Browse > Article
http://dx.doi.org/10.12989/sss.2017.19.5.487

Analog active valve control design for non-linear semi-active resetable devices  

Rodgers, Geoffrey W. (Department of Mechanical Engineering, University of Canterbury)
Chase, J. Geoffrey (Department of Mechanical Engineering, University of Canterbury)
Corman, Sylvain (Department of Mechanical Engineering, University of Canterbury)
Publication Information
Smart Structures and Systems / v.19, no.5, 2017 , pp. 487-497 More about this Journal
Abstract
Semi-active devices use the building's own motion to produce resistive forces and are thus strictly dissipative and require little power. Devices that independently control the binary open/closed valve state can enable novel device hysteresis loops that were not previously possible. However, some device hysteresis loops cannot be obtained without active analog valve control allowing slower, controlled release of stored energy, and is presents an ongoing limitation in obtaining the full range of possibilities offered by these devices. This in silico study develops a proportional-derivative feedback control law using a validated nonlinear device model to track an ideal diamond-shaped force-displacement response profile using active analog valve control. It is validated by comparison to the ideal shape for both sinusoidal and random seismic input motions. Structural application specific spectral analysis compares the performance for the non-linear, actively controlled case to those obtained with an ideal, linear model to validate that the potential performance will be retained when considering realistic nonlinear behaviour and the designed valve control approach. Results show tracking of the device force-displacement loop to within 3-5% of the desired ideal curve. Valve delay, rather than control law design, is the primary limiting factor, and analysis indicates a ratio of valve delay to structural period must be 1/10 or smaller to ensure adequate tracking, relating valve performance to structural period and overall device performance under control. Overall, the results show that active analog feedback control of energy release in these devices can significantly increase the range of resetable, valve-controlled semi-active device performance and hysteresis loops, in turn increasing their performance envelop and application space.
Keywords
nonlinear; control; design; semi-active; earthquake; energy dissipation; valve control;
Citations & Related Records
Times Cited By KSCI : 14  (Citation Analysis)
연도 인용수 순위
1 Ozbulut, O.E. and Hurlebaus, S. (2011a), "Energy-balance assessment of shape memory alloy-based seismic isolation devices", Smart Struct. Syst., 8(4), 399-412.   DOI
2 Ozbulut, O.E. and Hurlebaus, S. (2011b), "Re-centering variable friction device for vibration control of structures subjected to near-field earthquakes", Mech. Syst. Signal Pr., 25(8), 2849-2862.   DOI
3 Ozbulut, O.E. and Hurlebaus, S. (2012a), "Application of an SMA-based hybrid control device to 20-story nonlinear benchmark building", Earthq. Eng. Struct. D., 41(13), 1831-1843.   DOI
4 Ozbulut, O.E. and Hurlebaus, S. (2012b), "A comparative study on the seismic performance of superelastic-friction base isolators against Near-Field Earthquakes", Earthq. Spectra, 28(3), 1147-1163.   DOI
5 Ramallo, J.C., Johnson, E.A. and Spencer, B.F. (2002) " 'Smart' base isolation systems", J. Eng. Mech. - ASCE, 128(10), 1088-1099.   DOI
6 Rodgers, G.W., Mander, J.B., Chase, J.G., Mulligan, K.J., Deam, B.L. and Carr, A. (2007), "Re-shaping hysteretic behaviour - spectral analysis and design equations for semi-active structures", Earthq. Eng. Struct. D., 36(1), 77-100.   DOI
7 Som, A., Kim, D.H. and Son, H.S. (2015), "Semiactive magnetorheological damper for high aspect ratio boring process", Ieee-Asme Transactions on Mechatronics, 20(5), 2575-2582.   DOI
8 Sommerville, P., Smith, N., Punyamurthula, S. and Sun, J. (1997), "Development of Ground Motion Time Histories For Phase II Of The FEMA/SAC Steel Project, SAC Background Document Report SAC/BD-97/04.
9 Spencer, B.F., Dyke, S.J., Sain, M.K. and Carlson, J. (1997), "Phenomenological model of magnetorheological damper", J. Eng. Mech. - ASCE, 123(3), 230-238.   DOI
10 Spencer, B.F., Johnson, E.A. and Ramallo, J.C. (2000), " 'Smart' isolation for seismic control", Int. J. Series C-Mech. Syst. Machine Elem. Manufact. - Jsme, 43, 704-711.
