• Title/Summary/Keyword: Repetition rate

Search Result 434, Processing Time 0.024 seconds

Genotoxicity Study of GST Extract (GST 추출물의 유전독성평가)

  • Lee, Chul Wha;Han, Jong Min;Lee, Mi Young;Jung, In Chul;Jin, Mirim;Kim, Seung Hyung;Park, Yang Chun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.28 no.6
    • /
    • pp.621-629
    • /
    • 2014
  • This study aimed to evaluate the genotoxicity of GST (Gamisasangja-tang). For examining genotoxicity, we carried out bacterial reverse mutation assay, chromosome aberration assay, micronucleus induction test according to OECD guidelines. Bacterial reverse mutation assay: In GST treating group, regardless of existence S9 mix, revertant colonies counts appeared to be less than twice of negative control group and dose dependent increase. In positive control group, revertant colonies counts were shown to be more than twice of negative control croup. Chromosome aberration assay: All cell line showed repetition rate of abnormal chromosome aberration less than 5%, regardless of treating time, existence of S9 mix, and no significant change ($p{\succeq}0.05$) compared with negative control group. Micronucleus induction test: Micronucleated polychromatic erythrocytes (MNPCE) repetition rate of Polychromatic erythrocytes (PCE) showed no significant changes compared with negative control group ($p{\succeq}0.05$). PCE portion of total erythrocytes also showed no significant changes ($p{\succeq}0.05$). Our results showed that GST didn't induce any genotoxicity.

PD Signal Time-Frequency Map and PRPD Pattern Analysis of Nano SiO2 Modified Palm Oil for Transformer Insulation Applications

  • Arvind Shriram, R.K.;Chandrasekar, S.;Karthik, B.
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.902-910
    • /
    • 2018
  • In recent times, development of nanofluid insulation for power transformers is a hot research topic. Many researchers reported the enhancement in dielectric characteristics of nano modified mineral oils. Considering the drawbacks of petroleum based mineral oil, it is necessary to understand the dielectric characteristics of nanofluids developed with natural ester based oils. Palm oil has better insulation characteristics comparable to mineral oil. However very few research reports is available in the area of nanofluids based on palm oil. Partial discharge (PD) is one of the major sources of insulation performance degradation of transformer oil. It is essential to understand the partial discharge(PD) characteristics by collecting huge data base of PD performance of nano modified palm oil which will increase its confidence level for power transformer application. Knowing these facts, in the present work, certain laboratory experiments have been performed on PD characteristics of nano $SiO_2$ modified palm oil at different electrode configurations. Influence of concentration of nano filler material on the PD characteristics is also studied. Partial discharge inception voltage, Phase resolved partial discharge (PRPD) pattern, PD signal time-frequency domain characteristics, PD signal equivalent timelength-bandwidth mapping, Weibull distribution statistical parameters of PRPD pattern, skewness, repetition rate and phase angle variations are evaluated at different test conditions. From the results of the experiments conducted, we came to understand that PD performance of palm oil is considerably enhanced with the addition of $nano-SiO_2$ filler at 0.01%wt and 0.05%wt concentration. Significant reduction in PD inception voltage, repetition rate, Weibull shape parameter and PD magnitude are noticed with addition of $SiO_2$ nanofillers in palm oil. These results will be useful for recommending nano modified palm oil for power transformer applications.

A Simple Metric for Assessing the Severity of Partial Discharge Activity Based on Time-Sequence-Analysis-Discharge Level Patterns

  • Stewart Brian G;Yang Lily;Judd Martin D;Reid Alistair;Fouracre Richard A
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.6
    • /
    • pp.313-318
    • /
    • 2006
  • This paper introduces a partial discharge (PD) severity metric, S, based on the evaluation of time-sequence PD data capture and resulting Time-Sequence-Analysis Discharge (TSAD) level distributions. Basically based on an IEC60270 measurement technique, each PD event is time stamped and the discharge level noted. By evaluating the time differences between a previous and subsequent discharge, a 3D plot of time-sequence activity and discharge levels can be produced. From these parameters a measurement of severity, which takes into account dynamic or instantaneous variations in both the time of occurrence and the level of discharge, rather than using standard repetition rate techniques, can be formulated. The idea is to provide a measure of the severity of PD activity for potentially measuring the state of insulation within an item of plant. This severity measure is evaluated for a simple point-plane geometry in $SF_{6}$ as a function of gap distance and applied high voltage. The results show that as the partial discharge activity increases, the severity measure also increases. The importance of future investigations, quantifications and evaluations of the robustness, sensitivity and importance of such a severity measurement, as well as comparing it with typical repetition rate assessment techniques, and other monitoring techniques, are also very briefly discussed.

