• Title/Summary/Keyword: Removal of dental implant

Search Result 156, Processing Time 0.03 seconds

Comparison of removal torque between prefabricated and customized abutment screw (기성품과 맞춤형 임플란트 지대주 나사의 풀림 토크 비교)

  • Jamiyandorj, Otgonbold;Kim, Jee-Hwan;Kim, Mu-Seong;Park, Young-Bum;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.243-248
    • /
    • 2012
  • Purpose: The purpose of this study is to compare the removal torque between prefabricated and customized implant abutment screw. Materials and methods: Three types of implant system (Osstem, Astra, Zimmer) were used. For each system, prefabricated abutment screw (control group) and customized abutment screw (test group) were used to connect the fixture and the abutment (n = 6). Digital torque gauze was used to control the tightening torque and the screws were tightened under each manufacturer's recommendation. 10 minutes after the connection the same tightening torque was applied, and 5 minutes after the second connection, the removal torque was measured. This procedure was repeated 10 times. In the cyclic loading test, 10 minutes after the first connection to the 6 groups (n = 3), the same tightening torque was applied, and a total of 1,000,000 time loading was applied at 30 degree angle to long axis with 50 N load. Repeated measures of ANOVA test (${\alpha}$=.05) was used as statistics to evaluate the effect of repeated loading number on the removal torque. Independent t-test was used to evaluate the difference in removal torque after cyclic loading. Results: The removal torque significantly decreased as the number of loading repetition increased (P<.05). In the 10 time repetition test, there was no significant difference between the prefabricated and customized implant abutment screw of the 3 implant system (P<.05). Also in the cyclic loading test, there was no significant difference between the prefabricated and customized implant abutment screw of the 3 implant system (P<.05). Conclusion: Within the limitation of this study, there was no significant difference in the removal torque between the prefabricated abutment screw and customized abutment screws.

Joint stability of internal conical connection abutments with or without hexagon indexes: an in vitro study (내부연결 원추형 임플란트의 육각구조의 유무에 따른 연결부 안정성: 실험적 연구)

  • Lee, Sang-Woon;Cha, Min-Sang;Lee, Ji-Hye;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.95-103
    • /
    • 2020
  • Purpose: The purpose of this study was to compare the axial displacement of the hexagonal and conical abutment in internal conical connection implant after screw tightening and cyclic loading. Materials and Methods: Internal conical connection implants were divided into two groups (n = 10): group HEX, hexagonal abutment; and group CON, conical 2-piece abutments. The axial displacement and removal torque values were measured after 30 Ncm torque tightening and 250N loading test of 100,000 cycles. The Student t test with 5% significance level was used to evaluate the data. Results: HEX group demonstrated significantly higher axial displacement values after 30 Ncm tightening in comparison to the CON group (P < 0.05). No significant difference was found in axial displacement after cyclic loading (P = 0.052). Removal torque loss before and after the cyclic loading both revealed no significant difference between groups (P = 0.057 and P = 0.138). Removal torque value decreased after cyclic loading in both groups (P < 0.05). Conclusion: Overall, both abutment with or without hexagon index presented similar biomechanical performance except HEX group demonstrated significantly more axial displacement after applying tightening torque.

Displacement of dental implants into the focal osteoporotic bone marrow defect: a report of three cases

  • Lee, Sang-Chil;Jeong, Chang-Hwa;Im, Ho-Yong;Kim, Seong-Young;Ryu, Jae-Young;Yeom, Hak-Yeol;Kim, Hyeon-Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.2
    • /
    • pp.94-99
    • /
    • 2013
  • Focal osteoporotic bone marrow defect (FOBMD) is a radiolucent area corresponding to the presence of hematopoietic tissue rarely found in the jaws. FOBMD is most commonly located in the mandibular edentulous posterior area of a middle-aged female. From November 2011 to November 2012, we experienced three cases involving removal of implants that had accidentally fallen into the FOBMD area. All patients happened to be female, with a mean age of 54 years (range: 51-60 years). One case involved hypoesthesia of the lower lip and chin, while two cases healed without any complication. Displacement of an implant into the FOBMD area is an unusual event, which occurs rarely during placement of a dental fixture. The purpose of this study was to report on three cases of FOBMD and to provide a review of related literature.

