• Title/Summary/Keyword: Resonance Type

Search Result 1,085, Processing Time 0.027 seconds

Micro structural characteristics of Bragg reflector of SMR type FBAR device deposited by RF magnetron sputtering (RF 마그네트론 스퍼터링에 의해 증착된 SMR 구조 FBAR 소자의 Bragg 반사층의 미세구조 특성에 관한 연구)

  • Park, Sung-Hyun;Lee, Sun-Beom;Lee, Neung-Heon;Shin, Young-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.1992-1994
    • /
    • 2005
  • In this study, Bragg reflector was formed as tungsten(W) and $SiO_2$ deposited by RF magnetron sputtering according to variable conditions of RF power and working pressure to apply to the SMR type FBAR device, one of the next generation mobile communication devices. The micro-structural properties such as a crystal orientation, roughness and micro- structure were measured by XRD, AFM and SEM and the best condition of Bragg reflector was elicited with analyzing that results of the thin films about each conditions. Finally, FBAR device was fabricated with applying the Bragg reflector was formed on the best condition and measured the resonance properties and compared other research and considered it.

  • PDF

A Study on the Application for the Vibration Active Control by using a Voice call type LOA (보이스코일형 LOA의 진동능동제어 시스템에의 응용에 관한 연구)

  • Jang, S.M.;Jeong, S.S.;Seo, J.H.;Kim, H.G.;Park, H.C.;Moon, S.J.;Chung, J.A.;Park, C.I.;Chung, T.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.317-319
    • /
    • 1996
  • In this paper, an active vibration control system using a voice coil type linear oscillating actuator(LOA) is studied to suppress structural vibration. Being compared with a hydraulic actuator, a LOA has simplified structure and requires a few elements in the driving system, so it has lots of merits with respect to economics and maintenance. The general mathematical dynamic model to obtain the algorithm for the realization of vibration active control system is treated. Actually, the performance test of the control system using LOA is carried out on a steel test structure under sinusoidal and white noise excitation. From this test it is conformed that acceleration level of test structure is reduced near the resonance region. In the future research on the application to large structures will be studied.

  • PDF

Improved kinematic mount design for bar type reference mirror for profilometric measurement large optical surface

  • Jung, Kil-Jae;Yang, Ho-Soon;Rhee, Hyug-Gyo;Jyun, Byoung-Hyug;Lee, Yun-Woo;Kim, Sug-Whan
    • Bulletin of the Korean Space Science Society
    • /
    • 2010.04a
    • /
    • pp.25.3-25.3
    • /
    • 2010
  • Our previous study used a bar-type reference mirror to measure the relative distance to the target surface. The target measurement accuracy was required to $1{\mu}m$ PV for aspheric optical surface up to 1m in diameter. Earlier system suffers from the reference surface deformation when the measuring part moves. In order to reduce the deformation, measuring part and the reference part separated from each order in the new design. This system utilizes a kinematic support assembly using invar flexure to minimize the reference surface deformation under gravity and vibration. The surface deformation requirement of reference mirror is defined as of $0.2{\mu}m$ under gravity and 40Hz vibration. The finite element results, shows reference mirror deformation of $0.164{\mu}m$. The first resonance mode was computed to analysis 46.05Hz for reference part and 43.44Hz for measuring part. Thesis satisfies the frequency requirement.

  • PDF

Reduction of Aerodynamic Noise for a High-Speed Slim-Type Optical Disk Drive by Applying the Principle of Resonator (공명기를 이용한 고배속 슬림형 드라이브의 유동기인 소음저감에 관한 연구)

  • Yang, Tae-Man;Choi, Moon-Ho;Rhim, Yoon-Chul;Lee, In-Hwan;Lee, Han-Beak;Cha, Ik-Joo
    • Transactions of the Society of Information Storage Systems
    • /
    • v.3 no.4
    • /
    • pp.196-201
    • /
    • 2007
  • As the demand for the lap-top computer has been increased, most users ask quiet environment to work comfortably. Therefore, noise problems of an ODD are of great interest. For the high speed ODD, the flow induced noise is caused by the turbulent flow[1], which is known to be a major source of overall noise of a slim type ODD. In this study, we introduce a new attempt to reduce the noise level using the concept of Helmholtz resonator[2].The experimental analysis is carried out for several cases at different resonance frequencies and different hole patterns. The results show reductions in the noise level from the acoustic noise absorption point of view.

