• 제목/요약/키워드: Rebar Lap

검색결과 24건 처리시간 0.025초

Investigating Structural Stability and Constructability of Buildings Relative to the Lap Splice Position of Reinforcing Bars

  • Widjaja, Daniel Darma;Rachmawati, Titi Sari Nurul;Kwon, Keehoon;Kim, Sunkuk
    • 한국건축시공학회지
    • /
    • 제23권3호
    • /
    • pp.315-326
    • /
    • 2023
  • The design principles and implementation of rebar lap splice in architectural structures are governed by building regulations. Nevertheless, the minimization of rebar-cutting waste (RCW) is often impeded by the mandatory requirements pertaining to the rebar lapping zone as prescribed in design codes. In real-world construction scenarios, compliance with these rules often falls short due to hurdles concerning productivity, quality, safety, time, and cost. This discrepancy between code stipulations and on-the-ground construction practices necessitates an academic exploration. The goal of this research was to delve into the effect of rebar lap splice placement on the robustness and constructability of building edifices. The study initially took on a review of the computation of rebar lapping length and the rules revolving around the lapping zone. Following this, a structural robustness and constructability examination was undertaken, focusing on adherence to the lap splice zone. The interpretations and deductions of the research led to the following insights: (1) the efficacy of rebar lap splice is not solely contingent on the moment, and (2) the implementation of rebar lap splice beyond the specified zone can match the structural integrity and robustness of those confined within the designated area. As a result, the constraints on the rebar lapping zone ought to be revisited and possibly relaxed. The conclusions drawn from this research are anticipated to reconcile the disconnect between building codes and practical construction conditions, furnishing invaluable academic substantiation to further the endeavor of achieving near-zero RCW.

용융아연도금 철근콘크리트 보의 부착강도 특성 (Characteristics of Bond Strength in Concrete Beams Reinforced with Galvanized Rebar)

  • 신재혁;김경철;양인환
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권4호
    • /
    • pp.136-143
    • /
    • 2015
  • 용융아연도금(galvanizing)은 콘크리트 구조물의 철근 부식 문제를 해결하기 위해 사용된다. 용융아연도금 철근 콘크리트 보의 부착강도 영향에 대한 자료는 거의 없는 실정이다. 따라서, 이 연구의 목적은 용융아연도금철근이 콘크리트 보의 부착강도에 미치는 영향을 파악하는데 있다. 용융아연도금철근을 사용한 부재와 일반철근을 사용한 부재의 구조실험을 통하여 겹침이음 거동과 부착강도 특성을 비교하였다. 실험변수로써 철근의 용융아연코팅 유무, 철근 직경과 겹침이음 길이를 고려하였다. 용융아연도금 철근콘크리트 보의 균열 및 파괴 특성을 파악하였다. 용융아연도금철근 콘크리트 보의 겹침이음부 휨 거동특성은 일반철근 콘크리트 보의 겹침이음부 휨거동과 유사한 것으로 나타난다. 또한, 용융아연도금철근의 사용은 일반철근을 사용할 때에 비해 콘크리트 보의 부착강도에 불리한 영향을 미치지는 않는 것으로 나타났다.

섬유혼입조건 및 팽창재 대체에 따른 변형 경화형 시멘트 복합체 내의 철근 겹침이음 성능 (Effects of Fiber Blending Condition and Expansive Admixture Replacement on Tensile Performance of Rebar Lap Splice in Strain-Hardening Cement-Based Composites (SHCCs))

  • 류승현;이영오;윤현도
    • 콘크리트학회논문집
    • /
    • 제24권2호
    • /
    • pp.111-120
    • /
    • 2012
  • 이 연구는 섬유 보강 시멘트 복합체(SHCC) 내에 매립된 철근의 겹침이음 성능을 평가하고자 하였으며, 이에 따라 단조 및 반복 재하시의 겹침이음된 철근의 인장 실험을 실시하였다. 총 10개의 SHCC 및 콘크리트 배합이 계획되었으며, 실험체의 변수는 보강섬유 종류(폴리에틸렌 및 강섬유), 팽창재 대체율(0% 및 10%) 및 실험체의 설계강도(30 MPa 및 100 MPa)로 계획하였다. SHCC 및 콘크리트 배합에 매립된 철근의 겹침이음 길이는 각각 콘크리트 구조설계 기준에 의거하여 산정된 겹침이음 길이의 60% 및 100%를 적용하였다. 실험 결과 SHCC에 철근이 매립될 경우 철근의 겹침이 음 성능을 향상시키는 것으로 나타났으며, SHCC 배합에서 보강 섬유 종류(PE-SHCC 및 PESF-SHCC)에 관계없이 겹침 이음된 철근의 인장강도 및 부착강도 증진에 기여하는 것으로 나타났다. 또한 SHCC에 팽창재를 대체할 경우 SHCC에 매립된 철근 겹침이음부의 거동 특성을 개선하는 특징을 보였다. 한편 균열 특성에서는 배합조건 및 재료특성에 따라 PE-SHCC가 PESF-SHCC에 비해 보다 많은 미세균열 특성을 나타내었다. 전언한 바와 같이 이 연구는 SHCC의 변형경화 특성에 따라 매립된 철근과의 상호작용을 증진시킴에 따라, SHCC에 매립된 철근 겹침이음 길이를 감소할 경우에도 양호한 거동 특성을 보이는 것으로 판단된다.

