• Title/Summary/Keyword: Reaction Accuracy

Search Result 396, Processing Time 0.026 seconds

A Study on the Effect of Wind Load to an Articulated type Container Crane by Fluid-Structural Coupled Field Analysis (유동-구조 연성해석기법을 이용한 풍하중이 관절형 컨테이너 크레인에 미치는 영향에 관한 연구)

  • An, Tae-Won;Lee, Seong-Wook;Han, Dong-Seop;Kim, Tae-Hyung;Han, Geun-Jo
    • Journal of Navigation and Port Research
    • /
    • v.32 no.1
    • /
    • pp.23-27
    • /
    • 2008
  • This study was carried out to the effect of wind load on the structural stability of an articulated type container crane according to the wind direction assuming that 75m/s wind velocity is applied on a container crane using FSI(fluid-structural interaction). To consider fluid phenomenon around the container crane, the wind load was derived by the computation fluid dynamic, and it applied to the FSI which can guarantee an accuracy and a reliability in the design stage for wind resistant structural stability to minimize the damage due to high wind load applied in a container crane with a 'ㄱ' type articulated boom which used in the total height restriction region. Following from this, the reaction force on the each support of a container crane was suggested. ANSYS ICEM CFD 10.0 and ANSYS CFX 10.0 used for computation fluid dynamic, and the ANSYS Workbench 11.0 was used for the fluid-structural interaction.

Bioequivqlence of Gabarep Tablet to Neurotin Tablet (Gabapentin 800 mg) (가바렙정 (가바펜틴 800 mg)의 생물학적 동등성 평가)

  • Seo, Young-Hwan;Jeong, Ju-Cheol;Lee, Jae-Young;Li, Zheng-Yi;Yoon, Hyoung-Jong;Sohn, Uy-Dong;Bang, Joon-Seok;Kim, Ho-Hyun;Jeong, Ji-Hoon
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.4
    • /
    • pp.261-267
    • /
    • 2008
  • The aim of the present study was to evaluate the bioequivalence of two gabapentin preparations. We used Neurontin tablet 800 mg (Pfizer Korea Inc.) as a reference drug for bioequivalence of Gabalep tablet 800 mg (Chong Kun Dang Pharmaceutical Co., Korea), and performed this whole study according to the guidelines of Korea Food and Drug Administration (KFDA). Twenty five healthy male volunteers were administered with each drug in a randomized $2{\times}2$ cross-over study with one week washout interval. After drug administration, blood was taken at predetermined time intervals ($0{\sim}24$ hours) and the concentrations of gabapentin in serum were determined using an high performance liquid chromatography-tandem mass spectrometer (LC-MS/MS) employing electrospray ionization technique and operating in multiple reaction mornitoring (MRM). The analytical method was validated in specificity, accuracy, precision and linearity. The phar-macokinetic parameters such as AUCt and Cmax were calculated and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed AUCt and Cmax. $Mean{\pm}SD$. of AUCt and Cmax value for reference drug and test drug were $29.94{\pm}9.23\;({\mu}g/mL{\cdot}hr)$ and $3.12{\pm}1.11\;({\mu}g/mL{\cdot}hr)$, and $31.48{\pm}9.77\;({\mu}g/mL{\cdot}hr)$ and $3.15{\pm}1.03\;({\mu}g/mL)$, respectively. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log(0.8) to log(1.25) for AUCt and Cmax, respectively. These results indicate that Gabalep tablet 800 mg is bioequivalent to Neurontin tablet 800 mg.

Simultaneous determination of preservatives in sausages using liquid chromatography with electrospray ionization tandem mass spectrometry (LC-MS/MS를 이용한 소시지 중 보존료 동시분석)

  • Koh, Ba-Ra-Da;Kim, Ji-Yeon;Jang, Mi-Sun;Seo, Doo-Ri;Jung, Bo-Ram;Shin, Ji-Hyun;Lim, Jin-Taek;Kim, Yong-Hwan;Kim, Eun-Sun
    • Korean Journal of Veterinary Service
    • /
    • v.38 no.2
    • /
    • pp.127-136
    • /
    • 2015
  • A simultaneous determination method was developed for nine preservatives (benzoic acid, sorbic acid, dehydroacetic acid, methyl-, ethyl-, isopropyl-, propyl-, isobutyl- and butyl-parabens) in sausage by liquid chromatography with electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS). Each parameter was established by multiple reaction monitoring in negative mode. Separation was achieved on a phenyl-hexyl ($2.5{\mu}m$, $2.1{\times}150mm$, Waters) with A-20 mM ammonium acetate containing 0.1% acetic acid in water, B-Acetonitrile as mobile phase with gradient mode at a flow rate of 0.3 mL/min. The developed method was validated for specificity, linearity, accuracy and precision in sausages samples. Linearity was over 0.998 with calibration curve of the mixed standards. The mean recoveries from sausages fortified at the level of 2.0~10.0 mg/L were in range of 98.60~109.16% with RSDs lower than 8.93%. The limits of detection (LOD) and the limits of quantification (LOQ) were in the range between 0.0003~0.085 mg/L and 0.01~0.257 mg/L, respectively. Intra-day precision and inter-day precision were 0.45~6.16% and 2.81~13.33%, respectively. Using presently developed determination method, 33 field sausage samples from Gwangju city in Korea were screened over nine preservatives. As a result, no preservatives were detected in all samples.

