• Title/Summary/Keyword: Resolution Conversion

Search Result 282, Processing Time 0.035 seconds

The Development on Medical Malpractice Lawsuit and its Burden of Proof (의료과오소송 입증책임론의 전개와 발전)

  • Shin, Eun-Joo
    • The Korean Society of Law and Medicine
    • /
    • v.9 no.1
    • /
    • pp.9-56
    • /
    • 2008
  • The medical practice does not always get a satisfatory result since the disease progress of patients are depended on patients' physical constitution and the doctors cannot control the outcomes about patients' physiological and biological reaction after the treatment. Moreover, the medical practice may bring wrong result fatalistically because of the unpredictablility of life. To demand for compensation of the damage to the doctors about these wrong result, the patient side holds the burden of proof that is between medical practice and demage, and there is damage from doctor's malpractice according to the accepted theory about the fundamental principle of distribution of the burden of proof. This falls not only under the liability of Tort Law, but also liability of Contract Law. However, the patient may be in difficult situation to prove the malpractice of doctors since he or she cannot recognize the facts because he or she was in unconscious while the medical practice was conducted, or they cannot judge precisely even though they recognize the facts. Nevertheless, the lawsuits against medical malpractice are the field that never achieves the equality of arms since the most of the evidence belong to the doctor's side. Hence, to maintain the principle of the equality of arms under the constitution, the theory leads to alleviate the burden of proof that patients hold. However, the doctors cannot be asked for the burden of proof that they conduct medical practice without errors. Because the doctors may experience difficulty to prove their innocence as the patients because of the unique characteristic that medical practices have. Therefore, the methods of the alleviation of the patient's burden of proof should have the equality of arms and the equal opportunity between the patients and the doctors with the evaluation of the justifiable interest from both the patients and the doctors. As the methods of the alleviation of the burden of proof, the alleviation of the demands and the degree of the burden of proof or resolutely the conversion of the burden may be considered. However, Recognizing the exception from general principle with converting the burden of proof is not proper in principle because the doctors may experience difficulty of the proof as the patients may have. If the difficulty of proof can be resolved by alleviating of the demands and the degree of the burden of proof, it is more desirable resolution rather than converting the burden of proof.

  • PDF

An 1.2V 10b 500MS/s Single-Channel Folding CMOS ADC (1.2V 10b 500MS/s 단일채널 폴딩 CMOS A/D 변환기)

  • Moon, Jun-Ho;Park, Sung-Hyun;Song, Min-Kyu
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.1
    • /
    • pp.14-21
    • /
    • 2011
  • A 10b 500MS/s $0.13{\mu}m$ CMOS ADC is proposed for 4G wireless communication systems such as a LTE-Advanced and SDR The ADC employs a calibration-free single-channel folding architecture for low power consumption and high speed conversion rate. In order to overcome the disadvantage of high folding rate, at the fine 7b ADC, a cascaded folding-interpolating technique is proposed. Further, a folding amplifier with the folded cascode output stage is also discussed in the block of folding bus, to improve the bandwidth limitation and voltage gain by parasitic capacitances. The chip has been fabricated with $0.13{\mu}m$ 1P6M CMOS technology, the effective chip area is $1.5mm^2$. The measured results of INL and DNL are within 2.95LSB and l.24LSB at 10b resolution, respectively. The SNDR is 54.8dB and SFDR is 63.4dBc when the input frequency is 9.27MHz at sampling frequency of 500MHz. The ADC consumes 150mW($300{\mu}W/MS/s$) including peripheral circuits at 500MS/s and 1.2V(1.5V) power supply.

