• 제목/요약/키워드: Research level

검색결과 34,951건 처리시간 0.059초

Trend and Analysis of Protection Level Calculation Methods for Centimeter-Level Augmentation System in Maritime

  • Jaeyoung Song;TaeHyeong Jeon;Gimin Kim;Sang Hyun Park;Sul Gee Park
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제12권3호
    • /
    • pp.281-288
    • /
    • 2023
  • The International Maritime Organization (IMO) states that the recommended horizontal accuracy for coastal and offshore areas is 10 m, the Alert Limit (AL) is 25 m, the time to alert is 10 seconds, and the integrity risk (IR) is 10-5 per three hours. For operations requiring high accuracy, such as tugs and pushers, icebreakers, and automated docking, the IMO dictates that a high level of positioning accuracy of less than one meter and a protection level of 0.25 meters (for automated docking) to 2.5 meters should be achieved. In this paper, we analyze a method of calculating the user-side protection level of the centimeter-level precision Global Navigation Satellite System (GNSS) that is being studied to provide augmentation information for the precision Positioning, Navigation and Timing (PNT) service. In addition, we analyze standardized integrity forms based on RTCM SC-134 to propose an integrity information form and generate a centimeter-level precise PNT service plan.

RADAR level measurement in Joule heated ceramic melter: A novel technique

  • Suneel, G.;Mahashabde, Mukesh;Borkotoky, Ritusmita;Sharma, Nitin Kumar;Pradeep, M.P.;Gayen, J.K.;Pimparkar, H.R.;Ravi, K.V.
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1176-1180
    • /
    • 2021
  • The current study relates to RADAR (RAdio Detection and Ranging) application for level measurement of vitrified radioactive liquid nuclear waste. The vitrification of radioactive liquid waste is carried out in special equipment called 'Melters'. The study is directed towards the design and frequency modulation used in the level measurement of vitrified waste. More specifically, the RADAR design and frequency used for level measurement in a melter. This level measurement technique can also be used for dynamic vitrification process and can be used to measure the level variations without using any external medium/material and using only electromagnetic waves. Also, this technique is durable and accurate even under the high radioactive environment present inside the melter.

대중교통수단에서 PM10, PM2.5 및 CO2의 농도 현황과 저감기술 개발에 관한 연구 (Characteristics of PM10, PM2.5 and CO2 Concentration in Public Transportations and Development of Control Technology)

  • 박덕신;권순박;조영민;장성기;전재식;박은영
    • 한국입자에어로졸학회지
    • /
    • 제6권1호
    • /
    • pp.9-20
    • /
    • 2010
  • This study examined the concentration level of the major air pollutants in public transportation. The study was conducted between February 2009 and March 2008 at Suwon-Yeosu line in Korea. $PM_{10}$ concentration level was $100{\mu}g/m^3$ on average. The $PM_{2.5}$ to PM10 ratio in transport is 0.37, which was lower than the results published by other researches. The result also demonstrated that outdoor $PM_{10}$ concentration was about 56~60% level compared to that of the cabin. $CO_2$ concentration level in the cabin was 1,359ppm, which does not exceed 2,000ppm, which is the guideline concentration level according to the Ministry of Environment. $CO_2$ concentration level in the cabin was $CO_2=23.4{\times}N+460.2$, and about 23.4ppm in $CO_2$ concentration level increased every time one passenger was added on. The experiment conducted on the train demonstrated that the average $PM_{10}$ concentration level was $100{\mu}g/m^3$ in case of the reference cabin while average $PM_{10}$ concentration level of the modified vehicle was $68{\mu}g/m^3$. Likewise, effect of the particle reduction device for the reduction of $PM_{10}$ concentration level was approximately 21%. Meanwhile there was almost no difference in the concentration level between reference and modified cabin in case of $PM_{2.5}$. Using zeolite as an adsorbent was made to reduce the $CO_2$ concentration level in the cabin. Number of passengers was factored in, to calculate the effect of the adsorption device, which demonstrated that about 36% of $CO_2$ concentration level was reduced in the modified cabin effect of the $CO_2$ reduction device. This research analyzed the current status concerning the quality of air in the public transportation and technologies were developed that reduces major air pollutants.

