Water Quality Variation and Corrosion Index Characteristics of Underground Reservoir in Apartment (공동주택 지하저수조의 수질변화 및 부식성 특성)

  • JunYoung, Jang;JooWon, Kim;YuHoon, Hwang;KiPal, Kim;HyunSang, Shin;ByungRan, Lim
    • Journal of Korean Society on Water Environment
    • /
    • v.38 no.6
    • /
    • pp.275-281
    • /
    • 2022
  • To maintain water quality after water treatment, monitoring whether the quality of treated tap water quality changes is essential. However, current investigations are insufficient to prevent secondary contamination in drinking water supply systems. This study investigated Gyeonggi's e apartment where a red water problem occurred and monitored the water quality and corrosiveness of the overall water supply system to the apartment from June 2021 to April 2022. In a comparison of drinking water quality after water treatment and the influent of the reservoir, turbidity and heavy metal concentrations were increased and residual chlorine was decreased due to increases in temperature. Correlation analysis and principal component analysis (PCA) indicated that a low level of residual chlorine may cause the abscission of Mn2+ and Fe2+ through microorganism activation, which also causes a high level of turbidity. The corrosion index (LI) in the influent of the reservoir tank was increased due to Ca2+ and temperature. These results indicate that the corrosiveness of drinking water and the deterioration of drinking water quality were mainly increased between the drinking water treatment plant and the reservoir tank's influent. The findings provide clear evidence that it is essential to manage water supply systems and reservoir tanks to prevent the secondary contamination of drinking water.

Polluted Water Treatment of Dam and Reservoir using Natural Korean Zeolite (천연 제올라이트 활용을 통한 댐 및 호소의 오염수 처리)

  • Park, Ki-Ho;Suh, Jin-Kook
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.8 no.2
    • /
    • pp.113-120
    • /
    • 2005
  • Due to the Typhoon MAEMI on Sep. of 12 in 2003, the turbidity value of DOAM Dam was recorded more than 300NTU until now. The natural zeolite located in the east coast of Korean peninsula was applied to reduce turbidity with cation exchange process. The result of this technique, the value of turbidity was reduced less than 1NTU. Also the value of pH showed stable state compare to before and after.

  • PDF

Determination of Optimum Coagulants (Ferric Chloride and Alum) for Arsenic and Turbidity Removal by Coagulation

  • Choi, Young-Ik;Jung, Byung-Gil;Son, Hee-Jong;Jung, Yoo-Jin
    • Journal of Environmental Science International
    • /
    • v.19 no.8
    • /
    • pp.931-940
    • /
    • 2010
  • The Raw water from Deer Creek (DC) reservoir and Little Cottonwood Creek (LCC) reservoir in the Utah, USA were collected for jar test experiments. This study examined the removal of arsenic and turbidity by means of coagulation and flocculation processes using of aluminum sulfate and ferric chloride as coagulants for 13 jar tests. The jar tests were performed to determine the optimal pH range, alum concentration, ferric chloride concentration and polymer concentration for arsenic and turbidity removal. The results showed that a comparison was made between alum and ferric chloride as coagulant. Removal efficiency of arsenic and turbidity for alum (16 mg/L) of up to 79.6% and 90.3% at pH 6.5 respectively were observed. Removal efficiency of arsenic and turbidity for ferric chloride (8 mg/L) of up to 59.5% at pH 8 and 90.6% at pH 8 respectively were observed. Optimum arsenic and turbidity removal for alum dosages were achieved with a 25 mg/L and 16 mg/L respectively. Optimum arsenic and turbidity removal for ferric chloride dosages were achieved with a 20 mg/Land 8 mg/L respectively. In terms of minimizing the arsenic and turbidity levels, the optimum pH ranges were 6.5 and 8for alum and ferric chloride respectively. When a dosage of 2 mg/L of potassium permanganate and 8 mg/L of ferric chloride were employed, potassium permanganate can improve arsenic removal, but not turbidity removal.