Spatial Interpolation of Hourly Air Temperature over Sloping Surfaces Based on a Solar Irradiance Correction (일사 수광량 보정에 의한 산악지대 매시기온의 공간내삽)

  • 정유란;윤진일
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.4 no.2
    • /
    • pp.95-102
    • /
    • 2002
  • Spatial interpolation has become a common procedure in converting temperature forecasts and observations at irregular points for use in regional scale ecosystem modeling and the model based decision support systems for resource management. Neglection of terrain effects in most spatial interpolations for short term temperatures may cause erroneous results in mountainous regions, where the observation network hardly covers full features of the complicated terrain. A spatial interpolation model for daytime hourly temperature was formulated based on error analysis of unsampled site with respect to the site topography. The model has a solar irradiance correction scheme in addition to the common backbone of the lapse rate - corrected inverse distance weighting. The solar irradiance scheme calculates the direct, diffuse and reflected components of shortwave radiation over any surfaces based on the sun-slope geometry and compares the sum with that over a reference surface. The deviation from the reference radiation is used to calculate the temperature correction term by an empirical conversion formula between the solar energy and the air temperature on any sloped surfaces at an hourly time scale, which can be prepared seasonally for each land cover type. When this model was applied to a 14 km by 22 km mountainous region at a 10 m horizontal resolution, the estimated hourly temperature surfaces showed a better agreement with the observed distribution than those by a conventional method.

Analysis of Land Use Change Using RCP-Based Dyna-CLUE Model in the Hwangguji River Watershed (RCP 시나리오 기반 Dyna-CLUE 모형을 이용한 황구지천 유역의 토지이용변화 분석)

  • Kim, Jihye;Park, Jihoon;Song, Inhong;Song, Jung-Hun;Jun, Sang Min;Kang, Moon Seong
    • Journal of Korean Society of Rural Planning
    • /
    • v.21 no.2
    • /
    • pp.33-49
    • /
    • 2015
  • The objective of this study was to predict land use change based on the land use change scenarios for the Hwangguji river watershed, South Korea. The land use change scenario was derived from the representative concentration pathways (RCP) 4.5 and 8.5 scenarios. The CLUE (conversion of land use and its effects) model was used to simulate the land use change. The CLUE is the modeling framework to simulate land use change considering empirically quantified relations between land use types and socioeconomic and biophysical driving factors through dynamical modeling. The Hwangguji river watershed, South Korea was selected as study area. Future land use changes in 2040, 2070, and 2100 were analyzed relative to baseline (2010) under the RCP4.5 and 8.5 scenarios. Binary logistic regressions were carried out to identify the relation between land uses and its driving factors. CN (Curve number) and impervious area based on the RCP4.5 and 8.5 scenarios were calculated and analyzed using the results of future land use changes. The land use change simulation of the RCP4.5 scenario resulted that the area of urban was forecast to increase by 12% and the area of forest was estimated to decrease by 16% between 2010 and 2100. The land use change simulation of the RCP8.5 scenario resulted that the area of urban was forecast to increase by 16% and the area of forest was estimated to decrease by 18% between 2010 and 2100. The values of Kappa and multiple resolution procedure were calculated as 0.61 and 74.03%. CN (III) and impervious area were increased by 0-1 and 0-8% from 2010 to 2100, respectively. The study findings may provide a useful tool for estimating the future land use change, which is an important factor for the future extreme flood.

A CMOS Image Sensor with Analog Gamma Correction using a Nonlinear Single Slope ADC (비선형 단일 기울기 ADC를 사용하여 아날로그 감마 보정을 적용한 CMOS 이미지 센서)

  • Ham Seog-Heon;Han Gunhee
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.1 s.343
    • /
    • pp.65-70
    • /
    • 2006
  • An image sensor has limited dynamic range while the human eye has logarithmic response over wide range of light intensity. Although the sensor gain can be set high to identify details in darker area on the image, this results in saturation in brighter area. The gamma correction is essential to fit the human eye response. However, the digital gamma correction degrades image quality especially for darker area on the image due to the limited ADC resolution and the dynamic range. This Paper proposes a CMOS image sensor (CIS) with a nonlinear analog-to-digital converter (AU) which performs analog gamma correction. The CIS with the proposed nonlinear analog-to-digital conversion scheme was fabricated with a $0.35{\mu}m$ CMOS process. The analog gamma correction using the proposed nonlinear ADC CIS provides the 2.2dB peak-signal-to-noise-ratio(PSM) improved image qualify than conventional digital gamma correction. The PSNR of the image obtain from the digital gamma correction is 25.6dB while it is 27.8dB for analog gamma correction. The PSNR improvement over digital gamma correction is about $28.8\%$.

