• Title/Summary/Keyword: Removal Amount

Search Result 1,442, Processing Time 0.031 seconds

SEM EVALUATION OF THE PREPARED ROOT CANALS BY HAND AND Ni-Ti ROTARY ROOT CANAL INSTRUMENTS (Hand & rotary root canal instrument의 근관내 삭제 형태에 관한 전자현미경적 비교)

  • Oh, Tae-Seok;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.477-486
    • /
    • 1998
  • Recently the development of rotary instrument makes it possible that in root canal treatment operator saves much more time, maintans original curved canal shape and easily prepares continuous tapered root canal. The purpose of this experiment was to examine the smoothness of the internal surface of prepared root canal and the effectiveness of debridement in prepared root canal by SEM for the comparison of hand and Ni-Ti rotary instrument. 25 extracted human teeth were access opened and # 10 K-type file was introduced into canal until it was appeared at the apical foramen. The working length was established by subtracting 0.5mm from this measurement. Group 1. The root canal preparation was done to # 30 with working length and then step-back until # 45 with K-Flexofile (Maillefer, Swiss). Group 2. Root canal preparation was done by Naviflex Ni-Ti file (Brasseler, USA) as the same technique with group 1. Group 3. Canal was prepared by Profile .04 (Maillefer, Swiss) taper until #30. Group 4. With use of Quantec (Tycom, USA) root canal was prepared from file number 1 to 8. In group 1 and 2, the root canal irrigant was NaOCl and the other groups, NaOCl and RC-prep (Premine Dental Products, USA) was used. The prepared teeth were notched with high-speed bur as bucco-lingual direction and fractured with chisel and mallet, then examined with SEM. Group 1 showed smooth internal surface. There were scratches mainly to the axial direction. Group 2 showed similar characteristics to those in group 1. Group 3 showed more smoother and linear cutting surface with bised scratches. Group 4 has the almost same characteristics group 3 and there was no difference in the file design. Ni-Ti rotary root canal instrument prepare the dentinal wall more smoother than hand instrument. The effectiveness of debridement was not fully affected by file design. The isthmus area and accessory canals of the root canal system were not prepared in any group. According to the result, hand and rotary type instrumentation techniques were effective in removal of major amount of tissue from root canal but it was not complete. In the direction of cutting movement there was difference between them.

  • PDF

A study on the smoke control performance of the damper exhaust system at FCEV fire in tunnel for small vehicles (소형차 전용터널 내 수소연료전지차 화재시 집중배기방식의 제연성능에 관한 연구)

  • Hong, Seo-Hee;Baek, Doo-San
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.745-756
    • /
    • 2022
  • The road tunnel is a semi-closed space that is blocked on all sides except the entrance and exit, and in the event of a fire, the smoke of the fire spreads longitudinally due to heat buoyancy caused by the fire and air currents that always exist in the tunnel. To solve this problem, smoke removal facilities are installed in road tunnels to secure a safe evacuation environment by controlling the direction of movement of smoke or directly smoking at fire points. In urban areas, the service level of urban roads decreases due to the increase in traffic due to the increase in population, and as a solution, the construction of underground roads in urban areas is increasing. When a fire occurs during hydrogen leakage through TPRD of a hydrogen fuel cell vehicle (FCEV), the fire intensity depends on the amount of leakage, and the maximum fire intensity depends on the orifice diameter of the TPRD. Considering the TPRD orifice diameter of 1.8 mm, this study analyzed the diffusion distance of fire smoke according to the wind speed of the roadway and the opening interval of the large exhaust port when the maximum fire intensity was 15 MW. As a result, it was analyzed that air flow in the tunnel could be controlled if the wind speed of the road in the tunnel was less than 1.25 m/s, and smoke could be controlled within 200 m from the fire if the damper interval was 50 m and 100 m.

A Laboratory-Scale Study of the Applicability of a Halophilic Sediment Bioelectrochemical System for in situ Reclamation of Water and Sediment in Brackish Aquaculture Ponds: Establishment, Bacterial Community and Performance Evaluation

