• Title/Summary/Keyword: Research Facility

Search Result 4,470, Processing Time 0.031 seconds

The Analysis of Flow Circulation System for HANARO Flow Simulated Test Facility (하나로 유동모의 설비의 유체순환계통 해석)

  • Park, Yong-Chul
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.419-424
    • /
    • 2002
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality In February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. A flow simulation facility is being developed for the endurance test of reactivity control units for extended life times and the verification of structural integrity of those experimental facilities prior to loading in the HANARO. This test facility is composed of three major parts; a half-core structure assembly, flow circulation system and support system. The flow circulation system is composed of a circulation pump, a core flow pipe, a core bypass flow pipe and instruments. The system is to be filled with de-mineralized water and the flow should be met the design flow to simulate similar flow characteristics in the core channel of the half-core test facility to the HANARO. This paper, therefore, describes an analytical analysis to study the flow behavior of the system. The computational flow analysis has been performed for the verification of system pressure variation through the three-dimensional analysis program with standard k-$\epsilon$ turbulence model and for the verification of the structural piping integrity through the finite element method. The results of the analysis are satisfied the design requirements and structural piping integrity of flow circulation system.

  • PDF

An analysis on the inter and intra regional inequalities of rural area facility by a Gini Decomposition method (지니계수분해법을 이용한 농촌마을 시설물의 지역 격차 분석)

  • Park, Mee Jeong;Yun, Do Sic;Chin, Hyun Seung;Shin, Min Ji
    • Journal of Korean Society of Rural Planning
    • /
    • v.20 no.3
    • /
    • pp.11-20
    • /
    • 2014
  • This research aims to identify regional inequitable development through the analysis of facilities distribution pattern. This study describes the concepts underlying the application of the Gini's coefficient and decomposition method to measure the regional inequitable development in Sun-chang County, Jeonbuk Province, Korea. We used the facility data surveyed for three years, from 2010 to 2012 for facility distribution pattern that RDA surveyed. These data have been serviced on the web. The Lorenz Curve presents a graphical view of the inequitable facility distribution and the Gini's Coefficients quantifies the distribution pattern. And furthermore, Gini Decomposition represents intra regional inequalities. These applied techniques can describe how the local development affects other district and change regional inequalities.

Basic Study on the Arrangement Type Analysis of Closed School Facility According in Daegu Area -Focused on the Curriculum Changes- (폐교 활용을 위한 대구지역 폐교의 배치유형 분석에 관한 기초 연구 - 교육과정 변화를 중심으로 -)

  • Kim, Jae-Young;Lee, Jong-Kuk
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.12 no.2
    • /
    • pp.11-18
    • /
    • 2013
  • Since the Standard Design Guide in 1962 and "School Facility Facility Standard Regulation" established in 1969, the elementary school facility in Korea has been amended and complemented. The modern pilot school was started in 1991 and every elementary school facility has been designed based on the modern elementary school from 1994. At present, 8 out of 28 closed schools occurred in the downtown area in Daegu. One of them is located in rent and 7 are used by themselves. The rest 20 schools are located in Dalsung-gun and most of them have old buildings of straight plane shapes built in 1940s. The purpose of this basic study is to pursue the changing process of closed schools based on policy changes of curriculum and to seek the qualitative change when using closed schools. In addition, it is to prepare the using measures when the school close is occurred in the downtown area in the future by classifying and analyzing plane types according to their types.

Operation Techniques of Liquid Rocket Engine Combustor Ground Firing Test Facility (액체로켓엔진 연소기 지상연소시험설비 운영관리 기술)

  • Kang, Dong-Hyuk;Lim, Byoung-Jik;Moon, Il-Yoon;Seo, Seong-Hyeon;Han, Yeoung-Min;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.157-162
    • /
    • 2006
  • A Liquid Rocket Engine(LRE) ground firing test facility was built in Korea Aerospace Research Institute(KARI) in 2001 to develop the LRE for the first Korean liquid rocket, KSR-III. Around 170 tests were conducted since its establishment until recently by September 2006, and in the meantime, a considerable improvements were made in the capability. This paper describes the outline, conducted tests and operation techniques which have been accumulated through the operation of KARI LRE ground firing test facility.

  • PDF

Improving the Measurement Uncertainty of Altitude Test Facility for Gas Turbine Engines (가스터빈엔진 고공성능시험설비의 측정불확도 개선)

  • Lee, Dae-Sung;Yang, In-Young;Jun, Yong-Min;Kim, Chun-Taek;Yang, Soo-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.11
    • /
    • pp.1496-1502
    • /
    • 2002
  • An Altitude Engine Test Facility(AETF) was built at the Korea Aerospace Research Institute in October 1999 and has been being operated for altitude testing of gas turbine engines of 3,000 Ibf class or less. The AETF has been calibrated using several engines such as J69 of Teledyne Co. as a facility checkout engine. Uncertainty analyses on the air flow rate and thrust were performed using the test results, according to ASME PTC 19.1-1998. Several modifications on the facility and test method were made in order to improve the measurement uncertainty to a satisfactory level over the whole operating envelop. Spatial distributions of pressure and temperature were measured, sensors were substituted by more accurate ones, inlet duct was modified to refine the flow quality, and pressure control logic was revised to remove the cell pressure fluctuation. As a result, the uncertainty of the air flow measurement was improved by 0.1% over all the test conditions, and the net thrust measurement by up to 3%. The improved measurement uncertainties of air flow and thrust are 0.68~O.73% and 0.4~1.3%, respectively.

