• 제목/요약/키워드: Reliability Measurement Tool

검색결과 326건 처리시간 0.03초

무선망 설계/최적화 시뮬레이션 툴 의 다양한 신뢰도 향상 기법 (Various Techniques for Improving of the Reliability of the Wireless Network Design/Optimization Simulation Tool)

  • 전현철;류재현;박상진;박주열;김정철
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2006년도 하계학술대회
    • /
    • pp.39-42
    • /
    • 2006
  • There are various analysis functions(including prediction of path loss, analyzing of capacity and coverage, etc.) of simulation tool to design and optimize the mobile communication network. Its reliability absolutely effects the performance of mobile communication network. Especially as the wireless network highly advancing focused on data service, it more needs to research and develop on the standard establishment of reliability of the simulation tool. Also it is important the systematic research how to improve the reliability of simulation tool. In this paper, to give the concrete process and skill about how to improve reliability, we define the kinds of reliability at first. And then we explain the comparison results between real field measurement data and theoretic simulation data.

  • PDF

간호교육 프로그램 학습성과 간접측정도구의 활용을 위한 신뢰도 및 타당도 검증 (Validity and Reliability for the Use of Program Outcome Indirect Measurement Tool in Korean Nursing Baccalaureate Education)

  • 송미옥;김희영
    • 한국콘텐츠학회논문지
    • /
    • 제21권8호
    • /
    • pp.608-618
    • /
    • 2021
  • 본 연구는 간호대학생을 대상으로 개발된 프로그램 학습성과 간접측정도구의 활용을 위해 타당도와 신뢰도를 검증한 연구이다. 대상자는 국내 5개 간호학과의 재학생 396명이었으며, 자료수집은 2019년 11월 22일부터 12월 10일까지 이루어졌다. 자료분석은 IBM Statistics SPSS 21.0과 AMOS 21.0 프로그램을 이용하여 문항분석, 탐색적 및 확인적 요인분석을 실시하였다. 문항분석 결과 79개 문항이 모두 요인분석 대상으로 선정되었다. 탐색적 요인 분석결과 다른 요인과 함께 부하하는 5개의 문항이 삭제되었고 최종 요인부하량의 범위는 .37부터 .86이었으며, 12개 요인에 대한 총 분산은 71.71%로 나타났다. 확인적 요인분석결과 삭제된 문항은 없었으며, 최종 척도는 74개 항목으로 구성되었다. 척도의 평균 점수는 3.78점, Cronbach' α는 .98이었다. 본 연구를 통해 간호교육 프로그램 학습성과 간접측정도구의 타당도와 신뢰성이 검증되었으므로 간호대학생을 위해 보다 표준화된 측정도구로 사용될 수 있을 것이다.

발목관절 복합체의 가동범위 측정을 위한 중립위치와 측정방법의 신뢰도 (Reliability of the Joint Neutral Position and Measurement Methods of the Ankle Joint Complex Range of Motion)

  • 홍완성;김기원
    • The Journal of Korean Physical Therapy
    • /
    • 제23권4호
    • /
    • pp.45-51
    • /
    • 2011
  • Purpose: To determine the correct measurement methods of the ankle joint complex range of motion for measuring the neutral position and evaluate the rater reliability. In addition, the impact of training on the rater reliability was also assessed. Methods: The subjects were eleven healthy women, who were evaluated by two physical therapists and one physical therapist recorded the results of the study. Standard goniometer was used as the measurement tool. The ankle and subtalar joint neutral position and the active range of motion of the ankle and subtalar joint were measured. Intra-rater reliability and inter-rater reliability measures were analyzed with intraclass correlation coefficients. Results: Intra-rater reliability and inter-rater reliability ranged from high to medium for the neutral position of the ankle joint complex. Intra-rater reliability for dorsiflexion and plantarflexion measurements was medium, while the inter-rater reliability was high. The range of motion of the subtalar joint was measured, and the intra-rater reliability and inter-rater reliability were low and medium, respectively Also, the intra-rater reliability was increased with formal training of the measurement techniques. Intra-rater reliability was reduced in case the raters had not undertaken the training. Conclusion: In summary, the results obtained with the measurement tools and joint measurement of position, indicate the consistency of repeated measurements made by the same observers. Under the same circumstances along with repetition of the same measurement technique during training caused an increase in the rater reliability of formally trained raters.