THE EFFECT OF EXOGENOUS ELECTRIC CURRENTS ON CYCLIC NUCLEOTIDES IN FELINE ALVEOLAR BONE (외인성전류가 고양이 치조골의 cyclic nucleotides에 미치는 영향에 관한 연구)

  • Kim, Young-Bok;Lee, Jong-Heun;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.14 no.2
    • /
    • pp.187-202
    • /
    • 1984
  • There are evidences that exogenous electric currents are capable of enhancing bone formation and resolution, and that the conversion of the bioelectric response to biochemical activity provides the directional component of orthodontic tooth movement. In addition, evidence has implicated cyclic nucleotides in alveolar bone cellular activation mechanism during orthodontic tooth movement. In view of these evidences, this study was performed to investigate the effects of exogenous electric currents on cyclic nuclotide levels in feline alveolar bone and the possible clinical application of electric currents as an additional orthodontic tool. In the first study, three groups of three adult cats were subjected to application of a constant direct current of $10{\pm}2$ microamperes to gingival tissue near maxillary canine noninvasively for 1, 3, and 7 days respectively. In the second study, three groups of three adult cats each were treated by an electric-orthodontic procedure for 1, 3, and 7 days respectively. The left maxillary (control) canine received an orthodontic force of 80gm alone at time of initiation, while the right maxillary (experimental) canine received combined force-electric stimulation (80gm of force and $10{\pm}2$ microamperes of a constant D.C. currents). Alveola, bone samples were obtain from the mesial (tension and/or cathode) and the distal (compression and/or anode) sites surrounding maxillary canines as well as from contralateral control sites. The samples were extracted, boiled, homogenized, and the supernatants were assayed for cyclic nucleotides (cAMP, cGMP) by a radioimmunoassay method. And also the amount of tooth movement was measured in the second study. On the basis of this study, the following conclusions can be drawn: 1. The fluctuation pattern of cyclic nucleotide levels in alveolar bone treated by exogenous electric currents was similar to that treated by orthodontic force. 2. The cAMP levels in alveolar bone of electrically treated teeth significantly elevated above the control values. And of electrically treated teeth, the values of the anode sites were higher than those of the cathode sites. 9. The cGMP levels in alveolar bone of electrically treated teeth elevated above the control values at the initiation phase of treatment, but dropped below the control values at time of termination. And of electrically treated teeth, the values of the cathode sites were higher than those of the anode sites. 4. The rate of tooth movement in teeth . treated by force-electric combination increased with the length of treatment as compared to that treated by mechanical force alone.

  • PDF

A Signal Readout System for CNT Sensor Arrays (CNT 센서 어레이를 위한 신호 검출 시스템)

  • Shin, Young-San;Wee, Jae-Kyung;Song, In-Chae
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.9
    • /
    • pp.31-39
    • /
    • 2011
  • In this paper, we propose a signal readout system with small area and low power consumption for CNT sensor arrays. The proposed system consists of signal readout circuitry, a digital controller, and UART I/O. The key components of the signal readout circuitry are 64 transimpedance amplifiers (TIA) and SAR-ADC with 11-bit resolution. The TIA adopts an active input current mirror (AICM) for voltage biasing and current amplification of a sensor. The proposed architecture can reduce area and power without sampling rate degradation because the 64 TIAs share a variable gain amplifier (VGA) which needs large area and high power due to resistive feedback. In addition, the SAR-ADC is designed for low power with modified algorithm where the operation of the lower bits can be skipped according to an input voltage level. The operation of ADC is controlled by a digital controller based on UART protocol. The data of ADC can be monitored on a computer terminal. The signal readout circuitry was designed with 0.13${\mu}m$ CMOS technology. It occupies the area of 0.173 $mm^2$ and consumes 77.06${\mu}W$ at the conversion rate of 640 samples/s. According to measurement, the linearity error is under 5.3% in the input sensing current range of 10nA - 10${\mu}A$. The UART I/O and the digital controller were designed with 0.18${\mu}m$ CMOS technology and their area is 0.251 $mm^2$.

