• Title/Summary/Keyword: Redundant Operation

Search Result 134, Processing Time 0.025 seconds

An Improved Base Station Modulator Design for a CDMA Mobile System

  • Kim, Jin-Up;Uh, Yoon;Kweon, Hye-Yeoun
    • ETRI Journal
    • /
    • v.18 no.4
    • /
    • pp.215-227
    • /
    • 1997
  • We propose a new method to eliminate completely the redundant elements in a CDMA (code division multiple access) mobile system. First, we define multilevel logic operation (MLO), which is a new concept to deal with the multilevel logic signals. We prove that the conventional binary logic concept is a subset of the MLO concept. The multilevel logic signal can be directly controlled by using this MLO in place of the binary operation. We applied the MLO to the CDMA base station modulator (BSM) in order to reduce the hardware complexity. In the case of a 3-sectorized cell, this method helps reduce the complexity down the level of below 1% of the conventional CDMA BSM for spreading and filtering, and to 50% for Walsh covering.

  • PDF

A Study on a Single-Phase Module UPS using a Three-Arm Converter/Inverter

  • Choi Y.K.;Ko T.G.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.987-993
    • /
    • 2003
  • The module UPS can flexibly implement expansion of power system capacities. Furthermore, it can be used to build up the parallel redundant system to improve the reliability of power system operation. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. In this paper, the three-arm converter/inverter is compared with the general full-bridge and half-bridge topology from a practical point of view and chosen as the module UPS topology. The switching control approaches based on a pulse width modulation of the converter and inverter of the system are presented independently The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. Two prototype 3kVA modules are designed and implemented to confirm the effectiveness of the proposed approaches. Experimental results show that the three-arm UPS system has a high power factor, a low distortion of output voltage and input current, and good load sharing characteristic.

  • PDF

Reducing Train Weight and Simplifying Train Design by Using Active Redundancy of Static Inverters for the Onboard Supply of Rolling Stock

  • Bachmann, G.;Wimmer, D.
    • International Journal of Railway
    • /
    • v.1 no.3
    • /
    • pp.89-93
    • /
    • 2008
  • Reliability of onboard power supply systems on rolling stock is a very important issue for the railway operator. While a failure of the HVAC supply results in a loss of comfort for the passengers, a failure of the supply for air compressors or for the traction cooling systems results in towing the train. This is, looking at the required availability of a train, not acceptable. An active redundancy concept for the onboard power supply maximizes the availability of the system. This paper describes such a system under the aspect of $\cdot$ Weight reduction $\cdot$ Continuous operation when changing from normal to redundant operation $\cdot$ Flexibility in train design.

  • PDF

A Novel Redundant Binary Montgomery Multiplier and Hardware Architecture (새로운 잉여 이진 Montgomery 곱셈기와 하드웨어 구조)

  • Lim Dae-Sung;Chang Nam-Su;Ji Sung-Yeon;Kim Sung-Kyoung;Lee Sang-Jin;Koo Bon-Seok
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.16 no.4
    • /
    • pp.33-41
    • /
    • 2006
  • RSA cryptosystem is of great use in systems such as IC card, mobile system, WPKI, electronic cash, SET, SSL and so on. RSA is performed through modular exponentiation. It is well known that the Montgomery multiplier is efficient in general. The critical path delay of the Montgomery multiplier depends on an addition of three operands, the problem that is taken over carry-propagation makes big influence at an efficiency of Montgomery Multiplier. Recently, the use of the Carry Save Adder(CSA) which has no carry propagation has worked McIvor et al. proposed a couple of Montgomery multiplication for an ideal exponentiation, the one and the other are made of 3 steps and 2 steps of CSA respectively. The latter one is more efficient than the first one in terms of the time complexity. In this paper, for faster operation than the latter one we use binary signed-digit(SD) number system which has no carry-propagation. We propose a new redundant binary adder(RBA) that performs the addition between two binary SD numbers and apply to Montgomery multiplier. Instead of the binary SD addition rule using in existing RBAs, we propose a new addition rule. And, we construct and simulate to the proposed adder using gates provided from SAMSUNG STD130 $0.18{\mu}m$ 1.8V CMOS Standard Cell Library. The result is faster by a minimum 12.46% in terms of the time complexity than McIvor's 2 method and existing RBAs.

Force Fighting Suppressive Technique of Dual Redundant Asymmetric Tandem Electro-Hydrostatic Actuator for Aircraft (항공기용 이중화 비대칭형 직렬 전기-정유압 구동기의 Force Fighting 억제 기법)

  • Song, Woo Keun;Kim, Sang Seok;Choi, Jeong Seok;Lee, JungUn;Lee, Jong Cheol;Lee, Jun won;Choi, Jong Yoon
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.5
    • /
    • pp.62-69
    • /
    • 2022
  • EHA (Electro-Hydrostatic Actuator) is more energy efficiency than a centralized hydraulic system. In particular, the EHA used for aircraft has a redundant design in preparation for failure scenario. Also, due to the aircraft's internal space limitation, the actuator's length must be optimized. Therefore, a series configuration of double rod and single rod cylinder is advantageous. However, due to the asymmetry of the cross-sectional area of the piston, the force fighting phenomenon between the two cylinder areas occurs during redundant operation with a general control system. In this paper, the force fighting phenomenon of redundant EHA was simulated. A controller with load compensation and a force control-based position controller as a method to suppress its stimulation

