• 제목/요약/키워드: Resistance test

검색결과 6,803건 처리시간 0.032초

Resistance Reduction of a High Speed Small Boat by Air Lubrication

  • Jang Jin-Ho;Kim Hyo-Chul
    • Journal of Ship and Ocean Technology
    • /
    • 제10권1호
    • /
    • pp.1-9
    • /
    • 2006
  • The resistance reduction by an air lubrication effect of a large air cavity covering the hull bottom surface and the similarity relations involved have been investigated with a series of towing tank tests of three geometrically similar models. The test results of geometrically similar models have indicated that a large air cavity was formed beneath the bottom having a backward-facing step by artificially supplying air is effective for resistance reduction. The areas of air cavity and the required flow rates of air are directly related to the effective wetted surface area. The traditional extrapolation methods seem to be applicable to the estimation of the resistance in the tested range if corrections are made to account the changes in the frictional resistance caused by the changes in the effective wetted surface area. To investigate the effectiveness of air lubrication in improving the resistance performance of a practical ship, a small test boat having a backward-facing step under its bottom has been manufactured and speed trials in a river have been performed. Air has been supplied artificially into the downstream region of the bottom step to form a large air cavity covering the bottom surface. The results have confirmed the practical applicability of air lubrication for the resistance reduction of a small high-speed boat.

장기성능 평가를 위한 토목섬유 화학저항성 시험 고찰 (Consideration of Geosynthetics Chemical Resistance Test for Long-Term Performance Evaluation)

  • 전한용;장연수
    • 한국지반공학회논문집
    • /
    • 제25권7호
    • /
    • pp.55-64
    • /
    • 2009
  • 본 연구에서는 실제 현장조건을 고려하여 토목섬유의 화학저항성을 측정하기 위한 개선된 시험방법이 제안되었다. 이를 위하여 시공조건에 가장 근접한 시험법을 규격화하기 위한 인덱스 및 성능시험이 실시되었으며, Arrhenius 식에 의한 가속모델을 적용하여 실험 데이터를 해석하였다. 전반적인 실험 결과를 분석, 비교하여 현장 시공조건에 부합한 개선된 토목섬유의 화학저항성 시험방법을 확립하고 그 가능성을 제시하였다.

분말형 폴리머를 사용한 시멘트 경화체의 내구성 평가 (Evaluation of Durability Properties of Cement Matrix Using the Polymer of Powder Type)

  • 김성수;정호섭;이정배;윤하영;고준호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.495-498
    • /
    • 2005
  • It was investigated the durability of the concrete to improve construction materials with polymer cement mortar in this study. With the popularity of repair and rehabilitation material, some mixtures composed of Ethylene Vinyl Acetate(EVA) was studied. Ethylene Vinyl Acetate(EVA) carried out tests to determine its properties which a include: freezing-thawing resistance test, carbonation test, and chemical resistance test. Result of freezing-thawing resistance test, mass change ratio and chemical resistance test, mass change ratio decreased of 12 and $15\~45\%$ as compared with control mortar. Carbonation depth decreased $3.7\~5.6mm$ as polymer-cement ratio increased $1\~4\%$.

  • PDF

초기동해를 받은 콘크리트의 내동해성 평가법에 대한 검토 (Investigation on the Method of Evaluating the Resistance to Freezing and Thawing of Concrete Subjected Initial Frost Damage)

  • 고경택;장일영
    • 콘크리트학회논문집
    • /
    • 제11권4호
    • /
    • pp.117-127
    • /
    • 1999
  • In concrete incorporating high volume ground granulated blast-furnace slag that has frozen at early age, to evaluated the results of resistance to freezing and thawing is very difficult because the hydration of the concrete increases over the duration of rapid freezing and thawing test. Hence, the dynamic modulus of elasticity of specimens after freezing and thawing will be favorable results unless the hydration effect is taken into consideration. In this study, a method of evaluating to the resistance to freezing and thawing of concrete subjected freezing at early age, in which the effect of hydration is modified for its increase during rapid freezing and thawing test, is investigated.

