• Title/Summary/Keyword: Range of variation

Search Result 3,245, Processing Time 0.048 seconds

Study on the new approaching method to determine limit of detection by gas chromatography (GC에서 검출한계 결정을 위한 새로운 접근 방법에 대한 연구)

  • Oh, Doe-Suk;Shin, Kyoung-Ae;Lee, Ji-A;Lym, Jong-Ho;Shin, Mi-Sun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.4
    • /
    • pp.217-224
    • /
    • 2010
  • The purity methods to determine LOD/LOQ using standard deviation of the residual, intercept and blank by IUPAC and ACS describe many of the pitfalls and pose significant challenges to analytical chemists. Therefore, the aim of this study is the development of the simple, easy, convenient and statistically significant method to determine LOD in quantitative analysis of organic solvents by GC. The new approaching method by linearization in the given concentration range used coefficient of variation ; ${\sigma}_{n-1}$/S(standard deviation, ${\sigma}_{n-1}$ and average, S) of sensitivity(Response/concentration). The comparison of results among the purity methods(IUPAC and ACS) and the linearization have been fulfilled the F-test for standard deviations and t-test for LOD range values. The results of F-test and t-test are satisfied within 95 % confidence level, respectably. The LOD values determined by the new procedure are n-Hexane 0.0116 mg/$m^3$, Toluene 0.0807 mg/$m^3$, and o-Xylene 0.0494 mg/$m^3$. Because the standard deviation of the residual, intercept and blank and the slope of calibration curve are not calculated and the new approaching method use the coefficient of variation of sensitivity by linearization, this new method is simple, easy, convenient and statistically significant. In future, many chemical analysts will expect to applicate and routinely use this method in the all quantitative analysis.

A study on suspension state matrix to improve load/unload performance (로드/언로드 성능향상을 위한 서스펜션 상태행렬 연구)

  • Lee, Yong-Hyun;Kim, Ki-Hoon;Kim, Seok-Hwan;Park, No-Cheol;Park, Young-Pil;Park, Kyoung-Su;Kim, Cheol-Soon
    • Transactions of the Society of Information Storage Systems
    • /
    • v.5 no.1
    • /
    • pp.47-52
    • /
    • 2009
  • Most hard disk drives that apply the ramp load/unload technology unload the heads at the outer edge of the disk while the disk is rotating. The load/unload includes the benefits as like an increased areal density, a reduced power consumption and an improved shock resistance. A lot of papers investigating the effects of the various load/unload parameters such as a suspension tab, a limiter, a ramp and air-bearing surface designs have been published. However, in previous researches, an effect of the suspension is not considered at each load/unload step. In this paper, we focus that a variation of the state matrix affects the load/unload performance on based on a state matrix that is a stiffness matrix of the suspension. Because the state matrix is related to the suspension at each load/unload step, to change the state matrix means the structural change of the suspension. Therefore, we investigated a range of a pitch static attitude(PSA) and a roll static attitude(RSA) for load/unload performance. We also analyzed an effect of the variation of the state matrix a range of load/unload velocity occurred a slider-disk contact. We determined the variation of the state matrix to improve the load/unload performance through comparison of each factor of state matrix.

  • PDF

Cyclic Change of Phytoplankton Community in Mankyeong River Estuary prior to the Completion of the Saemankeum Seawall (새만금 방조제 완공 이전 만경강 하구역 식물플랑크톤 군집의 주기적인 변동)

  • Kim, Young-Geel;Park, Jong-Woo;Jang, Keon-Gang;Yih, Won-Ho
    • Ocean and Polar Research
    • /
    • v.31 no.1
    • /
    • pp.63-70
    • /
    • 2009
  • Eutrophicated water fed through Mankyeong River and Dongjin River into the new Saemankeum Lakemight seriously affect the water quality and phytoplankton community in the lake. To obtain control reference data for the later studies on environmental changes due to the construction of the Saemankeum Sea Wall, we performed a monthly investigation on the physico-chemical properties of the water and phytoplankton community at 3 stations in the Mankyeong River Estuary over 14 months starting from September 1999. Water temperature ranged from $0.3{\sim}32.9^{\circ}C$ due to the typical seasonal variations in temperate on the coasts and salinity exhibited a wide annual range of $0.2{\sim}33.7$ psu along with regular and huge hourly variations according to tidal cycles. Inorganic nutrients were supplied from rivers to the monitoring station and the whole lake. The average concentration of total-N, $6.99\;mg{\cdot}l^{-1}$, was higher than the water quality for agricultural use with peak values occurring in winter. Species composition showed a seasonal succession pattern, where a high diversity was observedin summer and autumn and vice versa in winter. Hourly variations of water properties in the "Mankyeong bridge" Station were quite regular and well in accordance with the daily tidal cycles. The different degree of sea water intrusion during the flood tide at each of the 3 stations exhibited a different range and variation pattern of water temperature and salinity throughout a day. Hourly changes in species composition were in harmony with the daily tidal cycles, resulting in extremely variable spatio-temporal variation.