여성의 성만족 측정을 위한 도구개발 (Development of Sexual Satisfaction Measurement Tool)

  • 김숙남;장순복;강희선
    • 대한간호학회지
    • /
    • 제27권4호
    • /
    • pp.753-764
    • /
    • 1997
  • This study was conducted to develop a sexual satisfaction tool for married women in Korea. The data was collected from July 19 to Aug 18, 1997 by means of questionnaires developed by researchers. The subject were 417 married women living in Seoul and Pusan. The process of this study was as follows : 1) The concept of sexual satisfaction was defined. 2) A conceptual framework was identified based on the extensive review of relevant literature and interviews with married women. 3) The preliminary question items containing the attributes and elements of the concept of sexual satisfaction were listed. 4) The preliminary items were revised after a pilot study. 5) The Index of Content Validity(CVI) was calculated from the content specialists' rating. 6) The reliability and validity of the sexual satisfaction measurement tool were tested. As a result of the item and factor analysis, 17 out of 30 items were found to be valid, consequently could be used to measure sexual satisfaction for married women. These final 17 items were divided into two factors. These factors were labeled as "situation factor" (10 items) and "response factor"(7 items) according to the attributes of the clustered items. The reliability of the final 17 items was .9118. Further research is needed to confirm the reliability and validity of the tool by applying it to a group of healthy married women and to a group of married women having health-related problem.

  • PDF

융합 시대의 의료종사자를 위한 단축형 생명의료윤리 도구 개발 및 평가 (Develop and Evaluate the Short Form Biomedical Ethics Tool for Medical Workers In Convergence Era)

  • 제남주;박미라
    • 디지털융복합연구
    • /
    • 제18권1호
    • /
    • pp.219-229
    • /
    • 2020
  • 본 연구는 의료종사자를 대상으로 단축형 도구를 개발하여 기존 도구와 비교하고, 생명의료윤리 의식 측정의 신뢰도를 높이기 위한 목적이었다. G도에 소재한 의료종사자 211명을 대상으로 자료수집 하였다. IBM SPSS WIN/21.0을 이용하여 베리맥스 회전추출방법을 이용하여 탐색적 요인분석을 하였으며, 원도구 점수와의 회귀분석 및 상관분석을 통해 도구의 수렴타당도를 검증하고, 급내상관계수와 내적일관성 계수를 산출하여 신뢰도를 검증하였다. 21개 문항으로 단축한 도구는 49개 문항 원 도구의 생명의료윤리의식의 84%를 반영하고 있으며, 간호대학생을 대상으로 한 29개의 단축형 도구보다 도구의 신뢰도가 높았으나, 하위영역의 구성문항과 신뢰도계수의 차이가 있었다. 추후 하위영역별 도구의 신뢰도를 높이기 위해 질적연구와 대상자 인터뷰를 통한 추가 문항개발이 필요하며, 다양한 윤리적 딜레마가 있는 임상현장에서 타당도와 신뢰도가 확보된 도구로 생명의료윤리 의식 측정이 필요하며 이에 대한 반복연구가 요구된다.

