• Title/Summary/Keyword: Rating power

Search Result 516, Processing Time 0.03 seconds

A Simple Resonant Link Inverter for a Discrete-Time Current Control (이산 전류 제어를 위한 공진형 인버터)

  • 오인환;정영석;주형길;윤명중
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.1
    • /
    • pp.36-45
    • /
    • 1998
  • A simple source voltage clamped resonant link (SVCRL) inverter is proposed to clamp the DC link voltage to the input source voltage and reduce the current rating of resonant inductor. The current control of a permanent magnet synchronous motor (PMSM) using a predictive current control technique (PCCT) employing the SVCRL inverter is also investigated to overcome the disadvantage of the current regulated delta modulation (CRDM) control technique. By using the PCCT based on the discrete model of a PMSM and estimation of back EMF, the minimized current ripple with small number of switchings can be obtained. Finally, the comparative computer simulation and experimental results are given to show the usefulness of the proposed technique.

An Active Cancellation Method for the Common Mode Current of the Three-Phase Induction Motor Drives (3상 유도전동기 구동장치의 동상모드 전류 능동 제거법)

  • Uzzaman, Tawfique;Kim, Unghoe;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.96-97
    • /
    • 2019
  • Pulse Width Modulation (PWM) is a widely adopted technique to drive the motor using the voltage source inverters. Since they generate high frequency Common Mode (CM) Voltage, a high shaft voltage in induction motor is induced which leads to parasitic capacitive currents causing adverse effects such as premature deterioration of ball bearings and high levels of electromagnetic emissions. This paper presents an Active Cancellation Circuit (ACC) which can significantly reduce the CM voltage hence the common mode current in the three phase induction motor drives. In the proposed method the CM voltage is detected by the capacitors and applied to the frame of the motor to cancel the CM voltage hence the CM current. Unlike the conventional methods the proposed method does not insert the transformer in between the inverter and motor, a high power rating three phase transformer is not required and no losses associated with it. In addition the proposed method is applicable to any kind of PWM motor drives regardless of their PWM methods. The effectiveness of the proposed method is proved by the experiments with a three phase induction motor (1.1kW 415V/60Hz) combined with a three phase voltage source inverter modulated by the Space Vector Modulation (SVM).

  • PDF

Parameter Selection of the Saturable Reactor for Removing Ferroresonance of 362kV Gas VT Using EMTP (EMTP를 이용한 362kV Gas VT의 철공진제거를 위한 가포화리엑터의 파라미터 선정)

  • Choi, Jae-Gu;Kim, Ik-Soo;Park, Kyoung-Won;Song, Hee-Suk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.4
    • /
    • pp.197-203
    • /
    • 2001
  • Recently, the construction of gas insulated substation(GIS)s has been increased in Korea. But, the whole quantity of the VTs which were used in GIS has been imported. Under the circumstance that $SF_6$ gas power apparatus are being developed up to 800kV rating in Korea, the development of EHV $SF_6$ gas VT is essential for localizing the power apparatus. As for EHV VT, destructive ferroresonance can be generated due to the combination of capacitiances between poles of circuit breaker, ground capacitance of bus and nonlinear excitation property of VT core. But the theoretical analysis about ferroresonance has not been fully achieved in Korea. Therefore, in this paper the authors would like to contribute for localizing EHV $SF_6$ gas VT by developing the diagram of ferroresonance zone according to the parameters of the circuit and the saturable reactor.

  • PDF

A Study on Discriminant Function of KWIS Subscales in Schizophrenic Patients (정신분열증 환자에 있어서 KWIS 하위검사 판별기능에 관한 연구)

  • Lee, Jung-Hoon
    • Journal of Yeungnam Medical Science
    • /
    • v.7 no.2
    • /
    • pp.89-96
    • /
    • 1990
  • The purpose of this article was to determine the discriminant function analysis of the Korean Wechsler Intelligence Scale(KWIS) for 110 normal controls and 98 schizophrenics. Of special interest was to verify the clinical discriminant power of two subtests of the KWIS(Vacabulary and Digit Symbols) and Zung' s Self-rating Anxiety Scale(SAS). Four major hypotheses were postulated. The normal control group would show higher scores than the schizophrenics ; mean scores on both Vocabulary and Digit Symbol. The mean difference in Digit Symbol between the two groups would be greater than that in the Vacabulary. There would be no significant relation among Digit Symbol. Vacabulary. and Anxiety. The most powerful discriminant power would be expected from subtest of Digit Symbol. The mean discriminant scores were - 1.34425 for the control subjects. 1.34425 for the schizophrenics. The correctly discriminated percentage was 89.1% for the control subjects. 90.8% for the schizophrenics. From the findings it was concluded that both Digit Symbol and Vocabulary scales had strong diagnostic value but the former was more powerful than the latter. However. the Anxiety scales had less diagnostic value.

