• Title/Summary/Keyword: Reefer Container

Search Result 17, Processing Time 0.022 seconds

Real-time Reefer Container Control Device Using M2M Communication (M2M통신을 이용한 실시간 냉동컨테이너 제어 장비)

  • Moon, Young-Sik;Choi, Sung-Pill;Lee, Eun-Kyu;Kim, Tae-Hoon;Lee, Byung-Ha;Kim, Jae-Joong;Choi, Hyung-Rim
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.9
    • /
    • pp.2216-2222
    • /
    • 2014
  • A recent trend of increasing container traffic volume using reefer container demands continuous management of reefer container in transit. However, reefer containers can only be monitored at terminal or in ship during marine transportation instead of throughout entire section. In the case of inland transportation section using truck or train, monitoring is not possible currently. The reason is because the reefer container monitoring method using PCT recommended by IMO and conventional monitoring methods using TCP/IP, RFID communication require establishing additional communication infrastructure. This paper will propose a new reefer container control device that not only solves these problems and monitors during inland transportation section but also controls reefer container. Using data port attached to every reefer container, the proposed device collects the information of reefer container and using M2M communication technology, it transmits information to server without the need to establish additional communication infrastructure. In addition, it can control the operational status of reefer container upon receiving control information set in server such as temperature of reefer container.

Temperature Control Algorithm for Reefer Container (냉동컨테이너 온도 제어 알고리즘에 관한 연구)

  • Moon, Young-Sik;Park, Shin-Jun;Jung, Jun-Woo;Choi, Hyung-Rim;Kim, Jae-Joong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.12
    • /
    • pp.2380-2386
    • /
    • 2017
  • Fresh agricultural product in Korea are currently being exported overseas through expensive air transportation, supported by the governments's farm export subsidies. However all members of the World Trade Organization(WTO) must halt government subsidies by 2023. Accordingly, it is necessary to use marine transport capable of carrying freight at low cost. Reefer containers are used for marine transportation of fresh produce but it have a problem due to the temperature difference inside the reefer container which causes of fresh cargo and drop in freshness during sea transportation. In order to solve the problem, we developed a temperature control algorithm for reefer container that maintain a constant temperature and minimizes the deviation inside reefer container. The result showed that the maintained a constant temperature within a maximum of $0.5^{\circ}C$ based on the set-point of $4.0^{\circ}C$ inside reefer container.

On the Calculation of Energy Requirement for Freight Train Reefer Container and Methods of Supplying the Power

  • Kim, Joouk;Hwang, Sunwoo;Lee, Jae-Bum;Kim, Youngmin
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.2
    • /
    • pp.79-88
    • /
    • 2022
  • Recently, securing stable supply of fresh food is deemed as one of the important tasks. Accordingly, now the presence of cold chain along with the needs of a comfortable and healthy life is growing as the online market expands and the contactless industry grows, however, cold chain is being studied only in the aspect of ground and sea transportation. And, due to global warming and strengthening global environmental regulations, we believe that it is necessary to convert the existing road-centered logistics system into a railway-centered logistics system, a low-carbon transportation means. Therefore, in this paper we calculated the maximum energy required by the reefer container as a basic research necessary for constructing the low temperature distribution and cold chain based on the reefer container railway, and conducted a study on methods of supplying the reefer container power utilizing 1. tramline, 2. battery, 3. generator. The results of this paper can be utilized as a foundational study for building a cold chain based on a reefer container dedicated to freight trains in the future.