  • Pham, Hai The;Tran, Hien Thi;Vu, Linh Thuy;Dang, Hien The;Nguyen, Thuy Thu Thi;Dang, Thu Ha Thi;Nguyen, Mai Thanh Thi;Nguyen, Huy Quang;Kim, Byung Hong
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.7
    • /
    • pp.1104-1116
    • /
    • 2019
  • In this study, we investigated the potential of using sediment bioelectrochemical systems (SBESs) for in situ treatment of the water and sediment in brackish aquaculture ponds polluted with uneaten feed. An SBES integrated into a laboratory-scale tank simulating a brackish aquaculture pond was established. This test tank and the control (not containing the SBES) were fed with shrimp feed in a scheme that mimics a situation where 50% of feed is uneaten. After the SBES was inoculated with microbial sources from actual shrimp pond sediments, electricity generation was well observed from the first experimental week, indicating successful enrichment of electrochemically active bacteria in the test tank sediment. The electricity generation became steady after 3 weeks of operation, with an average current density of $2.3mA/m^2$ anode surface and an average power density of $0.05mW/m^2$ anode surface. The SBES removed 20-30% more COD of the tank water, compared to the control. After 1 year, the SBES also reduced the amount of sediment in the tank by 40% and thus could remove approximately 40% more COD and approximately 52% more nitrogen from the sediment, compared to the control. Insignificant amounts of nitrite and nitrate were detected, suggesting complete removal of nitrogen by the system. PCR-DGGE-based analyses revealed the dominant presence of Methylophilus rhizosphaerae, Desulfatitalea tepidiphila and Thiothrix eikelboomii, which have not been found in bioelectrochemical systems before, in the bacterial community in the sediment of the SBES-containing tank. The results of this research demonstrate the potential application of SBESs in helping to reduce water pollution threats, fish and shrimp disease risks, and thus farmers' losses.

Mineralogical Changes of Oyster Shells by Calcination: A Comparative Study with Limestone (소성에 따른 굴패각의 광물학적 특성변화: 석회석과의 비교 연구)

  • Lee, Jin Won;Choi, Seung-Hyun;Kim, Seok-Hwi;Cha, Wang Seog;Kim, Kangjoo;Moon, Bo-Kyung
    • Economic and Environmental Geology
    • /
    • v.51 no.6
    • /
    • pp.485-492
    • /
    • 2018
  • About 300 thousand tones of oyster shells are produced annually and, thus, their massive recycling methods are required. Recently, a method, utilizing them as wet desulfurization materials after removal of organic matters and changing $CaCO_3$ phase into CaO through calcination, is under consideration. This study investigates the mineralogical changes (specific surface area, phase changes, surface state, etc.) of oyster shells by calcination and their characteristics were compared with those of limestone. Uncalcined oyster shells showed the higher specific surface area than limestone because the former are composed of platy and columnar structures. In contrast, investigated limestone showed a dense structure. The phase change of oyster shells occurred at lower temperature than that of limestone. The specific surface area of oyster shell decreased significantly after calcination while limestone depicted a drastic increase. Small amount of Na contained in oyster shell was suggested as the cause of this phenomenon; in that, it acted as a flux causing melting and sintering of oyster materials at lower temperature. Because of this, an additional phenomenon was observed that a part of shell materials remained untransformed even at higher calcination temperature and after longer treatment period due to the sintered surface, which covers the rest parts. Further studies investigating the effect of this phenomena from the perspective of desulfurization is required.

Evaluation of Cd Adsorption Characteristic by Microplastic Polypropylene in Aqueous Solution (수중에서 미세플라스틱인 Polypropylene의 Cd 흡착특성 평가)

  • Eom, Ju-Hyun;Park, Jong-Hwan;Kim, Seong-Heon;Kim, Yeong-Jin;Ryu, Sung-Ki;Seo, Dong-Cheol
    • Korean Journal of Environmental Agriculture
    • /
    • v.38 no.2
    • /
    • pp.83-88
    • /
    • 2019
  • BACKGROUND: In recent years, studies on microplastics have focused on their decomposition in the ocean. However, no studies have been reported on the interaction between microplastics and metal ions in aqueous solutions. Therefore, this study was conducted to evaluate the adsorption capacity of cadmium(Cd) by polypropylene (PP) in aqueous solution. METHODS AND RESULTS: Cadmium adsorption characteristics of PP in aqueous solution were evaluated through various conditions including initial Cd concentration(1.25-25 mg/L), contact time(0.5-24 h), initial pH(2-6) and temperature($20-50^{\circ}C$). Cadmium adsorption fit on PP was well described by Freundlich isotherm model with adsorption capacity(K) of 0.028. The adsorption amount of Cd by PP increased with increasing contact time, indicating that adsorption of PP by Cd was dominantly influenced by contact time. Especially, the removal efficiency of Cd by PP was highest at high temperature. However, the surface functional groups of PP before and after adsorption of Cd were similar, suggesting that adsorption of Cd by PP is not related to surface functional groups. CONCLUSION: Our study suggests that PP affects the behavior of Cd in aqueous solution. However, in order to clarify the specific relationship between microplastics and metal ions, mechanism research should be carried out.