수학교사의 테크놀로지 교수 내용 지식(TPACK) 측정 도구 개발 및 타당화 (Development and Validation of TPACK Measurement Tool for Mathematics Teachers)

  • 이다희;황우형
    • 한국수학교육학회지시리즈A:수학교육
    • /
    • 제56권4호
    • /
    • pp.407-434
    • /
    • 2017
  • The purpose of this study is to develop and verify the TPACK measurement tool for middle and high school mathematics teachers in the Korean context. Also, by clarifying the relationship between subordinate factors of Mathematics teachers' TPACK, an attempt was made to provide suggestions on the designs and directions for the in-service and pre-service teacher education and the programs for improving mathematics teachers' TPACK in the future. In order to achieve this goal, TPACK factors of mathematics teachers were extracted by reviewing literature on PCK, MKT, and TPACK. Then, content validity, basic statistical survey, reliability verification, exploratory factor analysis, confirmatory factor analysis, and structural equation model verification were conducted sequentially. At first, preliminary analysis was carried out on 79 mathematics teachers, and 76 items excluding the items with extreme value and reliability were included in the basic statistical analysis. And secondly, an exploratory factor analysis was conducted on 376 mathematics teachers, and this instrument consisted of 7 subordinate factors(CK, PK, TK, PCK, TCK, TPK, TPACK) and 61 items. Also by conducting confirmatory factor analysis and structural equation model test with 254 mathematics teachers, the measurement tool was confirmed the validity and reliability through statistically significant analysis. Then, the importance of integrated knowledge was confirmed by looking at the relationship between the TPACK factors of in-service mathematics teachers. The integrated knowledge(PCK, TCK, TPK) has played a crucial role in the formation of TPACK rather than the knowledge of CK, PK, and TK alone. Finally, the validity of TCK was confirmed through the structural equation modeling of TPACK. TCK not only directly affected TPACK, but also indirectly through TPK. According to these affirmative results, this measurement tool is claimed to be suitable for measuring the factors of Mathematics teachers' TPACK, and also the structural equation model can be regarded as a suitable model for analyzing the structural relationship of mathematics teachers' TPACK.

주관절 가동범위 측정법에 대한 동시타당도와 신뢰도 (Concurrent Validity, Inter-Tester and Intra-Tester Reliability of Goniometric Measurement of Active Elbow Range of Motion Using 4 Different Types of Measuring Instruments)

  • 구애련;이충휘
    • 한국전문물리치료학회지
    • /
    • 제2권2호
    • /
    • pp.46-55
    • /
    • 1995
  • The purpose of this study was to assess the concurrent validity and reliability of goniometric measurement of joint motion. Subjects were 40 healthy university students. Measurements were performed by 4 inexperienced physical therapy students. Four different instruments were used and three readings were taken with each instrument in random order making a total of 12 readings for flexion of the right elbow of each subject. Goniometers used were 1. universal 2. fluid-based goniometer/inclinometer 3. digital LCD goniometer 4. electronic goniometer/torsiometer. The results were as follows: Concurrent validity was highest (r= .94) with the universal and digital LCD tools. Interrater reliability (Pearson Product Moment Correlation) was good for each tool. Interrater reliability calculated by ICC(2,1) was highest (.96) with the tensiometer and lowest (.78) with the digital LCD goniometer. Intrarater reliability calculated by ICC was excellent (${\geq}.90$) for all instruments. These results show that concurrent validity, intrarater and interrater reliability are very good in the used of all four types of goniometers/inclinometer/tensiometer, even with inexperienced raters. These results confirm the almost universal reliance on hand held goniometers for joint measurement by physical therapists as being a reliable practice. Further research should be done clinically with actual patients.

  • PDF

가정간호에 대한 돌봄만족도 측정도구 개발 - Watson의 돌봄개념을 중심으로 - (Development of the Tool for Measuring the Care Satisfaction of Home Health Nursing based on Watson's Theory of Human Caring)

  • 전연숙;강경아
    • 한국보건간호학회지
    • /
    • 제28권1호
    • /
    • pp.57-70
    • /
    • 2014
  • Purpose: This study is a methodological research study for development of a tool for measurement of care satisfaction of home health nursing in patients who have received care through home health nursing and to test the validity and reliability of the tool. Method: Based on Watson's theory of caring and its constituent factors, the literature related to home health nursing was reviewed, and the standard of home health nursing was compared and analyzed. For verification of the validation and reliability of the final tool which has been developed, data were collected from 166 people who were receiving home health nursing care. Result: According to results of analysis of the factors based on Kaiser and scree test, 10 factors with an eigenvalue greater than 1.0 were extracted, and they explained 72.26% of the total variance. In addition, the factor loadings of 56 questions were greater than .30. For verification of reliability, Cronbach's alpha for all 56 items was .98 and Guttman split half reliability coefficient was .90. Conclusion: This tool based on Watson's theory of caring contributed to development and application of the nursing theory through verification of the theory.

