• Title/Summary/Keyword: Receiving inspection

Search Result 41, Processing Time 0.019 seconds

Destructive Test to Ensure Integrity of Composite Structure (파괴시험을 통한 복합재 구조물의 건전성 입증)

  • Yang, Hyun-Deok;Jeong, Duck-Young;Lee, Kyung-Cheol;Jin, Young-Kwon
    • Aerospace Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.230-236
    • /
    • 2007
  • The quality control of composite structure includes inspection, testing and monitoring in all processes from receiving inspection to part fabrication. The purpose of these activities is to ensure that the design objectives are consistently achieved. The quality factors include material, receiving inspection, storage and shelf-life control, environmental control, testing, inspection and record control. This paper presents the process verification method using destructive test and quality control method in composite structure of aircraft. And it is believed that the destructive test will be basis to obtain a reliability of non-destructive test in complex composite structure and to ensure the design requirements in composite part.

  • PDF

Feasibility Analysis of Rapid Quality Evaluation Method for Blast Furnace Slag Using Hydrometer (Hydrometer를 이용한 고로슬래그 미분말의 분말도 품질 신속평가 가능성 분석)

  • Han, Cheon-Goo;Joo, Eun-Hui
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.1
    • /
    • pp.43-49
    • /
    • 2018
  • The aim of the research is to analyze the feasibility of rapid quality evaluation method for blast furnace slag using hydrometer based on the former research of the prediction method for concrete compressive strength using hydrometer. Using this method, it is expected to provide a new application for blast furnace slag quality evaluation easily and rapidly during the receiving inspection. According to the experimental results, the settling time period of hydrometer was delayed with increased fineness of blast furnace slag. By using the regression equation of y = 198 120 x - 193 936(R=0.9398) obtained from the correlation between density of suspension at three minutes and fineness, it was possible to evaluate the quality of blast furnace slag fineness rapidly. Therefore, for ready-mixed concrete receiving inspection, the suggested method can be used as a cheap, a simple, and a rapid inspection method.

Transition Control of Standby and Operation Modes of Wireless Charging System for Inspection Robots

  • Liu, Han;Tan, Linlin;Huang, Xueliang;Czarkowski, Dariusz
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.691-701
    • /
    • 2019
  • To solve the problems in the contact charging of inspection robots, a wireless charging system for inspection robots and a control strategy are introduced in this paper. Circuit models of a wireless power system with a compound compensation circuit and a three-phase Class-D resonant inverter are set up based on circuit theory. An output voltage control method based on the equal spread regulation of the phase difference between adjacent phases and the parameter correction method in the primary compound compensation circuit are proposed. The dynamic characteristics of the key parameters varying with the secondary coil position are obtained to further investigate the adaptive location scheme during the access and exit processes of moving robots. Combining the output voltage control method and the adaptive location scheme, a transition control strategy for the standby and operation modes of the wireless charging systems for inspection robots is put forward to realize the system characteristics including the low standby power in the standby mode and the high receiving power in the operation mode. Finally, experiments are designed and conducted to verify the correctness of the theoretical research.

Accuracy Analysis of Road Surveying and Construction Inspection of Underpass Section using Mobile Mapping System

  • Park, Joon Kyu;Um, Dae Yong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.2
    • /
    • pp.103-111
    • /
    • 2021
  • MMS (Mobile Mapping System) is being used for HD (High Definition) map construction because it enables fast and accurate data construction, and it is receiving a lot of attention. However, research on the use of MMS in the construction field is insufficient. In this study, road surveying and inspection of construction structures were performed using MMS. Through data acquisition and processing using MMS, point cloud data for the study site was created, and the accuracy was evaluated by comparing with traditional surveying methods. The accuracy analysis results showed a maximum of 0.096m, 0.091m, and 0.093m in the X, Y, and H directions, respectively. Each RMSE was 0.012m, 0.015m, and 0.006m. These result satisfy the accuracy of topographic surveying in the general survey work regulation, indicating that construction surveying using MMS is possible. In addition, a 3D model was created using the design data for the underpass road, and the inspection was performed by comparing it with the MMS data. Through inspection results, deviations in construction can be visually confirmed for the entire underground roadway. The traditional method takes 6 hours for the 4.5km section of the target area, but MMS can significantly shorten the data acquisition time to 0.5 hours. Accurate 3D data is essential data as basic data for future smart construction. With MMS, you can increase the efficiency of construction sites with fast data collection and accuracy.

A Study on the Validation of Measured Data from the Seismic Accelerometers in the Safety Evaluation System of Public Buildings (공공건축물 안전성 평가를 위한 지진가속도 계측자료의 유효성 검증 방법에 대한 연구)

  • Jang, Won-Seok;Jeong, Seong-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.150-157
    • /
    • 2020
  • In this study, an algorithm was developed to validate the seismic acceleration measurement data of the seismic acceleration measurement system using measurement data from public buildings currently in operation. Through the results of the study, an algorithm was developed to detect errors and abnormalities in the measurement data itself and the process of generating real-time data (MMA/sec) and event measurement data (MiniSEED), which are the main data generated by the system, and the basic data for determining the direction of inspection through measurement data analysis. It is expected that this will be used as a guideline to determine whether or not the seismic acceleration measurement system, which was managed as receiving/not receiving, is inspected and abnormal types of conditions.