Phototoxicity Evaluation of Pharmaceutical Substances with a Reactive Oxygen Species Assay Using Ultraviolet A

  • Lee, Yong Sun;Yi, Jung-Sun;Lim, Hye Rim;Kim, Tae Sung;Ahn, Il Young;Ko, Kyungyuk;Kim, JooHwan;Park, Hye-Kyung;Sohn, Soo Jung;Lee, Jong Kwon
    • Toxicological Research
    • /
    • v.33 no.1
    • /
    • pp.43-48
    • /
    • 2017
  • With ultraviolet and visible light exposure, some pharmaceutical substances applied systemically or topically may cause phototoxic skin irritation. The major factor in phototoxicity is the generation of reactive oxygen species (ROS) such as singlet oxygen and superoxide anion that cause oxidative damage to DNA, lipids and proteins. Thus, measuring the generation of ROS can predict the phototoxic potential of a given substance indirectly. For this reason, a standard ROS assay (ROS assay) was developed and validated and provides an alternative method for phototoxicity evaluation. However, negative substances are over-predicted by the assay. Except for ultraviolet A (UVA), other UV ranges are not a major factor in causing phototoxicity and may lead to incorrect labeling of some non-phototoxic substances as being phototoxic in the ROS assay when using a solar simulator. A UVA stimulator is also widely used to evaluate phototoxicity in various test substances. Consequently, we identified the applicability of a UVA simulator to the ROS assay for photoreactivity. In this study, we tested 60 pharmaceutical substances including 50 phototoxins and 10 non-phototoxins to predict their phototoxic potential via the ROS assay with a UVA simulator. Following the ROS protocol, all test substances were dissolved in dimethyl sulfoxide or sodium phosphate buffer. The final concentration of the test solutions in the reaction mixture was 20 to $200{\mu}M$. The exposure was with $2.0{\sim}2.2mW/cm^2$ irradiance and optimization for a relevant dose of UVA was performed. The generation of ROS was compared before and after UVA exposure and was measured by a microplate spectrophotometer. Sensitivity and specificity values were 85.7% and 100.0% respectively, and the accuracy was 88.1%. From this analysis, the ROS assay with a UVA simulator is suitable for testing the photoreactivity and estimating the phototoxic potential of various test pharmaceutical substances.

Characterizing Milk Production Related Genes in Holstein Using RNA-seq

  • Seo, Minseok;Lee, Hyun-Jeong;Kim, Kwondo;Caetano-Anolles, Kelsey;Jeong, Jin Young;Park, Sungkwon;Oh, Young Kyun;Cho, Seoae;Kim, Heebal
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.3
    • /
    • pp.343-351
    • /
    • 2016
  • Although the chemical, physical, and nutritional properties of bovine milk have been extensively studied, only a few studies have attempted to characterize milk-synthesizing genes using RNA-seq data. RNA-seq data was collected from 21 Holstein samples, along with group information about milk production ability; milk yield; and protein, fat, and solid contents. Meta-analysis was employed in order to generally characterize genes related to milk production. In addition, we attempted to investigate the relationship between milk related traits, parity, and lactation period. We observed that milk fat is highly correlated with lactation period; this result indicates that this effect should be considered in the model in order to accurately detect milk production related genes. By employing our developed model, 271 genes were significantly (false discovery rate [FDR] adjusted p-value<0.1) detected as milk production related differentially expressed genes. Of these genes, five (albumin, nitric oxide synthase 3, RNA-binding region (RNP1, RRM) containing 3, secreted and transmembrane 1, and serine palmitoyltransferase, small subunit B) were technically validated using quantitative real-time polymerase chain reaction (qRT-PCR) in order to check the accuracy of RNA-seq analysis. Finally, 83 gene ontology biological processes including several blood vessel and mammary gland development related terms, were significantly detected using DAVID gene-set enrichment analysis. From these results, we observed that detected milk production related genes are highly enriched in the circulation system process and mammary gland related biological functions. In addition, we observed that detected genes including caveolin 1, mammary serum amyloid A3.2, lingual antimicrobial peptide, cathelicidin 4 (CATHL4), cathelicidin 6 (CATHL6) have been reported in other species as milk production related gene. For this reason, we concluded that our detected 271 genes would be strong candidates for determining milk production.

