• 제목/요약/키워드: Rating Power

검색결과 516건 처리시간 0.029초

Dynamic Thermal Rating of Overhead Transmission Lines Based on GRAPES Numerical Weather Forecast

  • Yan, Hongbo;Wang, Yanling;Zhou, Xiaofeng;Liang, Likai;Yin, Zhijun;Wang, Wei
    • Journal of Information Processing Systems
    • /
    • 제15권4호
    • /
    • pp.724-736
    • /
    • 2019
  • Dynamic thermal rating technology can effectively improve the thermal load capacity of transmission lines. However, its availability is limited by the quantity and high cost of the hardware facilities. This paper proposes a new dynamic thermal rating technology based on global/regional assimilation and prediction system (GRAPES) and geographic information system (GIS). The paper will also explore the method of obtaining any point meteorological data along the transmission line by using GRAPES and GIS, and provide the strategy of extracting and decoding meteorological data. In this paper, the accuracy of numerical weather prediction was verified from the perspective of time and space. Also, the 750-kV transmission line in Shaanxi Province is considered as an example to analyze. The results of the study indicate that dynamic thermal rating based on GRAPES and GIS can fully excavate the line power potential without additional cost on hardware, which saves a lot of investment.

동력전달용 베벨기어의 강도평가 시스템 개발 연구 (Development of Rating Systems for Power Transmission Bevel Gears)

  • 정태형;지중조;변준형
    • 한국정밀공학회지
    • /
    • 제12권7호
    • /
    • pp.66-73
    • /
    • 1995
  • Rating systems of bevel gears(straight, spiral, and zerol bevel gears) which are commonly used as power transmission devices for non-papallel axes are developed on the personal computer, which analyze and/or evaluate the gear design and the service performance at the point of view of strength and durability. The typical considerations of the ratings are the bending strength, the surface durability, and the scoring resistance. The ratings are carried out using the reliable standards of AGMA & Gleason Works. Therefore, the system is built so that the variables or factors considered differently in those standards and the strength, dura- bility, and scoring partially in Gleason are appraised seperately by each method, and a series of the estimation processes is integrated into the system so as to compare each result. The developed rating systems can be used in the initial stage of gear design process, and also a better design can be performed by the evaluation of the initial design at the view point of gear strength and durability. Additionally, it is useful for the trouble-shooting of bevel gear system and to the purpose of introducing the methods for maintaining design strength in service, with appraising the gear strength after design or with appraising the influencing factor as a whole. Therefore, this rating systems can help the aim of design automation of bevel gears.

  • PDF

Analysis, Design, and Implementation of a Single-Phase Power-Factor Corrected AC-DC Zeta Converter with High Frequency Isolation

  • Singh, Bhim;Agrawal, Mahima;Dwivedi, Sanjeet
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.243-253
    • /
    • 2008
  • This paper deals with the analysis, design, and implementation of a single phase AC-DC Zeta converter with high frequency transformer isolation and power factor correction(PFC) in two modes of operation, discontinuous current mode of operation(DCM), and continuous current mode of operation(CCM). A Digital Signal Processor(DSP) based implementation is carried out for validation of the Zeta converter developed design in discontinuous mode of operation. A comparison of both modes of operation is presented for a 1kW power rating from the point of view of steady state and dynamic behavior, power quality, simplicity, control technique, device rating, and converter size. The experimental results of a developed prototype of Zeta converter are presented for validation of the developed design. It is observed that CCM is most suitable for higher power applications where it requires some complex control and sensing of the additional variables.

MMC 기반 HVDC 전력변환기의 밸브 성능 시험회로 (Performance Test Circuit for a Valve of MMC Based HVDC Power Converter)

  • 배치환;조광래;김학수;노의철
    • 전력전자학회논문지
    • /
    • 제28권1호
    • /
    • pp.76-81
    • /
    • 2023
  • A new test circuit for an MMC-based valve HVDC power converter is proposed. The proposed scheme satisfies the required clauses from IEC-62501. The valve test current contains second harmonic component and DC offset as well as a fundamental component that is quite similar to the real operating arm current of MMC based HVDC power system. The structure of the proposed test circuit is simple compared to conventional test circuits. Furthermore, the power supply voltage rating of the proposed test circuit is reduced dramatically around 20% of the conventional scheme with the same current rating. The validity of the proposed test circuit is verified through simulation and experimental results.