한국형 물리치료근무환경 측정도구 개발 및 평가 (Development and Validation of the Korean Physical Therapy Work Environment Scale (K-PTWES))

  • 이화경
    • 대한통합의학회지
    • /
    • 제12권2호
    • /
    • pp.65-76
    • /
    • 2024
  • Purpose : This study aimed to develop and validate a reliable tool, the Korean physical therapists' work environment scale (K-PTWES), for assessing the work environment of Korean physical therapists. The study also sought to examine the validity and reliability of the instrument. Methods : This methodological study involved the development and testing of the measurement tool. The conceptual framework was established through a literature review and in-depth interviews with clinical physical therapists. A total of 40 meaningful statements emerged from this process, leading to the generation of 29 primary items. Following a content validity test, 29 items were selected for the preliminary tool. Data were collected from 220 physical therapists across various job roles and unit types, such as outpatient and inpatient physical therapy rooms in domestic hospitals, with more than one year of experience. The final analysis included data from all 220 physical therapists. Results : Varimax rotated principal component analysis was employed for validities, revealing four factors: organizational support, working system, sustainable development, and relationship with coworkers, explaining a total variance of 54.97 %. The Cronbach's α coefficient for the final tool was .939, indicating high reliability. Conclusion : In this study, we developed a measurement tool reflecting the characteristics of the Korean physical therapists' work environment scale (K-PTWES). Our findings highlight the tool demonstrated both validity and reliability. Utilizing this tool is expected to contribute to understanding the work environment of Korean physical therapists and fostering a healthy work environment. Based on our findings, we recommend, firstly, conducting research on the work environment and related factors of physical therapists working in diverse settings using the K-PTWES. Secondly, future studies should focus on validating the tool's criterion-related validity, as it was not addressed in this research.

환자간호의 질 평가를 위한 돌봄(caring) 측정도구의 개발 (Development of a Measurement Tool of Caring to Evaluate Quality of Nursing Care)

  • 이병숙
    • 대한간호학회지
    • /
    • 제26권3호
    • /
    • pp.653-667
    • /
    • 1996
  • It is important to find indicators of quality nursing care to establish the excellence of nursing practice and for the development of nursing as a profession. Caring is one of the indicators which can represent professional nursing care. The purpose of this study was to develop a measurement tool of caring that could be used as an instrument for the evaluation of quality of nursing care. The Target population for the developed tool of caring is the adult patient. The mearsurement tool of caring was developed through the following steps. (1) A list of caring behaviors was made using qualitative researches on caring that has been done in Korea. (2) Caring behaviors in nurses were selected using the list of caring behaviors developed from Watson's 10 factors of caring. (3) Items for the measurement tool of caring were developed using the caring behaviors of nurses (4) Content validity of the developed items was evaluated by an expert panel. (5) The mearsurement tool of caring was developed after a pilot study (6) Internal consistency, and construct validity of the developed tool were verified. (7) The mearsurement tool of caring with the items verified for the internal consistency and construct validity was confirmed. As a result of the study, a mearsurement tool of caring, composed of 27 items with 3 factors, was developed. The Reliability coefficient of the tool was. 9578. The tool is a 5 point Likert scale. The factors of the tool and the number of items for each factor are, 1) accessibility and availablility, 15 items ; 2) emotional support and giving information, 8 items ; 3) providing a protective environment, 4 items.

  • PDF