냉열원 온도 변화에 따른 다단재열랭킨사이클의 성능해석 (The Performance Analysis of Multi Stage Reheater Organic Rankine Cycle According to Heat Sink Temperature Change)

  • 이호생;임승택;김현주
    • 동력기계공학회지
    • /
    • 제20권1호
    • /
    • pp.11-17
    • /
    • 2016
  • In this study, the simulation for performance comparison between basic single stage organic rankine cycle, multi stage reheater cycle and multi stage reheater & recuperator cycle was carried out. The multi stage reheater cycle and multi stage reheater & recuperator cycle was designed to improve the efficiency for organic rankine cycle using heat source from industrial waste heat and heat sink from deep ocean water. R245fa was selected as a refrigerant for the cycle and system efficiencies were simulated by the variation of the heat sink temperature and the cycle classification. Performance characteristics were simulated by using the Aspen HYSYS. It was confirmed that the system efficiency was decreased by the increase of heat sink temperature. These results can be considered to be applied as geo-ocean thermal energy conversion in where plenty of geothermal or ocean thermal resource exist.

원전 습분분리재열기 튜브 번들 교체를 위한 열전달 고찰 (Heat Transfer Study to Replace a Tube Bundle of Moisture Separator Reheater at Nuclear Power Plant)

  • 최유성;최광희;이상국
    • 한국압력기기공학회 논문집
    • /
    • 제6권1호
    • /
    • pp.65-71
    • /
    • 2010
  • The plugging rate of reheater tubes of Wolsung unit 1 nuclear power plant has been increased by corrosion and erosion since 1990. As the dimensions of the new first stage reheater bundle tubes which were supplied by Hanjung company to replace were different from old one, numerical calculations are carried out for flow and heat transfer in the reheater bundle tubes of the N.P.P. Numerical calculations consists of thermal performance, drain line pressure drop, flow change by pressure drop of line, stress analysis of finned tubes and analysis of flow induced vibration. Computational analysis using heat transfer research institute program is adopted to verify the results of the numerical calculations. It contains the evalution of performance in the system with view to location of the new reheater bundle and it shows the differences between the numerical calculation results and heat transfer research institute program output.

  • PDF

석탄화력발전소의 재열저감수 저감방안 (Reduction of the Reheater Spray for Coal Fired Thermal Power Plant)

  • 김형덕;고철균;문승재
    • 플랜트 저널
    • /
    • 제9권2호
    • /
    • pp.46-50
    • /
    • 2013
  • 최근 발전회사들은 연료비 절감 방안으로 석탄화력발전소의 연료로 저열량탄 사용을 확대하고 있다. 하지만, 저열량탄 사용으로 비용절감이라는 장점을 가져오는 반면, 발열량이 낮은 탄종 연소 시 터빈에 공급되는 증기온도보다 높은 온도의 연소가스량 증가로 인한 대류열전달이 증가되어 재열기 온도 상승을 초래하게 되었다. 재열기 온도 상승은 재열기 튜브 피로증가와 발전소 효율 저하요인인 재열저감수 사용의 결과를 가져오게 된다. 따라서 재열기 출구온도와 관계된 운전변수들을 분석하여 재열기 출구온도를 적정하게 유지하여 재열저감수 사용량을 절감할 수 있는 방안에 관하여 논하였다.

  • PDF

해양지열발전용 다단재열재생사이클 성능해석 (Performance Analysis on the Multi Stage Reheater Regeneration Cycle for Ocean Geothermal Power Generation)

  • 이호생;차상원;정영권;김현주
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제17권2호
    • /
    • pp.116-121
    • /
    • 2014
  • 지열수를 온열원으로 사용하고, 해양심층수를 열침으로 사용하는 바이너리(binary) 지열 발전시스템은 기존 지열 발전시스템의 효율을 증대하기 위한 재열과정과 터빈출력을 향상시키기 위한 다단과정을 각각 또는 복합적으로 적용하여 다단재열재생사이클의 성능개선을 검토하였다. 사이클종류는 다단재열사이클(Multi Stage reheater cycle; MS), 다단재열재생사이클(Multi stage reheater regeneration cycle; MSR)이 있다. 작동유체는 R134a, R245fa를 적용하였으며 온열원의 온도가 $65^{\circ}C$, $75^{\circ}C$, $85^{\circ}C$ 열침은 $5^{\circ}C$를 적용하여 기본해석을 수행하였다. 본 논문에서는 온열원변화, 작동유체의 종류, 사이클의 종류에 따른 해양지열발전용 다단재열재생사이클의 출력 및 효율을 높이기 위한 해석을 수행하였다. 이를 열역학적 사이클로 모사하기 위한 상용 프로그램인 Aspen HYSYS(V8.0)를 이용하여 해석을 진행 하였다. 작동유체는 R245fa가 R134a보다 우수한 성능을 보였으며, 온열원의 변화와 각각의 사이클 종류에 따라 적절한 작동유체가 있음을 확인 할 수 있었다. 사이클의 출력 및 효율은 각각 MS사이클과 MSR사이클에서 좋은 성능을 나타냈다.

