• Title/Summary/Keyword: Resin tag

Search Result 60, Processing Time 0.024 seconds

A Modified Pretreatment with Deproteinization for Resin Infiltration in Early Childhood Caries (유아기우식증 치료를 위한 레진침투법에서 제단백제재의 사용)

  • Nam, Siyeon;Shin, Jonghyun;Jeong, Taesung;Kim, Shin;Kim, Jiyeon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.3
    • /
    • pp.290-298
    • /
    • 2018
  • This study aimed to evaluate surface morphology and resin tag penetration of resin infiltration into primary anterior teeth after enamel deproteinization with sodium hypochlorite (NaOCl) prior to phosphoric acid ($H_3PO_4$) etching. Ninety primary anterior teeth with non-cavitated caries lesion were devided five groups according to enamel pretreatment as follows, group I-15% hydrochloric acid (HCl) 2min. ; group II-5.25% NaOCl 1min., 35% $H_3PO_4$ 1min. ; group III-5.25% NaOCl 2min., 35% $H_3PO_4$ 1min. ; group IV-5.25% NaOCl 1min., 35% $H_3PO_4$ 2min. ; group V-5.25% NaOCl 2min., 35% $H_3PO_4$ 2min. Fifteen teeth were examined etched surface structure using field emission-scanning electron microscope. Seventy five teeth were infiltrated with resin, maximum penetration depth and percentage penetration were analysed using dual fluorescence confocal microscopy. As the application time of NaOCl increased, ratio of enamel type I, II were increased. Percentage penetration (PP) was higher in group V than group II, III (p < 0.05). PP of group IV, V did not show any differences. Non-cavitated caries of primary anterior teeth can be treated with resin infiltration. Enamel deproteinization with NaOCl prior to 35% $H_3PO_4$ etching could be an alternative of 15% HCl etching in resin infiltration.

Influence of Sodium Hypochlorite on Bond Strength of Dual-cured Core Build-up Resin Composite (이원중합형 코어 축조용 복합레진의 결합강도에 대한 NaOCI의 영향에 대한 연구)

  • Lee, Jun-Bong;Park, Jong-Duk;Kwon, Su-Mi;Yu, Mi-Kyung;Lee, Kwang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.4
    • /
    • pp.283-292
    • /
    • 2007
  • Two-step or one-step bonding systems generally inhibit curing process of dual-cured core build-up resin composite for their adhesive acidity. In addition this dual-cured core build-up resin composite can be applied to dentin of pulp chamber and root at the time that complete the endodontic treatment. The purpose of this investigation was to determine the influence of sodium hypochlorite on rnicrotensile bond strength of dual-cured core build-up resin composite. Extracted human molars were horizontally sectioned with 1mm thickness using low speed diamond saw. After the sectioned specimens were divided into 8 groups, adhesive systems (Clearfil SE-Bond, Prime&Bond NT[2-step, 1-step], Adper Prompt L-Pop) were then applied with or without sodium hypochlorite pretreatment. The treated specimen was filled with dual-cured core build-up resin composite (Luxacore, DMG corp., German). Then light cured for 40 seconds and soaked in $37^{\circ}C$ water bath for 24 hours. After the treated specimen was grinded with 1mm width and measured rnicrotensile bond strength by testing machine. Additionally 8 teeth were prepared for SEM evaluation. The results were as follows. : NaOCl treated groups generally had lower rnicrotensile bond strength but did not show any difference statistically except Adper Prompt L-Pop. When the teeth were treated by NaOCl, though the difference of applied adhesive system, it had no statistically significant difference within the NaOCl treated groups except the relation of between ClearFil SE-Bond adhesive system and Adper Prompt L-Pop adhesive system. In the SEM evaluation, NaOCl treated groups presented relatively long resin tags and incomplete hybrid layer formation generally.

