface alternations of the samples. Results: According to a scanning electron microscope (SEM), titanium discs treated with laser irradiation showed characteristic patterns in contrast to the control which showed irregular patterns. According to the X-ray diffraction analysis, only $Al_2O_3$ group showed its own peak. The oxidation tendency and surface roughness of titanium were similar to the control in the energy dispersive X-ray spectroscopic analysis. The surface roughness was inversely proportional to the scanning speed, whereas proportional to the repetition rate of $Nd:YVO_4$. Conclusion: The surface microstructures and roughness of the test discs were modified by the radiation of $Nd:YVO_4$ laser. Therefore, laser irradiation could be considered one of the methods to modify implant surfaces for the enhancement of osseointegration.

A resonance frequency analysis of sandblasted and acid-etched implants with different diameters: a prospective clinical study during the initial healing period

  • Kim, Hyun-Joo;Kim, Yeun-Kang;Joo, Ji-Young;Lee, Ju-Youn
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.2
    • /
    • pp.106-115
    • /
    • 2017
  • Purpose: The possibility of immediate or early loading has become popular in implant dentistry. A prerequisite for the immediate or early loading of an implant prosthesis is the achievement of initial stability in the implant. Moreover, in response to clinicians' interest in verifying clinical stability to determine the optimal time point for functional loading, a non-invasive method to assess implant stability has been developed on the basis of resonance frequency analysis (RFA). The primary objective of this study was to monitor the stability of sandblasted, large-grit, and acid-etched (SLA) implants with different diameters during the early phases of healing by RFA. The secondary objective was to evaluate how the initial stability of implants varied depending on different surface modifications and other contributing factors. Methods: Thirty-five implants (25 SLA implants and 10 resorbable blasting media [RBM] implants) placed in 20 subjects were included. To measure implant stability, RFA was performed at baseline and at 1, 2, 3, 4, 6, and 10 weeks after surgery. Results: The longitudinal changes in the implant stability quotient (ISQ) values were similar for the SLA implants with different diameters and for the RBM implants. During the initial healing period, the ISQ decreased after installation and reached its lowest values at 1 week and 2 weeks, respectively. The mean ISQ values in the SLA implants were significantly higher in ${\varnothing}5.0mm$ implants than in ${\varnothing}4.0mm$ implants. Men showed a higher ISQ than women. Mandibular sites showed a higher ISQ than maxillary sites. Conclusions: All implants used in this study are suitable for immediate or early loading under appropriate indications. A wider diameter and SLA surface treatment of implants could improve the stability, if the implant is fixed with at least 30 Ncm of insertion torque.

The effect of conditioning by Tetracycline-Hcl on implant surface;The SEM study and. surface roughness measurements : RBM surface (염산 테트라싸이클린이 RBM적용 임프란트 표면구조에 미치는 영향의 미세구조 및 표면 거칠기 변화에 관한 연구)

  • Lim, Hae-Soo;Park, Joon-Bong;Kwon, Young-Hyuk;Herr, Yeek;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.3
    • /
    • pp.585-597
    • /
    • 2007
  • The present study was performed to evaluate the effect of Tetracycline-HCI and Saline on the change of implant surface microstructure and surface roughness according to application time. Implants with resorbable blasting media surface were utilized. Before test all 13 implants were measured surface roughness. Among them, 6 implants were rubbed with 50mg/ml Tetracycline-HCl solution and other 6 implants with saline for $\frac{1}{2}$min., 1min., $1\frac{1}{2}$min., 2min., $2\frac{1}{2}$min and 3min. Then, specimens were processed for scanning electron microscopic observation and surface roughness after test. The results of this study were as follows. 1. Control group showed a few irregular, rough, uneven surface with crater-like depression. 2. The test group with Tetracycline-HCl conditioning showed an altered surface when Tetracycline-HCl was applied for 30secs, and showed a various surface alteration as application times go on. 3. The test group with Saline conditioning showed no significant surface differences and surface roughness. 4. The significant increase of Ra value was showed when Tetracycline-HCl was applied for 30secs. In conclusion, the 50mg/ml Tetracycline-HCl must not be applied for the RBM surface implant for surface treatment.

