• Title/Summary/Keyword: Reduction device

Search Result 1,286, Processing Time 0.03 seconds

Design of the Open-Loop Combined Meandered-Line 1-Layer Radiator for Diversity Antennas with Size-Reduction and Improved Isolation (다이버시티 안테나의 소형화와 격리도 향상을 위한 미앤더 선로와 개방형 루프가 결합된 방사구조의 설계)

  • Mok, Se-Gyoon;Kahng, Sung-Tek;Kim, Yong-Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.110-116
    • /
    • 2012
  • This paper proposes a new diversity antenna which is the base of MIMO, tunable and reconfigurable antennas. The antenna has a small size and high inter-antenna isolation resulting from the compact radiating element comprising a meandered line and an open-loop combined in one limited uniplanar space and a modified T-shaped decoupling structure, respectively. In a WiMAX band, the radiating element and the entire antenna are $0.092{\lambda}$ and $0.2216{\lambda}$ in size, which shows effective size-reduction and the gain and efficiency of the proposed antenna attached to the ground of a handheld device are 3.7dBi and 56% acceptable to the industrial standard.

Discontinuous PWM Scheme for Switching Losses Reduction in Modular Multilevel Converters

  • Jeong, Min-Gyo;Kim, Seok-Min;Lee, June-Seok;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1490-1499
    • /
    • 2017
  • The modular multilevel converter (MMC) is generally considered to be a promising topology for medium-voltage and high-voltage applications. However, in order to apply it to high-power applications, a huge number of switching devices is essential. The numerous switching devices lead to considerable switching losses, high cost and a larger heat sink for each of the switching device. In order to reduce the switching losses of a MMC, this paper analyzes the performance of the conventional discontinuous pulse-width modulation (DPWM) method and its efficiency. In addition, it proposes a modified novel DPWM method for advanced switching losses reduction. The novel DPWM scheme includes an additional rotation method for voltage-balancing and power distribution among sub modules (SMs). Simulation and experimental results verify the effectiveness and performance of the proposed modulation method in terms of its switching losses reduction capability.

Seismic Performance and Vibration Control of Urban Over-track High-rise Buildings

  • Ying, Zhou;Rui, Wang;Zengde, Zhang
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.3
    • /
    • pp.207-219
    • /
    • 2022
  • During the structural design of urban over-track high-rise buildings, two problems are most likely encountered: the abrupt change of story stiffness between the podium and the upper towers, as well as the demand for train-induced vibration control. Traditional earthquake-resistant structures have to be particularly designed with transfer stories to meet the requirement of seismic control under earthquakes, and thus horizontal seismic isolation techniques are recommended to solve the transfer problem. The function of mitigating the vertical subway-induced vibration can be integrated into the isolation system including thick rubber bearings and 3D composite vibration control devices. Engineering project cases are presented in this paper for a more comprehensive understanding of the engineering practice and research frontiers of urban over-track high-rise buildings in China.

Reduction of the Femoral Head First, and Assembly of the MUTARS® Device in Case of Impossible Reduction during Total Hip Arthroplasty

  • Jee Young Lee;Ye Jun Lee;Gyu Min Kong
    • Hip & pelvis
    • /
    • v.35 no.4
    • /
    • pp.277-280
    • /
    • 2023
  • Dislocation after a total hip arthroplasty occurs in approximately 1% of patients; however, the frequency is much higher after revision surgery. To prevent dislocation, use of a larger femoral head is recommended, and a dual mobility femoral head has been introduced. However, reducing the dual mobility femoral head to the acetabular component is difficult in cases involving contracture in the soft tissue around the joint. A 72-year-old male patient who developed a periprosthetic joint infection underwent two-stage revision surgery using MUTARS®. Two months after the revision, the hip joint became dislocated and manual reduction was attempted; however, dislocation occurred again. During another revision using a dual mobility bearing, the soft tissue around the hip joint was too tight to reduce. The problem was overcome by first repositioning the dual mobility head into the acetabular socket, followed by assembly of the diaphyseal portion of the implant.

Evaluation of Lubrication Performance by Laser Texturing Surface Treatment Patterns through Ring Compression Tests (링 압축 시험을 이용한 레이저 텍스처링 표면처리 패턴별 윤활성능 평가)

  • J. S. Choi;W. J. Song
    • Transactions of Materials Processing
    • /
    • v.33 no.4
    • /
    • pp.291-300
    • /
    • 2024
  • To compare the lubrication performance improvement of different laser texturing surface treatment patterns, ring-shaped specimens were prepared by processing line and dot patterns using a fiber laser device. Ring compression tests were conducted to compare the reduction rates of the inner diameter corresponding to the same height reduction of the specimens. Laser processing conditions were set to create patterns with a depth of 9㎛ and a width of 45㎛. Ring specimens were processed with varying spacings between dots and lines. The forging lubricant TECTYL FORM CF 351S was uniformly applied to the upper and lower compression tools, and the rings were compressed by 40% using a hydraulic press, after which the inner diameter was measured. The comparison of inner diameter reduction rates indicated that pattern processing improves lubrication performance, with line patterns being more effective than dot patterns in enhancing lubrication performance.

