• Title/Summary/Keyword: Reference-Pulse

Search Result 324, Processing Time 0.023 seconds

Modified Digital Pulse Width Modulator for Power Converters with a Reduced Modulation Delay

  • Qahouq, Jaber Abu;Arikatla, Varaprasad;Arunachalam, Thanukamalam
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.98-103
    • /
    • 2012
  • This paper presents a digital pulse width modulator (DPWM) with a reduced digital modulation delay (a transport delay of the modulator) during the transient response of power converters. During the transient response operation of a power converter, as a result of dynamic variations such as load step-up or step-down, the closed loop controller will continuously adjust the duty cycle in order to regulate the output voltage. The larger the modulation delays, the larger the undesired output voltage deviation from the reference point. The three conventional DPWM techniques exhibit significant leading-edge and/or trailing-edge modulation delays. The DPWM technique proposed in this paper, which results in modulation delay reductions, is discussed, experimentally tested and compared with conventional modulation techniques.

Analysis on Core Loss of Brushless DC Motor Considering Pulse Width Modulation of Inverter

  • Kim, Ki-Chan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1914-1920
    • /
    • 2014
  • In this paper, characteristics of blushless direct current (BLDC) motor including core loss are analyzed considering pulse width modulation (PWM) of inverter. Input voltage of BLDC motor due to PWM is calculated considering duty ratio and carrier frequency of inverter in order to control torque or speed of BLDC motor. For the calculation of core loss, the input current with harmonics due to PWM voltage is calculated by using equivalent circuit model of BLDC motor according to switching pattern and carrier frequency. Next, core loss is analyzed by inputting the currents as a source of BLDC motor for FEM. Characteristics including core loss are compared with ones without PWM waveform according to reference speed.

Unequal-path Low-coherence Interferometry Using Femtosecond Pulse Lasers for Surface-profile Metrology (펨토초 레이저를 이용한 형상 측정용 비동일 광경로 저결 맞음 간섭계)

  • Oh, Jeong-Seok;Kim, Seung-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.9 s.186
    • /
    • pp.102-110
    • /
    • 2006
  • We discuss two possibilities of using femtosecond pulse lasers as a new interferometric light source for enhanced precision surface-profile metrology. First, a train of ultra-fast laser pulses yields repeated low temporal coherence, which allows unequal-path scanning interferometry, which is not feasible with white light. Second, the high spatial coherence of femtosecond pulse lasers enables large-sized optics to be tested in nonsymmetric configurations with relatively small-sized reference surfaces. These two advantages are verified experimentally using Fizeau and Twyman-Green type scanning interferometers.

A Simple Method for Conducting Angle Calculation of Switch Devices in Cascaded Inverters Using Step Pulse Waves (스텝 펄스파를 사용하는 캐스케이드 인버터에서 스위치의 간단한 도통각 계산법)

  • Kim H.C.;Kim T.J.;Kang D.W.;Hyun D.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.588-592
    • /
    • 2003
  • In recent years, the multilevel inverter synthesizing the output voltage with step pulse has been widely used as a solution for high power and high voltage applications. This paper proposes a simple method to obtain the conducting . angle. It is calculated by using voltage-second areas of the divided reference voltage according to the output voltage levels and these areas have influence on output step pulse waves. It is possible to reduce an amount of calculation because it is not required to solve the simultaneous equations by an iterative method. Also, the proposed method can get the conducting angle by means of on line.

  • PDF

A CELP Speech Coder Using Dispersed-Pulse and Random Codebook (분산펄스와 랜덤 코드북을 이용한 CELP 음성 부호화기)

  • 황윤성;문인섭;이행우;김종교
    • Proceedings of the IEEK Conference
    • /
    • 2001.06d
    • /
    • pp.115-118
    • /
    • 2001
  • This paper presents dispersed-pulse and random codebook for CELP coder. This coder operates on speech frames of 20ms and generates an excitation vector by convoluting dispersion vectors with signed pulses in an algebraic codevector. The improvement of pulse-based fixed codebook is performed at a low bit rate. A high performance fixed-codebook consists of a partial algebraic codebook and a random codebook in unvoiced and stationary noise regions. The proposed CELP coder is quantized with 4kb/s and is compared with G.729 (Bkb/s CS-ACELP). Subjective testing shows better quality than reference coders under some background noise conditions

  • PDF

The Design of MRAC using Block Pulse Functions (블럭펄스함수를 이용한 MRAC설계)

  • Kim, Jin-Tae;Kim, Tai-Hoon;Ahn, Pius;Lee, Myung-Kyu;Shim, Jae-Sun;Ahn, Doo-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2252-2254
    • /
    • 2001
  • This paper proposes a algebraic parameter determination of MRAC (Model Reference Adaptive Control) controller using block Pulse functions and block Pulse function's differential operation. Generally, adaption is performed by solving differential equations which describe adaptive low for updating controller parameter. The proposes algorithm transforms differential equations into algebraic equation, which can be solved much more easily in a recursive manner. We believe that proposes methods are very attractive and proper for parameter estimation of MRAC controller on account of its simplicity and computational convergence.