A CASE REPORT OF IMPLANT PLACEMENT IN DISTRACTION-AUGMENTED ALVEOLAR BONE OF THE MANDIBLE (하악골 결손부의 치조골 신장술을 이용한 임플란트 식립 증례보고)

  • Ryu, Hyun-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.4
    • /
    • pp.325-329
    • /
    • 2009
  • Objective : This is to report the effectiveness of intraoral distraction osteogenesis, iliac bone graft for alveolar augmentation in the extremely atrophied alveolar defects after infected allobone grafted area. Subjects and Methods : Anterior segmental osteotomy was performed and the trans-oral alveolar distractors (Martin, Germany) were applied in patient with the severe acquired anterior mandibular and mandibular defect after ameloblastoma enucleation. Iliac bone grafts were performed in defect sites and distraction osteogenesis were treated. After latent period for 1 week, the osteomized alveolar segments were distracted by 0.75 mm a day (0.25 mm/1 turn) for 10 days The consolidation period was about 12 weeks. Thereafter, 2 titanium threaded implants were simultaneously installed with removal of distractor. For oral rehabilitiation, The implants were installed in maxilla, mandible. It was tested with clinically and radiographically. Results : Amounts of acquired alveolar bone were 10 mm with the increased width of the ridge crests and soft tissue expansion. Dental implants installated on the augmented alveolar ridges in 12 weeks after distraction were confirmed as in good osseointegration and in good function without any complications. Conclusion : Intraoral distraction osteogenesis can be a good option for alveolar ridge augmentation of the severely atrophied ridges and soft-tissue defects.

Resin bonded fixed prosthesis for single tooth restoration: A case report (단일치 상실을 레진 접착 고정성 보철물로 수복한 증례)

  • Kim, Eunkyung;Lee, Jonghyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.325-330
    • /
    • 2017
  • In the case of single tooth replacement, a fixed prosthesis or a dental implant is the treatment option commonly selected as first choice. However, any amount of sound tooth structure should be removed to prepare the abutment teeth for full coverage retainer. The adjacent tooth damage can be avoided placing a dental implant. However, depending on the patient's oral condition and any other circumstances, it may be impossible or delayed. In this case resin bonded fixed partial denture was selected as an alternative that can restore single tooth loss without much tooth structure removal to the young patients and the patients with gingival recession. We report these patients were satisfied with esthetic and function.

The Evaluation of the atomic composition and the surface roughness of Titanium Implants following Various Laser treatment with air-powder abrasive (레이저 처리후 임프란트 표면 변화에 관한 연구)

  • Kim, Tae-Jung;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.3
    • /
    • pp.615-630
    • /
    • 2002
  • Various long-term studies have shown that titanium implants as abutments for different types of prostheses have become a predictable adjunct in the treatment of partially or fully edentulous patients. The continuous exposure of dental implants to the oral cavity with all its possible contaminants creates a problem. A lack of attachment, together with or caused by bacterial insult, may lead to peri-implantitis and eventual implant failure. Removal of plaque and calculus deposits from dental titanium implants with procedures and instruments originally made for cleaning natural teeth or roots may cause major alterations of the delicate titanium oxide layer. Therefore, the ultimate goal of a cleaning procedure should be to remove the contaminants and restore the elemental composition of the surface oxide without changing the surface topography and harming the surrounding tissues. Among many chemical and mechanical procedure, air-powder abrasive have been known to be most effective for cleaning and detoxification of implant surface. Most of published studies show that the dental laser may be useful in the treatment of pen-implantitis. $CO_2$ laser and Soft Diode laser were reported to kill bacteria of implant surface. The purpose of this study was to obtain clinical guide by application these laser to implant surface by means of Non-contact Surface profilometer and X-ray photoelectron spectroscopy(XPS) with respect to surface roughness and atomic composition. Experimental rough pure titanium cylinder models were fabricated. All of them was air-powder abraded for 1 minute and they were named control group. And then, the $CO_2$ laser treatment under dry, hydrogen peroxide and wet condition or the Soft Diode laser treatment under Toluidine blue O solution condition was performed on the each of the control models. The results were as follows: 1. Mean Surface roughness(Ra) of all experimental group was decreased than that of control group. But it wasn't statistically significant. 2. XPS analysis showed that in the all experimental group, titanium level were decreased, when compared with control group. 3. XPS analysis showed that the level of oxygen in the experimental group 1, 3($CO_2$ laser treatment under dry and wet condition) and 4(Soft Diode laser was used under toluidine blue O solution) were decreased, when compared with control group. 4. XPS analysis showed that the atomic composition of experimental group 2($CO_2$ laser treatment under hydrogen peroxide) was to be closest to that of control group than the other experimental group. From the result of this study, this may be concluded. Following air-powder abrasive treatment, the $CO_2$ laser in safe d-pulse mode and the Soft Diode laser used with photosensitizer would not change rough titanium surface roughness. Especially, $CO_2$ laser treatment under hydrogen peroxide gave the best results from elemental points of view, and can be used safely to treat peri-implantitis.