Interleaved ZVS DC/DC Converter with Balanced Input Capacitor Voltages for High-voltage Applications

  • Lin, Bor-Ren;Chiang, Huann-Keng;Wang, Shang-Lun
    • Journal of Power Electronics
    • /
    • 제14권4호
    • /
    • pp.661-670
    • /
    • 2014
  • A new DC/DC converter with zero voltage switching is proposed for applications with high input voltage and high load current. The proposed converter has two circuit modules that share load current and power rating. Interleaved pulse-width modulation (PWM) is adopted to generate switch control signals. Thus, ripple currents are reduced at the input and output sides. For high-voltage applications, each circuit module includes two half-bridge legs that are connected in series to reduce switch voltage rating to $V_{in}/2$. These legs are controlled with the use of asymmetric PWM. To reduce the current rating of rectifier diodes and share load current for high-load-current applications, two center-tapped rectifiers are adopted in each circuit module. The primary windings of two transformers are connected in series at the high voltage side to balance output inductor currents. Two series capacitors are adopted at the AC terminals of the two half-bridge legs to balance the two input capacitor voltages. The resonant behavior of the inductance and capacitance at the transition interval enable MOSFETs to be switched on under zero voltage switching. The circuit configuration, system characteristics, and design are discussed in detail. Experiments based on a laboratory prototype are conducted to verify the effectiveness of the proposed converter.

발전소 주변압기 운전중 진동 기준치 설정에 관한 연구

  • 이욱륜;이준신
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.587-592
    • /
    • 2005
  • Main transformer's integrity assessment in nuclear power plant is estimated by the electrical test of electrical core and wire and the chemical analysis of insulating oil. Mechanical test or analysis has not been so far. So this study makes it with the vibration velocity rating. The vibration velocity rating in main transformer which is based on the real data of vibration velocity measurement under operating and other machinery vibration code such as ISO code is renewed.

  • PDF

순시 정격을 고려한 유도기 경량화에 관한 연구 (A study on lightening the weight of an induction motor satisfying maximum power rating)

  • 박정태;이철균;김종구;정현교;원종수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.162-164
    • /
    • 1994
  • This paper presents the optimal design method of an induction motor for electric vehicle which minimizes the weight of motor and satisfies maximum power rating at the same time. Effects of motor parameters on the dimensions and weight of motor is investigated. Optimal routine which is used in this paper is simulated annealing technique.

  • PDF

고압계통 변류기 동작 특성 검토 (A Study on Performance of Current Transformer in High Voltage System)

  • 최기열;이덕수;박문빈;김희택;장기풍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.5-7
    • /
    • 2006
  • Current transformers(CTs) whose rating is selected per a full load current of a feeder in high voltage system can be easily saturated due to high fault current that may be several hundred times of the full load current of the feeder. However, the protective relay shall operate properly at the fault without mis-operation under the CT saturation. So, in selecting the CT rating, it is necessary to consider the behaviour of CT and a performance of protection scheme in condition where CT can be saturated. In this paper, a performance of CT and a degree of saturation are studied and verified whether its ratings are proper for the operation of the protective relay.

  • PDF

SRM 구동을 위한 새로운 ZVT-PWM 컨버어터 (Novel Zero Voltage Transition PWM Converter for Switched Reluctance Motor Drives)

  • 김원호;김종수;조정구;임근희;김철우
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권8호
    • /
    • pp.455-460
    • /
    • 1999
  • A novel zero-voltage-transition (ZVT) PWM converter for switched reluctance motor (SRM) drives is proposed. A simple auxiliary circuit which consists of one active switch, one resonant inductor, and three diodes provides ZVS condition to all main switches and diodes allowing high frequency operation of the converter with high efficiency. The auxiliary circuit is placed in parallel with the main power flow path and thus it handles only a small fraction of the main power. So, the power rating of the auxiliary circuit can be very small (about 30% of main power). So, the auxiliary circuit can be realized with small power rating and low cost. Operation, features and characteristics of the proposed converter are illustrated and verified on a 1.5 kW, 50 kHz IGBT based (a MOSFET for the auxiliary with) experimental circuit.

  • PDF