Browse > Article
http://dx.doi.org/10.15681/KSWE.2022.38.6.275

Water Quality Variation and Corrosion Index Characteristics of Underground Reservoir in Apartment  

JunYoung, Jang (Department of Environment Engineering, Seoul National University of Science and Technology)
JooWon, Kim (Department of Environment Engineering, Seoul National University of Science and Technology)
YuHoon, Hwang (Department of Environment Engineering, Seoul National University of Science and Technology)
KiPal, Kim (K-1ecotech Co,, Ltd)
HyunSang, Shin (Department of Environment Engineering, Seoul National University of Science and Technology)
ByungRan, Lim (Department of Environment Engineering, Seoul National University of Science and Technology)
Publication Information
Abstract
To maintain water quality after water treatment, monitoring whether the quality of treated tap water quality changes is essential. However, current investigations are insufficient to prevent secondary contamination in drinking water supply systems. This study investigated Gyeonggi's e apartment where a red water problem occurred and monitored the water quality and corrosiveness of the overall water supply system to the apartment from June 2021 to April 2022. In a comparison of drinking water quality after water treatment and the influent of the reservoir, turbidity and heavy metal concentrations were increased and residual chlorine was decreased due to increases in temperature. Correlation analysis and principal component analysis (PCA) indicated that a low level of residual chlorine may cause the abscission of Mn2+ and Fe2+ through microorganism activation, which also causes a high level of turbidity. The corrosion index (LI) in the influent of the reservoir tank was increased due to Ca2+ and temperature. These results indicate that the corrosiveness of drinking water and the deterioration of drinking water quality were mainly increased between the drinking water treatment plant and the reservoir tank's influent. The findings provide clear evidence that it is essential to manage water supply systems and reservoir tanks to prevent the secondary contamination of drinking water.
Keywords
Corrosion index; Drinking water; Turbidity; Underground reservoir; Water quality;
Citations & Related Records
Times Cited By KSCI : 6  (Citation Analysis)
연도 인용수 순위
1 Geldreich, E. E. (2020). Microbial quality of water supply in distribution systems, CRC Press, Boca Raton, 1-22.
2 Gyeonggi Water Information System. (2022). Water quality monitoring data, https://water.gg.go.kr/ (accessed Jun. 2022).
3 Han, K. S., Park, J. H., Park, Y. B., Kim, S. J., Kim, H. D., Choi, Y. J., Choi, I. C., and Hong, S. H. (2018). Effect of residual chlorine concentration on water pipe corrosion and corrosion control plan, Corrosion Science and Technology, 17(1), 12-19. [Korean Literature]   DOI
4 Hoseinzadeh, E., Yusefzadeh, A., Rahimi, N., and Khorsandi, H. (2013). Evaluation of corrosion and scaling potential of a water treatment plant, Archives of Hygiene Sciences, 2(2), 41-47.
5 Hu, J., Dong, H., Xu, Q., Ling, W., Qu, J., and Qiang, Z. (2018). Impacts of water quality on the corrosion of cast iron pipes for water distribution and proposed source water switch strategy, Water Research, 129, 428-435.   DOI
6 Hwang, B. G. and Woo, D. S. (2011). Corrosion control technique for pipeline system through injecting water stabilizer, Journal of the Korea Academia-Industrial Cooperation Society, 12(1), 545-551. [Korean Literature]   DOI
7 Jun, M. H. and Kim, D. H. (2016). A study on water quality variation of tap water in drinking water distribution systems, Annual Report of Gyeongsangnam-do Government Institute of Health and Environment, 14, 272-283. [Korean Literature]
8 Kim, D. H., Kim, Y. J., Son, H. J., Ryou, D. C., Ahn, J. Y., Kim, C., and Hwang, I. S. (2018). Effect of corrosive water quality control and corrosion index monitoring in pilot scale pipeline simulator, Journal of Korean Society of Water and Wastewater, 32(2), 183-192. [Korean Literature]   DOI
9 Kim, D. H., Lee, D. J., Hwang, J. S., and Choi, D. Y. (2013). Characteristic analysis and effect of particulate material in drinking water distribution networks, Journal of Korean Society of Environmental Engineers, 35(5), 312-320. [Korean Literature]   DOI
10 Kim, J. and Lee, J. (2014). Improvement of tap water corrosivity by lime and carbon dioxide, Journal of Korean Society of Water and Wastewater, 28(6), 725-733. [Korean Literature]   DOI
11 Kim, M., Hyun, S., Lee, W. S., and Loretta, Y. L. (2017). The regulations and guidelines for management of corrosive water and pipe corrosion in drinking water distribution system in North America, Journal of Korean Society on Water Environment, 33(3), 359-369. [Korean Literature]   DOI
12 Korea Law Information Center. (2021). Standard for drinking water test, https://www.law.go.kr/LSW//main.html (accessed Jun. 2022).