A Study on Vibration & Noise Reduction of Fast Back Feeding Device for Manufacturing Process (제조공정용 Fast Back 이송장치 진동·소음 저감에 관한 연구)

  • Han, Doo-Hee;Lee, Seung-Hun;Son, Yung-Deug
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.642-648
    • /
    • 2019
  • This paper presents a fast back-type transfer device for snack food processing that uses the inertia of transferred material. A conventional conveying system is a drive system that uses a belt conveyor and mechanical crank, which generate noise and vibration and cause environmental pollution. Vibration and noise are reduced in the proposed fast back feeding device by using a counterweight. The crank drive unit was replaced with a linear servomotor, and an equilibrium device was designed to balance the force due to acceleration. This makes it is possible to adjust the forward and backward speed and acceleration through PLC control. A vibration damper device offsets the vibration force of the periodic shock form. The main cause of the vibration was identified through vibration analysis, and reduction measures were established. We verified the effectiveness of the vibration by making a prototype and performing about 10 vibration tests. Because no mechanical transducer is needed, energy loss, noise, and vibration do not occur, and the operating speed is not limited.

The study on the parallel operation of phase winding in the SR Drive for Electrical Vehicle Applications (전기자동차용 SRM의 상권선 병렬에 관한 연구)

  • Hong J.P.;Park S.J.;Won T.H.;Kwon S.J.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.115-120
    • /
    • 2003
  • In a motor driving, the current rate is directly related to the rate of a switching device and in cost reduction, the parallel switching operation is the alternatives because it has the smaller current rate through current division. There are many investigations for the parallel switching operations to equaling the current division. However it remains many problems for practical usage. The reason is that the switching characteristics are mainly relied on the different saturation voltage of each device etc. and these factors are not altered by circuit designer. In order to compensate this problem, a proper resistance is experimently inserted to the switching device. But this method can not be the optimal solution. Therefore this paper proposes a new parallel operation which uses a parallel phase winding to remove the traditional effect of switching device such as saturation voltage according to the division of current. Also the reliable and stable driving is improved through experiments and the detailed principles.

  • PDF

A 5-GHz Band CCNF VCO Having Phase Noise of -87 dBc/Hz at 10 kHz Offset

  • Lee, Ja-Yol;Lee, Sang-Heung;Kang, Jin-Young;Kim, Bo-Woo;Oh, Seung-Hyeub
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.3
    • /
    • pp.137-142
    • /
    • 2004
  • In this paper, we present a new current-current negative feedback(CCNF) differential voltage-controlled oscillator (VCO) with 1/f induced low-frequency noise suppressed. By means of the CCNF, the 1/f induced low-frequency noise is removed from the proposed CCNF VCO. Also, high-frequency noise is stopped from being down-converted into phase noise by means of the increased output impedance through the CCNF and the feedback capacitor $C_f. The proposed CCNF VCO represents 11-dB reduction in phase noise at 10 kHz offset, compared with the conventional differential VCO. The phase noise of the proposed CCNF VCO is measured as - 87 dBc/Hz at 10 kHz offset frequency from 5.5-GHz carrier. The proposed CCNF VCO consumes 14.0 mA at 2.0 V supply voltage, and shows single-ended output power of - 12 dBm.

Treatment for Giant Fusiform Aneurysm Located in the Cavernous Segment of the Internal Carotid Artery Using the Pipeline Embolization Device

  • Oh, Se-Yang;Kim, Myeong Jin;Kim, Bum-Soo;Shin, Yong Sam
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.1
    • /
    • pp.32-35
    • /
    • 2014
  • The pipeline embolization device (PED) is a new endovascular device for treatment of complex, fusiform and wide-neck intracranial aneurysms. The main mechanism of this stent is to divert the flow in the parent artery with reduction of inflow in the aneurysm leading to thrombosis. We treated a 40-year-old woman who had left facial pain and orbit discomfort. Angiography showed a giant fusiform aneurysm located in the cavernous segment of the left internal carotid artery. A PED was successfully deployed across the aneurysm. The procedure and post-procedural course were uneventful. After 3 months, angiography showed complete obliteration of the aneurysm with good patency of the branching vessels originating from the deployed segment. The patient's symptoms improved completely without complications.

Enhancing Lifetime of White OLED Device by Minimizing Operating Voltage Increase

  • Lee, Sung-Soo;Choi, Jun-Ho;Ha, Jae-Kook;Lee, Sang-Pil;Kim, Seong-Min;Choi, Ji-Hye;Lee, Soo-Yeon;Kim, Hyo-Seok;Chu, Chang-Woong;Shin, Sung-Tae;Kim, Chi-Woo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1658-1660
    • /
    • 2007
  • We fabricate green device having unique life time characteristics of operating voltage reduction with time, ${\Delta}V_{op}$ <0. A green device needs lower voltage than initial voltage for sustaining constant current as life time goes on. It means there are two possible reasons; one is interface modification between anode and HIL due to oxygen plasma treatment and the other is bulk property modification due to combination of new green host and new green dopant. From these materials and oxygen plasma treatment, we can make white OLED device having the characteristics of low ${\Delta}V_{op}$ increasing.

  • PDF