  • PDF

Unequal-path Low-coherence Interferometry Using Femtosecond Pulse Lasers (펨토초 레이저를 이용한 비동일 광경로 저결맞음 간섭계)

  • Oh J.S.;Kim S.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.204-207
    • /
    • 2005
  • We discuss two possibilities of using femtosecond pulse lasers as a new interferometric light source fer enhanced precision surface profile metrology. First, a train of ultra-fast laser pulses yields repeated low temporal coherence, which allows performing unequal-path scanning interferometry that is not feasible with white light. Second, high spatial coherence of femtosecond pulse lasers enables to test large size optics in non-symmetric configurations with relatively small size reference surfaces. These two advantages are verified experimentally using Fizeau and Twyman-Green type scanning interferometers.

  • PDF

Optimization of Wave Forms for Pulsed Amperometric Detection of Cyanide and Sulfide with Silver-Working Electrode

  • Park, Seong U;Hong, Seong Uk;Yu, Jae Hun
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.2
    • /
    • pp.143-146
    • /
    • 1996
  • A continuous potential pulse is applied to a silver-working electrode on a pulsed amperometric detector (PAD) for detection of free cyanide and sulfide. The moving phase is 0.1 M sodium hydroxide, 0.5 M sodium acetate and 5% (v/v) ethylenediamine mixture, and the flow rate is 0.7 mL/min. Optimized pulse conditions include a -200 mV (vs. Ag/AgCl reference electrode) detection potential(Ed) for 60 msec and 50 mV cleaning potential (Ec) for 120 msec. The silver working electrode surface is not poisoned by cyanide or sulfide, and the PAD maintains long-term stability without loss of sensitivity and reproducibility at these pulse conditions. The detection limit of cyanide and sulfide separated by ion chromatography using an anion exchange column is 0.1 ppm and 0.05 ppm, respectively.

A Study on the Electromagnetic Pulse Shielding Effect of Concrete Wall Sprayed with Cu-based Metal (Cu계 금속을 용사한 콘크리트 벽체의 전자파 차폐 성능에 관한 연구)

  • Jang, Jong-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.18-19
    • /
    • 2020
  • The ElectroMagnetic Pulse (EMP) destroys social infrastructure at once and causes social chaos. However, currently major infrastructures are constructed of concrete that does not have electromagnetic shielding performance. In this study, using the arc metal spraying method is used to evaluate the shielding performance and construction performance of concrete. The electro-magnetic shielding effect is measured by fabricating a shielding room with reference to MIL-STD-188-125, and the construction performance is evaluated by measuring the adhesion strength of thin metal sprayed film-concrete. As a result of the study, when the metal spraying method is applied, the shielding effect is higher than that of the special electro-magnetic shielding concrete, and it is considered to be more economical than the existing metal plate (3~5 mm).

  • PDF

Development of Clinical Protocol for Acquisition of Change of Radial Pulse Wave Signal in the Cold-Heat Intervention: Explanatory, Randomized, 2×2 cross-over design (냉온 부하에 따른 요골동맥 맥파의 변화 특성을 파악하기 위한 무작위 배정·2×2교차설계 탐색적 임상시험계획서 개발)

  • Yu, Hana;Kim, Jihye;Ku, Boncho;Kim, Hyunho;Jeon, Youngju
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.19 no.2
    • /
    • pp.91-100
    • /
    • 2015
  • Objectives The aim of this study is to develop a structured clinical protocol related with acquisition of radial pulse wave in the randomized, $2{\times}2$ cross-over design, and cold-heat intervention trial for a pilot and preliminary study. Methods The protocol was contrived based on wide ranging literature searches for cold-heat intervention experiments and radial pulse diagnoses. Results Sample size of 60 subjects was calculated based on an effect size derived from the previous study designed to detect the pre-post cold-heat differences in the radial pulse. Each subjects will be randomly assigned to the cold (first) to heat (last) group (n=30) or heat (first) to cold (last) group (n=30). All subjects will fill out a case report form and questionnaires related with pattern identification, dietary patterns, sleep quality, and physical activity will be surveyed and used as a secondary outcomes. Safety assessment will be reported at the final stage. Conclusions This protocol will provide an additional reference to future studies related with observation of radial pulse during any interventions and also expect to be used as a guideline for acquisition of reliable radial pulse wave data.