Modeling Study of Turbid Water in the Stratified Reservoir using linkage of HSPF and CE-QUAL-W2 (HSPF와 CE-QUAL-W2 모델의 연계 적용을 이용한 용담댐 저수지 탁수현상의 모델 연구)

  • Yi, Hye-Suk;Jeong, Sun-A;Park, Sang-Young;Lee, Yo-Sang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.1
    • /
    • pp.69-78
    • /
    • 2008
  • An integration study of watershed model(HSPF, Hydological Simulation program-Fortran) and reservoir water quality model (CE-QUAL-W2) was performed for the evaluation of turbid water management in Yongdam reservoir. The watershed model was calibrated and analyzed for flow and suspended solid concentration variation during rainy period, their results were inputted for reservoir water quality model as time-variable water temperature and turbidity. Results of the watershed model showed a good agreement with the field measurements of flow and suspended solid. Also, results of the reservoir water quality model showed a good agreement with the filed measurements of water balance, water temperature and turbidity using linkage of the watershed model results. Integration of watershed and reservoir model is an important in turbid water management because flow and turbidity in stream and high turbidity layer in reservoir could be predicted and analyzed. In this study, the integration of HSPF and CE-QUAL-W2 was applied for the turbid water management in Yongdam reservoir, where it is evaluated to be appliable and important.

Laterally-Averaged Two-Dimensional Hydrodynamic and Turbidity Modeling for the Downstream of Yongdam Dam (용담댐 하류하천의 횡방향 평균 2차원 수리·탁수모델링)

  • Kim, Yu Kyung;Chung, Se Woong
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.5
    • /
    • pp.710-718
    • /
    • 2011
  • An integrated water quality management of reservoir and river would be required when the quality of downstream river water is affected by the discharge of upstream dam. In particular, for the control of downstream turbidity during flood events, the integrated modeling of reservoir and river is effective approach. This work was aimed to develop a laterally-averaged two-dimensional hydrodynamic and water quality model (CE-QUAL-W2), by which water quality can be predicted in the downstream of Yongdam dam in conjunction with the reservoir model, and to validate the model under two different hydrological conditions; wet year (2005) and drought year (2010). The model results clearly showed that the simulated data regarding water elevation and suspended solid (SS) concentration are well corresponded with the measured data. In addition, the variation of SS concentration as a function of time was effectively simulated along the river stations with the developed model. Consequently, the developed model can be effectively applied for the integrated water quality management of Yongdam dam and downstream river.

Investigating the Causes and Control Measures for Precipitated Suspended Solids in the Underground Reservoir Tank in an Apartment (공동주택 지하저수조 내 침전된 부유성 고형물의 발생원인 및 제어방안)

  • JunYoung Jang;JooWon Kim;KiPal Kim;HyunSang Shin;ByungRan Lim
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.2
    • /
    • pp.153-161
    • /
    • 2023
  • The reservoir tank in an apartment is crucial for maintaining the quality of drinking water after it has undergone treatment. Investigating the water quality and potential contaminants in the reservoir tank is essential to ensure the safety of the drinking water. This study examined the water quality and precipitated suspended solids that accumulate at the bottom of the reservoir tanks in four apartments located in Gyeonggi province. As a result of the water quality investigation, turbidity increased proportionally to the distance from the water treatment plant (WTP) to the household. Heavy metals were also detected in the reservoir tank inlet but not in the water supplied from the WTP. The precipitated suspended solids (SS) in the reservoir tank contain high levels of heavy metals and total organic carbon (TOC). The precipitated SS mainly consists of Al, Mn, and Fe, which are expected to be a combination with turbidity-inducing substances. The X-ray diffraction (XRD) analysis revealed the presence of γ-FeO(OH), MnO2, and β-Fe2O3 in the SS. Additionally, F-EEM analysis indicates that the dissolved organic matter in the SS is mainly derived from a natural water source and microorganism activities, including metal-oxidizing bacteria and biofilms that can absorb metal ions. Based on these findings, several countermeasures can be taken to prevent the inflow of SS into the household, including regularly cleaning the reservoir tank, replacing or cleaning old pipes in the water supply system, and implementing monitoring and filtering systems to manage the SS.

Evaluation of SELECT Model for the Quality Prediction of Water Released from Stratified Reservoir (성층화된 저수지의 방류수 수질예측을 위한 SELECT 모델의 적용성 검토)

  • Lee, Heung Soo;Chung, Se Woong;Shin, Sang Il;Choi, Jung Kyu;Kim, Yu Kyung
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.591-599
    • /
    • 2007
  • The quality of water released from a stratified reservoir is dependent on various factors such as the location and shape of intake facility, structure of reservoir stratification, profile of water quality constituent, and withdrawal flux. Sometimes, selective withdrawal capabilities can provide the operational flexibility to meet the water quality demands both in-reservoir and downstream. The objective of this study was to evaluate the performance of a one-dimensional reservoir selective withdrawal model (SELECT) as a tool for supporting downstream water quality management for Daecheong and Imha reservoirs. The simulated water quality variables including water temperature, dissolved oxygen (DO), conductivity, turbidity were compared with the field data measured in tailwater. The model showed fairly satisfactory results and high reliability in simulating observations. The coefficients of determinant between simulated and observed turbidity values were 0.93 and 0.95 for Daecheong and Imha reservoirs, respectively. The outflow water quality was significantly influenced by water intake level under fully stratified condition, while the effect of intake amount was minor. In conclusion, the SELECT is simple but effective tool for supporting downstream water quality prediction and management for both reservoirs.