Implementation of Broadband Printed Sleeve Monopole Antenna (광대역 프린티드 슬리브 모노폴 안테나의 구현)

  • Choe, Gwang-Je;Kang, Sang-Won
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.6
    • /
    • pp.245-250
    • /
    • 2014
  • This paper presents the broadband printed sleeve-monopole antenna implementing the sleeve monopole structure in the form of PCB. In the proposed antenna, the antenna performance was improved by the diameter variation of the radiator, the length variation of the sleeve, and the variation of the diameter of the sleeve conductor. HFSS simulator of ANSYS corp. was used in order to confirm the antenna parameter characteristic. According to the simulation results, the VSWR was less than 2 for the range of 2.12GHz~3.18GHz. The frequency bandwidth is 1.08GHz. The frequency range of the actual fabricated antenna was 2.0GHz~3.55GHz, the frequency bandwidth is 1.55GHz. The maximum gain was 1.64dBi. The proposed antenna was $56{\times}5{\times}1.6mm$ in size. The utilization possibility of the broadband printed sleeve-monopole antenna could be confirmed according to compare and analyze the simulation and measurement data.

A V-I Converter Design for Power Variation Insensitivity PLL (전원 전압 변화에 둔감한 PLL을 위한 V-I 변환기 설계)

  • Lee, Hyun-Seok;Hong, Dong-Hee;Park, Jong-Wook;Lim, Shin-Il;Sung, Man-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.3 s.357
    • /
    • pp.59-64
    • /
    • 2007
  • This paper describes the PLL of TCON(Timing Controller) chip for FPD(Flat Panel Display). We propose a new V-I converter which is insensitive to the power supply variation when it is applied to the TCON. The new V-I converter compensated the output frequency of VCO by appling the current that is inversely proportional to the voltage variation. The proposed idea is implemented with a 1-ploy 3-metal 0.25m TSMC CMOS technology and has the output frequency range from 192MHz to 360MHz at the supply voltage of 2.5V. Measurement result shows the RMS jitter of 100ps in the above output frequency range.

Microstructure Evolution of Superalloy Nimonic 80A (초내열합금 Nimonic 80A의 미세조직 변화에 관한 연구)

  • Jeong H. S.;Cho J. R.;Park H. C.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.05a
    • /
    • pp.174-177
    • /
    • 2004
  • The nickel-based alloy Nimonic 80A possesses strength, and corrosion, creep and oxidation resistance at high temperature. These products are used for aerospace, marine engineering and power generation, etc. The control of forging parameters such as strain, strain rate, temperature and holding time is important because the microstructure change in hot working affects the mechanical properties. It is necessary to understand the microstructure variation evolution. The microstructure change evolution occurs by recovery, recrystallization and grain growth phenomena. The dynamic recrystallization evolution has been studied in the temperature range $950-1250^{\circ}C$ and strain rate range $0.05-5s^{-1}$ using hot compression tests. The metadynamic recrystallization and grain growth evolution has been studied in the temperature range $950-1250^{\circ}C$ and strain rate range 0.05, $5s^{-1}$, holding time range 5, 10, 100, 600 sec using hot compression tests. Modeling equations are developed to represent the flow curve, recrystallized grain size, recrystallized fraction and grain growth phenomena by various tests. Parameters of modeling equation are expressed as a function of the Zener-Hollomon parameter. The modeling equation for grain growth is expressed as a function of initial grain size and holding time.

  • PDF

Low Phase Noise CMOS VCO with Hybrid Inductor

  • Ryu, Seonghan
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.3
    • /
    • pp.158-162
    • /
    • 2015
  • A low phase noise CMOS voltage controlled oscillator(VCO) for multi-band/multi-standard RF Transceivers is presented. For both wide tunability and low phase noise characteristics, Hybrid inductor which uses both bondwire inductor and planar spiral inductor in the same area, is proposed. This approach reduces inductance variation and presents high quality factor without custom-designed single-turn inductor occupying large area, which improves phase noise and tuning range characteristics without additional area loss. An LC VCO is designed in a 0.13um CMOS technology to demonstrate the hybrid inductor concept. The measured phase noise is -121dBc/Hz at 400KHz offset and -142dBc/Hz at 3MHz offset from a 900MHz carrier frequency after divider. The tuning range of about 28%(3.15 to 4.18GHz) is measured. The VCO consumes 7.5mA from 1.3V supply and meets the requirements for GSM/EDGE and WCDMA standard.