Surgical Treatment of Chronic Tophaceous Gout in the 1st Metatarso-Phalangeal Joint (족부 제 1중족 족지 관절에 발생한 만성 결절성 통풍의 수술적 치료)

  • Lee, Tae-Hun;Nam, Il-Hyun;Ahn, Gil-Yeong;Lee, Yeong-Hyeon;Lee, Yong-Sik;Choi, Young-Deuk;Lee, Hee-Hyung
    • Journal of Korean Foot and Ankle Society
    • /
    • v.22 no.4
    • /
    • pp.156-160
    • /
    • 2018
  • Purpose: Chronic tophaceous gout is a painful and disabling inflammatory disease. Surgical treatment for chronic tophaceous gout is very difficult with many complications. This study evaluated the efficacy of shortening scarf osteotomy on the treatment of chronic tophaceous gout in the 1st metatarso-phalangeal (MTP) joint. Materials and Methods: From January 2006 to December 2015, 14 patients (19 cases) who underwent axial shortening scarf osteotomy for chronic tophaceous gout were reviewed. All patients were male. The average age at the time of surgery was 59.6 years (42~66 years). The minimum follow-up was 24 months. Total removal of the tophi mass with the adhered medial capsule of the 1st MTP joint was attempted. Axial shortening scarf osteotomy was done on the 1st metatarsal shaft. The visual analogue scale (VAS) for pain and the American Orthopaedic Foot and Ankle Society (AOFAS) forefoot score was assessed preoperatively and postoperatively. The range of motion (ROM) of the 1st MTP joint was also compared pre- and postoperatively. Results: The average size of the extracted tophaceous mass was 32 mm. The mean amount of the length of metatarsal shortening was 4.9 mm. The mean ROM of the 1st MTP joint was improved from $30.4^{\circ}$ to $62.3^{\circ}$. The mean AOFAS forefoot score improved from 51.4 to 86.6 points. The mean VAS for pain improved from 4.6 to 0.3 points. Conclusion: The axial shortening scarf osteotomy used on chronic tophaceous gout could reconstruct the 1st MTP joint with an improved ROM and was free of pain. Axial shortening scarf osteotomy is suggested as a useful and effective method for the treatment of chronic tophaceous gout.

Effect of Ozone on Gas Separation Membranes for On-Board Inert Gas Generation System (OBIGGS) (OBIGGS용 기체 분리막에서 오존이 미치는 영향)

  • Jung, Kyung Nam;Woo, Seung Moon;Kim, Se Jong;Kim, Ji Hyeon;Han, Sang Hoon;Nam, Sang Yong
    • Membrane Journal
    • /
    • v.28 no.6
    • /
    • pp.406-413
    • /
    • 2018
  • In OBIGGS, a small amount of ozone in the atmosphere damages the polymer membrane. Therefore, the ozone removal device is installed at the front end to prevent the damage of the membrane by reducing the concentration of ozone in the gas delivered to the membrane. In this study, two hollow fiber membranes, PI and PSf, used to fabrication hollow fiber module with an effective membrane area of $6.37cm^2$ for gas separation in OBIGGS. The ozone concentration in the chamber was maintained at 2-3 ppm. The gas was continuously supplied into the module by using a pump. The gas permeation characteristics and the tensile strength were evaluated as a function of ozone exposure time. The PI-based hollow fiber membrane showed only 20% reduction in the transmittance, and remained its original uniformity without any significant changes. However, when PSf type hollow fiber membranes were used, the permeability decreased by more than 80% and the tensile strength decreased by more than 70%.

Comparative Study of the Antioxidant Activity Effects of Gami-Sumiwon Extract using Water and 80% Ethanol (가미수미원의 열수 추출물과 80% 에탄올 추출물의 항산화 효능 비교)

  • Lim, Hyun-Ji
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.5
    • /
    • pp.1302-1313
    • /
    • 2021
  • In this study, Gami-Sumiwon (GS; Cynanchi wilfordii R., Angelica gigantis R., Lycium chinense M., Betula platyphylla S., Cryptotympana atrata F. and Carthamus tinctorius L.) and/or Sinomenium acutum R. (SC) was extracted with 70% ethanol or water. And We investigated the antioxidant activity effect of GS±SC. The following experimental techniques were used to evaluate the antioxidant efficacy of GS±SC. HPLC chromatogram, heavy metal content, ABTS/DPPH radical scavenging analysis, SOD-like activity assay, FACS, and NO assay. As a result of the experiment, the sinomenine content was found to be higher in DW extracts, and decursin was found to be higher in 80% ethanol extracts. And, the amount of heavy metals in all extracts was below the standard value. ABTS, and DPPH radical scavenging activity was identified that GS±SC(EtOH) was found to have a higher scavenging activity than GS±SC(DW). But, SOD showed the opposite result. No cytotoxicity of GS was observed on Raw 264.7 cells at concentration of 1~100 ㎍/㎖. The ROS production was significantly decreased that GS±SC(DW) was found to have a higher scavenging activity than GS±SC(EtOH). However, NO production showed the opposite result. Looking at the results of SOD and ROS analysis, SC does not seem to have a function of prevention. SC is thought to have an effect on the removal of free radicals generated after oxidative stress. This result objectively confirmed the antioxidant effect of GS±SCs. We will continue to conduct in-depth research. Therefore, it is believed that the possibility of using GS±SCs as a functional material can be established. The more diverse the objectives, the higher the value of GS utilization is thought to be.