Impact of Climate Change on Water Cycle and Soil Loss in Daecheong Reservoir Watershed (기후변화에 따른 대청호 유역의 물 순환 및 토양 유실량 영향)

  • Ye, Lyeong;Chung, Se Woong;Oh, Dong Geun;Yoon, Sung Wan
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.821-831
    • /
    • 2009
  • The study was aimed to assess the expected impact of climate change on the water cycle and soil losses in Daecheong Reservoir watershed, Korea using the Soil and Water Assessment Tool (SWAT) that was validated for the watershed in a previous study. Future climate data including precipitation, temperature and humidity generated by introducing a regional climate model (Mesoscale Model Version 5, MM5) to dynamically downscale global circulation model (European Centre Hamburg Model Version 4, ECHAM4) were used to simulate the hydrological responses and soil erosion processes in the future 100 years (2001~2100) under the Special Report on Emissions Scenario (SRES) A1B. The results indicated that the climate change may increase in the amount of surface runoff and thereby sediment load to the reservoir. Spatially, the impact was relatively more significant in the subbasin Bocheongcheon because of its lower occupation rate of forest land compared to other subbasins. Seasonally, the increase of surface runoff and soil losses was more significant during late summer and fall season when both flood control and turbidity flow control are necessary for the reservoir and downstream. The occurrence of extreme turbidity flow events during these period is more vulnerable to reservoir operation because the suspended solids that remained water column can be resuspended by vertical mixing during winter turnover period. The study results provide useful information for the development of adaptive management strategy for the reservoir to cope with the expected impact of future climate change.

Effect of Installing a Selective Withdrawal Structure for the Control of Turbid Water in Soyang Reservoir (탁수조절을 위한 소양호 선택취수설비 설치 효과 분석)

  • Chung, Se Woong;Park, Hyung Seok;Yoon, Sung Wan;Ryu, In Gu
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.6
    • /
    • pp.743-753
    • /
    • 2011
  • One of the most important water management issues of Soyang Reservoir, located in North Han River in Korea, is a long term discharge of turbid water to downstream during flood season. Installation of a selective withdrawal structure (SWS) is planned by the reservoir management institute as a control measure of outflow water quality and associated negative impacts on downstream water use and ecosystem. The objective of the study was to explore the effectiveness of the SWS on the control of outflow turbidity under two different hydrological years; one for normal flood year and another for extreme flood year. A two-dimensional (2D), laterally averaged hydrodynamic and water quality model (CE-QUAL-W2) was set up and calibrated for the reservoir and used to evaluate the performance of the proposed SWS. The results revealed that the SWS can be an effective method when the ${\Theta}$ value, the ratio between the amount of turbid water that containing suspended sediment (SS) greater than 25 mg/L and the total storage of the reservoir, is 0.59 during the normal flood year. However, the effectiveness of the SWS could be marginal or negative in the extreme flood year when ${\Theta}$ was 0.83. The results imply that the SWS is an effective alternative for the control of turbid water for moderate flood events, but not a sufficient measure for large flood events that are expected to happen more often in the future because of climate change.

The Variation of Water Temperature and Turbidity of Stream Flows entering Imha Reservoir (임하호 유입지천의 수온과 탁도 변화)

  • Kim, Woo-Gu;Jung, Kwan-Soo;Yi, Yong-Kon
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.1 s.115
    • /
    • pp.13-20
    • /
    • 2006
  • The changing patterns of water temperature and turbidity in streams entering Imha Reservoir were studied. The turbidity variation near the intake tower in Imha Reservoir was investigated in relation with the variation of water temperature and turbidity in streams. Water temperature was estimated using multi-regression method with air temperature and dew point as independent variables. Peak turbidity was also estimated using non-linear regression method with rainfall intensity as an independent variable. Although more independent variables representing watershed characteristics seem to be needed to increase estimation accuracies, the methodology used in this study can be applied to estimate water temperature and peak turbidity in other streams.