A Study on the Optimization of Temperature Deviation of Loads in Smart Reefer Container (스마트냉동컨테이너의 적재부 온도 편차 최적화에 관한 연구)

  • SangWon Park;TaeHoon Kim;DoMyung Park;DongSeop Han
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.28 no.6
    • /
    • pp.83-90
    • /
    • 2023
  • In a reefer container, temperature deviation occurs between the front of the loading part with the refrigerator and the rear of the loading part with the container door due to the external environment. In particular, this temperature deviation in the transport of fresh cargo has a great influence on the freshness of the cargo. In this study, we propose a method to minimize the temperature deviation by partially shielding the T-Floor to reduce the temperature deviation and evaluating the effect of the T-Floor shielding rate on the temperature change of the reefer container loading part. The subject of the experiment was a 40 feet smart reefer container, and the T-Floor shielding rates were set to 0%, 50%, 60%, 70%, and 80%. As a result of the experiment, it occurred differently in the temperature deviation of the reefer container loading part according to the shielding rate, and it was confirmed that the temperature deviation was the most uniform when the shielding rate was 60%. By minimizing the temperature deviation of the loading part, it is possible to prevent corruption and cold damage of cargo during transportation of fresh cargo by using the smart reefer container.

On the Design of Power Supply System for Freight Train Reefer Container Based on Simulation

  • Kim, Joouk;Hwang, Sunwoo;Lee, Jae-Bum;Hwang, Jaemin;Chae, Uri
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.3
    • /
    • pp.249-257
    • /
    • 2022
  • In recent years, if we order food by easily accessing the online market with our smartphone, we can receive the product in a fresh state at dawn the next day. Cold chain is an industry that can create high added value because it has both the characteristics of general logistics and sensitivity to temperature. Based on the electrical specifications derived from the reefer container capacity requirement investigation, we proved that power supply to up to 33 reefer containers can be made by using three additional auxiliary power supplies which are applied for freight trains in Korea. In this paper, we conducted a research on a design of power supply system for freight train reefer container based on simulation as a basic research necessary for low-temperature distribution and cold chain construction based on the reefer container railroad. Consequently, the simulation was conducted using the three-phase inverter diagram in PSIM and the SVPWM (3-harmonic injection method) control technique, and it was verified that the required power voltage was satisfied with 622Vdc, which is lower than the input voltage of general SPWM of 718Vdc. The details of this paper could be used as a foundational study for constructing cold chains based on a reefer container dedicated to freight trains in the future.

Effectiveness of controlled atmosphere container on the freshness of exported PMRsupia melon (CA 컨테이너를 이용한 수출 멜론의 선도유지 효과)

  • Haejo Yang;Min-Sun Chang;Puehee Park;Hyang Lan Eum;Jae-Han Cho;Ji Weon Choi;Sooyeon Lim;Yeo Eun Yun;Han Ryul Choi;Me-Hea Park;Yoonpyo Hong;Ji Hyun Lee
    • Food Science and Preservation
    • /
    • v.30 no.5
    • /
    • pp.822-832
    • /
    • 2023
  • This study investigates the effectiveness of CA (controlled atmosphere) containers in maintaining the freshness of exported melons. The melons were harvested on June 5, 2023, in the Yeongam area of Jeollanam-do, Korea. The CA container was loaded with melon samples packed in an export box. The temperature inside the container was set at 4℃, while the gas composition was set at 5% oxygen, 12% carbon dioxide, and 83% nintrogen. Following two weeks of simulated transportation, quality analysis was conducted at 10℃. The melons were inoculated with spore suspensions, and the decay rate was determined to investigate the effect of the gas composition inside the CA container on suppressing the occurrence of Penicillium oxalicum in melons. The results were compared with a Reefer container set at the same temperature. The samples transported in the CA container exhibited lower weight loss. The melon pulp softening, respiration rate, and ethylene production were slower using the CA container. Moreover, the decay rate during the distribution period in the CA container was lower than in the Reefer container. In contrast, the firmness of melons transported in the Reefer container decreased significantly (from 9.03N to 5.18N) immediately after transportation. The soluble solid content (SSC) of melons transported in the Reefer container also decreased rapidly. The results suggested that the CA container is the optimal export container for maintaining the freshness of melons.

