• Title/Summary/Keyword: Release Device

Search Result 193, Processing Time 0.026 seconds

Development of Flight Model of Segmented Nut Type Holding and Release Mechanism Using Burn Wire Cutting Method for On-orbit Verification (열선절단형 분리너트식 구속분리장치의 궤도검증을 위한 비행모델 개발)

  • Lee, Myeong-Jae;Lee, Yong-Keun;Kang, Suk-Joo;Oh, Hyun-Ung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.911-915
    • /
    • 2014
  • Pyrotechnic devices are widely used for space appendages. However, a cube satellite requirements do not permit the use of explosive pyrotechnic device. A nichrome burn wire release has typically been used for holding and release of deployable appendages of the cube satellite due to its simplicity and low cost. However, relatively low mechanical constraint force and system complexity for application of multi-deployable systems are disadvantages of the conventional mechanism. To overcome these drawbacks, we have developed a segmented nut type holding and release mechanism based on the nichrome burn wire release. The great advantages of the mechanism are much lower shock level and larger constraint force than the conventional mechanism using pyro. Flight model for on-orbit verification was developed and verified through release function test, vibration test and thermal vacuum test.

  • PDF

방열기판 전극형성 기술 동향

  • Kim, Dan-Bi;Kim, Ji-Won;Eom, Nu-Si-A;Im, Jae-Hong
    • Ceramist
    • /
    • v.21 no.2
    • /
    • pp.83-88
    • /
    • 2018
  • There is close relation between the heat generation and the performance of electronic device. The durability and efficiency of the device are degraded due to heat generation. It is necessary to release the generated heat from an electronic device. Based on demands of the printed circuit board (PCB) manufacturing, the robust and reliable plating technique of PCB is necessary. In this study, we review various methods for improving the heat sink property. These methods were considered to enhance the adhesion between ceramic substrate as heat sink and metal layer as electrode.

Release Mechanism for small satellite using micro DC motor (소형 위성용 소형직류모터를 이용한 분리장치)

  • Tak, Won-Jun;Jo, Jae-Uk;Lee, Min-Soo;Kim, Byung-Kyu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.8
    • /
    • pp.767-773
    • /
    • 2010
  • This paper describes development of a non-explosive separation device which can be equipped on small satellites. The spur geared micro DC motor, which has high reliability and advantage of price, is adopted as an actuator. The proposed separation device has resettability and it does not need extra jig to reload. In addition, the simple structure makes it easy to fabricate and assemble. To verify the performance of the proposed device, the response time tests, maximum preload tests and maximum shock level tests were performed. Also, through the vibration tests and thermal vacuum tests, feasibility of the proposed separation device was shown in launching and space environments. Therefore, we expect that the proposed separation device can replace the imported separation devices in near future.

Non-Explosive Actuator Technology for Satellite Applications (인공위성용 비폭발식 분리장치 기술동향)

  • Lim, Jae-Hyuk;Kim, Kyung-Won;Kim, Sun-Won;Lee, Chang-Ho;Rhee, Ju-Hun;Hwang, Do-Soon
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.7 no.1
    • /
    • pp.97-104
    • /
    • 2009
  • Successful separation of satellites from launch vehicles and release its appendages such as solar arrays and antennas are one of the most important tasks for mission accomplishment during in-orbit maneuver. Especially, specific release devices called NEA(Non-Explosive Actuator) have been widely adopted to perform safe separation and release due to its outstanding performance of low functional shock (below 500g), no contamination and easy handing as opposed to the pyroshock device. In the paper, various kinds of NEA and its history of development are reviewed along with a summary on the domestic research trend.

  • PDF

Sustained Release Properties of Vitamin C in Chitosan Molecular network (키토산 분자네트 워크속에서 비타민 C의 지속적 방출 특성)

  • Han Sang-Mun
    • Journal of environmental and Sanitary engineering
    • /
    • v.20 no.2 s.56
    • /
    • pp.33-38
    • /
    • 2005
  • Chitosan is a dietary fiber because of a linear polysaccharide composed of $\beta-(1{\rightarrow}4)$-linked 2-amino-2-deoxy-D-glucopyranose. In this study, control release system of vitamin C has been estimated in chitosan molecular network as a vitamin C carrier of controlled release. The amount of released vitamin C were decreased in higher amount of chitosan concentration. Especially, vitamin C were slowly released from chitosan solution in dialysis membrane when compared with vitamin C solution alone in dialysis membrane. These result assumed that chitosan driving force is dependent on chitosan molecular weight and cationic property of amino group with anionic property of vitamin C.

Mechanism Design of Cube Satellite for Multi-deployable Structures and Autonomous System Operation after Launcher Separation (복수구조 전개 및 발사체 분리직후 시스템 자동운용을 위한 큐브위성의 메커니즘 설계)

  • Lee, Myoung-Jae;Jung, Hyun-Mo;Oh, Hyun-Ung
    • Journal of Aerospace System Engineering
    • /
    • v.7 no.3
    • /
    • pp.20-25
    • /
    • 2013
  • In case of cube satellite, it is difficult to realize the same performance as commercial satellite due to its highly restricted unit accommodation space. To maximize the performance of the cube satellite, design concept considering the multi-function of satellite is required. In this paper, mechanism design of cube satellite which is applicable for the holding and release of multi-deployable structures has been proposed and investigated. In addition, a switch mechanism design for the autonomous system operation just after the cube satellite separation from P-POD has also been proposed. The effectiveness of the mechanism design for holding and release of multi-deployable structures has been demonstrated by EM test of the holding and release mechanism.