Comparative evaluation of micro-shear bond strength between two different luting methods of resin cement to dentin (합착 술식에 따른 레진 합착제의 상아질에 대한 미세전단결합강도의 비교 연구)

  • Lee, Yoon-Jeong;Park, Sang-Jin;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.283-293
    • /
    • 2005
  • The purpose of this study was to evaluate the effect of dual bonding technique by comparing microshear bond strength between two different luting methods of resin cement to tooth dentin. Three dentin bonding systems(All-Bond 2, One-Step, Clearfil SE Bond), two temporary cements (Propac, Freegenol) were used in this study. In groups used conventional luting procedure, dentin surfaces were left untreated. In groups used dual bonding technique, three dentin bonding systems were applied to each dentin surface. All specimens were covered with each temporary cement. The temporary cements were removed and each group was treated using one of three different dentin bonding system. A resin cement was applied to the glass cylinder surface and the cylinder was bonded to the dentin surface. Then, micro-shear bond strength test was performed. For the evaluation of the morphology at the resin/dentin interface, SEM examination was also performed. 1. Conventional luting procedure showed higher micro-shear bond strengths than dual boning technique. However, there were no significant differences. 2. Freegenol showed higher micro-shear bond strengths than Propac, but there were no significant differences. 3. In groups used dual bonding technique, SE Bond showed significantly higher micro-shear bond strengths in One-Step and All-Bond 2 (p<0.05), but there was no significant difference between One-Step and All-Bond 2. 4. In SEM observation, with the use of All-Bond 2 and One-Step, very long and numerous resin tags were observed. This study suggests that there were no findings that the dual bonding technique would be better than the conventional luting procedure.

A STUDY OF ADDITIONAL VIBRATION EFFECT ON DENTIN BOND STRENGTH (진동이 상아질 결합력에 미치는 영향에 관한 연구)

  • Lee, Jin;Kim, Jung-Wook;Lee, Sang-Hoon;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.632-640
    • /
    • 2002
  • The objective of the study was to apply the vibration technique to reduce the viscosity of bonding adhesives and thereby compare the bond strength and resin penetration into dentinal tubules achieved with those gained using the conventional technique. Eighty-eight noncarious extracted human permanent molar teeth were sectioned to remove the coronal enamel and were embedded in 1-inch PVC pipe with acrylic resin. The occlusal surfaces were placed so that the tooth and the embedding medium were at the same level to form one flat surface, and the samples were subsequently polished with silicon carbide abrasive papers. The samples were randomly assigned to 4 groups(n=22). On Group 1 and 2, Single Bond(3M-ESPE, St. Paul, USA) was used, and on Group 3 and 4, One-Step(Bisco Inc., Schaumburg, USA) was used, and each was applied according to its manufacturer's instructions. For Group 2 and Group 4, vibration was applied with ultrasonic scaler for 10 seconds, and the adhesive was light-cured for 10 seconds. Resin composite was condensed on to the prepared surface in two increments using a mold kit(Ultradent Products Inc., USA) and each was light-cured for 40 seconds. After 24 hours in tap water at room temperature the specimens were thermocycled, and shear bond strengths were measured with a universal testing machine(Instron 4465, Canton, USA). To investigate infiltration patterns of the adhesive materials, the surface of specimen was examined with scanning electron microscope. The results were as follows. 1. The shear bond strengths of vibration groups(Group 2, Group 4) were significantly greater than those of the non-vibration groups(Group 1, Group 3)(p<0.05). 2. The shear bond strengths of Single Bond and One-Step were not significantly different (p>0.05). 3. The vibration groups showed greater number of resin tags in tubules and lateral branches under SEM.

  • PDF

RHEOLOGICAL PROPERTIES OF RESIN COMPOSITES ACCORDING TO THE CHANGE OF MONOMER AND FILLER COMPOSITIONS (단량체 및 무기질 filler 조성 변화에 따른 복합레진의 유변학적 특성)