Factors Affecting Survival of Maxillary Sinus Augmented Implants (상악동 거상술을 동반한 임플란트의 생존율에 관한 기여인자)

  • In, Yeon-Soo;Park, Young-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.3
    • /
    • pp.241-248
    • /
    • 2011
  • Purpose: The aim of this study was to present the clinical results of maxillary sinus augmentation implants and to evaluate the effects of various factors on the implant survival rate. Methods: In a total of 112 patients, 293 implants after sinus augmentation were performed. The total survival rate and the influence of the following factors on implant survival were evaluated; patient characteristics (sex, age, smoking, general disease), graft material, implant surface, implant installation stage, site of implant placement, length and width of implant, closure method for osseous window, residual alveolar bone height. Results: 1. Age ranged from 16 to 70 yr, with a mean of 45.7 yr. 2. Cumulative survival rate for the 293 implants with the maxillary sinus augmentation procedure was 94.9%. 3. Simultaneous implant installation was performed in 122 patients and delayed implant installation was performed in 117 implants. The average healing period after sinus elevation was 7.3 months for delayed implant installation and this procedure had a significantly higher survival rate. 4. There were no significant differences in sex, age, smoking, general disease, site of implant placement, length and width of implant, residual alveolar bone height and the survival rate. 5. RBM (Resorbable Blasting Media) implant surface and allograft groups had significantly lower survival rates. Conclusion: These data suggest that maxillary sinus augmentation may give more predictable results for autogenous bone grafts and delayed implant placement.

Comparative study on the osseointegration of implants in dog mandibles according to the implant surface treatment

  • Yoon, Wook-Jae;Kim, Su-Gwan;Oh, Ji-Su;You, Jae-Seek;Jeong, Kyung-In;Lim, Sung-Chul;Jeong, Mi-Ae
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.42 no.6
    • /
    • pp.345-351
    • /
    • 2016
  • Objectives: This study compared the impact of implant surface treatment on the stability and osseointegration of implants in dog mandibles. Materials and Methods: Six adult dogs received a total of 48 implants that were prepared using four different surface treatments; resorbable blast media (RBM), hydroxyapatite (HA), hydrothermal-treated HA, and sand blasting and acid etching (SLA). Implants were installed, and dogs were separated into 2- and 4-week groups. Implant stability was evaluated via Periotest M, Osstell Mentor, and removal torque analyzers. A histomorphometric analysis was also performed. Results: The stability evaluation showed that all groups generally had satisfactory values. The histomorphometric evaluation via a light microscope revealed that the HA surface implant group had the highest ratio of new bone formation on the entire fixture. The hydrothermal-treated HA surface implant group showed a high ratio of bone-to-implant contact in the upper half of the implant area. Conclusion: The hydrothermal-treated HA implant improved the bone-to-implant contact ratio on the upper fixture, which increased the implant stability.

Surface Characteristics of Dental Implant Fixture with Various Manufacturing Process (치과 임플란트 고정체의 여러 가지 제조공정과정에 따른 표면특성)

  • Jeong, Yong-Hoon;Moon, Young-Pil;Lee, Chung-Hwan;Yu, Jin-Woo;Choe, Han-Cheol
    • Journal of the Korean institute of surface engineering
    • /
    • v.43 no.1
    • /
    • pp.17-24
    • /
    • 2010
  • In this study, surface characteristics of dental implant fixture with various manufacturing process have been researched using electrochemical methods. The dental implant fixture was selected with 5 steps by cleaning, surface treatment and sterilization with same size and screw structure; the 1st step-machined surface, 2nd step-cleaned by thinner and prosol solution, 3th step-surface treated by RBM (resorbable blasting media) method, 4th step-cleaned and dried, 5th step-sterilized by gamma-ray. The electrochemical behavior of dental implant fixture has been evaluated by using potentiostat (EG&G Co, 2273A) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The corrosion surface was observed using field-emission scanning electron microscopy (FE-SEM) and energy dispersive x-ray spectroscopy (EDS). The step 5 sample showed the cleaner and rougher surface than step 3 sample. The step 5 sample of implant fixture treated by RBM and gamma sterilization showed the low corrosion current density compared to others. Especially, the step 3 sample of implant fixture treated by RBM was presented the lowest value of corrosion resistance and the highest value of corrosion current density. The step 3 sample showed the low value of polarization resistance compared to other samples. In conclusion, the implant fixture treated with RBM and gamma sterilization has the higher corrosion resistance, and corrosion resistance depends on the step of manufacturing process.