13 Lee, C. (2015). Energy-saving and environmental evaluation of water supply system on replacing water storage installed booster pump system by direct connecting booster pump system, Journal of the Korean Society for Geothermal and Hydrothermal Energy, 11(3), 7-12. [Korean Literature]   DOI
14 Lee, H. D., Hwang, J. W., Bae, C. H., and Kim, S. J. (2004). Assessment of variable characteristics in water quality of the supply systems in the building, Journal of Korean Society on Water Environment, 20(4), 313-320. [Korean Literature]
15 Lee, J. W., Noh, Y. R., and Park, J. H. (2017). Influences of pH on Heavy Metal Leaching in Water Supply Pipelines, Journal of Civil and Environmental Engineering Research, 37(1), 73-82. [Korean Literature]
16 Li, G., Ma, X., Chen, R., Yu, Y., Tao, H., and Shi, B. (2019). Field studies of manganese deposition and release in drinking water distribution systems: Insight into deposit control, Water Research, 163, 114897.
17 Noh, Y. R., Kim, S. H., Choi, S. U., and Park. J. H. (2016). A review study on major factors influencing chlorine disappearances in water storage tanks, Journal of Korean Society of Disaster & Security, 9(2), 63-75. [Korean Literature]   DOI
18 Liu, C. W., Lin, K. H., and Kuo, Y. M. (2003). Application of factor analysis in the assessment of groundwater quality in a blackfoot disease area in Taiwan, Science of the Total Environment, 313(3), 77-89.   DOI
19 Masters, S., Welter, G. J., and Edwards, M. (2016). Seasonal variations in lead release to potable water, Environmental Science & Technology, 50(10), 5269-5277.   DOI
20 Ministry of Environment (ME). (2020). Statistics for water supply in 2020, http://www.me.go.kr/search/totalSearch/search.jsp (accessed Jun. 2022).
21 Park. J. H., Chung, H. M., Huh, Y. J., Choi, I. C., Ahn, K. H., Min, B. D., Yang, M. H., Shin, H. J., Park, Y. B., Choi, Y. J., Im, H. T., Song, M. S., and Lee, E. S. (2014). Corrosion control of distribution system in drinking water, NIER-RP2014-307, National Institute of Environmental Research, 1-2. [Korean Literature]
22 Proctor, C. R., Rhoads W. J.,, Keane, T., Saleh M., Hamilton, K., Pieper, K. J., Cweirtny, D. M., Prevost. M., and Whelton, A. J. (2020). Considerations for large building water quality after extended stagnation, Journal of American Water Works Association, 2(4), e1186.
23 Qiu, W., Li, W., He, J., Zhao, H., Liu, X., and Yuan, Y. (2018). Variations regularity of microorganisms and corrosion of cast iron in water distribution system, Journal of Environmental Sciences, 74, 177-185.   DOI
24 Wong, E. Y. and Stenstrom, M. K. (2018). Onsite defluoridation system for drinking water treatment using calcium carbonate, Journal of Environmental Management, 216, 270-274.   DOI
25 Bae, S. M.,, Kim, D . H.,, Son, H. J., Choi, D . H., Kim, I. S., and Kim, K. A. (2015). The monitoring of corrosive water quality in water distribution system by corrosion characteristics of raw and tap water, Journal of Environmental Science International, 24(7), 907-915. [Korean Literature]   DOI
26 Cho, Y. M., Seo, Y. W., Meng, S. K., and Hong, I. S. (2020). Improving the safety of tap water in Gyeonggi-do, GRI publication No. 2020-50, Gyeonggi Research Instsitute (GRI), 1-16. [Korean Literature]
27 Ahn, J. C., Lee, S. W., Rho, B. S., Choi, Y. J., Choi, J. H., Kim, H. I., Park, T. J., Park, C. M., Park, H., and Koo, J. Y. (2007). Modeling residual chlorine and THMs in water distribution system, Journal of Korean Society Environmental Engineer, 29(6), 706-714. [Korean Literature]
28 Anyang Water Service. (2022). Water quality test results for Anyang city, https://water.anyang.go.kr/ (accessed May. 2022).
29 Cynthia, A. S. and James R. M. (2012). Effect of storage tank material and maintenance on household water quality, Journal of American Water Works Association, 104(9), 521-529.
30 Dargahi, A., Shokri, R., Mohammadi, M., Azizi, A., Tabandeh, L., Jamshidi, A., and Beidaghi, S. (2016). Investigating of the corrosion and deposition potentials of drinking water sources using corrosion index: a case study of Dehloran. Journal of Chemical and Pharmaceutical Sciences, 974, 2115.
31 Dietrich, A. M. and Burlingame, G. A. (2015). Critical review and rethinking of USEPA secondary standards for maintaining organoleptic quality of drinking water, Environmental Science & Technology, 49(2), 708-720.   DOI
32 Gaspar, F. L., Pinheiro, B. R., Noriega, C. E. D., Araujo, M., Lefevre, N., and Montes, M. D. J. F. (2018). Alkalinity, inorganic carbon and CO2 flux variability during extreme rainfall years (2010-2011) in two polluted tropical estuaries NE Brazil, Brazilian Journal of Oceanography, 66, 115-130.   DOI