  • Lee In-Bog;Lee Jong-Hyuck;Cho Byung-Hoon;Son Ho-Hyun;Lee Sang-Tag;Um Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.6
    • /
    • pp.520-531
    • /
    • 2004
  • The aim of this study was to investigate the effect of monomer and filler compositions on the rheological properties related to the handling characteristics of resin composites. Methods. Resin matrices that Bis-GMA as base monomer was blended with TEGDMA as diluent at various ratio were mixed with the Barium glass (0.7 um and 1.0 um), 0.04 um fumed silica and 0.5 um round silica. All used fillers were silane treated. In order to vary the viscosity of experimental composites, the type and content of incorporated fillers were changed, Using a rheometer, a steady shear test and a dynamic oscillatory shear test were used to evaluate the viscosity ($\eta$) of resin matrix, and the storage shear modulus (G'), the loss shear modulus (G"), the loss tangent ($tan{\delta}$) and the complex viscosity (${\eta}^*$) ofthe composites as a function of frequency ${\omega}{\;}={\;}0.1-100{\;}rad/s$. To investigate the effect of temperature on the viscosity of composites, a temperature sweep test was also undertaken. Results. Resin matrices were Newtonian fluid regardless of diluent concentration and all experimental composites exhibited pseudoplastic behavior with increasing shear rate. The viscosity of composites was exponentially increased with increasing filler volume%. In the same filler volume, the smaller the fillers were used, the higher the viscosities were. The effect of filler size on the viscosity was increased with increasing filler content. Increasing filler content reduced $tan{\delta}$ by increasing the G' further than the G". The viscosity of composites was decreased exponentially with increasing temperature.

THE ETCHING EFFECTS AND MICROTENSILE BOND STRENGTH OF TOTAL ETCHING AND SELF-ETCHING ADHESIVE SYSTEM ON UNGROUND ENAMEL (법랑질에 대한 total etching과 self-etching 접착제의 산부식 효과와 미세인장결합강도)

  • Oh, Sun-Kyong;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.3
    • /
    • pp.273-280
    • /
    • 2004
  • The purpose of this study was to evaluate the etching effects and bond strength of total etching and self-etching adhesive system on unground enamel using scanning electron microscopy and microtensile bond strength test. The buccal coronal unground enamel from human extracted molars were prepared using low-speed diamond saw. Scotchbond Multi-Purpose (group SM). Clearfil SE Bond (group SE), or Adper Prompt L-Pop (group LP) were applied to the prepared teeth. and the blocks of resin composite (Filtek Z250) were built up incrementally. Resin tag formation was evaluated by scanning electron microscopy. after removal of enamel surface by acid dissolution and dehydration. For microtensile bond strength test. resin-bonded teeth were sectioned to give a bonded surface area of $1\textrm{mm}^2$. Microtensile bond strength test was perfomed. The results of this study were as follows. 1. A definite etching pattern was observed in Scotchbond Multi-Purpose group. 2. Self-etching groups were characterized as shallow and irregular etching patterns. 3. The results (mean) of microtensile bond strength were SM: 26.55 MPa, SE: 18.15 MPa, LP: 15.57 MPa. SM had significantly higher microtensile bond strength than 8E and PL (p < 0.05). but there was no significant differance between SE and PL.

The Fundamental Study of Strength on the CFRP Pipe Reinforced Rib (Rib CFRP 파이프의 강도에 관한 기초적 연구)

  • Seo, Sung-Tag
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.13 no.1
    • /
    • pp.41-47
    • /
    • 2010
  • The carbon fiber reinforced plastics, one of unidirectional fiber-reinforced composite materials, are widely used in various field including space and aviation industries, sports and leisure industries and general structural members and parts as have high strength in comparison with the weight, elasticity coefficient, high fatigue strength and lower thermal transformation. This paper present analytical behavior of CFRP pipe reinforced rib under the external force. From the results, the maximum compressive stress occurs at the upper flange of CFRP pipe and tensile stress occurs middle flange of the CFRP pipe. The stress of rib CFRP pipe by increasing effective cross-sectional area was reduced by approximately 35%.

  • PDF

The Influence of acid rein upon Tracking resistance of Epoxy Composite Materials (에폭시 복합재료의 내트래킹성에 미치는 산성비의 영향)

  • Son, In-Hwan;Kim, Tag-Yong;Choi, Seong-Min;Kim, Kyung-Hwan;Kim, Jae-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1813-1815
    • /
    • 1997
  • In this study, in order to develop outdoor insulating materials, SIN(simultaneous interpenetrating polymer network) was introduced to Epoxy resin and the environment resistance was investigated. Six kinds of specimen were manufacture by filler($SiO_2$) content. SEM was untilized in order to confirm their network structure changes. Also, tracking test, UV test and acid rain test were carried out investigate the environment resistance characteristic. Therefore it was confirmed that simultaneous interpenetrating polymer network specimens were more excellent than single network structure specimens. But, acid rain almost never changed resistance.