Controlled Release Dosage Form of Narcotic Antagonist(I): Synthesis of Biodegradable Polyphosphazenes and Preparation and Release Characteristics of Naloxone Implant (마약길항제의 방출 제어형 제제 (제1보) : 생체분해성 polyphosphazenes의 합성과 나록손 이식제제의 제조 및 용출특성)

  • Park, Joo-Ae;Lee, Seung-Jin;Kim, Hyung-Kuk;Kim, Kil-Soo
    • Journal of Pharmaceutical Investigation
    • /
    • v.25 no.2
    • /
    • pp.109-116
    • /
    • 1995
  • For the administration of narcotic antagonist with short half-life and low patient compliance, the sustained release system using biodegradable matrix is effective. Polyphosphazenes are of considerable interest as biodegradable matrix systems for controlled release of drugs. In this study, biodegradable polyphosphazenes available for the sustained release implantable device were synthesized, and their application was examined. Poly[dichlorophosphazene] was synthesized by solution polymerization method and confirmed with IR spectrum. Poly[bis(ethyl glycinate) phosphazene] and poly[ (diethyl glutamate)-co-(ethyl glycinate)phosphazene] were then produced by substitution of amino acid alkyl esters for chloride side groups. Using these polymers, the implantable devices of 1 mm thickness and $10{\times}10\;mm$ size containing naloxone hydrochloride were prepared and their release and degradation profiles were measured. In the case of poly[bis(ethyl glycinate)phosphazene] with swelling characteristics, degradation rate was slower than the release rate, showing that the release rate is partly dependent on the swelling rate. In contrast, the degradation rate of polyl[(diethyl glutamate)-co-(ethyl glycinate)phosphazene] matrix was identical with release rate of naloxone hydrochloride. On the basis of these results, it is expected that these polymers can be applied to sustained release implantable systems delivering narcotic antagonist.

  • PDF

Fabrication and Characterization of Flurbiprofen loaded Chitosan Beads for Periodontal Regeneration (치주조직 재생용 플루르비프로펜 함유 키토산 비드의 제조 및 용출특성)

  • Rhee, Su-Jin;Park, Yoon-Jeong;Lee, Seung-Jin;Chung, Chong-Pyoung
    • Journal of Pharmaceutical Investigation
    • /
    • v.27 no.1
    • /
    • pp.71-77
    • /
    • 1997
  • With the aim of improving periodontal regeneration efficacy, as a biodegradable local drug delivery device, drug releasing chitosan beads were prepared. Chitosan beads were prepared through the formation of intermolecular or intramolecular ionic interaction bewteen chitosan and sodium tripolyphosphate and were loaded with flurbiprofen. The mean diameter of the beads was $250\;{\mu}m$. Drug loading efficiency was improved by regulating the pH of tripolyphosphate solution. The drug release kinetics mainly depended upon the hydrophobic properties of the flurbiprofen, that is, the release of flurbiprofen showed initial burst with rapid release for the first day followed by a levelling off of the release rate. However, the release rate could be controlled by the formulation factor including the pH, concentration of the tripolyphosphate solution, gelation time, drug contents. From these results, flurbiprofen loaded chitosan beads were anticipated as biodegradable local drug delivery devices for periodontal regeneneration.

  • PDF

The effectiveness of controlled release device against E. faecalis : in vitro study

  • Hong, Sang-Hee;Yoo, Yoon-Jung;Lee, Seung-Jong;Kum, Kee-Yeon
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.560-560
    • /
    • 2003
  • I. Objectives Intracanal medicament with antibacterial action is required to maximize the disinfection of the root canal system. The purpose of this study was to evaluate the efficacy of 2% chlorhexidine digluconate(CHX) and controlled release device(CRD) containing 20% CHX and chitosan coating, compared to calcium hydroxide as intracanal medicament against E. faecalis. II. Materials and Methods One hundred and twenty intact freshly extracted bovine incisors were used and were 0.5% NaOCl. Middle 1/3 portion of roots were sliced into 4mm thick section and cementum was removed using diamond burs and external diameter was approximally 6mm.(omitted)

  • PDF

Analog active valve control design for non-linear semi-active resetable devices

  • Rodgers, Geoffrey W.;Chase, J. Geoffrey;Corman, Sylvain
    • Smart Structures and Systems
    • /
    • v.19 no.5
    • /
    • pp.487-497
    • /
    • 2017
  • Semi-active devices use the building's own motion to produce resistive forces and are thus strictly dissipative and require little power. Devices that independently control the binary open/closed valve state can enable novel device hysteresis loops that were not previously possible. However, some device hysteresis loops cannot be obtained without active analog valve control allowing slower, controlled release of stored energy, and is presents an ongoing limitation in obtaining the full range of possibilities offered by these devices. This in silico study develops a proportional-derivative feedback control law using a validated nonlinear device model to track an ideal diamond-shaped force-displacement response profile using active analog valve control. It is validated by comparison to the ideal shape for both sinusoidal and random seismic input motions. Structural application specific spectral analysis compares the performance for the non-linear, actively controlled case to those obtained with an ideal, linear model to validate that the potential performance will be retained when considering realistic nonlinear behaviour and the designed valve control approach. Results show tracking of the device force-displacement loop to within 3-5% of the desired ideal curve. Valve delay, rather than control law design, is the primary limiting factor, and analysis indicates a ratio of valve delay to structural period must be 1/10 or smaller to ensure adequate tracking, relating valve performance to structural period and overall device performance under control. Overall, the results show that active analog feedback control of energy release in these devices can significantly increase the range of resetable, valve-controlled semi-active device performance and hysteresis loops, in turn increasing their performance envelop and application space.