  • PDF

Second Harmonic Generation with a Type II Phase-Matched $KTiOPO_4$ and an External Ring Cavity (제2종 위상정합용 $KTiOPO_4$와 고리형 공동을 이용한 제2고조파 발진)

  • 김경범;박주현;노재우
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.4
    • /
    • pp.236-239
    • /
    • 1998
  • We constructed a frequency doubler with a frequency-stabilized Nd:YAG Laser, a nonlinear crystal KTP, and an external resonant cavity. Using type II phase-making method and a resonant cavity, one usually have a serious problem that the second harmonic conversion efficiency is decreased greatly, for under usual circumstances ordinary ray and extraorninary ray cannot be resonated in a cavity simultaneously. With the change of temperature and incident angle of KTP, we found an optimized condition for the phase-matching and double-resonance. As a result we produced 26 mW of green light with 318 mW of fundamental laser power from a cw Nd:YAG laser.

  • PDF

High Pressure Synthesis and Physical Properties of the Solid Solution, $SrLaAl_{1-x}Ni_xO_4(0

  • 변송호
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.11
    • /
    • pp.1084-1088
    • /
    • 1995
  • A complete solid solution (SrLaAl1-xNixO4) between insulating SrLaAlO4 and metallic SrLaNi(Ⅲ)O4 oxides were prepared under high oxygen pressure (1.5 kbar, 800 ℃). They have tetragonal K2NiF4-type structure in all the solid solution range. Compared with lattice parameters of the same solid solution prepared under normal condition (1 bar, 1200 ℃), large decrease in the c-parameter was induced by high pressure treatment while no noticeable variation of the a-parameter was observed. Although marked changes of structural parameters, magnetic susceptibilities, and electron paramagnetic resonance spectra were consistently occurred before and after x=0.5, overall behaviors were essentially the same with those of solid solution prepared under normal condition. Such a phenomenon is explained by assuming the formation of partially filled narrow σ*x2-y2 band for x>0.5. Lattice contraction along the c-axis by high pressure treatment seems not to broaden this band. Particularly, the continuous absorption characteristic of a high free carrier concentration for x>0.5 and the absence of Ni-O in-plane stretching mode in the infrared absorption spectra supports this picture. However, the conductivities increasing with temperature for all solid solution suggest that some localization character, of probably Anderson type, remains for x>0.5.

Reactivity Evaluation on Copper Etching Using Organic Chelators (유기 킬레이터들을 이용한 구리 식각에 대한 반응성 평가)

  • Kim, Chul Hee;Lim, Eun Taek;Park, Chan Ho;Park, Sung Yong;Lee, Ji Soo;Chung, Chee Won;Kim, Dong Wook
    • Korean Journal of Materials Research
    • /
    • v.31 no.10
    • /
    • pp.569-575
    • /
    • 2021
  • The reactivity evaluation of copper is performed using ethylenediamine, aminoethanol, and piperidine to apply organic chelators to copper etching. It is revealed that piperidine, which is a ring-type chelator, has the lowest reactivity on copper and copper oxide and ethylenediamine, which is a chain-type chelator, has the highest reactivity via inductively coupled plasma-mass spectroscopy (ICP-MS). Furthermore, it is confirmed that the stable complex of copper-ethylenediamine can be formed during the reaction between copper and ethylenediamine using nuclear magnetic resonance (NMR) and radio-thin layer chromatography. As a final evaluation, the copper reactivity is evaluated by wet etching using each solution. Scanning electron micrographs reveal that the degree of copper reaction in ethylenediamine is stronger than that in any other chelator. This result is in good agreement with the evaluation results obtained by ICP-MS and NMR. It is concluded that ethylenediamine is a prospective etch gas for the dry etching of the copper.