Removal of residual VOCs in a collection chamber using decompression for analysis of large volatile sample

  • Lee, In-Ho;Byun, Chang Kyu;Eum, Chul Hun;Kim, Taewook;Lee, Sam-Keun
    • Analytical Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.23-35
    • /
    • 2021
  • In order to measure the volatile organic compounds (VOCs) of a sample which is too large to use commercially available chamber, a stainless steel vacuum chamber (VC) (with an internal diameter of 205 mm and a height of 50 mm) was manufactured and the temperature of the chamber was controlled using an oven. After concentrating the volatiles of the sample in the chamber by helium gas, it was made possible to remove residual volatile substances present in the chamber under reduced pressure ((2 ± 1) × 10-2 mmHg). The chamber was connected to a purge & trap (P&T) using a 6 port valve to concentrate the VOCs, which were analyzed by gas chromatography-mass spectrometry (GC-MS) after thermal desorption (VC-P&T-GC-MS). Using toluene, the toluene recovery rate of this device was 85 ± 2 %, reproducibility was 5 ± 2 %, and the detection limit was 0.01 ng L-1. The method of removing VOCs remaining in the chamber with helium and the method of removing those with reduced pressure was compared using Korean drinking water regulation (KDWR) VOC Mix A (5 μL of 100 ㎍ mL-1) and butylated hydroxytoluene (BHT, 2 μL of 500 ㎍ mL-1). In case of using helium, which requires a large amount of gas and time, reduced pressure ((2 ± 1) × 10-2 mmHg) only during the GC-MS running time, could remove VOCs and BHT to less than 0.1 % of the original injection concentration. As a result of analyzing volatile substances using VC-P&T-GC-MS of six types of cell phone case, BHT was detected in four types and quantitatively analyzed. Maintaining the chamber at reduced pressure during the GC-MS analysis time eliminated memory effect and did not affect the next sample analysis. The volatile substances in a cell phone case were also analyzed by dynamic headspace (HT3) and GC-MS, and the results of the analysis were compared with those of VC-P&T-GC-MS. Considering the chamber volume and sample weight, the VC-P&T configuration was able to collect volatile substances more efficiently than the HT3. The VC-P&T-GC-MS system is believed to be useful for VOCs measurement of inhomogeneous large sample or devices used inside clean rooms.

Development of an Acceptance Criteria Implementation Flow Chart for verifying the Disposal Suitability of Radioactive Waste from Decommissioning of Nuclear Power Plants (원자력발전소 해체 방사성폐기물 처분 적합성 검증을 위한 인수기준 이행 흐름도 개발)

  • Kim, Chang Lak;Lee, Sun Kee;Kim, Heon;Sung, Suk Hyun;Park, Hae Soo;Kong, Chang Sig
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.17 no.1
    • /
    • pp.65-75
    • /
    • 2021
  • When the decommissioning of South Korea nuclear power plants is promoted in earnest with the permanent shutdown of Kori Unit 1 in 2017, a large amount of various types of radioactive waste will be generated. For minimal generation and safe management of decommissioning waste, the waste should be made by appropriate classification of the dismantling waste characteristics in accordance with physical, chemical and radiological characteristics to meet the acceptance criteria of disposal facilities. Replacing the preliminary inspection at the site for the compliance of the waste acceptance criteria (WAC) of medium and low-level radioactive waste with the generator's own radioactive waste certification program (WCP), from the perspective of disposal, the optimization of waste management at the national level contributes to the efficient availability of disposal, such as the processing of non-conforming radioactive wastes at the site. To this end, it is important to evaluate radioactivity in each system and area such as nuclear reactors before decommissioning is carried out in earnest, and the prior removal of harmful wastes is important. From waste collection to waste disposal, decommissioning waste should be managed at each stage in consideration of the acceptance criteria of disposal facilities to minimize the generation of non-conforming waste.