Using SDU Slip/Slide Control (SDU 장치를 이용한 Slip/Slide 제어방안)

  • Park, Ju-Yeon;Kang, Deok-Won;Lee, Jong-Seong
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.377-383
    • /
    • 2011
  • The paper is to perceive accurately speed of the train through redundant processor operation. When Slip/slide is occurred at the axle, the train is applied brake force using the Tachometer and the Doppler sensor which assistance equipment. One of the main features of railway signaling system is that rolling stock is made stop to avoid collision with the rolling stock ahead when the rolling stock exceeds its maximum operating speed in line. In addition, in the case of the rolling stock with automatic train operation, it carries out activities such as braking and propulsion using the difference between its actual speed and target speed at the point. To perform these functions, it is essential to calculate the exact speed of the rolling stock in signaling equipment on vehicles. Train speed detection unit are composed of the Tachometer and the Doppler sensor, and speed information is sent to the SDU unit. The processor of SDU unit calculates the speed of the train using compare logic the received speed information. Even if there are Slip/Slide, signaling system is available to apply exact braking, to improve stop on position and to guarantee the safety of trains.

  • PDF

The Novel Efficient Dual-field FIPS Modular Multiplication

  • Zhang, Tingting;Zhu, Junru;Liu, Yang;Chen, Fulong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.2
    • /
    • pp.738-756
    • /
    • 2020
  • The modular multiplication is the key module of public-key cryptosystems such as RSA (Rivest-Shamir-Adleman) and ECC (Elliptic Curve Cryptography). However, the efficiency of the modular multiplication, especially the modular square, is very low. In order to reduce their operation cycles and power consumption, and improve the efficiency of the public-key cryptosystems, a dual-field efficient FIPS (Finely Integrated Product Scanning) modular multiplication algorithm is proposed. The algorithm makes a full use of the correlation of the data in the case of equal operands so as to avoid some redundant operations. The experimental results show that the operation speed of the modular square is increased by 23.8% compared to the traditional algorithm after the multiplication and addition operations are reduced about (s2 - s) / 2, and the read operations are reduced about s2 - s, where s = n / 32 for n-bit operands. In addition, since the algorithm supports the length scalable and dual-field modular multiplication, distinct applications focused on performance or cost could be satisfied by adjusting the relevant parameters.

A Study on a Single-Phase Module UPS using a Three-Arm Converter/Inverter

  • Koo, Tae-Geun;Byun, Young-Bok;Joe, Ki-Yeon;Kim, Dong-Hee;Kim, Chul-U
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.1
    • /
    • pp.44-51
    • /
    • 2003
  • The module UPS can flexibly implement expansion of power system capacities. Further-more, it can be used to build up the parallel redundant system to improve the reliability of power system operation. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. In this paper, the three-arm converter/inverter is compared with the general full-bridge and half-bridge topology from a practical point of view and chosen as the module UPS topology. The switching control approaches based on a pulse width modulation of the converter and inverter of the system are presented independently. The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. Two prototype 3㎸A modules are designed and implemented to confirm the effectiveness of the pro-posed approaches. Experimental results show that the three-arm UPS system has a high power factor, a low distortion of output voltage and input current, and good load sharing characteristics.

A New Algorithm for Boolean Function Minimization (부울함수의 간소화를 위한 새 방법)

  • 이우이
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.21 no.4
    • /
    • pp.43-51
    • /
    • 1984
  • In the case of Quine Mccluskey's methode for Boolean function minimization, we have to examine each bits of binary represented minterms. In this paper, cube relations between misterms that are represented by means of decimal number, and all sorts of rules for Boolean function minimization are described as theorems, and they are verified. And based on these theorems, the new fast algorithm for Boolean function minimization is proposed. An example of manual operation is sholvn, and the process is writed out by a FORTRAN program. In this program, the essential pl.imp implicants of the Boolean function that has 100 each of minterms including redundant minterms, are finked and printed out, (the more minterms can be treated if we take the more larger size of arrays) and the outputs are coincided with the results of manual operation.

  • PDF

SOS-Net for Generattion of PLC Program (PLC 프로그램 생성을 위한 SOS-Net)

  • Ko, Min-Suk;Hong, Sang-Hyun;Wang, Gi-Nam;Park, Sang-Cheul
    • Korean Journal of Computational Design and Engineering
    • /
    • v.14 no.1
    • /
    • pp.60-68
    • /
    • 2009
  • Because of the reduced product life-cycle, industries are making an effort to bring down the process planning time. In the traditional approach, we have to analyze established process planning, then design the time chart based on process information and drawing the formal time chart such as SOP(sequence of operation). Thereafter, it will be converted to PLC code that is a time consuming and redundant job. Similarly, Industrial automated process uses PLC Code to control the factory; however, control information and control code(PLC code) are difficult to understand. Hence, industries prefer writing new control code instead of using the existing one. It shows the lack of information reusability in the existing process planning. As a result, to reduce this redundancy and lack of reusability, we propose SOS-Net modeling method. Unlike past stabilized process planning that is rigid to any change; our proposed SOS-Net modeling method is more adaptable to the new changes. The SOS-Net model is easy to understand and easy to convert into PLC Code accordingly. Therefore, we can easily modify the control information and reuse it for new process planning. The proposed model plays an intermediary role between process planning and PLC code generation. It can reduce the process planning and implementation time as well as cost.