Presurgical assessment of splenic tumors in dogs: a retrospective study of 57 cases (2012-2017)

  • Lee, Mokhyeon;Park, Jiyoung;Choi, Hojung;Lee, Haebeom;Jeong, Seong Mok
    • Journal of Veterinary Science
    • /
    • v.19 no.6
    • /
    • pp.827-834
    • /
    • 2018
  • The purpose of this study was to evaluate the clinical and imaging characteristics of canine splenic tumors and to establish guidelines for the presurgical assessment of splenic tumors in dogs. Fifty-seven dogs that underwent total splenectomy for the treatment of splenic tumors were evaluated by examining medical records, hematologic results, diagnostic imaging results, and histopathologic results. The maximum lesion size from ultrasonography was significantly different between malignant and benign tumors (p = 0.002). There was a correlation between tumor margination and type of splenic tumors (p = 0.045). Precontrast lesion attenuation on computed tomography was significantly different between splenic malignant and benign tumors (p = 0.001). The mean ${\pm}$ SD precontrast lesion attenuation of malignant tumors was $40.3{\pm}5.9$ Hounsfield units (HU), and for benign tumors, it was $52.8{\pm}6.8HU$. In conclusion, some variables of the imaging examination could be used to distinguish the type of splenic tumor. Based on the study results, using a diagnostic flowchart would be effective in increasing the survival rate of patients with splenic malignant tumors. In addition, fine needle aspiration or magnetic resonance imaging prior to surgical exploration and histopathologic examination may be useful in achieving a more accurate diagnosis.

Bilateral Occipital Neuralgia in a Patient with Neurofibromatosis Type 1: A Case Report (신경 섬유종증 1형 환자의 양측 후두 신경통: 증례보고)

  • Kim, Ji-Young;Jeon, Sungmi;Kim, Sang Wha
    • Korean Journal of Head & Neck Oncology
    • /
    • v.37 no.2
    • /
    • pp.77-80
    • /
    • 2021
  • Plexiform neurofibromas (PNFs) represent an uncommon variant (30%) of neurofibromatosis type 1 (NF-1), in which neurofibromas arise from multiple nerves as bulging and deforming masses involving connective tissue and skin folds. We report the case of a 17-year-old man with known NF-1 presenting with bilateral occipital neuralgia that began in his late adolescence. His chief complaint was radiating pain in the occiput induced by protective helmet wear when riding alpine skiing. Craniofacial magnetic resonance imaging (MRI) confirmed the presence of fusiform masses arising from the bilateral greater occipital nerves. Histopathological examination of the biopsy samples showed PNFs. After surgical treatment, the patient's symptoms completely improved. Unlike cutaneous neurofibromas, PNFs have different clinical characteristics and have the risk of malignant mutations. Correct diagnosis and adequate surgical treatment are necessary for PNFs.

Optimal Design of Ultrasonic Horn for Ultrasonic Drilling Processing of Ceramic Material (세라믹 소재 초음파 드릴링 가공을 위한 초음파 Horn의 최적 설계에 관한 연구)

  • Cha, Seung-hwan;Yang, Dong-ho;Lee, Sang-hyeop;Lee, Jong-Chan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.9
    • /
    • pp.1-11
    • /
    • 2022
  • Recently, there has been continuous technological development in the semiconductor industry, and semiconductor manufacturing technologies are being advanced and highly integrated. For this reason, ceramic material having excellent heat resistance, wear resistance, and conductivity are used as components in semiconductor manufacturing. Among them, the probe card's space transformer is used as ceramic material to prevent electronic signal noise during the electrical die sorting of semiconductor function testing. However, implementing a bulk-type space transformer with a thickness of 5.6 mm or more is challenging, and thus it is produced in a structure with a stacked ceramic film. The stacked space transformer has low productivity because it is difficult to ensure hole clogging and a precise shape. In this research, an ultrasonic horn is designed to manufacture a bulk-type ceramic space transformer through ultrasonic drilling. Vibration characteristics were analyzed according to the ultrasonic horn, and the natural frequency was measured.