11 Zhang, J.Q. and Agrawal, A.K. (2015), "An innovative hardware emulated simple passive semi-active controller for vibration control of MR dampers", Smart Struct. Syst., 15(3), 831-846.   DOI
12 Woo, S.S., Lee, S.H. and Chung, L. (2011), "Seismic response control of elastic and inelastic structures by using passive and semi-active tuned mass dampers", Smart Struct. Syst., 8(3), 239-252.   DOI
13 Yang, J.N. and Agrawal, A.K. (2002), "Semi-active hybrid control systems for nonlinear buildings against near-field earthquakes", Eng. Struct., 24(3), 271-280.   DOI
14 Yang, J.N., Bobrow, J., Jabbari, F., Leavitt, J., Cheng, C.P. and Lin, P.Y. (2007), "Full-scale experimental verification of resetable semi-active stiffness dampers", Earthq. Eng. Struct. D., 36(9), 1255-1273.   DOI
15 Bitaraf, M., Hurlebaus, S. and Barroso, L.R. (2012), "Active and semi-active adaptive control for undamaged and damaged building structures under seismic load", Comput. - Aided Civil Infrastruct. Eng., 27(1), 48-64.   DOI
16 Zhou, Z., Meng, S.P., Wu, J. and Zhao, Y. (2012), "Semi-active control on long-span reticulated steel structures using MR dampers under multi-dimensional earthquake excitations", Smart Struct. Syst., 10(6), 557-572.   DOI
17 Sun, C., Nagarajaiah, S. and Dick, A.J. (2014), "Family of smart tuned mass dampers with variable frequency under harmonic excitations and ground motions: closed-form evaluation", Smart Struct. Syst., 13(2), 319-341.   DOI
18 Barroso, L.R., Chase, J.G. and Hunt, S. (2003), "Resettable smart dampers for multi-level seismic hazard mitigation of steel moment frames", J. Struct.Control, 10(1), 41-58.   DOI
19 Beziat, A., Munoz, A.M., Chase, J.G., MacRae, G.A., Rodgers, G. W. and Clifton, C. (2012), "Performance analysis of energy dissipators and isolators placed in bridges to prevent structural damage in columns", J. Earthq. Eng., 16(8), 1113-1131.   DOI
20 Bitaraf, M. and Hurlebaus, S. (2013), "Semi-active adaptive control of seismically excited 20-story nonlinear building", Eng. Struct., 56, 2107-2118.   DOI
21 Bitaraf, M., Ozbulut, O.E., Hurlebaus, S. and Barroso, L. (2010b), "Application of semi-active control strategies for seismic protection of buildings with MR dampers", Eng. Struct., 32(10), 3040-3047.   DOI
22 Bobrow, J.E., Jabbari, F. and Thai, K. (2000), "A new approach to shock isolation and vibration suppression using a resetable actuator", ASME Transactions on Dynamic Systems, Measurement, and Control., 122(3), 570-573.   DOI
23 Caterino, N., Spizzuoco, M. and Occhiuzzi, A. (2015), "Shaking table testing of a steel frame structure equipped with semiactive MR dampers: comparison of control algorithms", Smart Struct. Syst., 15(4), 963-995.   DOI
24 Chase, J.G., Barroso, L.R. and Hunt, S. (2004), "The impact of total acceleration control for semi-active earthquake hazard mitigation", Eng. Struct., 26(2), 201-209.   DOI
25 Chase, J.G., Mulligan, K.J., Gue, A., Alnot, T., Rodgers, G., Mander, J.B., Elliott, R., Deam, B., Cleeve, L. and Heaton, D. (2006), "Re-shaping hysteretic behaviour using semi-active resettable device dampers", Eng. Struct., 28(10), 1418-1429.   DOI
26 Dyke, S.J. and Spencer, B.F. (1996), "Modeling and control of magnetorheological dampers for seismic response reduction", Smart Mater. Struct., 5(5), 565-575.   DOI
27 Chen, X.Q., Chase, J.G., Mulligan, K.J., Rodgers, G.W. and Mander, J.B. (2008), "Novel controllable semiactive-devices for reshaping structural response", Ieee-Asme Transactions on Mechatronics, 13, 647-657.   DOI
28 Bitaraf, M., Barroso, L.R. and Hurlebaus, S. (2010a), "Adaptive control to mitigate damage impact on structural response", J. Intel. Mat. Syst. Str., 21(6), 607-619.   DOI
29 Chen, Z.H., Ni, Y.Q. and Or, S.W. (2015), "Characterization and modeling of a self-sensing MR damper under harmonic loading", Smart Struct. Syst., 15(4), 1103-1120.   DOI