재열기 온도조절 급수배관의 진동저감방안 연구 (A Study on Vibration Control for Reheater Attemperator Piping in Power Plant)

  • 전창빈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1-5
    • /
    • 2007
  • A majority of piping vibration problems are induced by internal fluid pulsation; turbulent flow, vortex shedding at internal discontinuities, and pressure pulsation at equipment nozzles. The pulsation at the pressure sources resonates acoustically with the piping and the amplified pressure pulsation can generate shell mode vibration in the piping. Reheater attemperator piping supplies water from feedwater pump to reheater attemperator to control the boiler temperature. In normal operating condition, the high frequency shell mode vibration occurred in the piping with the high level of sound(105 ${\sim}$ 117 dB). The vibration sources are pressure pulsation in the pump nozzle and the frequencies are related to the blade passing frequencies. The objects of this paper are to analyze the cause of the high frequency vibration and to establish corrective actions.

  • PDF

100MW 발전소 개조 보일러의 증기온도 제어 (The Steam Temperature Control of Renovated Boiler in 100MW Power Plant)

  • 임건표;이흥호
    • 전기학회논문지
    • /
    • 제60권10호
    • /
    • pp.1935-1940
    • /
    • 2011
  • The control logic of steam temperature was redesigned, tested and applied to the power plant after its steam temperature equipments had been revised. This power plant use the ancillary gas gotten in the process of making iron in the steel mill. The boiler of power plant has the superheater and reheater to make the superheated steam. The superheater and reheater have the spray valve to control their temperature. The reheater has the gas bypass damper additionally in this plant. The control logics were redesigned in cascade forms and the initial parameters of control logics were calculated from the several step tests. The final parameters could be obtained through the several repeated tests and the feedforward functions were added by temperature deviation and air flow. The power plant is being commercially-operated normally by improved control logics and It is expected that this improved controls help the efficiency improvement and safe operation of plant.

관류형 증기발생기를 사용한 복합발전용 초임계압 하부시스템의 성능 설계해석 (Performance Design Analysis of the Supercritical Pressure Bottoming System of Combined Cycle Power Plants Using Once-Through Steam Generator)

  • 양진식;김동섭;노승탁
    • 대한기계학회논문집B
    • /
    • 제26권10호
    • /
    • pp.1370-1377
    • /
    • 2002
  • This study analyzed the design performance of the bottoming system of combined cycle power plants using a once-through heat recovery steam generator. For a parallel arrangement of the main heater and reheater, parametric analyses were carried out to present the criteria for determining the reheater pressure and the location of the starting point of the reheater in the HRSG. The performance of the bottoming system was presented fer a range from high subcritical to supercritical pressure. The steam turbine power is as high as that of conventional triple-pressure bottoming systems. The serial arrangement of heat exchangers with division of each heater into several segments can achieve similar power level.

원자력발전소 습분분리재열기 튜브 원격장검사 기술 개발 (Development of Remote Reld Testing Technique for Moisture Separator & Reheater Tubes in Nuclear Power Plants)

  • 남민우;이희종;김철기
    • 비파괴검사학회지
    • /
    • 제28권4호
    • /
    • pp.339-345
    • /
    • 2008
  • 원자력발전소 열교환기 튜브의 대부분은 구리, 티타늄, 인코넬합금 등의 비자성체로 제작되어 있으나 2차 터빈계통의 습분분리재열기(moisture separator & reheater), 급수가열기 등의 튜브는 고압, 고온 등의 열악한 운전조건에서 상대적으로 고온 강도가 우수한 탄소강 또는 페라이트계열 스테인레스강 등의 자성체로 제작되어 있다. 특히 습분분리재열기 튜브와 같은 열교환 매체가 증기인 경우 열전달 능력을 증가시키기 위해서 핀 튜브를 사용한다. 탄소강 또는 페라이트계열 스테인레스강 등의 자성체 튜브는 고온, 고압에서 강도가 우수하지만 운전 중에 증기 커팅, 침식, 기계적 진동 마모, 응력부식균열 등의 사용 중 결함이 발생하여 발전소 정상운전에 지장을 초래할 수 있기 때문에 전열관의 건전성 평가를 위한 주기적인 비파괴검사의 수행이 필요하다. 하지만 자성체 열교환기 튜브는 투자율이 높은 전기적 특성으로 인하여 기존의 와전류검사기술로는 비파괴검사가 어렵기 때문에 원격장검사기술을 적용해야 한다. 따라서 본 연구에서는 원자력발전소 습분분리재열기세관의 현장적용에 필요한 검사기술을 개발하기 위해서 원격장탐촉자, 인공결함 시험편 및 탐촉자 구동장치를 설계하였으며, 이를 활용하여 발전소 현장 검사에 적용하였다.

Immune Based 2-DOF PID Controller Design for Complex Process Control

  • Kim, Dong-Hwa
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.70.2-70
    • /
    • 2002
  • In the thermal power plant, it is difficult to maintain strict control of the steam temperature in order to avoid thermal stress, because of variation of the heating value according to the fuel source, the time delay of changes in main steam temperature versus changes in fuel flow rate, difficulty of control on the main steam temperature control and the reheater steam temperature control system owing to the dynamic response characteristics of changes in steam temperature and the reheater steam temperature, fluctuation of inner fluid water and steam flow rates widely during load-following operation. Up to the present time, the PID controller has been used to operate this system...

  • PDF