CT-based quantitative evaluation of radiation-induced lung fibrosis: a study of interobserver and intraobserver variations

  • Heo, Jaesung;Cho, Oyeon;Noh, O Kyu;O, Young-Taek;Chun, Mison;Kim, Mi-Hwa;Park, Hae-Jin
    • Radiation Oncology Journal
    • /
    • v.32 no.1
    • /
    • pp.43-47
    • /
    • 2014
  • Purpose: The degree of radiation-induced lung fibrosis (RILF) can be measured quantitatively by fibrosis volume (VF) on chest computed tomography (CT) scan. The purpose of this study was to investigate the interobserver and intraobserver variability in CT-based measurement of VF. Materials and Methods: We selected 10 non-small cell lung cancer patients developed with RILF after postoperative radiation therapy (PORT) and delineated VF on the follow-up chest CT scanned at more than 6 months after radiotherapy. Three radiation oncologists independently delineated VF to investigate the interobserver variability. Three times of delineation of VF was performed by two radiation oncologists for the analysis of intraobserver variability. We analysed the concordance index (CI) and inter/intra-class correlation coefficient (ICC). Results: The median CI was 0.61 (range, 0.44 to 0.68) for interobserver variability and the median CIs for intraobserver variability were 0.69 (range, 0.65 to 0.79) and 0.61(range, 0.55 to 0.65) by two observers. The ICC for interobserver variability was 0.974 (p < 0.001) and ICCs for intraobserver variability were 0.996 (p < 0.001) and 0.991 (p < 0.001), respectively. Conclusion: CT-based measurement of VF with patients who received PORT was a highly consistent and reproducible quantitative method between and within observers.

Variation Analysis of CO2 Concentrations at Sunset before and after of Summer Season at the Foreshore (갯벌에서 여름철 일몰 전후 이산화탄소 농도 변동 분석)

  • Kang, Dong Hwan;Kwon, Byung Hyuk;Kim, Park Sa
    • Journal of Environmental Science International
    • /
    • v.23 no.3
    • /
    • pp.399-407
    • /
    • 2014
  • In this study, before and after sunset carbon dioxide concentration and air temperature were observed in two points of atmosphere (lower observation point of the GL + 0.1 m, the upper observation point of GL + 1.0 m) on the foreshore at located in Suncheon Bay and their variations were analyzed. Observation was performed on the foreshore on 2~4 August 2010. Instrument (VAISALA, GMP343) was set two hours before sunset and then observation was made continuously for six hours. In three days, observed carbon dioxide concentration was 375~419 ppm, and the air temperature was in the range of $28.7{\sim}32.5^{\circ}C$. The average concentration of carbon dioxide was 388~399 ppm in the upper observation point and 386~396 ppm in the lower observation point. It was higher in the upper observation point and its fluctuations were similar in two observation points. Correlation coefficients between carbon dioxide concentration and air temperature in the upper observation point were in the range of -0.64~-0.88, and were calculated -0.65 to -0.90 in the lower observation point. For the carbon dioxide concentration, correlation coefficients between the upper part and the lower part were very high as 0.98 in three times. For the air temperature, correlation coefficients between the upper part and the lower part were very high as 0.97 and 0.99. In the same observation time, the slope of the linear regression function as carbon dioxide concentration in the lower observation point for the upper observation point was in the range of 0.97~1.01. Carbon dioxide concentration was slightly higher in the upper observation point. Because carbon dioxide in the lower observation point was closer on the surface of the foreshore and absorbed from atmosphere to the foreshore. In this study, it was showed that the vertical variation of carbon dioxide concentration was insignificant in the several meter scale of atmosphere on the surface of the foreshore.

Effect of Piezoactuator Length Variation for Vibration Control of Beams (보의 진동제어를 위한 압전 액추에이터의 길이변화 효과 연구)

  • Lee, Young-Sup
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.442-448
    • /
    • 2008
  • This paper presents an approach to define an optimal piezoactuator length to actively control structural vibration. The optimal ratio of the piezoactuator length against beam length when a pair of piezoceramic actuator and accelerometer is used to suppress unwanted vibration with direct velocity feedback (DVFB) control strategy is not clearly defined so far. It is well known that direct velocity feedback (DVFB) control can be very useful when a pair of sensor and actuator is collocated on structures with a high gain and excellent stability. It is considered that three different collocated pairs of piezoelectric actuators (20, 50 and 100 mm) and accelerometers installed on three identical clamped-clamped beams (300 * 20 * 1 mm). The response of each sensor-actuator pair requires strictly positive real (SPR) property to apply a high feedback gain. However the length of the piezoactuator affects SPR property of the sensor-actuator response. Intensive simulation and experiment shows the effect of the actuator length variation is strongly related with the frequency range of SPR property. A shorter actuator gave a wider SPR frequency range as a longer one had a narrower range. The shorter actuator showed limited control performance in spite of a higher gain was applied because the actuation force was relatively small. Thus an optimal length ratio (actuator length/beam length) was suggested to obtain relevant performance with good stability with DVFB strategy. The result of this investigation could give important information in the design of active control system to suppress unwanted vibration of smart structures with piezoelectric actuators and accelerometers.

  • PDF