30 Chopra, A.K. (1995), Dynamics of structures : Theory and applications to earthquake engineering.
31 Esteki, K., Bagchi, A. and Sedaghti, R. (2015), "Semi-active control of seismic response of a building using MR fluid-based tuned mass damper", Smart Struct. Syst., 16(5), 807-833.   DOI
32 Ewing, C.M., Guillin, C., Dhakal, R.P. and Chase, J.G. (2009), "Spectral analysis of semi-actively controlled structures subjected to blast loading", Struct. Eng. Mech., 33(1), 79-93.   DOI
33 Feng, M.Q. (1993), "Application of hybrid sliding isolation system to buildings", J. Eng. Mech. - ASCE, 119(10), 2090-2108.   DOI
34 Feng, M.Q., Shinozuka, M. and Fujii, S. (1993), "Frictioncontrollable sliding isolation system", J. Eng. Mech. - ASCE, 119, 1845-1864.   DOI
35 Huang, Q.D., Gardoni, P. and Hurlebaus, S. (2015), "Assessment of modal parameters considering measurement and modeling errors", Smart Struct. Syst., 15, 717-733.   DOI
36 Kori, J.G. and Jangid, R.S. (2008), "Semi-active friction dampers for seismic control of structures", Smart Struct. Syst., 4(4), 493-515.   DOI
37 Jabbari, F. and Bobrow, J.E. (2002), "Vibration suppression with a resetable device", J. Eng. Mech. - ASCE, 128(9), 916-924.   DOI
38 Jansen, L.M. and Dyke, S.J. (2000), "Semiactive control strategies for MR dampers: Comparative study", J. Eng. Mech. - ASCE, 126(8), 795-803.   DOI
39 Katebi, J. and Zadeh, S.M. (2016), "Time delay study for semiactive control of coupled adjacent structures using MR damper", Struct. Eng. Mech., 58(6), 1127-1143.   DOI
40 Kim, Y., Langari, R. and Hurlebaus, S. (2010), "Control of a seismically excited benchmark building using linear matrix inequality-based semiactive nonlinear fuzzy control", J. Struct. Eng. - ASCE, 136(8), 1023-1026.   DOI
41 Maiti, D.K., Shyju, P.P. and Vijayaraju, K. (2006), "Vibration control of mechanical systems using semi-active MR-damper", Smart Struct. Syst., 2(1), 61-80.   DOI
42 Makris, N. and Chang, S.P. (2000), "Effect of viscous, viscoplastic and friction damping on the response of seismic isolated structures", Earthq. Eng. Struct. D., 29, 85-107.   DOI
43 Mulligan, K.J. (2007), Experimental and analytical studies of semi-active and passive structural control of buildings, PhD, University of Canterbury.
44 Mulligan, K.J., Chase, J.G., Mander, J.B., Rodgers, G.W. and Elliott, R.B. (2010), "Nonlinear models and validation for resetable device design and enhanced force capacity", Struct. Control Health Monit., 17(3), 301-316.   DOI
45 Ozbulut, O.E. and Hurlebaus, S. (2010), "Fuzzy control of piezoelectric friction dampers for seismic protection of smart base isolated buildings", Bull. Earthq. Eng., 8(6), 1435-1455.   DOI
46 Mulligan, K.J., Chase, J.G., Mander, J.B., Rodgers, G.W., Elliott, R.B., Franco-Anaya, R. and Carr, A.J. (2009), "Experimental validation of semi-active resetable actuators in a 1/5th scale test structure", Earthq. Eng. Struct. D., 38, 517-536.   DOI
47 Nagarajaiah, S. and Jung, H. J. (2014), "Smart tuned mass dampers: recent developments", Smart Struct. Syst., 13, 173-176.   DOI
48 Ozbulut, O.E., Bitaraf, M. and Hurlebaus, S. (2011), "Adaptive control of base-isolated structures against near-field earthquakes using variable friction dampers", Eng. Struct., 33(12), 3143-3154.   DOI