  • PDF

Enhancement of Power Rating for the Resistive Fault Current Limiter (병렬우선 직렬연결된 YBCO박막형 초전도 한류기의 용량증대)

  • Park K.B.;LEE B.W.;Kang J.S.;Oh I.S.;hyun O.B.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.806-808
    • /
    • 2004
  • The series and parallel connection is essential for increasing power ratings of resistive type for fault current limiters. To increase voltage class, components are connected in series and to increase current level to the nominal value, they are connected in parallel. There are two ways to connect components in series and parallel. First, connected in series and then the module connects to the parallel. Second, connected in parallel and the module connects to the series. We have studied for the two ways. In this paper, we particularly investigated way to connect components in parallel first This way has the advantage of inducing effective simultaneous quench without any other devices, for example, the thing which is inducing magnetic field to the limiting and shunt resistors. And also we studied for the endurance of component which is patterned to the bi-spiral for prospective fault current. It is very important to understand this, because SFCL will use as the only device to decrease burden of circuit breaker. As experimental results, limiting component patterned to bi-spiral endures fault current up to 30kA and it works well, in parallel to series connection,

  • PDF

Control of Input Series Output Parallel Connected DC-DC Converters

  • Natarajan, Sirukarumbur Pandurangan;Anandhi, Thangavel Saroja
    • Journal of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.265-270
    • /
    • 2007
  • Equal rating DC-DC converter modules can be connected in series at the input for circuits requiring higher input voltages and in parallel at the output for circuits requiring higher output currents. Since the converter modules may not be practically identical, closed loop control has to ensure that each module equally shares the total input voltage and the load current. A control scheme consisting of a common output voltage loop, individual inner current loops and individual input voltage loops have been designed in this work to achieve input voltage and load current sharing as well as load voltage regulation under supply and load disturbances. The output voltage loop provides the basic reference for the inner current loops, which are also modified by the respective input voltage loops. The average of the converter input voltages, which is dynamically varying, is chosen as the reference for input voltage loops. This choice of reference eliminates interaction among different control loops. Type II compensators and Fuzzy Logic Controllers (FLCs) are designed and compared through MATLAB based simulation and FLC is found to be satisfactory. Hence TMS320F2407A DSP based FLC is implemented and the results are presented which prove the superiority of the FLC developed for this research.

Development of Back-emf Filter Circuit for Driving Sensorless BLDC Motors (BLDC 전동기의 센서리스 구동을 위한 역기전력 필터회로 개발)

  • Song, Doo-Young;Lee, Sung-Ho;Jung, Tae-Uk;Cho, Su-Eog;Park, Sung-Jun;Kim, Dong-Ok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.63-69
    • /
    • 2008
  • The position of stator is essential when a trapezoidal BLDC motor is drived. In this paper we proposed a novel sensorless drive system for the trapezoidal BLDC motor without hall sensors or encoders. The resistor Y-connecting method is used to obtain Back-emf of a trapezoidal BLDC motor. Especially, by using the new Back-emf filter circuit proposed in this paper the sensorless characteristic in low speed is improved. The prototype proposed system applied for a 100[W] rating BLDC motor is made and the propriety of the Back-EMF filter circuit is also verified.

Three-Phase Line-Interactive Dynamic Voltage Restorer with a New Sag Detection Algorithm

  • Jeong, Jong-Kyou;Lee, Ji-Heon;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • v.10 no.2
    • /
    • pp.203-209
    • /
    • 2010
  • This paper describes the development of a three-phase line-interactive DVR with a new sag detection algorithm. The developed detection algorithm has a hybrid structure composed of an instantaneous detector and RMS-variation detectors. The source voltage passes through the sliding-window DFT and RMS calculator, and the instantaneous sag detector. If an instantaneous sag is detected, the RMS variation detector-1 is selected to calculate the RMS variation. The RMS variation detector-2 is selected when the instantaneous sag occurs under the operation of the RMS variation detector-1. The feasibility of the proposed algorithm is verified through computer simulations and experimental work with a prototype of a line-interactive DVR with a 3kVA rating. The line-interactive DVR with the proposed algorithm can compensate for an input voltage sag or an interruption within a 2ms delay. The developed DVR can effectively compensate for a voltage sag or interruption in sensitive loads, such as computers, communications equipment, and automation equipment.

DSP Based Series-Parallel Connected Two Full-Bridge DC-DC Converter with Interleaving Output Current Sharing

  • Sha, Deshang;Guo, Zhiqiang;Lia, Xiaozhong
    • Journal of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.673-679
    • /
    • 2010
  • Input-series-output-parallel (ISOP) connected DC-DC converters enable low voltage rating switches to be used in high voltage input applications. In this paper, a DSP is adopted to generate digital phase-shifted PWM signals and to fulfill the closed-loop control function for ISOP connected two full-bridge DC-DC converters. Moreover, a stable output current sharing control strategy is proposed for the system, with which equal sharing of the input voltage and the load current can be achieved without any input voltage control loops. Based on small signal analysis with the state space average method, a loop gain design with the proposed scheme is made. Compared with the conventional IVS scheme, the proposed strategy leads to simplification of the output voltage regulator design and better static and dynamic responses. The effectiveness of the proposed control strategy is verified by the simulation and experimental results of an ISOP system made up of two full-bridge DC-DC converters.

Fundamental Output Voltage Enhancement of Half-Bridge Voltage Source Inverter with Low DC-link Capacitance

  • Elserougi, Ahmed;Massoud, Ahmed;Ahmed, Shehab
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.116-128
    • /
    • 2018
  • Conventionally, in order to reduce the ac components of the dc-link capacitors of the two-level Half-Bridge Voltage Source Inverter (HB-VSI), high dc-link capacitances are required. This necessitates the employment of short-lifetime and bulky electrolytic capacitors. In this paper, an analysis for the performance of low dc-link capacitances-based HB-VSI is presented to elucidate its ability to generate an enhanced fundamental output voltage magnitude without increasing the voltage rating of the involved switches. This feature is constrained by the load displacement factor. The introduced enhancement is due to the ac components of the capacitors' voltages. The presented approach can be employed for multi-phase systems through using multi single-phase HB-VSI(s). Mathematical analysis of the proposed approach is presented in this paper. To ensure a successful operation of the proposed approach, a closed loop current controller is examined. An expression for the critical dc-link capacitance, which is the lowest dc-link capacitance that can be employed for unipolar capacitors' voltages, is derived. Finally, simulation and experimental results are presented to validate the proposed claims.