노후도를 고려한 실크기 원형단면 교각의 내진성능 휨실험 (Seismic-performance Flexural Experiments for Real Scale Piers with Circular Cross-section Considering Aging Effects)

  • 이승건;이수형;이혜린;홍기증
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권6호
    • /
    • pp.131-142
    • /
    • 2021
  • 노후 교각은 내진설계가 적용되지 않아 소성힌지구역에 겹침이음이 대다수 존재한다. 철근부식은 철근 단면적 감소 및 겹침이음부의 거동저하를 유발하여 교각의 내진성능을 저하시킨다. 본 연구에서는 이러한 노후교각의 특성에 따라 철근부식, 겹침이음, 내진설계 및 내진 보강 여부를 고려하여 실험체를 설계 및 제작하고 실험을 통해 그 영향을 조사하였다. 실험결과, 겹침이음 또는 철근부식은 변위연성도를 감소시킨다. 내진설계 상세 또는 강판 내진보강을 적용하면 충분한 변위연성도가 확보됨을 확인하였다. 모든 비내진실험체는 소성힌지구역 내의 횡철근 겹침이음부의 풀림으로 인해 주철근 좌굴과 심부콘크리트 압축파쇄가 발생하였다. 내진설계된 실험체는 철근부식에 의한 소성힌지구역 내 횡철근의 단면감소와 갈고리 풀림에 의해 주철근 좌굴 및 심부콘크리트 압축파쇄가 발생하였다.

한정연성도 설계를 위한 소수 겹침이음을 갖는 주철근 상세에 관한 연구 (Less amout of lap-spliced longitudinal bars as an alternative of seismic detailing for limited ductility design)

  • 김익현;이종석;김원섭;선창호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.255-262
    • /
    • 2003
  • In present Korea Highway Bridge Standards the lap splice of longitudinal bars in a potential plastic hinge region is allowed so that large amount of transverse rebar specified in high seismicity regions Is required to prevent brittle bond failure If the brittle failure effects can be completely removed from the conventional designed piers, the amount of transverse rebar will be reduced drastically. In this study scaled models with solid and hollow rectangular sections were tested to investigate the seismic behavior of RC piers with 50% of lap-spliced longitudinal bars in plastic hinge regions. In the tests the typical flexural failure conducting a ductile behavior were observed in both models. It is shown that the 50% of lap-spliced bars can be considered as a good alternative of seismic detailing for longitudinal bars.

  • PDF

철근 이음조정률의 개선을 위한 설계견적 수량과 현장시공 정산 수량의 비교분석 연구 (Comparison of the quantity estimations from the design phase and the settlement quantities of construction field to improve the extra rates of bar splice)

  • 김상연;최보미
    • 토지주택연구
    • /
    • 제8권4호
    • /
    • pp.257-266
    • /
    • 2017
  • LH has been using ultra high strength reinforcing bars (SD500 and SD600), since 2011. Such a change requires an adjustment of the old extra rates of bar splice to reflect use of ultra high strength reinforcing bars, as these rates had been set based on SD400 bars. It is particularly difficult to calculate precisely rebar lap-splice locations for large areas, such as those in apartment buildings. This research aims to adjust the extra rates of bar splice to reflect a reasonable rate; the rebar lap-splice length is not an exact estimation, but instead, an extra rates of bar splice is set and the rebar lap-splice length is increased by 2% (D 10) - 7% (025) depending on the bar size. The subjects of this study are LH apartments undergoing frame construction. We studied the quantity estimations from the design drawings, and analyzed the settlement quantities of construction field. The results of the study revealed that, when each of the quantities are analyzed, consider adjusting the extra rates of bar splice of some rebar to 1% - 3.5%. This was caused by an overuse of reinforcing bars in onsite construction and the use of supporting bars that have not been reflected in the documents, among other reasons. Based on the results of our study, an improvement plan for the current extra rates of bar splice seems to be necessary, cutting or raising the rate depending on the analysis of the data. Through this study, we expect to contribute to the calculation of reasonable construction costs, improvements in the quality of rebar work, and improvements in the capacity of design techniques for apartment buildings.