생물안전 3등급 연구 시설의 검증 사례 (A Case Study of Biosafety Level-3 Research Facilities Validation)

  • 주영덕;김진손;손익수;노희전
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.887-892
    • /
    • 2009
  • Biosafety research facilities require to verified about the facility and experimental environment, especially for level-3 and level-4 of biosafety research facilities verification is very important. In this paper, introduce verified procedures and present the methods and the results through a verified case of the biosafety level-3 research facilities.

  • PDF

Module level EMC verification method for replacement items in nuclear power plant

  • Hee-Taek Lim;Moon-Gi Min;Hyun-Ki Kim;Gwang-Hyun Lee;Chae-Hyun Yang
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2407-2418
    • /
    • 2023
  • Internal replaceable electronic module substitutions can impact EMC (ElectroMagnetic Compatibility) qualification testing and results if EMC testing is conducted at the cabinet level. The impact of component substitutions on EMC qualification results therefore should be evaluated. If a qualitative evaluation is not adequate to ensure that the modified product will not impact the cabinet level EMC qualification results, a new qualification testing should be conducted. Component level retesting should be conducted under electromagnetically equivalent conditions with the cabinet level test. This paper analyzes the propagation of conducted susceptibility test waveforms in a representative cabinet and evaluates the impact of component substitutions on cabinet level EMC qualification results according to the location of the replacement items. A guideline for a qualitative evaluation of the impact of component substitutions is described based on the propagation of the conducted susceptibility test waveforms. A module level test method is also described based on an analysis of the shielding effectiveness of the cabinet.

생물안전 3등급 연구시설의 구성 및 이용 (Composition and Use of Biosafety Level 3 Facility)

  • 김창환;허경행;이완걸;정성태
    • 한국군사과학기술학회지
    • /
    • 제18권3호
    • /
    • pp.335-342
    • /
    • 2015
  • Laboratory facilities for biology are designed as biosafety level 1, biosafety level 2, biosafety level 3, and biosafety level 4. Biosafety level designations are based on a composite of the design features, construction, containment facilities, equipment, practice and operation procedures required for working with agents from the various risk groups. Generally, biosafety level 3 means the facility that is appropriate for the experiments using pathogens which can cause serious diseases by aerosol transmission. The biosafety level assigned for the specific work to be done is driven by professional judgement based on a risk assessment, rather than by automatic assignment according to the particular risk group designation of the pathogenic agents to be used. In this paper, we introduced the biosafety level 3 facility operated in ADD(Agency for defense development). It contains the overview of facility, microbiological experiment, animal experiment, decontamination and waste disposal. Biosafety level 3 laboratory in ADD has served the vital role in the research of biological agents and antidote development.

조직의 연구보안 수준평가 모형 연구 (Research on the Level Evaluation Model of the Organization Research Security)

  • 나원철;장항배
    • 한국전자거래학회지
    • /
    • 제25권3호
    • /
    • pp.109-130
    • /
    • 2020
  • 최근 기술의 혁신을 위한 연구개발의 중요성이 커지고 있다. 연구개발의 급속한 발전은 다양한 긍정적 효과가 있지만, 동시에 정보 및 기술에 대한 유출 범죄를 가속화시키는 부정적 영향 또한 존재한다. 본 연구에서는 점차 심각해지는 연구개발 결과물 유출 사고를 대비하기 위해 조직 차원에서 이루어지는 연구개발 환경을 안전하게 보호할 수 있는 연구보안 수준측정 모형을 개발하였다. 먼저 국내외 연구개발 관련 보안정책들을 분석하고 종합하여, 연구보안 수준평가 항목 10개(연구보안 추진체계, 연구시설과 장비 보안, 전자정보 보안, 주요 연구정보 관리, 연구노트 관리, 지식재산권/특허 관리, 기술사업화 관리, 내부연구원 관리, 인가된 제3자 관리, 외부자 관리)를 전문가 인터뷰를 통해 도출하였다. 다음으로, 도출한 연구보안 수준평가 항목을 조직의 연구개발 환경에 다차원적 관점에서 적용 가능하도록 연구보안 수준평가 모형을 설계하였다. 마지막으로 모형에 대한 타당성을 검증하고, 실제 연구개발을 수행하는 조직을 대상으로 시범 적용하여 연구보안 수준을 평가해보았다. 본 연구에서 개발한 연구보안 수준평가 모형은 실제 연구개발을 수행하고 있는 조직 및 프로젝트의 보안 수준을 적절하게 측정하는 데 유용하게 활용될 수 있을 것으로 기대되고, 연구개발을 직접 수행하는 연구원들이 자체적으로 연구보안 체계를 수립하고 보안관리 대책을 마련하는 데 도움이 될 것이라 판단된다. 또한 연구개발을 수행하는 조직 차원의 보안성 향상뿐만 아니라 프로젝트 단위의 연구개발을 안전하게 수행함으로써, 연구개발 투자에 대한 안정적이고 효과적인 성과를 낼 수 있을 것이라 기대한다.

