• Title/Summary/Keyword: Receiving area

Search Result 515, Processing Time 0.031 seconds

The Electric Service Reliability Investigation of the large Customers (대수용가 공급 신뢰도 조사)

  • Hong, Soon-Hak
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.154-156
    • /
    • 1987
  • An important aspects of power system design involves consideration of service reliability requirements of load to be supplied and service reliability provided by any proposed system. This paper shows the investigation of the 1984 KEPCO service reliability to the large electric consumer whose contracted maximum demand is over 500 kw. 68 customers of the total 111 investigated are located in Myungdong area and Yuido in Seoul. Of the customers are included hotel Lotte, Giobo and Seoul national University Hospital. The average service reliability of Myungdong area customers is 316min/yr/customer and about 7 times/yr/customer, and 160 min, 6 times for Yuido. Which the service reliability the interruption and the interruption frequency which caused by the customers receiving facilities were showed. The investigation is telling that the service reliability of the underground distribution area are very superior to the other area reliability. The investigated reliability seem not appropriate to be improved by change of distribution System as well as equipments and facilities improvement in the near future.

  • PDF

A Study on Magnetic Field Distribution Characteristics for Remote Field Area (리모트 필드 영역에서의 자계 분포특성에 관한 연구)

  • Kim, S.K.;Lee, E.U.;Lim, S.S.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.312-314
    • /
    • 2000
  • The electric wave propagation characteristics of electromagnetic field by induction current shows a nonlinear distinction in the metal but linear on air. This paper is written about the magnetic transmission distinction in the metalic tube, which wrapped the center axis by the same direction. The electromagnetic field made by the transmission signal is transferred from the transmission coil area toward the receiving coil by the magnetic diffusion. So, it is different magnetic flux around the coil with one in the remote field area. Analyzing such a complex magnetic characteristic, we verified this theory by the vector analysis and presented eddy current mechanism and analytical model about magnetic distribution in the remote field area. This magnetic distribution rate in metal body will be very useful in the nondestructive inspection of the eddy current in remote field which is recently rising as a new technology.

  • PDF

Implementation of an Earthquake Alarming System Based on Acceleration Monitoring at Coastal LNG Receiving Terminals (해안 천연가스 인수기지에 대한 가속도 계측 기반의 지진경보 시스템 구축)

  • Sun, Chang-Guk;Jung, Byung-Sun;Kim, Joon-Ho;Hong, Seong-Kyeon;Kim, Ki-Seog
    • The Journal of Engineering Geology
    • /
    • v.20 no.3
    • /
    • pp.339-348
    • /
    • 2010
  • As part of preparing for future earthquakes near three LNG receiving terminals located in coastal regions of Korea, acceleration monitoring systems were installed at four free field sites and on a pile foundation beneath a storage tank in a receiving terminal. Several equipments and accessories were devised to successfully install and operate the monitoring system at LNG receiving terminals. Synthetic earthquake-alarming software systems designed for decisionmaking, based on peak ground acceleration computed using the measured data, were developed for rapid response during earthquakes, not only in each local terminal area but also in the central control division. In addition, a framework software linking nationwide data on peak ground accelerations was included in the integrated earthquake alarming system in the central division, for various future applications. The earthquake alarming systems developed in this research for LNG receiving terminals, based on acceleration monitoring, represent a useful framework for industrial facilities located in coastal regions, where geotechnical conditions may show marked spatial variations.

Service analysis and propagation measurement for DGPS land-based reference station in Korea (국내 DGPS 내륙 기준국 전파 측정 및 서비스 분석)

  • Jeon, Joong Seong;Kim, Young Wan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.437-443
    • /
    • 2014
  • Based on the radio wave propagation measurement of DGPS land-based reference stations, the DGPS service coverage and signal quality in the receiving points are analyzed in this paper. The DGPS signal strength and SNR in the receiving point are measured in the winter and summer season, respectively. In case of DGPS reference station that can not provide the designed service coverage, the solution to improve the service coverage is presented in this paper. Almost all DGPS reference station except reference station with low ground conductivity or mountainous terrain provide the DGPS service coverages of 80% or more of the designed service area. The service coverages of DGPS reference stations can be improved to pre-designed service area in case of installation management of DGPS site on the plain terrain and good ground conductivity. It is necessary to get the high efficiency of transmitting antenna to improve the service area.

Solar Cell Design for Large Area Multi Busbar Module Power Loss Reduction (대면적 Multi busbar 모듈 전력 손실 저감을 위한 태양전지 설계)

  • Juhwi Kim;Jaehyeong Lee
    • Current Photovoltaic Research
    • /
    • v.11 no.1
    • /
    • pp.34-37
    • /
    • 2023
  • Solar energy had become the main energy industry of renewable energy along with hydroelectric power generation. One of the technologies that contributed to the popularization of photovoltaic power and the decrease in the unit price of photovoltaic modules was the large-area solar cell. However, as the area increased, the light receiving area increased and the current value increased accordingly. Since power loss occurs when the current value was large, the number of busbar was increased to increase the current collection rate, and a technology to lower the current value through half-cutting was developed. The bus bar of the solar cell served as a passage through which the generated current was transmitted. This was because when the number of busbar decreases, the moving distance of electrons increased, so the amount of power generation decreases and when it increases, shadows occured. An important aspect of the electrode design was the optimal balance of these busbars and number of fingers. Therefore, in this study, the characteristics of the solar cell according to the number of front bus bars of the large-area solar cell were simulated using Griddler 2,5 pro. After selecting the number of busbar with the best characteristics, the difference was compared by varying the number of fingers and a better direction for the number of cutting was presented.