An Optimization Algorithm for the Two-Echelon Capacitated Facility Location Problem (용량 제약이 있는 이계층 설비 입지선정 문제의 최적화 해법)

  • Kim Eun Jeong;Gang Dong Hwan;Lee Gyeong Sik;Park Seong Su
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2003.05a
    • /
    • pp.137-144
    • /
    • 2003
  • We consider Two-echelon Single source Capacitated Facility Location Problem (TSCFLP). TSCFLP is a variant or Capacitated Facility Location Problem (CFLP). which has been an important issue in boa academic and industrial aspects. Given a set or possible facility locations in two echelons (warehouse / plant), a set or customers, TSCFLP is a decision problem to find a set or facility locations to open and to determine an allocation schedule that satisfies the demands or the customers and the capacity constraints or the facilities, while minimizing the overall cost. It ran be shown that TSCFLP Is strongly NP-hard For TSCFLf, few algorithms are known. which are heuristics. We propose a disaggregated version or the standard mixed integer programming formulation or TSCFLP We also provide a class or valid Inequalities Branch-and-price algorithm with rutting plane method Is used to find an optimal solution Efficient branching strategy compatible with subproblem optimization problems Is also provided. We report computational results or tests on 15 randomly generated instances.

  • PDF

The Effect of Early Educator's Psychological Exhaustion and Happiness on Children's Adapting Ability in Early Education Settings (유아교사의 심리적 소진과 행복감이 유아의 교육기관 적응능력에 미치는 영향)

  • Moon, Eunyoung;Oh, Sunjin
    • Korean Journal of Childcare and Education
    • /
    • v.12 no.3
    • /
    • pp.177-195
    • /
    • 2016
  • The purpose of this study was to investigate the effect of early educator's psychological exhaustion and happiness on adapting ability of children in early education settings. Two hundred ten early educators and six hundred thirty children were selected as subjects of this study and were requested to participate in a survey. The results of this study were as follows: First, as a result of analyzing the relationship between early educator's psychological exhaustion and happiness as well as children's adaptability on education facility, higher psychological exhaustion and lower happiness were related to lower children's adaptability on education facility. Second, as a result of comparing comparative impact that psychological exhaustion and happiness has on children's adaptability on education facility, psychological exhaustion of the teacher impacts negatively on children's adaptability on education facility and happiness of the teacher did not significantly impact children's adaptability on education facility. This research is expected to be used as foundational data that helps to recognize the importance of psychological exhaustion and happiness of the teacher and could be used to develop various programs that support teachers to recover from burnout and to increase happiness.

Investigation on Ventilation Mmethod and Recognition of Users in Healthcare Facilities of KOREA (국내 의료기관의 환기설비 운영실태 및 인식 조사)

  • Jo, Seongmin;Sung, Minki
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.24 no.2
    • /
    • pp.7-14
    • /
    • 2018
  • Purpose: The outbreak of Middle East Respiratory Syndrome(MERS) in KOREA has brought up the demands for ventilation guideline and regulations for healthcare facilities since most of the infection was spreaded inside healthcare facility. Currently KOREA has no ventilation guideline or regulations covering entire section of healthcare facility. The purpose of this study is to investigate current ventilation methods in KOREA healthcare facilities to in future, propose ventilation guideline. Methods: Research of foreign counties ventilation guideline and regulation for healthcare facilities were conducted for reference. Field investigation with survey of 21 healthcare were conducted to identify the ventilation system and operating methods. Additionally survey for healthcare workers were conducted to observe the recognition related to ventilation system in healthcare facility. Results: The result showed that most of foreign countries ventilation guideline and regulation suggests similar items to reduce the spread of infection and maintain good indoor air quality. The investigation results indicated that fixed guideline for ventilation in healthcare facility were required due to different ventilation operating methods. Survey result of healthcare workers has told us that ventilation guideline and regulation is needed to prevent further infection. Implications: Absence of ventilation guideline and regulations for healthcare facility in KOREA is an urgent issue.

Development of 1/60th Scale Moving Model Rig Using the Compressed Air Launcher and One-Wire Guidance System of Train Model (압축공기 발사기에 단선 와이어 유도방식을 적용한 1/60축척 터널주행 열차모형 시험기 개발에 대한 연구)

  • Kim, Dong-Hyeon;O, Il-Geun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.5
    • /
    • pp.634-644
    • /
    • 2001
  • The test facility of a 1/60-scale model for train-tunnel systems has been recently developed to investigate the effects of tunnel portal shapes, hood shapes and air-shafts for reducing the micro-pressure waves radiating towards the surroundings from the tunnel exit. The present test rig has been advanced from a 1/70-scale facility at NLR in Netherlands. The NLR test rig has the two-wise guidance system that needs two ears attached on the external surface of a model train nose. Therefore, their train models have irregular nose shapes. The main characteristics of the present facility are that the train model is guided by only one wire from the compressed air launcher to the absorber parts of test facility and the wire guidance hole is located at the axial center of a train model. In the present test rig, after a train model is launched, the air jet from the launcher does not enter the tunnel model. Experimental results were compared with numerical predictions to prove the performance of the test facility.

A Study on BIM-based Reference Model for Effective Urban Facility Management (효과적인 도시시설물 관리를 위한 BIM기반 참조 모델 개발)

  • Kang, Tae-Wook;Youn, Jun-Hee;Kim, Jang-Wook;Choi, Hyun-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1786-1794
    • /
    • 2014
  • The purpose of this study is to suggest BIM-based Reference Model(RM) for Urban Facility Management(UFM) System development efficiently. The urban facility management's objective is to take the user convenience and safety from checking the facility to maintain it's function. Recently, to manage the facilities effectively, the BIM technology is being applied to it. In this study, the research trend related to the UFM system is surveyed and analyzed to develop the BIM-based UFM RM. After developing the RM component and process, the BIM-based UFM RM is proposed.