Development of Analytical Method for Colistin in Fish and Shrimp using Liquid Chromatography Mass Spectrometry (LC-MS/MS를 이용한 수산물 중 콜리스틴 분석법 개발)

  • Shin, Dasom;Kang, Hui-Seung;Lee, Soo-Bin;Cho, Yoon-Jae;Cheon, So-Young;Jeong, Jiyoon;Rhee, Gyu-Seek
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.5
    • /
    • pp.319-326
    • /
    • 2016
  • Colistin is a last resort antimicrobial agent against multi-drug resistant Gram-negative bacteria. This study was conducted to develop an analytical method to determine colistin in fish and shrimp. The analytes were confirmed and quantified via liquid chromatography-tandem mass spectrometry (LC-MS/MS) in the positive ion mode using multiple reaction monitoring (MRM). The sample was extracted with acidified 5% methanol (containing 0.5% formic acid). Then, solid phase extraction (SPE) was used for cleanup. Matrix-matched calibration curves were linear over the calibration ranges (0.05-1.2 mg/kg) for all the analytes into blank sample with $r^2$ > 0.99. All the values fulfilled the criteria requested by the Codex guidelines. Average recoveries ranged from 85.9% to 107.9%. The repeatability of measurements, expressed as the coefficient of variation (CV, %), was less than 15%. The limit of detection (LOD) was 0.02 mg/kg, and the limit of quantitation (LOQ) was 0.05 mg/kg. This improved method showed higher accuracy and acceptable sensitivity to meet the CAC guideline requirements and is applicable for the analysis of residual colistin (A+B) in fish and shrimp.

Establishment of Artificial Screening Methods and Evaluation of Barley Germplasms for Resistance to Fusarium Head Blight (보리 붉은곰팡이병 검정법과 저항성 품종 선발)

  • Han Ouk-Kyu;Kim Jung-Gon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.50 no.3
    • /
    • pp.191-196
    • /
    • 2005
  • Fusarium head blight (FHB) is a severe disease problem that affects the quality and yield of barley grain. The evaluation of FHB resistance is difficult because environmental conditions greatly influence FHB infection and development. The objectives of this study were to: 1) establish an efficient screening method for selecting resistant barley to FHB, 2) compare FHB severity between the cut-spike method and pot-plant method for development of mass screening, and 3) estimate FHB resistance for barley germplasms. Barley cultivars and lines were evaluated for reaction to FHB in controlled-greenhouse condition. Spikes were spray-inoculated with a suspension $(5.0\times10^5\;macroconidia\;mL^{-1})$ of Fusarium graminearum SCK-O4 strain, and then kept in a greenhouse at $18-25^{\circ}C$ with $80-100\%$ relative humidity. Inoculation were employed at 3 different heading growth stages (heading date, three days after heading, and five days after heading). The inoculation was performed in 2 consecutive days in order to avoid escapes. The inoculated plants were maintained in the greenhouse at 4 different free moisture periods (1, 3, 5, and 7 days). The percentage of FHB severity was scored from 0 to 9 according to the rate of infected kernels per spike, and three spikes were evaluated per replication with 3 replicates. There were significant differences of FHB severity depending on the different free moisture periods, but not by the inoculation at different heading stages. The optimum evaluation point of FHB severity in the greenhouse condition was on the 7th day under free moisture condition after inoculation at the heading date. Infection level in cut-spike method highly correlated with that in pot-plant method. This suggested that cut-spike method is useful in evaluating of FHB resistance in barley. Six cultivars, such as Jinkwang, Buheung, Atahualpha 92, Chevron-b, Gobernadora-d, and MNBrite-c, were selected as resistant varieties to FHB. Correlation coefficient for the FHB severity evaluated by the pot-plant method between two seasons was 0.794, indicating the stability and accuracy of the screening method.

Development of a Method of Cybersickness Evaluation with the Use of 128-Channel Electroencephalography (128 채널 뇌파를 이용한 사이버멀미 평가법 개발)