Torsional Elastic Waves Propagating in a Periodically-Nonuniform Circular Rod (주기적으로 불균일한 원형막대에서 전파하는 비틂 탄성파)

  • 김진오
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06c
    • /
    • pp.323-326
    • /
    • 1998
  • The paper describes a theoretical and experimental study on the speed of the torsional elastic waves propagating in an axisymmetirc waveguide whose cross-sectional area varies periodically as an harmonic function of the axial coordinate. The approximate solution of the phase speed has been obtained using the perturbation technique for sinusoidal modulation of small amplitude. The experiment verifying the theoretical result consists of transmitting and receiving torsional waves by magnetostriction and measuring the wave speed in the waveguides with threaded surfaces.

  • PDF

Fish Toxicity Tests for Endocrine Disrupting Chemicals

  • Tadokoro, Hiroshi
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2001.05a
    • /
    • pp.42-43
    • /
    • 2001
  • Ecotoxicology is a research area for adverse effect of chemicals to ecosystem. While toxicology is directly related to human health, relation between ecotoxicology and human health is indirect. In this connection, public awareness of environmental effect has been rather behind that for health effects. Historically the first concern in ecotoxicology was adverse effect of pollution on organisms in waters receiving industrial wastewater. (omitted)

  • PDF

Improvement of Fringe Area using ICS Extremely Low Power Repeater (ICS 극소출력 중계기를 이용한 난시청 개선)

  • Choi, Soo-cheol;Cho, Ki-ryang
    • Journal of Broadcast Engineering
    • /
    • v.21 no.1
    • /
    • pp.97-104
    • /
    • 2016
  • In this paper, in order to relieve the area of terrestrial DTV broadcasting, we watch the same channel DTV Repeater output ICS using nano field test and analysis of effect was proven. Interspersed throughout the blanket area(natural) and buildings(artificially) 7 established the field selected as the test area, and each station(KBS1, KBS2, MBC, SBS, EBS) Extremely Low Power ICS Repeater the same channel of the receiving field strength and after install, SNR(Signal to Noise Ratios) verify the equipment to measure the efficacy and minimal output for future ICS type nav should you wish to provide a research-based for the spread.

Heavy Metal Contamination of Roadside Gully-Pot Sediments, Seoul, Korea

  • Kim, Sung-Hwan;Lee, Pyeong-Koo;Yun, Seong-Taek;So, Chil-Sup
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.222-225
    • /
    • 2001
  • In urban environments, the surface land impermeability fundamentally related to urban growth emphasizes the environmental problems such as the storm water peak flow (so-called the urban flooding) and the pollution. The conventional urban drainage system provides a number of temporary reservoirs intercepting and retaining surface-derived pollutants following their introduction to and deposition upon the impermeable surface. Gully-pots are common features in urban drainage systems in Korea, which were installed for draining rainwater to prevent regurgitation in rainy season and retaining larger particles, hence minimizing pipe blockage problems. When the road runoff conveying sediment enters a gully-pot, the sediment mixes with the gully liquor causing direct pollution of receiving waters. The characteristics of local sediment contamination are usually related to the types of land use activities that take place or have taken place within the area., This study was undertaken to evaluate the spatial and temporal variations of the contamination of gully-pot sediments in Seoul with respect to heavy metals such as As, Cd, Co, Cr, Ni, Pb, Cu and Zn. The heavy metal data were examined according to the land use type. In this paper, sampling sites in Seoul were divided into six groups (commercial area, industrial area, residental area, motor way, rural area, and local pollution).

  • PDF

A Study on Runoff Characteristics of Combined Sewer Overflow(CSO) in Urban Area Using GIS & SWMM

  • Kim, Jae-Hoon;Paik, Do-Hyeon
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.6
    • /
    • pp.467-474
    • /
    • 2005
  • The runoff characteristics of combined sewer overflow(CSO) in the urban area of Jeonju were investigated and analyzed by using the SWMM (Storm Water Management Model) and GIS. From August to November 2004, investigations on two rainfall events were performed and flowrate, pH, BOD, COD, SS, T-N and T-P were measured. these data were used for model calibration. Using GIS technique, watershed characteristics of study area were calculated. that is, divide into sub_basin, total width, slope, make soil map etc. On the basis of the measured data and the simulation results by SWMM, it could be known that the $80-90\%$ of pollution load are discharged in early-stage storm runoff. SMC(site mean Concentration) for combined sewer system area were BOD 28.1, COD 31.5, SS 186 ppm etc. this is shown that during the rain fall, high concentration of waste was loaded to receiving water. Unit loads of combined sewer system area were BOD 306, COD 410, SS 789, T-N 79, T-P 6.8 kg/ha/yr.