공항의 기대서비스 수준에 관한 연구: 유통서비스기관 평가결과의 효과를 중심으로 (A Study on the Customers' Service Expectation Level: The Effects of Distribution Service Excellence Awards for an Airport)

  • 천정이;박상범
    • 유통과학연구
    • /
    • 제16권11호
    • /
    • pp.47-56
    • /
    • 2018
  • Purpose - In this research, the expectation level of service of Incheon International Airport was investigated. Service expectation level is critical to the customers' satisfaction and should be managed. Regarding the expectation level of service, the concepts have been defined and introduced by some researchers including Zeithaml, Berry, and Parasuraman (1993). However, due to the difficulties of measuring the level, researches on the expectation level of service have been limited. The main reason of difficulties of measuring the effects is that desired service, adequate service, perceived service, predicted service which are the conceptual components of the expectation level of service are psychologically described concepts and thus are hard to set up standards and to measure numerically. All that one can discern is that desired service level is higher than adequate service level or perceived service level is lower than predicted service level under the certain conditions, etc. Research design, data, and methodology - In this research, the level of service and factors affecting the level are investigated using the case of an Airport. The main idea of research is to investigate whether a supposed factor that is alleged to affect the expected service level is working empirically. The supposed factor is service provider's promise to provide certain level of service to customers. Results - The research results can be summarized as follow. First, service provider's promise, in this case the Airport's Service Quality Award by Airports Council International which can be regarded as objective promise to provide the certain level of service to customers is turned out to be influential to factors affecting expectation level of service. Second, service provider's promise affects to move the customers' expectation level of service upward especially the service of delivering the necessary information to customers in the airport correctly and swiftly. Conclusions - The implications of the research results are, first, customers' expectation level of service in influenced by service provider's promise, second, airport's service award increases the level of customers' service level and as a result for the airport to meet the customers' expectation level of service more efforts should be made.

도시근린공원의 야간조도분포의 특성 (Characteristics of th Distribution of Night Illumination Level at Urban Neighborhood Parks)

  • 최연철;김진선
    • 한국조경학회지
    • /
    • 제28권4호
    • /
    • pp.66-74
    • /
    • 2000
  • The purpose of this study is to research and analyze the distribution of night illumination level at urban neighborhood parks and to show its characteristics. And this is used basic data ensuring safety and satisfying aesthetic and psychological desires of people who use urban neighborhood parks at night. To research and analyze the distribution of illumination level at urban neighborhood parks at night. To research and analyze the distribution of illumination level at urban neighborhood parks, I selected 8 urban neighborhood parks as the subject of research in this study, set the measuring standard of illumination level, and measured the illumination level by the measuring standard. The results of this study are as follows; 1. Currently, total average illumination level of urban neighborhood parks was lower than the minimum standard of illumination level I KS A 3011-1993. 2. Average illumination level of each place in urban neighborhood parks appeared variously from low level to high level. But this was lower than the minimum standard illumination level in KS A3011-1993 like total average illumination level. 3. The higher was total average illumination level of urban neighborhood parks, the more various was brightness of places. Although users' aesthetic and mental desire or behavioral aspect relate with safety cannot be found by only survey and analyses of illumination level, it is judged that first, illumination level of the standard of the lightness should be analyzed to find user's mental states and behaviors in external space at night. Therefore, it is considered that this study, which analyzed characteristics illumination level as basic data, has a significance. The study continuing for other illuminative environmental factors suitable in the place is required because the brightness of places may not be measured by only illumination level. And the proper illumination level in outdoor places should be showed in considering psychological and behavioral aspects of human as people may have their own sense of brightness.

  • PDF