볼트 접합형 철근 이음장치 개발을 위한 요구조건 분석 (Requirement analysis for Development of the Bolt-type Rebar Coupler)

  • 임채연;주진규;이군재;김선국
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.169-170
    • /
    • 2011
  • In the connection of green frame, the bottom rebar of the precast concrete beam needs joint or anchorage to ensure structural integrity. However, given the characteristics of composite precast concrete joint, enough length over which rebar can be anchored or lap-spliced is not secured. In addition, due to issues with constructability, cost or quality, it is difficult to apply welding or mechanical connection techniques. Therefore, this study analyze the requirement for a bolt-type rebar coupler as a solution for the coupling issue between the lower rebars of green frame beam. The requirement for bolt-type rebar coupler proposed herein will provide basic data for development studies of the rebar coupler.

  • PDF

하부철근 이음길이에 따른 PC 보 제작 길이 산정 (Estimation of production length of PC beam by using splice length of bottom rebar)

  • 성수진;임채연;김선국
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.84-85
    • /
    • 2014
  • Green frame is column-beam structure composed of precast concrete members. Based on Revision of Structural Concrete Design Code, the bottom rebar of beam shall be extend at least 150mm into the support member. However, if the bottom rebar extend to satisfy Revision of Structural Concrete Design Code, the installation fo beam is impossible due to interference between the columns and beams. Thus, the aim of this study is estimation of production length of precast concrete beam by using splice length of bottom rebar. In this study to solve this problem, lap splice were used on the join. This study was calculated length of the reinforcement by the diameter. According to the length of the rebar, the production length of beam concrete was calculated. The results of this study will satisfy the Revision of Structural Concrete Design Code about column-beam connection when green frame will be applied.

  • PDF

콘크리트 강도변화에 따른 D22mm 철근의 압축이음 성능 평가 (An evaluation of compressive lap splice of the D22 rebar by concrete strengths)

  • 이성호;천성철;오보환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.1081-1084
    • /
    • 2008
  • 고강도 콘크리트의 적용 확대에 반해, 현행 철근의 정착 및 이음 산정식은 70MPa 미만의 콘크리트로 한정되어 있으며, 50MPa 이상에서는 압축이음길이가 인장이음보다 길어지는 현상이 발생하는 등 관련 기술이 미비한 상태이다. 본 연구에서는 고강도 콘크리트에서 콘크리트 압축강도, 철근간격, 직교방향 보강 철근의 위치와 보강량에 따른 철근 압축이음내력 특성을 평가하였다. 압축이음된 22mm 철근을 주근으로 가지는 총 64개의 기둥 실험체를 제작하여, 단조 일축 압축 하중을 파괴 시 까지 재하하여 실험을 수행하였다. 실험결과 콘크리트의 압축강도, 압축 이음 길이, 철근간격 및 직교방향 보강 철근 등이 철근의 압축이음 내력을 결정하는 주요한 요소로 작용하는 것으로 분석되었다.

  • PDF

BIM Model 기반 철근 수량산출 시 고려사항 (Considerations When Quantity Take-Off of Rebar Based on the BIM Model)

  • 정서희;김주용;김광희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.73-74
    • /
    • 2023
  • The purpose of this study is to derive the cause of the quantity difference and present the considerations when take-off rebar quantity based on BIM model by comparing the quantity of rebar based on BIM model with 2D drawing. This research was limited to take-off the quantity of rebars in the building frame work, and after take-off the quantity of rebars by 3D modeling the 2D drawing of the target building with Revit, the quantity difference was compared with 2D-based software. Therefore, when take-off the quantity of rebars based on the BIM model, instead of take-off the existing 2D-based quantity premium proportion, according to general structural consider development length, lap splice length, covering thickness, reinforcing bars and spacing. In the future, this study is expected to contribute to improving the accuracy of BIM-based frame construction quantity take-off.

  • PDF