• Title/Summary/Keyword: Resistive current

Search Result 449, Processing Time 0.024 seconds

A Study on the Application Analysis of the Resistive type Superconducting Fault Current Limiters using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 저항형 초전도한류기의 계통적용분석 연구)

  • Heo Tae Jeon;Bang Jong Hyun;Bae Hyeong Thaek;Park Min Won;Yu In Keun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.1
    • /
    • pp.25-31
    • /
    • 2005
  • Since the discovery of the high temperature superconductors many researches have been performed for the practical applications of superconductivity technologies in various fields. As results, significant progress has been achieved. Especially, Superconducting Fault Current Limiter (SFCL) offers an attractive means In limit fault current in power systems. HTS resistive type SFCL is based on the ultra fast transition from the superconducting (non resistive) state to the normal (resistive) state by overstepping the critical current density, In this study, the simulation method of resistive type superconducting fault current limiter using EMTDC is proposed and the developed EMTDC model of SFCL is applied to the modeled power network using the Parameters of real system.

A Development of the High Precise Measuring Device and Methods of Resistive Leakage Current for the Deterioration Diagnosis of ZnO Arrester (산화아연 피뢰기의 열화진단을 위한 저항성누설전류의 고정도 측정기법 및 장치의 개발)

  • Lee, B.H.;Kang, S.M.;Jeon, D.K.;Park, K.Y.;Choi, H.S.;Cho, S.C.;Baek, Y.H.;Lee, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1668-1670
    • /
    • 2003
  • This paper deals with a development of the high precise measuring device of resistive leakage current for the deterioration and diagnosis of ZnO arresters. The resistive leakage current increasing with time leads to a thermally unstable state that may even experience a disaster. So, the resistive leakage current can be used as an indicator to discriminate whether the ZnO arrester blocks is in good state or in bad. The resistive leakage current measuring system with an analysis program operated with micro-processor using the time delay addition method was designed and fabricated. The proposed measuring systems for the resistive leakage current can effectively be used to develop the techniques of forecasting the deterioration of ZnO arresters in electric power systems.⨀ᔌ?؀㔳㤮㈻Ԁ䭃䑎䷗ᜒं6〰Ԁ䭃䑎䴀

  • PDF

The Effectiveness Analysis of the Resistive Leakage Current Monitoring by Analyzing the Phase of the Body Current (인체 통전전류 위상 분석을 통한 저항성 누설전류 감시의 유효성 분석)

  • Kim, Jae-Hyun;Lim, Young-Bea;Lee, Sang-Ick;Kim, Dong-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.90-99
    • /
    • 2013
  • To analyze the effectiveness of the resistive leakage current monitoring as a technology preventing electrical accidents, in this paper, we have estimated the phase of the body impedance by using the body impedance model and the body impedance data from IEC. We also have analyzed the phase of the electric body current in the case of 60Hz/220V. From these results, we concluded that deliberate researches about the phase of the electrical body current and related regulations must be carried out before the resistive leakage current monitoring unit is used to protect electric shock. And we concluded that the resistive leakage current monitoring unit can be utilized to prevent electrical fires caused by electric leakage current without unwanted circuit break due to capacitive leakage current flowing from line filter capacitors to the earth.

Operating Properties of Resistive Superconducting fault Current Limiters with Various Pattern Shapes

  • Park, Hyo-Sang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12S
    • /
    • pp.1286-1291
    • /
    • 2003
  • Quench behavior of resistive superconducting fault current limiters (SFCLS) with various pattern shapes was investigated. The pattern shapes employed were meander, bi-spiral, and spital shapes of identical line width, gap and margin. SFCLS were fabricated from YBCO thin films grown on two-inch diameter Al$_2$O$_3$ substrates under the same conditions. The total length of current limiting paths was the shortest at the spital shape due to its larger useless space. Inductance component of SFCLs with the spiral shape was around two times as high as those of other two shapes. This is not desirable since impedance characteristics of existing power systems can be changed. Resistance rise of current limiting elements was low at a spiral shape before the whole quench completion, which may act as a disadvantage for simultaneous quench in serial connection between current limiting elements, but the temperature tended to have similar values at higher voltages. On the other hand, hi-spital shape was severe at insulation level between current limiting lines. When these aspects were considered, we concluded that a meander shape was appropriate to design for a resistive SFCL based on thin films except the concentration of electric field at edge areas of strip lines.

New Algorithm for Measuring Resistive Leakage Current and Development of ELB Controller (새로운 저항성 누전전류 검출회로 및 누전차단제어기 개발)

  • Ham, Seung-Jin;Han, Song-Yop;Koh, Chang-Seop
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.132-134
    • /
    • 2007
  • The conventional method used low pass filter for computing resistive leakage current from total leakage current. Therefore, it takes long time for computation. In this paper, a new algorithm is proposed to reduce the computation time. In the theory, the resistive leakage current is computed exactly from the signals during only a half period of power voltage. The suggested method uses integrator and sample-hold circuit and it is confirmed to be able to measure the resistive leakage current from total leakage current by simulation.