Biological effects of a root conditioning agent for dentin surface modification in vitro

  • Lee, Jue-Yeon;Seol, Yang-Jo;Park, Jang-Ryul;Park, Yoon-Jeong;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.6
    • /
    • pp.257-264
    • /
    • 2010
  • Purpose: Connective tissue reattachment to periodontally damaged root surfaces is one of the most important goals of periodontal therapy. The aim of this study was to develop a root conditioning agent that can demineralize and detoxify the infected root surface. Methods: Dentin slices obtained from human teeth were treated with a novel root planing agent for 2 minutes and then washed with phosphate-buffered saline. Smear layer removal and type I collagen exposure were observed by scanning electron microscopy (SEM) and type I collagen immunostaining, respectively. Cell attachment and lipopolysaccharides (LPS) removal demonstrated the efficiency of the root conditioning agent. Results: SEM revealed that the smear layer was entirely removed and the dentinal tubules were opened by the experimental gel. Type I collagen was exposed on the surfaces of the dentin slices treated by the experimental gel, which were compared with dentin treated with other root planing agents. Dentin slices treated with the experimental gel showed the highest number of attached fibroblasts and flattened cell morphology. The agar diffusion assay demonstrated that the experimental gel also has effective antimicrobial activity. Escherichia coli LPS were effectively removed from well plates by the experimental gel. Conclusions: These results demonstrated that this experimental gel is a useful tool for root conditioning of infected root surfaces and can also be applied for detoxification of ailing implant surface threads.

Comparative analysis of accuracy of how to use the implant torque controllers (사용 방법에 따른 임플란트 토크 조절기의 정확성 비교 분석 연구)

  • Cho, Lee-Ra;Park, Chan-Jin;Huh, Yoon-Hyuk;Lee, Ji-Hye;Kim, Dae-Gon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.300-306
    • /
    • 2013
  • Purpose: This study was to evaluate the accuracy of how to use the Mechanical Torque-Limiting Devices. Materials and methods: Three different implant manufacturers (Dentium, Osstem, Shinhung) were prepared for each two implant torque controllers. Divided into two groups depending on the method used for removal torque was measured. Repeated measures of ANOVA test (${\alpha}=.05$) was used as statistics to evaluate the effect of repeated loading number on the removal torque. Independent t-test was used to evaluate the difference in removal torque of two groups. Results: The removal torque significantly decreased as the number of loading repetition increased (P<.05). There was significant difference between two groups. Conclusion: Loosen the handle part of the implant torque controllers spring resilience to recover one group compared to the group that did not, showed a little more closed to the reference value.

The plaque-removing efficacy of a single-tufted brush on the lingual and buccal surfaces of the molars

  • Lee, Dong-Won;Moon, Ik-Sang
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.3
    • /
    • pp.131-134
    • /
    • 2011
  • Purpose: To test the plaque-removal efficacy of a single-tufted toothbrush on the posterior molars compared with a flat-trimmed toothbrush. Methods: Forty-nine subjects were selected. Professional instruction and written brushing instructions were given. After thorough supra-gingival scaling and polishing, all subjects were asked to abstain from oral hygiene procedures for 24 hours prior to the first experiment. The subjects were randomized to a treatment sequence. The modified Quigley and Hein plaque index was recorded pre- and post-tooth brushing, at 6 surfaces of the posterior molars. After a wash-out period, all the remaining plaque was removed professionally. Twenty-four hours of brushing abstinence was again performed. The plaque index was recorded pre- and post-tooth brushing after the subjects were given the second toothbrush in the cross-over sequence. Results: The percentage reductions in plaque scores achieved with the single-tufted brushes were significantly higher than those of the flat-trimmed brush at the maxillary buccal interproximal, marginal and mandibular lingual interproximal site. The other locations showed no significant difference. Conclusions: The results of the present study implied that the single-tufted brush could be an effective tool for the removal of plaque at some, but not all, sites of the posterior molars.

Mechanical Properties and Cross-sectional Surface Evaluation of Dental Ceramic Abutment (치과용 세라믹 임플란트 지대주의 기계적 특성 및 절단면 평가)

  • Hwang, Jun Ho;Kwon, Sung-Min;Choi, Sung Gi;Sung, Mi Ae;Lee, Kyu-Bok
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.5
    • /
    • pp.309-315
    • /
    • 2018
  • The purpose of this study is to assess the mechanical properties of the ceramic abutment with washer. In this study, ceramic abutment were used, tested with $30^{\circ}$ compression load, shear fatigue, adaptation accuracy test(rotation angle, contact interval), removal torque force test, torsional breaking force test. The $30^{\circ}$ compression load was 729 N, the shear fatigue load was 275 N, adaptation accuracy test of rotation angle was within $3^{\circ}$, contact interval within $10{\mu}m$, and removal torque force test value is $18.88N{\cdot}cm$, torsional breaking force test value is $35.52N{\cdot}cm$. Ceramic abutment with a washer fitted have sufficient mechanical strength and may be substituted for titanium abutment.