THE STUDY OF THE DENTAL PLAQUE FORMATION ON DIFFERENT IMPLANT SURFACES (임플란트 표면에 따른 인공치면세균막 형성에 관한 연구)

  • Kim, Jin-Woo;Han, Se-Jin;Kim, Kyung-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.3
    • /
    • pp.325-340
    • /
    • 2008
  • The purpose of this study was to evaluate the artificial dental plaque by Streptococcus mutans on 4 different implant surfaces. In this study, the specimens were divided into 4 groups according to implant surface treatment. Uncoated implant group(n=5) which has an uncoated, smooth surfaced implant(Osstem, Korea), SLA implant group(n=5) which has an sandblasted large grit and acid-etched surface implant(Bicon, USA). Oxidized implant group(n=5) which has an oxidized surfaced implant (Osstem, Korea), and RBM implant group(n=5) which has resorbable blasting media(RBM) surfaced implant(Osstem, Korea). Acquired pellicle by human saliva and dental plaque by Streptococcus mutans were made on each implant surface. To analyze the plaque condition on implants surfaces, cell count and optical density were taken as a microbiologic method, and SEM(Scanning Electronic Microscope) findings was also taken for evaluation of surface condition. The following results were obtained. 1. Cell counting results of artificial dental plaque were Uncoated group($658.0{\pm}102.0$), RBM group($878.0{\pm}170.0$), SLA group ($946.0{\pm}42.0$), Oxidized group($992.0{\pm}40.0$), and there was difference between Oxidized group and Uncoated implant group(p<0.05). In case of modified cell counting results by v/w% were RBM group($197.8{\pm}45.2$), Oxidized group($207.04{\pm}8.34$), Uncoated group($261.6{\pm}40.6$), SLA group($315.4{\pm}14.0$), and there was difference between RBM group and SLA group(p<0.05). 2. Optical density results of artificial dental plaque after ultrasonic treatment was that there was difference among groups, and optical density of RBM group was higher than that of Uncoated group(p<0.05). In case of modified optical density results by v/w%, there was difference among groups, and the modified optical density of Uncoated group and SLA group was higher than those of Oxidized group and RBM group(P>0.05). 3. SEM findings of artificial dental plaque on the surfaces of implant as follows; there were artificial dental plaque on the surfaces of all test implants. Streptococcus mutans and by-product were observed at 10,000 times magnified condition on all test implants. Adhesion area of artificial dental plaque was about 1/2 of total surface after 24 hours incubate at $37^{\circ}C$. These results showed that there were differences among implant surfaces on the growth of Streptococcus mutans, and bacteria and by-product were covered about 1/2 area of total implant surfaces at 24 hours incubate at $37^{\circ}C$.

THE EFFECT OF SURFACE TREATMENT OF THE CERVICAL AREA OF IMPLANT ON BONE REGENERATION IN MINI-PIG (미니돼지에서 발치 후 즉시 임플란트 매식시 치경부 표면처리가 골재생에 미치는 효과)