  • PDF

Simulation for current limiting characteristics of the resistive and inductive SFCL with line-to-ground fault

  • Choi, Hyo-Sang;Hwang, Si-Dole;Kim, Sang-Joon;Han, Byoung-Sung
    • Progress in Superconductivity
    • /
    • v.1 no.1
    • /
    • pp.73-80
    • /
    • 1999
  • We investigated the current limiting characteristics of resistive and inductive SFCLs with 100 $\Omega$ of impedance for line-to-ground faults in the 154 kV transmission system. The fault simulation at the phase angles $0^{\circ}$, $^45{\circ}$, and $90^{\circ}$ showed that the resistive SFCL limits the fault current less than 17 kA without any DC component after one half cycle from the instant of the fault. On the other hand, the inductive SFCL suppresses the current below 14 kA, but with 5 kA of DC component which decreases to zero in 5 cycles. We concluded that the inductive SFCL has higher performance in current limiting effect, but the resistive SFCL was better from the viewpoint of less DC components.

  • PDF

EMTDC simulation for current limiting characteristics of the resistive and inductive SFCL (저항형과 유도형 한류기의 전류제한특성에 대한 EMTDC 해석)

  • 최효상;황시돌;현옥배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.255-258
    • /
    • 1999
  • We investigated the current limiting characteristics of resistive and inductive SFCLs with 100 $\Omega$ of quench impedance for a single line-to-ground fault. which accounts for about 70% of the total power line faults, in the 154 kV transmission system. The fault simulation at the phase angles 0$^{\circ}$, 45$^{\circ}$, and 90$^{\circ}$ showed that the resistive SFCL limited the fault current less than 15 kA without any DC component after one half cycle from the instant of the fault. On the other hand, the inductive SFCL suppressed the current below 12 KA, but with 3 kA of DC component which decreased to zero in 5 cycles. We concluded that the inductive SFCL had higher performance in current limiting but the resistive SFCL was better from the view point of DC components.

  • PDF

Simultaneous Quench Characteristic of Resistive Superconducting Fault Current Limiting Modules by using BSCCO Tape

  • Yang Seong-Eun;Ahn Min-Cheol;Park Dong-Keun;Youn Il-Goo;Jang Dae-Hee;Ko Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.2
    • /
    • pp.43-45
    • /
    • 2006
  • Recently, the resistive Fault Current Limiter (SFCL) made with Coated Conductor (CC) has been researched with an advanced capability in CC. Current limiting elements must be connected in series in order to fabricate the resistive SFCL having large capacity. By the way, unless the applied voltage in the SFCL is distributed to the elements when the fault occurred, those elements will be critically damaged. Thus simultaneous quench of the elements is an important factor to design the resistive SFCL. In this paper, simultaneous quench characteristics of current limiting module by using BSCCO 2223 were researched before manufacturing the resistive SFCL by using CC. At the first fault stage, the elements generated the resistance at the same time. However, the unequal voltage is applied to the each element in process of time. The method is suggested to solve the problem of the unequal distribution. These experimental results will play an important part in developing for the resistive SFCL by using CC.

The Development of Resistive Leakage Current Circuit Breaker using a ARM Processor (ARM 프로세서를 이용한 저항성 누전 차단기 개발)

  • Lee, Hyun-Do
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.4
    • /
    • pp.615-620
    • /
    • 2017
  • In this study, we have developed the resistive leakage current detecting and tripping circuit breaker based on a 32bit ARM processor. The developed leakage circuit breaker can be operated in a desired trip threshold within 0.03 seconds as specified in KS C 4613. This resistive leakage current breaker is expected to be applicable as a circuit breake for prevention of electric fires and electric shock in smart distribution panel.

Influence of System Voltage Harmonics on Arrester Deterioration Diagnostic Techniques by Leakage Current Measurement (누설전류측정에 의한 피뢰기 열화진단기술에 있어 전원고조파의 영향)

  • Kil, Gyung-Suk;Han, Joo-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.142-145
    • /
    • 2002
  • This paper describes an influence of system voltage harmonics on arrester deterioration diagnostic techniques based on leakage current measurement because the resistive current is composed of two components caused by nonlinear characteristics of arrester and by system voltage harmonics. Resistive leakage currents of arresters, which can be evaluated by the third harmonic component of total leakage currents, increase with its deterioration progress. In this paper, we developed a PSpice model for ZnO arrester to simulate the harmonics' effect described above. In simulation, pure sinusoidal voltage and the $3^{rd}$ harmonic voltage are applied to the model, and the leakage current changes are compared. The simulation results showed that the magnitudes of resistive leakage current depend not only on the phase of system voltage harmonics but also on the magnitude of it.

  • PDF