Changes in Total Work, Total Work Ratio, Heart Rate, and Blood Lactate during 75% 1-RM Bench Press Exercise

  • Kim, Ki Hong;Kim, Byung Kwan
    • Medical Lasers
    • /
    • v.10 no.3
    • /
    • pp.153-160
    • /
    • 2021
  • Background and Objectives This study was conducted to investigate the change of total work and total work ratio for each set, peak heart rate during exercise, and blood lactate for each set during the 5-set bench press exercise at 75% one repetition maximum test (1-RM). Materials and Methods Seven men in their 20s with more than 6 months of experience doing resistance exercises were selected as subjects, and their 1-RM bench press was measured two weeks before the experiment and 75% 1-RM was measured one week before the experiment. In this study, total work was measured for each set, and heart rate was measured during rest and set-by-set exercise. Blood lactate was measured during rest time after each set. The raw data were analyzed by repeated one-way ANOVA. Results Total work and total work ratio decreased from 1 set to 4 sets (p < .05), p < .001), heart rate increased from stable at the start of exercise (p < .001) and decreased between 3 sets and 4 sets (p < .05). Blood lactate increased continuously up to 2 sets (p < .001, p < .01). Conclusion In conclusion, total work and heart rate decreased with muscle fatigue during exercise, and blood lactate continuously increased. The results of this study are expected to be useful references for constructing resistance exercise programs in the future.

The Effect of Water Depth and Exercise Speed on Physiological Responses Immediately After Aquatic Squat Exercise

  • Gyu-sun, Moon
    • International journal of advanced smart convergence
    • /
    • v.13 no.1
    • /
    • pp.185-193
    • /
    • 2024
  • This study aimed to investigate the immediate physiological responses, including heart rate, blood pressure, and rate pressure product (RPP), following squat exercises performed at three water depths (ground, knee depth, waist depth) and two speed conditions (60bpm speed, Max speed). The participants consisted of 10 men in their 20s with over 6 months of resistance exercise experience. For the 60bpm speed squats, participants performed 30 repetitions in 1 minute at a rate of 2 seconds per repetition, while for Max speed squats, they performed at Max speed without a set limit on the number of repetitions for 1 minute. All experiments were conducted with a random assignment. The study results showed that immediately after the aquatic squat exercise, the average heart rate, blood pressure, and cardiac load were higher in the order of knee depth, ground level, and waist depth at both 60bpm speed and Max Speed. At 60bpm speed, the heart rate was higher in the order of ground level, knee depth, and waist depth. Overall, exercise in an aquatic environment was considered to impose relatively lower physical burden compared to land-based exercise. Therefore, it is suggested that depending on individual fitness levels and exercise goals, appropriately combining aquatic exercise, which imposes lower immediate physiological burden, and land-based exercise may lead to safer and more effective exercise methods.

The Influence of perceptual load on target identification and negative repetition effect in post-cueing forced choice task (순간 노출되는 표적의 식별과 부적 반복효과에 지각부하가 미치는 영향)

  • Kim, Inik;Park, ChangHo
    • Korean Journal of Cognitive Science
    • /
    • v.33 no.1
    • /
    • pp.1-22
    • /
    • 2022
  • Lavie's perceptual load theory (Lavie, 1995) proposes that the influence of distractors would be blocked as the load gets higher. Studies of perceptual load have usually adopted the flanker task, developed by Eriksen and Eriksen (1974), which measures reaction time on the target flanked by distractors. In the post-cueing forced task, participants should report the identity of the target cued later, and negative repetition effect (NRE) has often been observed. NRE means the effect that the accuracy of identification is worse when the target is flanked by the same nontargets than when flanked by different nontargets. This study has tried to check whether perceptual load has an effect on identification rate and NRE. Experiment 1 manipulated the similarity between targets and a distractor, and observed a tendency of NRE, but not the effect of perceptual load. Experiment 2 used 4, 2 (in two kinds of diagonal arrangement), or none distractors of the same identity to burden more perceptual load. NRE was significant and perceptual load showed significance but not a linear trend. Experiment 3 checked again whether NRE would be varied according to two levels of perceptual load strengthened by positional variability of load stimuli, but did not find the effect of perceptual load. It is concluded that perceptual load might have a limited effect on the early stage of perceptual processing due to divided attentional processing of the targets briefly exposed. Implications of this study were discussed.