하우징 형태(Housing Type)로 제작된 배선 연결 커넥터의 안전성 평가에 관한 연구 (A Study on the Safety Estimation of Wiring Connection Connector Manufactured by Housing Type)

  • 최충석
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.462-466
    • /
    • 2010
  • The purpose of this study is to evaluate the safety of a wire connector fabricated for the effective installation of a lighting fixture including its contact resistance, insulation resistance, withstanding voltage characteristics, etc., and to provide the basis for the analysis and judgment of PL(Product Liability) dispute by presenting a damage pattern due to a general flame and overcurrent. This study applied the Korean Standard (KS) for the incombustibility test of the connector using a general flame and performed an overcurrent characteristics test of the connector using PCITS (Primary Current Injection Test System). The contact resistance of the housing connector was measured using a high resistance meter and the insulation resistance was measured using a multimeter. In addition, a supply voltage of AC 1,500V for testing the withstanding voltage characteristics was applied to both ends of the connector. Measurement was performed on 5 specimens and the measured values were used as a basis for judgment. Since the connector is fabricated in the form of a housing, it can be connected and separated easily and has a structure that allows no foreign material to enter. In addition, since it has a structure that allows wires to be connected only when their polarity is identical, any misconnection that may occur during installation can be prevented. When the incombustibility test was performed by applying a general flame to the connector, it showed outstanding incombustibility characteristics and the blade and blade holder connected to the housing remained firmly secured even after the insulation sheath (PVC) was completely destroyed by fire. In addition, the mechanism of the damaged connecting wire showed a comparatively uniform carbonization pattern and it was found that some residual melted insulation material was attached to both ends. In the accelerated life test (ALT) to which approximately 500% of the rated current was applied, the connector damage proceeded in the order of white smoke generation, wire separation, spark occurrence and carbonization. That is, it could be seen that the connector damaged by overcurrent lost its own metallic color with traces of discoloration and carbonization. The contact resistance of the connector at a normal state was 2.164mV/A on average. The contact resistance measured after the high temperature test was 3.258mV/A. In addition, the insulation resistance after the temperature test was completed was greater than $10G\Omega$ and the withstanding voltage test result showed that no insulation breakdown occurred to all specimens showing stable withstanding voltage and insulation resistance characteristics.

An experimental study on fire resistance of medical modular block

  • Kim, Hyung-Jun;Lee, Jae-Sung;Kim, Heung-Youl;Cho, Bong-Ho;Xi, Yunping;Kwon, Ki-Hyuck
    • Steel and Composite Structures
    • /
    • 제15권1호
    • /
    • pp.103-130
    • /
    • 2013
  • Fire performance and fire safety of high-rise buildings have become major concerns after the disasters of World Trade Center in the U.S. in 2001 and Windsor tower in Spain in 2005. Performance based design (PBD) approaches have been considered as a better method for fire resistance design of structures because it is capable of incorporating test results of most recent fire resistance technologies. However, there is a difficulty to evaluate fireproof performance of large structures, which have multiple structural members such as columns, slabs, and walls. The difficulty is mainly due to the limitation in the testing equipment, such as size of furnace that can be used to carry out fire tests with existing criteria like ISO 834, BS 476, and KS F 2257. In the present research, a large scale calorie meter (10 MW) was used to conduct three full scale fire tests on medical modular blocks. Average fire load of 13.99 $kg/m^2$ was used in the first test. In the second test, the weighting coefficient of 3.5 (the fire load of 50 $kg/m^2$) was used to simulate the worst fire scenario. The flashover of the medical modular block occurred at 62 minutes in the first test and 12 minutes in the second test. The heat resistance capacity of the external wall, the temperatures and deformations of the structural members satisfied the requirements of fire resistance performance of 90 minutes burning period. The total heat loads and the heat values for each test are calculated by theoretical equations. The duration of burning was predicted. The predicted results were compared with the test results, and they agree quite well.

생태교량 적용을 위한 방수·방근공법의 Mock-up 시험 연구 (A Study on the Mock-up Test of Waterproofing/Root Penetration Resistance Technology for the Application to an Eco-bridge)

  • 선윤숙;최수영;김명지;최성민;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.230-231
    • /
    • 2014
  • This study is concerned with the root penetration resistance competence and constructability of a waterproofing and root penetration resistance layer of an eco-bridge which is applied with various types of seeding. For the review of root penetration resistance competence, the competence was tested using herbs, woody plants, and tall trees. As a result, there was no tear of or damage to the waterproofing and root penetration resistance layer as well as the sweeping-down phenomenon of a waterproofing and root penetration resistance layer by soil. Also, the effect of the root growth of herbs, woody plants, and tall trees on the root penetration resistance system was confirmed.