Procedure of Seismic Performance Evaluation of LNG Receiving Terminal Facilities (천연가스 생산기지 시설물의 내진성능평가 절차)

  • Lee, Tae-Hyung;Lee, Eunsuk;Park, Taekyu;Hong, Seong Kyeong;Kim, Joonho
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.110-115
    • /
    • 2014
  • It is crucial for important facilities to withstand strong earthquakes because their damage may cause undesirable socio-economic effect. A liquefied natural gas (LNG) receiving terminal is one of the lifeline facilities whose seismic safety needs to be guaranteed. Even though all operating LNG receiving terminals in Korea were seismically designed, old design codes do not guarantee to comply with the current seismic design codes. In addition, if the constructional materials have been deteriorated, the seismic capacity of facilities may be also deteriorated. Therefore, it is necessary that the seismic performance of LNG receiving terminals is evaluated and the facilities that lack of seismic capacity have to be rehabilitated. In this paper, a procedure of seismic performance evaluation of such facilities is developed such that the procedure consists of three phases, namely pre-analysis, analysis, and evaluation phases. In the pre-analysis phase, design documents are reviewed and walk-on inspection is performed to determine the current state of the material properties. In the analysis phase, a structural analysis under a given earthquake or a seismic effect is performed to determine the seismic response of the structure. In the evaluation phase, seismic performance of the structure is evaluated based on limit states. Two of the important facilities, i.e. the submerged combustion vaporizer (SMV) and pipe racks of one of the Korean LNG receiving terminals are selected and evaluated according to the developed procedure. Both of the facilities are safe under the design level earthquake.

Damage Detection in a Plate Using an Orientation-adjustable Magnetostrictive Transducer (조향 자기변형 트랜스듀서를 이용한 평판 결함진단)

  • Cho, Seung-Hyun;Lee, Ju-Seung;Sun, Kyung-Ho;Kim, Yoon-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.1 s.94
    • /
    • pp.81-86
    • /
    • 2005
  • In this work, we propose a new ultrasonic damage inspection method in plate structures. The proposed method employs an OPMT(orientation-adjustable patch-type magnetostrictive transducer) in order to make the ultrasonic waves directed to a specific target point. For experiments, virtual grid points were set up at every 50 mm in an aluminum plate and two OPMTs were used for inspection. If there exists a crack in a plate, the reflected Lamb wave from the crack is measured in addition to the direct waves from the transmitting transducer to the receiving transducer.

Nondestructive Evaluation of plate structures using the Ultrasonic Transducer OPMT (OPMT 초음파 트랜스듀서를 이용한 평판구조 이상진단)

  • Kim, Yoon-Young;Cho, Seung-Hyun;Lee, Ju-Seung;Sun, Kyung-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.423-427
    • /
    • 2004
  • In this work, we propose a new ultrasonic damage inspection method in plate structures. The proposed method employs an OPMT (Orientation-adjustable Patch-type Magnetostrictive Transducer) in order to make the ultrasonic waves focused on the specific target point. For experiments, virtual grid points were set up at every 50 mm in an aluminum plate and two OPMTs were used for inspection. If there exists a crack in a plate, the reflected Lamb wave from the crack is measured in addition to the direct waves from the transmitting transducer to the receiving transducer.

  • PDF

Automatic TFT-LCD Mura Defect Detection using Gabor Wavelet Transform and DCT (가버 웨이블렛 변환 및 DCT를 이용한 자동 TFT-LCD 패널 얼룩 검출)

  • Cho, Sang-Hyun;Kang, Hang-Bong
    • Journal of Broadcast Engineering
    • /
    • v.18 no.4
    • /
    • pp.525-534
    • /
    • 2013
  • Recently, mura defect inspection techniques are receiving attention in LCD production procedure since demands of TFT-LCD are growing. In this paper, we propose an automatic mura defect inspection method using gabor wavelet transform and DCT. First, we generate a reference panel image using DCT based method. For original panel image and generated reference panel image, we apply a gabor wavelet transform to eliminate texture information in images. Then, we extract mura defect regions from the difference image between gabor wavelet transform image of original panel and generated reference panel image. Finally, all mura defect regions are quantified to detect accurate mura defects. Experimental results show that our method is more accurate and efficient than previous methods.

A Study for the Health Education of Breast Self-Examination (유방자가검진 교육을 위한 조사 연구)

  • Lee, Young Whee
    • Korean Journal of Adult Nursing
    • /
    • v.12 no.4
    • /
    • pp.717-726
    • /
    • 2000
  • This study was undertaken to examine the degree of knowledge and compliance of breast self-examination with women. The subjects for this study were 474 women aged 35-65 receiving health examination from Yonsu-ku Public Health Service Center in Inchon. Data collection was conducted through the use of 2 questionnaires. Analysis of the data was done by used of descriptive statistics, t-test, ANOVA, and Pearson Product Moment Correlation Coefficient. The results of this study were as follows: 1. There were significant differences in the breast self-examination compliance rate according to age(F=5.82, p=.000), marital status(F=2.67, p=.047), educational level (F=5.83, p=.000) and household income (F=3.41, p=.018). 2. The correct answer rate for each items of breast self-examination knowledge scale was between 14.1% of a minimum rate and 65.0% for a maximum rate of 100. The degree of knowledge for relation of breast cancer and menopause, the time of the highest occurance of breast cancer, the best time of breast self-examination and inspection methods of breast self-examination shows relatively low understanding. 3. The average score of breast self-examination was 1.34 from a maximum score of 6. The score of breast self-examination with palpation methods was higher than with inspection methods. 4. A positive correlation was found between breast self-examination knowledge and compliance rate (r=.417, p=.001). According to the results, it is necessary to provide knowledge of the relationship of breast cancer and menopause, the time of the highest occurance of breast cancer, and the best time of breast self-examination and inspection methods of breast self-examination. Also, it is necessary to provide detail guidance for inspection methods and develop a program for promoting the compliance of breast self-examination.

  • PDF