Sputtering Technique of Magnesium Oxide Thin Film for Plasma Display Panel Applications

  • Choi Young-Wook;Kim Jee-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.110-113
    • /
    • 2006
  • A high rate deposition sputtering process of magnesium oxide thin film in oxide mode has been developed using a 20 kW unipolar pulsed power supply. The power supply was operated at a maximum constant voltage of 500 V and a constant current of 40 A. The pulse repetition rate and the duty were changed in the ranges of $10\sim50$ kHz and $10\sim60%$, respectively. The deposition rate increased with rising incident power to the target. Maximum incident power to the magnesium target was obtained by the control of frequency, duty and current. The deposition rate of a moving state was 9 nm m/min at the average power of 1.5 kW. This result shows higher deposition rate than any other previous work involving reactive sputtering in oxide mode. The thickness uniformities over the entire substrate area of $982mm{\times}563mm$ were observed at the processing pressure of $2.8\sim9.5$ mTorr. The thickness distribution was improved at lower pressure. This technique is proposed for application to a high through-put sputtering system for plasma display panels.

Design and Performance Analysis of 100 Mbps M-ary PPM/TH Ultra-Wideband Communication Systems in the AWGN Channels (AWGN 채널에서 100Mbps급 M-ary PPM/TH 초광대역 통신 시스템의 설계 및 성능 분석)

  • 문용규;이양선;강희조;양승인
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.2
    • /
    • pp.139-147
    • /
    • 2003
  • In this paper we proposed system parameter values of M-ary PPM/TH(Pulse Position Modulation/Time Hopping) ultra-wideband systems having data rate of 100 Mbps for the frequency band, which is allocated by Federal Communications Commission(FCC). We also analyzed performance of the proposed system in the AWGN channels. According to the results of performance analysis, It is observed that available pulse duration is very limitative for this system. In case of constant data rate, if M and the pulse repetition numbers are increased, then the system performance is improved and the user number is decreased.

Optimized Channel Coding of Control Channels for Mobile Packet Communication

  • Song, Young-Joon
    • Journal of electromagnetic engineering and science
    • /
    • v.3 no.1
    • /
    • pp.50-56
    • /
    • 2003
  • This paper proposes a coding scheme of control channel for mobile packet communication to maximize the minimum Hamming distance, which is based on shifting of basis vectors of Reed Muller code with optimized dynamic puncturing and/or(partial) sequence repetition. Since the maximum likelihood decoding can be performed using the extremely simple FHT(Fast Hadamard Transformation), it is suitable for real time optimum decoding of control channel information with very little complexity. We show applications of the proposed coding method to TFCI(Transport Format Combination Indicator) code in split and normal modes of 3GPP W-CDMA system. We also discuss how this method can reduce rate indication error over AWGN(Additive White Gaussian Noise) as well as fading channels when the proposed coding scheme is applied to 1xEV-DV system of $3^{rd}$TEX> generation partnership project 2(3GPP2) to indicate the data rate transmitted on the reverse traffic channel by a Mobile Station(MS).

Development of high power impulse magnetron sputtering (HiPIMS) techniques

  • Lee, Jyh-Wei
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.3-32
    • /
    • 2016
  • High power impulse magnetron sputtering (HiPIMS) technique has been developed for more than 15 years. It is characterized by its ultra-high peak current and peak power density to obtain unique thin film properties, such as high hardness, good adhesion and tribological performance. However, its low deposition rate makes it hard to be applied in industries. In this work, the development of HiPIMS system and integration of radio frequency (RF) or mid-frequency (MF) power supplies were introduced. Effects of duty cycle and repetition frequency on the microstructure, mechanical property, optical and electrical properties of some binary, ternary and quarternary nitride coatings and oxide thin films were discussed. It can be observed that the deposition rate was effectively increased by the superimposed HiPIMS with RF or MF power. High hardness, good adhesion and sufficient wear resistance can be obtained through a proper adjustment of processing parameters of HiPIMS power system.

  • PDF