  • PDF

20대의 혈류제한 저항운동이 위팔두갈래근 활성도, 피로도 및 혈역학적 변인에 미치는 영향 (Effect of Blood Flow Restriction Resistance Exercise in Twenties on Biceps Activity, Fatigue and Hemodynamic Variables )

  • 정대근;강정일;박준수
    • 대한물리의학회지
    • /
    • 제18권1호
    • /
    • pp.15-24
    • /
    • 2023
  • PURPOSE: This study examined the effects of lowintensity resistance exercise combined with blood flow restriction on muscle activity and muscle fatigue to determine if such a combination may be an alternative to high-intensity resistance exercise in maintaining the muscle mass and strength and preventing degenerative loss of skeletal muscle and to provide basic data for presenting the effectiveness of exercise. METHODS: The interventions were provided for five weeks, four sessions a week, once a day, 60 minutes a session to Experimental group I (n = 13), in which low-intensity resistance exercise was applied by combining blood flow restriction with the biceps curl and experimental group II (n = 12), in which only high-intensity resistance exercise was applied. As a pre-test, the biceps brachii muscle activity and fatigue were measured by surface electromyography, and the hemodynamic variables, such as blood pressure and heart rate, were measured. The post-test was performed identically to the pre-test and compared and analyzed with the pre-test. RESULTS: A significant difference within-group was observed in the biceps brachii muscle activity and fatigue in experimental group I and only in biceps brachii activity in experimental group II. No significant differences were observed between the two groups. CONCLUSION: Since the low-intensity resistance exercise combined with blood flow restriction has similar effects to high-intensity resistance exercise, it is considered an alternative for improving muscle function in groups unable to perform high-intensity resistance exercise.

소형콘의 관입저항력을 이용한 점토의 액성한계측정에 관한 연구 (Study on the Measurement of Liquid Limit Using a Penetration Resistance of Small Cone in Clay Soil)

  • 손무락;이재용
    • 한국지반공학회논문집
    • /
    • 제32권10호
    • /
    • pp.5-15
    • /
    • 2016
  • 본 연구에서는 소형콘의 관입저항력을 이용한 점토의 액성한계를 측정하기 위하여 카올리나이트 점토와 벤토나이트 점토의 비율을 다양하게 혼합한 점토흙에 대하여 함수비와 소형콘의 관입저항력을 조사하고 기존의 동적(Casagrande 시험법) 및 정적(Fall cone 시험법) 액성한계 시험결과와 직접 비교하였다. 비교결과 다양한 점토흙의 함수비에 따른 관입저항력 관계곡선에서 변곡점이 형성된다는 것을 파악하였으며 이 때의 함수비가 정적액성한계(Fall cone)시험법에 의한 액성한계 값과 매우 유사함을 파악하였다. 변곡점이 형성된 점에서의 소형콘의 관입저항력은 약 0.2kPa로 나타났으며 이 때 의 함수비가 점토흙의 액성한계를 나타낸다는 것을 확인하였다. 이와 같은 연구결과를 토대로 향후 점토의 액성한계를 파악하는데 본 연구에서 조사된 0.2kPa의 소형콘의 관입저항력이 유용한 지표가 될 수 있다는 사실을 파악하였다. 또한 소형콘의 관입저항력을 이용한 액성한계 시험법을 제시하였다.

검증용 정재하시험을 이용한 타입강관말뚝의 저항계수 보정 (Local Resistance Factor Update of Driven Steel Pipe Piles Using Proof Pile Load Test Results)

  • 박재현;김동욱;정충기;김성렬
    • 대한토목학회논문집
    • /
    • 제31권6C호
    • /
    • pp.259-266
    • /
    • 2011
  • 기초구조물의 신뢰성 있는 저항계수 산정을 위해서는 충분한 양의 재하시험 결과에 근거한 저항의 분포특성 분석이 선행되어야 한다. 본 연구에서는 베이지안 이론에 근거하여 검증용 정재하시험 결과를 저항의 분포특성 분석에 반영할 수 있는 개선된 해석법을 제안하였고, 이를 통해 기 제안된 국내 타입강관말뚝의 저항계수를 갱신하였다. 측정 지지력이 확인된 정재하시험 결과를 이용하여 저항의 사전 분포특성을 산정하고, 검증용 정재하시험 결과를 우도정보로 고려하여 저항의 사후 분포특성을 평가하였다. 갱신된 저항의 사후 분포특성을 이용하여 일차신뢰도법에 의해 저항계수를 산정하였다. 총 5회의 검증용 재하시험 결과를 반영할 경우, 갱신된 저항계수는 목표신뢰도지수 2.33, 3.0에 대하여 각각 0.27-0.96, 0.19-0.68의 범위를 나타내었다. 본 연구에서 제시된 해석법을 통해 양질의 측정지지력 데이터가 부족하여 신뢰성 있는 저항계수를 산정하기 어려운 경우 현장 검증시험 결과를 반영한 저항계수의 보정이 가능함을 확인하였다.