A Study on the Improvement of Damage to Reefer Container Cargo (냉동(冷凍)컨테이너 화물손상(貨物損傷)의 개선방안(改善方案)에 관한 연구(硏究))

  • Park, Sang-Kab;Park, Young-Gil;Shin, Young-Ran
    • Journal of Navigation and Port Research
    • /
    • v.36 no.10
    • /
    • pp.803-810
    • /
    • 2012
  • Since the introduction of reefer container for seaborne transportation, international trade of reefer products has increased continuously with the development of refrigerate technology, increased speed of the ship and change of consumption pattern. Reefer cargo is perishable and sensitive to temperature, humidity compared with general cargo and normally reefer cargo is more valuable than general cargo. Therefore it needs special care for its handling in transit including land and sea in order to prevent cargo damage. However, lots of claims relating to reefer cargo damage rise frequently in workplace. It may increase unnecessary logistic cost and time. The aim of this study is to improve and prevent damage to reefer container cargo in transit for the purpose of benefits to both merchants and carriers to save unnecessary logistic cost and time as well as to contribute to deliver the cargo more safely and efficiently to destination.

Design of Reefer Container Monitoring System based on Wireless Sensor Network (무선 센서 네트워크를 이용한 냉동 컨테이너 모니터링 시스템 설계)

  • Lee, Ki-Wook;Kim, Jung-Yee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.5
    • /
    • pp.321-326
    • /
    • 2007
  • The contents of reef container face a risk of being damaged if the interior temperature and certain maintenance conditions for the shipments cannot be met. Currently, the temperature and other conditions within a reefer container is checked manually and periodically by someone in charge of it. Since it means that there is no real-time checking of the conditions, if something goes wrong, there is no immediate means of correcting the problem. This paper introduces reefer container monitoring system, that checks interior temperature of container on real-time by sensor nodes attaching reefer container using wireless sensor network. It senses the temperature, amount of light, motion and the change in speed of the objects that distributes sensors throughout the desired places and sends the data wirelessly to anyone interested. Because the prosed technique can check the temperature and other conditions within a reefer container on real-time basis, it enables efficient and effective maintenance of temperature and other conditions

  • PDF

Reefer Container Monitoring System using Trajectory Information (궤적 정보를 이용한 냉동 컨테이너 모니터링 시스템)

  • Lee, Myung-Jin;Lee, Eung-Jae;Ha, Deok-Cheon;Ryu, Keun-Ho;Baek, Seung-Jae
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.8 no.1
    • /
    • pp.23-39
    • /
    • 2005
  • As developing satellite communication, the tracking range of the moving objects which move in local area is expanded to the whole world. However previous logistics management system is able to monitor freight which transporting in local area using mobile communication system. In this paper, we propose the reefer container management system that manages the location information and other related information such as temperature, humidity of container using the satellite system. The proposed system consists of three parts; data collector, satellite communication manager, reefer container information manager. And the proposed system uses the moving object index for managing the trajectory of container and tracing the location of container or vessel that is transporting the container, and supports various services such as reefer container and vessel tracking, container control and container statistics to logistic companies like shipper and forwarding agent. And the system can be increasing the quality of container transportation service to the shipper, and it makes the efficient management of reefer container to the shipping company.

  • PDF

Real-Time Management System of Reefer Container based on IoT (IoT 기반 냉동컨테이너 실시간 관리 시스템)

  • Moon, Young-Sik;Jung, Jun-Woo;Choi, Sung-Pill;Kim, Tae-Hoon;Lee, Byung-Ha;Kim, Jae-Joong;Choi, Hyung-Lim
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.9
    • /
    • pp.2093-2099
    • /
    • 2015
  • To prevent damage to the cargo, monitoring and remote management for reefer containers is necessary. The currently used remote monitoring service is the Power Cable Transmission(PCT) system, which is recommended by the International Maritime Organization(IMO). However, this system is not widely used because it requires a separate PCT infrastructure and is susceptible to data loss problems. To solve this problem, this study introduces the "IoT-based reefer container management system", The proposed system which is attached to reefer container collects and transmits data on the temperature, status and location of reefer container to middleware using RS-232 communication and WCDMA/GSM communication. Middleware is store the data received in the database and provide information to user in real time through the web and mobile program. At this time, users able to change setting temperature in real time from a distant place through the web program. This study tested by transit about shipment of strawberries to monitor and analyze and check the system's overall effectiveness.