• 제목/요약/키워드: Recovery voltage measurement

검색결과 22건 처리시간 0.027초

저압 배선용차단기 절연회복특성 파악을 위한 절연회복전압 측정기법 연구 (Study on Measurement Method of Dielectric Recovery Voltage to analysis Dielectric Recovery Characteristic of Molded Case Circuit Breaker)

  • 송태헌;조영만;고광철
    • 조명전기설비학회논문지
    • /
    • 제29권8호
    • /
    • pp.49-54
    • /
    • 2015
  • Molded Circucit Breaker(MCCB) is a most widely used device to protect loads from the over-current in low power level distribution system. When the MCCB interrupts the over-current, the arc discharge occurred between fixed contact and moving contact to create hot gas. By the Lorentz force due to arc current, the occurred arc is bent to the grids. The grids extend and cool and divide it for arc extinguish. In the majority cases, the MCCB protects loads by interrupting the over-current successfully but in some cases the re-ignition is occurred by hot-gas created during process of interruption. The re-ignition arises when the recovery voltage(RV) is more higher than the recovery strength between contacts and it leads to interruption fault. Therefore to find out the dielectric recovery characteristics of protecting device has a great importance for preventing interruption fault. In this paper, we studies measurement method of the dielectric recovery characteristics considering inherent attribute of the MCCB. To measure the dielectric recovery characteristic of MCCB, we makes an experiment circuit for applying the over-current and the randomly recovery voltage. The measurement methode to find out the dielectric recovery voltage of the MCCB was established and the result was based on experiment results.

Implementing a Dielectric Recovery Strength Measuring System for Molded Case Circuit Breakers

  • Cho, Young-Maan;Rhee, Jae-ho;Baek, Ji-Eun;Ko, Kwang-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1752-1758
    • /
    • 2018
  • In a low-voltage distribution system, the molded case circuit breaker (MCCB) is a widely used device to protect loads by interrupting over-current; however the hot gas generated from the arc discharge in the interrupting process depletes the dielectric recovery strength between electrodes and leads to re-ignition after current-zero. Even though the circuit breaker is ordinarily tripped and successfully interrupts the over-current, the re-ignition causes the over-current to flow to the load again, which carries over the failure interruption. Therefore, it is necessary to understand the dielectric recovery process and the dielectric recovery voltage of the MCCB. To determine these characteristics, a measuring system comprised of the experimental circuit and source is implemented to apply controllable recovery voltage and over-current. By changing the controllable recovery voltage, in this work, re-ignition is driven repeatedly to obtain the dielectric recovery voltage V-t curve, which is used to analyze the dielectric recovery strength of the MCCB. A measuring system and an evaluation technique for the dielectric recovery strength of the MCCB are described. By using this system and method, the measurement to find out the dielectric recovery characteristics after current-zero for ready-made products is done and it is confirmed that which internal structure of the MCCB affects the dielectric recovery characteristics.

Recovery Voltage Measurements of Oil-immersed Transformer

  • Li, Ming-Hua;Dong, Ming;Qu, Yan-Ming;Yan, Zhang
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권5호
    • /
    • pp.230-234
    • /
    • 2006
  • One of the methods currently being investigated as a possible non-intrusive diagnostic tool for condition monitoring of power transformer and cable is the recovery voltage measurement, which will be improving the ability to detect the content of water concentration and the ageing process in the insulation system and may thus be an indicator of insulation quality and its ageing status. The polarization phenomenon was studied using RVM with oil-paper samples. In order to interpret its mechanism, the Extended Debye model was introduced. With different circuit parameters, various simulation results were gotten. Furthermore, with the test samples of different ageing condition, measurements are accomplished in the lab. On the basis of this experiment as well as theoretical analysis, correlations between polarizations and ageing were analyzed.

양성자 주입기술을 이용한 PT형 전력다이오드의 스위칭 특성 향상 (Switching Characteristics Enhancement of PT Type Power Diode using Proton Irradiation Technique)

  • 김병길;최성환;이종헌;배영호
    • 한국전기전자재료학회논문지
    • /
    • 제19권3호
    • /
    • pp.216-221
    • /
    • 2006
  • Lifetime control technique by proton implantation has become an useful tool for production of modern power devices. In this work, punch-through type diodes were irradiated with protons for the high speed power diode fabrication. Proton irradiation which was capable of controlling carrier's lifetime locally was carried out at the various energy and dose conditions. Characterization of the device was performed by current-voltage, capacitance-voltage and reverse recovery time measurement. We obtained enhanced reverse recovery time characteristics which was about $45\;\%$ of original device reverse recovery time and about $73\;\%$ of electron irradiated device reverse recovery time. The measurement results showed that proton irradiation technique was able to effectively reduce minority carrier lifetime without degrading the other characteristics.

회복전압 측정을 위한 DAQ 프로그램 (A Data Aquisition program for recovery voltage measurement)

  • 이세현;최태식;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.31-34
    • /
    • 2007
  • 회복전압 측정법(RVM: Recovery voltage measurement)은 최근 유럽지역에서 활발히 연구 진행되고 있는 절연 진단 기법 중의 하나로 소개된바 있으며, 오일과 절연지 사이에 스며든 수분량을 검출할 수 있는 진단 시스템기법이다. 변압기 내부의 절연물질에 대한 분극특성을 분석함으로서 열화진행정도 및 열화정도를 진단하는데 활용될 수 있다. 본 논문은 국산화의 일환으로 전기계측제어용 LabVIEW 프로그램을 활용하여 RVM 전 과정을 자동으로 사용할 수 있도록 자체 제작한 프로그램을 소개하고자 한다.