  • Cho, Jin-Yong;Kim, Young-Jun;Yu, Min-Gi;Kook, Min-Suk;Oh, Hee-Kyun;Park, Hong-Ju
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.3
    • /
    • pp.285-292
    • /
    • 2008
  • Purpose: The present study was performed to evaluate the effect of surface treatment of the cervical area of implant on bone regeneration in fresh extraction socket following implant installation. Materials and methods: The four minipigs, 18 months old and 30 kg weighted, were used. Four premolars of the left side of both the mandible and maxilla were extracted. ${\phi}$3.3 mm and 11.5 mm long US II plus implants (Osstem Implant co., Korea) with resorbable blasting media (RBM) treated surface and US II implants (Osstem Implant co., Korea) with machined surface at the top and RBM surface at lower portion were installed in the socket. Stability of the implant was measured with $Osstell^{TM}$ (Model 6 Resonance Frequency Analyser: Integration Diagnostics Ltd., Sweden). After 2 months of healing, the procedures and measurement of implant stability were repeated in the right side by same method of left side. At four months after first experiment, the animals were sacrificed after measurement of stability of all implants, and biopsies were obtained. Results: Well healed soft tissue and no mobility of the implants were observed in both groups. Histologically satisfactory osseointegration of implants was observed with RBM surface, and no foreign body reaction as well as inflammatory infiltration around implant were found. Furthermore, substantial bone formation and high degree of osseointegration were exhibited at the marginal defects around the cervical area of US II plus implants. However, healing of US II implants was characterized by the incomplete bone substitution and the presence of the connective tissue zone between the implant and newly formed bone. The distance between the implant platform (P) and the most coronal level of bone-to-implant contact (B) after 2 months of healing was $2.66{\pm}0.11$ mm at US II implants group and $1.80{\pm}0.13$mm at US II plus implant group. The P-B distance after 4 months of healing was $2.29{\pm}0.13$mm at US II implants group and $1.25{\pm}0.10$mm at US II plus implants group. The difference between both groups regarding the length of P-B distance was statistically significant(p<0.05). Concerning the resonance frequency analysis (RFA) value, the stability of US II plus implants group showed relatively higher RFA value than US II implants group. Conclusion: The current results suggest that implants with rough surface at the cervical area have an advantage in process of bone regeneration on defect around implant placed in a fresh extraction socket.

FOUR-YEAR SURVIVAL RATE OF RBM SURFACE INTERNAL CONNECTION NON-SUBMERGED IMPLANTS AND THE CHANGE OF THE PERI-IMPLANT CRESTAL BONE (RBM 표면처리 내부연결형 비매립 임플란트의 4년 생존율과 주변골 흡수에 관한 임상 및 방사선학적 연구)

  • Jeon, Hye-Ran;Kim, Myung-Rae;Lee, Dong-Hyun;Shin, Jung-Sub;Kang, Na-Ra
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.3
    • /
    • pp.237-242
    • /
    • 2009
  • Implant-supported fixed and removable prostheses provide a proper treatment modality with reliable success. The SS $II^{(R)}$ Implants is a one-stage nonsubmerged threaded titanium implants with Resorbable Blasting Media (RBM) surface developed by Osstem company (Busan, Korea) in October of 2002. This study is to evaluate the survival rate of the SS $II^{(R)}$ Implants for 4 years using radiographic parameters and to review the retrieved implants by the cytotoxicity tests. Since September 2003, 439 SS $II^{(R)}$ implants had been used for 173 patients at Ewha Womans University Medical Center in Korea. Patients consisted of 91 females (52.6 %) and 82 males (47.4 %). The patients' mean age was $42\;{\pm}16$ years, ranging from 21 to 83 years. The follow-up period ranged from 9 to 46 months (mean F/U $24.2\;{\pm}\;10.2$ months). The results are as follows; 1. Of 439 implants, 17 implants were removed and 4-year cumulative survival rate was 96.1%. 2. 82.3% of 17 failed implants were founded during healing phase, and 94.1% of failed fixtures were removed within 5 months after implantation. 3. Crestal bone around the implants was resorbed to 1 mm in 89.0%, to 1 - 2 mm loss of the marginal bone in 8.3%, and the bone loss over 2 mm was occurred in 2.7%. 4. Microscopic examination of the retrieved implants disclosed Grade 0 cytotoxicity in 4 and Grade 1 cytotoxicity in 2 of 6 groups divided according to LOT numbers. Inhibition rate with optical density was acceptable as low as ISO standard.