A UHF-band Passive Temperature Sensor Tag Chip Fabricated in $0.18-{\mu}m$ CMOS Process ($0.18-{\mu}m$ CMOS 공정으로 제작된 UHF 대역 수동형 온도 센서 태그 칩)

  • Pham, Duy-Dong;Hwang, Sang-Kyun;Chung, Jin-Yong;Lee, Jong-Wook
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.10
    • /
    • pp.45-52
    • /
    • 2008
  • We investigated the design of an RF-powered, wireless temperature sensor tag chip using $0.18-{\mu}m$ CMOS technology. The transponder generates its own power supply from small incident RF signal using Schottky diodes in voltage multiplier. Ambient temperature is measured using a new low-power temperature-to-voltage converter, and an 8-bit single-slope ADC converts the measured voltage to digital data. ASK demodulator and digital control are combined to identify unique transponder (ID) sent by base station for multi-transponder applications. The measurement of the temperature sensor tag chip showed a resolution of $0.64^{\circ}C/LSB$ in the range from $20^{\circ}C$ to $100^{\circ}C$, which is suitable for environmental temperature monitoring. The chip size is $1.1{\times}0.34mm^2$, and operates at clock frequency of 100 kHz while consuming $64{\mu}W$ power. The temperature sensor required a -11 dBm RF input power, supported a conversion rate of 12.5 k-samples/sec, and a maximum error of $0.5^{\circ}C$.

A 15b 50MS/s CMOS Pipeline A/D Converter Based on Digital Code-Error Calibration (디지털 코드 오차 보정 기법을 사용한 15비트 50MS/s CMOS 파이프라인 A/D 변환기)

  • Yoo, Pil-Seon;Lee, Kyung-Hoon;Yoon, Kun-Yong;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.5
    • /
    • pp.1-11
    • /
    • 2008
  • This work proposes a 15b 50MS/s CMOS pipeline ADC based on digital code-error calibration. The proposed ADC adopts a four-stage pipeline architecture to minimize power consumption and die area and employs a digital calibration technique in the front-end stage MDAC without any modification of critical analog circuits. The front-end MDAC code errors due to device mismatch are measured by un-calibrated back-end three stages and stored in memory. During normal conversion, the stored code errors are recalled for code-error calibration in the digital domain. The signal insensitive 3-D fully symmetric layout technique in three MDACs is employed to achieve a high matching accuracy and to measure the mismatch error of the front-end stage more exactly. The prototype ADC in a 0.18um CMOS process demonstrates a measured DNL and INL within 0.78LSB and 3.28LSB. The ADC, with an active die area of $4.2mm^2$, shows a maximum SNDR and SFDR of 67.2dB and 79.5dB, respectively, and a power consumption of 225mW at 2.5V and 50MS/s.

Application of GIS to the Universal Soil Loss Equation for Quantifying Rainfall Erosion in Forest Watersheds (산림유역의 토양유실량(土壤流失量) 예측을 위한 지리정보(地理情報)시스템의 범용토양유실식(汎用土壤流失式)(USLE)에의 적용)

  • Lee, Kyu Sung
    • Journal of Korean Society of Forest Science
    • /
    • v.83 no.3
    • /
    • pp.322-330
    • /
    • 1994
  • The Universal Soil Loss Equation (USLE) has been widely used to predict long-term soil loss by incorporating several erosion factors, such as rainfall, soil, topography, and vegetation. This study is aimed to introduce the LISLE within geographic information system(GIS) environment. The Kwangneung Experimental Forest located in Kyongki Province was selected for the study area. Initially, twelve years of hourly rainfall records that were collected from 1982 to 1993 were processed to obtain the rainfall factor(R) value for the LISLE calculation. Soil survey map and topographic map of the study area were digitized and subsequent input values(K, L, S factors) were derived. The cover type and management factor (C) values were obtained from the classification of Landsat Thematic Mapper(CM) satellite imagery. All these input values were geographically registered over a common map coordinate with $25{\times}25m^2$ ground resolution. The USLE was calculated for every grid location by selecting necessary input values from the digital base maps. Once the LISLE was calculated, the resultant soil loss values(A) were represented by both numerical values and map format. Using GIS to run the LISLE, it is possible to pent out the exact locations where soil loss potential is high. In addition, this approach can be a very effective tool to monitor possible soil loss hazard under the situations of forest changes, such as conversion of forest lands to other uses, forest road construction, timber harvesting, and forest damages caused by fire, insect, and diseases.

  • PDF