  • PDF

신호용 PEAK 전압 정밀검출에 관한 연구 (A Study on Accuracy Detection Method for Signal Peak Voltage)

  • 박호철;성형수;한승문;한정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2528-2530
    • /
    • 2000
  • In general, Diode makes a major role in electronic circuit. For example, switching of rectifier, cross current of switching rectifier, energy transfer of electronic element and reverse charge of capacitor, voltage insulation, energy feedback from load to power supply, and such as recovery of storaged energy. Generally, We regard power diode as ideal element, but it has a certain boundary actually, specially, We use diode for detecting circuit peak hold voltage signal. It has cut in voltage. It occurs error of measurement value namely. This error, below in region diode voltage drop (0.7v) measurement value is wholesome signal, Specially, We can not get precision data. Therefore, precision level is low between theoretical and measurement data because of error in actual circuit. Conclusionally, In this paper, We define the error concerning to the power diode characteristics which is used detecting of the minute signal, and recommend the method that minimize measurement error.

  • PDF

Karl-Fischer법과 회복전압법을 이용한 수분량 검출 비교 특성 (Measurement of Moisture Contents using Recovery Voltage Method and Karl-Fischer Method)

  • 김형민;김재훈;김주한;한상옥;이세현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 전기설비
    • /
    • pp.76-78
    • /
    • 2005
  • Moisture contents measurement is frequently used as one of parameters for degradation diagnosis of transformer insulation. In general Karl-Fisher method is mainly used for moisture contents till now. But this method is inconvenient because of dismounting transformer for sampling oil or paper, and also partial sampling. At latest Recovery Voltage Method(RVM) is noticed for complement of this method. RVM can directly estimate moisture contents of transformer insulations in field without dismounting transformer. In this paper the accelerated aging process of oil-paper samples have been investigated at a temperature up to 140$^{\circ}C$ for 500 hours. The oil-paper insulation samples have been measured at intervals of 100 hours. Next to, we have estimated moisture contents using both Karl-Fisher Titration Method and RVM. And we have compared with Karl-Fisher Titration Method and RVM for estimating moisture contents. At last we have verified reliability of RVM which is new measurement method.

  • PDF

열회수장치에 의한 열교환 성능 분석(농업시설) (Analysis of Heat Exchanging Performance of Heat Recovering Device Attached to Exhaust Gas Duct)

  • 서원명;강종국;윤용철;김정섭
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.333-339
    • /
    • 2000
  • This study was performed to investigate the performance of heat recovery device attached to exhaust gas funnel connected to combustion chamber of greenhouse heating system. The experiment heat recovery system is mainly consisted of LPG combustion chamber and two heat recovery units; unit-A is attached directly to the exhaust gas funnel, and unit-B is connected with unit-A. Heat recovery performance was evaluated by estimating total energy amount by using enthalpy difference between two measurement points together with mass flow rate of gas and/or air passing through each heat recovery unit depending on 5 different flow rates controlled by voltage meter. The results of this experimental study, such as heat exchange behavior of supply air pipes and exhaust air passages crossing the pipes, pressure drop between inlet and outlet, heat recovery performance of exchange unit, etc., will be used as fundamental data for designing optimum heat recovery device to be used for fuel saving purpose by reducing heat loss amounts mostly wasted outside of greenhouse through funnels.

  • PDF

모터부하를 고려한 상정사고 발생 시 저전압 부하차단 적용 방안에 대한 연구 (A Study on the Application of Under Voltage Load Shedding Scheme in Line Contingency considering Motor Load)

  • 이윤환
    • 전기학회논문지P
    • /
    • 제66권1호
    • /
    • pp.21-26
    • /
    • 2017
  • Failure of high-voltage transmission line, which is responsible for large-scale power transmission, can be reason for system voltage instability. There are many methods to prevent voltage instability like adjustment of equipment, the generator voltage setting, and load shedding. Among them, the load shedding, have a problem of economic loss and cascading effect to power system. Therefore, the execution of load shedding, amount and timing is very important. Conventionally, the load shedding setting is decided by the preformed simulation. Now, it is possible to monitor the power system in real time by the appearance of PMU(Phasor Measurement Unit). By this reason, some of research is performed about decentralized load shedding. The characteristics of the load can impact to amount and timing of decentralized load shedding. Especially, it is necessary to consider the influence of the induction motor loads. This paper review recent topic about under voltage load shedding and compare with decentralized load shedding scheme with conventional load shedding scheme. And simulations show the effectiveness of proposed method in resolving the delayed voltage recovery in the Korean Power System.

양성자 주입 기술을 이용한 초고속 회복 다이오드의 제작 (Fabrication of Ultra Fast Recovery Diodes using Proton Irradiation Technique)

  • 이강희;김병길;이용현;백종무;이재성;배영호
    • 한국전기전자재료학회논문지
    • /
    • 제17권12호
    • /
    • pp.1308-1313
    • /
    • 2004
  • Proton irradiation technology was used for the improvement of power diode switching characteristics. Proton irradiation was carried out at the energies of 2.32 MeV, 2.55 MeV, 2.97 MeV so that the projection range of irradiated proton would be at the metallurgical junction, depletion region and neutral region of pn diode, respectively. Dose conditions were varied into three conditions of 1${\times}$10$^{11}$ cm$^{-2}$ , 1${\times}$10$^{12}$ cm$^{-2}$ , 1${\times}$10$^{13}$ cm$^{-2}$ at each condition of energies. Characterization of the device was performed by I-V(current-voltage), C-V(capacitance-voltage) and trr(reverse recovery time) measurement. At the optimum condition of irradiation, the reverse recovery time of device has been reduced about 1/5 compared to that of original un-irradiated device.