  • Han, Dong-Uk;Lee, Dong-Hyun;Ji, Kyoung-Ha;Ahn, Bong-Yeong;Lim, Hyun-Kyoon
    • Science of Emotion and Sensibility
    • /
    • v.22 no.3
    • /
    • pp.3-20
    • /
    • 2019
  • With advancements in technology of virtual reality, it is used for various purposes in many fields such as medical care and healthcare, but as the same time there are also increasing reports of nausea, eye fatigue, dizziness, and headache from users. These symptoms of motion sickness are referred to as cybersickness, and various researches are under way to solve the cybersickness problem because it can cause inconvenience to the user and cause adverse effects such as discomfort or stress. However, there is no official standard for the causes and solutions of cybersickness at present. This is also related to the absence of tools to quantitatively measure the cybersickness. In order to overcome these limitations, this study proposed quantitative and objective cybersickness evaluation method. We measured 128-channel EEG waves from ten participants experiencing visually stimulated virtual reality. We calculated the relative power of delta and alpha in 11 regions (left, middle, right frontal, parietal, occipital and left, right temporal lobe). Multiple regression models were obtained in a stepwise manner with the motion sickness susceptibility questionnaire (MSSQ) scores indicating the susceptibility of the subject to the motion sickness. A multiple regression model with the highest under the area ROC curve (AUC) was derived. In the multiple regression model derived from this study, it was possible to distinguish cybersickness by accuracy of 95.1% with 11 explanatory variables (PD.MF, PD.LP, PD.MP, PD.RP, PD.MO, PA.LF, PA.MF, PA.RF, PA.LP, PA.RP, PA.MO). In summary, in this study, objective response to cybersickness was confirmed through 128 channels of EEG. The analysis results showed that there was a clearly distinguished reaction at a specific part of the brain. Using the results and analytical methods of this study, it is expected that it will be useful for the future studies related to the cybersickness.

Development of LC-MS/MS Quantitation Method for Ethoxyquin in Fishery Products (수산물 중 에톡시퀸의 LC-MS/MS 정량분석법 개발)

  • Shin, Dasom;Chae, Young-Sik;Kang, Hui-Seung;Lee, Soo-Bin;Cho, Yoon-Jae;Cheon, So-Young;Jeong, Jiyoon;Rhee, Gyu-Seek
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.6
    • /
    • pp.432-438
    • /
    • 2016
  • Ethoxyquin (EQ, 1,2-dihydro-6-ethoxy-2,2,4-trimethyl-quinoline) is quinoline-based antioxidant used in the animal feed and food industry to protect the raw materials and final products against oxidation. In recent years the use of synthetic antioxidants in fishmeal ingredients carry-over to farmed fish fillets has received increasing attention in food safety. This study was conducted to develop an analytical method to determine EQ in aquatic products. The analytes were confirmed and quantified via liquid chromatography-tandem mass spectrometry (LC-MS/MS) in the positive ion mode using multiple reaction monitoring (MRM). The sample was extracted with 1 N HCl (in case of flatfish extracted with 1 N HCl containing 10% acetonitrile). Then, solid phase extraction (SPE) was used for the cleanup. Standard calibration curves presented linearity with the correlation coefficient ($r^2$) > 0.99, analyzed at 0.005-0.2 mg/kg concentration. The developed method was validated according to the Codex Alimentarius Commission (CAC) guideline. The limits of quantitation for EQ were 0.01 mg/kg. Average recoveries ranged from 81.3% to 107%. The repeatability of measurements, expressed as the coefficient of variation (CV, %), was below 10%. The analytical method was characterized with high accuracy and acceptable sensitivity to meet CODEX guideline requirements and would be applicable to analyze the EQ residue in aquatic products.

Development of Analytical Method for Determination of Baicalin, Eleutheroside E, and Ligustilide by LC-MS/MS in Raw Materials of Health Functional Foods (LC-MS/MS를 이용한 건강기능식품 원료 중 바이칼린, 엘레우테로사이드 E, 리구스틸라이드 동시분석법 개발)

  • Keum, Eun Hee;Chung, So Young;Lee, Jin Hee;Kim, Meehye
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.3
    • /
    • pp.193-198
    • /
    • 2017
  • Scutellaria baicalensis, Eleutherococcus senticosus, and Angelica sinensis have been used as raw materials for health functional foods. This study was conducted to develop a novel method to analyze levels of baicalin (Scutellaria baicalensis), eleutheroside E (Eleutherococcus senticosus), and ligustilide (Angelica sinensis) simultaneously in health functional foods. The methanol extracted samples were analyzed and quantified via liquid chromatography-tandem mass spectrometry (LC-MS/MS) in the positive ion mode and the negative ion mode using multiple reaction monitoring. Standard calibration curves confirmed linearity with the correlation coefficient ($r^2$) of > 0.99 at $100-2000{\mu}g/mL$ concentration range. The limits of detection (LODs) and limits of quantitation (LOQs) were in the range of $13.0{\sim}35.2{\mu}g/L$ and $39.3{\sim}106.7{\mu}g/L$, respectively. The recovery results ranged between 91.4~109.9% at 3 different concentration levels with relative standard deviations (RSDs) less than 5%. The proposed analytical method was characterized with high accuracy and acceptable precision. The new method would be an effective tool to analyze baicalin, eleutheroside E, and ligustilide simultaneously in raw materials of health functional foods.