  • PDF

An Experimental Study on the Effect of Laser to Bond Strength between Composite Resin and Bovine Teeth (우치치질에 레이저조사시 레진과의 결합강도에 관한 연구)

  • Cho, Ju-On;Song, Kwang-Yeob;Park, Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.2
    • /
    • pp.155-172
    • /
    • 1989
  • The purpose of this study is to measure the bonding strength at the enamel and dentin of extracted bovine incisors when they are irradiated by W Nd: YAG, EoQ Nd: YAG, and CW $CO_2$ laser, etched and then attached by composite resin. The laser-irradiated surface, the etched surface after the laser-irradiation and the interface of the treated surface and resin are observed by using scanning electron microscope. The NP Nd:YAG laser is used at the peam power of 207 KW. The EOQ Nd: YAG laser is used at the peak power of 1.15Mk. The CW $CO_2$ laser is used at the energy output of 5W and 10W in enamel; in dentin, at the energy output of 2W. The obtained results were as follows: 1. The shear bond strength of enamel decreased in the following order: EOQ Nd:YAG laser group, NP Nd:YAG laser group, CW $CO_2$ laser groups, unlased group. The unlased group showed a significant difference from EOQ Nd:YAG laser group (P<0.01), NP Nd:YAG laser group (P<0.05), but no significant difference from CW $CO_2$ laser group (P>0.05). 2. The shear bond strength of dentin decreased in the following order: CW $CO_2$ laser group, NP Nd:YAG laser group, unlased group, EOQ Nd:YAG laser group. The unlased group showed a significant difference from CW $CO_2$ laser group (P<0.01), but no significant difference from Nd:YAG laser groups (P>0.05). 3. The scanning electron microscope of enamel revealed irregular microcrack and pore at the surface in the NP Nd:YAG laser group and CW $CO_2$ laser group, but the crackless flat surface in the EOQ Nd:YAG laser group. 4. The scanning electron microscope of dentin revealed obstruction of in most of dentinal tubule and decrease of diameter. 5. The scanning electron microscope of the interface of resin and enamel revealed prominent penetration of resin tag in the EOQ Nd:YAG laser group.

  • PDF

SHEAR BOND STRENGTH OF "ONE-BOTTLE ADHESIVE" SYSTEM IN PRIMARY DENTIN. (One-Bottle 상아질 결합제의 유치 상아질에 대한 전단 결합 강도에 관한 연구)

  • Kim, Jong-Bin;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.3
    • /
    • pp.444-456
    • /
    • 2000
  • To test the shear bond strength of a new "one-bottle adhesive" system to primary dentin two commercially available one-bottle adhesives (Prime & Bond NT, Single bond) and conventional three step system(Scotchbond Multi-Purpose Plus) were included for comparison. And We observe the interfacial morphology by scanning electron microscope. 90 primary molar teeth were embedded in acrylic and buccal and lingual surface were polished to 320 grit to create standardized dentin surface for testing. After bonding of composite resin to sample surfaces according to the manufacturer s direction and 1000 times thermocycling in dwell time 30 second, Shear bond strengths of adhesives to dentin were determined using universal testing machine and analyzed by ANOVA test. Another groups of specimens were treated by hydrochloric acid to secure the resin only and those tags were evaluated under SEM for their length and forms and the morphology of the bonding sites were also observed. The result are as follows. 1. Group I(Prime & Bond NT) showed higher shear bond strength than group iI(Single Bond) and III(Scotchbond Multi Purpose Plus) but no statistically significant difference was founded between groups(p>.05). 2. Relating long resin tags of $70-120{\mu}m$ were observed in samples of all groups under SEM. We could observed hybrid layer, resin tag and many lateral branches in every group. But, we observed in group III rare lateral branched than other two group and discontinuous hybrid layer.

  • PDF