• Title/Summary/Keyword: Range control

Search Result 7,858, Processing Time 0.044 seconds

Effect of D-Range Neutral Control of Automatic Transmission on LA-4 Mode Fuel Economy (정지구간에서 자동변속기 D단 중립 제어가 LA-4 모드 주행 연비에 미치는 영향)

  • Wi, Hyo-Seong;Jung, Youn-Sik;Park, Jin-Il;Park, Kyoung-Seok;Lee, Jong-Hwa
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.1
    • /
    • pp.19-23
    • /
    • 2009
  • This paper focuses on vehicle fuel economy improvement using D-Range neutral control of automatic transmission. The system objected to reducing of fuel consumption during idle. Usually, turbine of conventional auto transmission is mechanically linked to wheel during idling condition. Therefore speed ratio of torque converter is zero for that period. This causes needless power loss by the torque converter slip. To improve this inefficiency automobile makers develops electronically-controlled D-range neutral control system. The D-range neutral control system minimizes slip on the torque converter by shifting gear to a neutral position during vehicle stoped with D-range gear position. However there's insufficient study about the effect of D-range neutral control system on vehicle fuel economy. In this paper, researches are performed on effect of D-range neutral control system on vehicle fuel economy by experiment with two different vehicle. And it is also estimated the effect on vehicle fuel economy using computer simulation. As a result, 1.8% of LA-4 mode fuel economy improvement can be achieved in a vehicle by D-range neutral control system.

Study of Flow Control Range according to Valve Type (밸브 형식별 유량제어범위 결정에 관한 연구)

  • Park, Jong-Ho;Park, Han-Yung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.5
    • /
    • pp.39-47
    • /
    • 2011
  • Flow control range of valve, which is installed on pipeline, varies according to valve type, pipe diameter, pipe length, roughness, and elevation difference of both ends of pipeline. A lot of computation efforts and knowledge are needed to estimate flow control range of valve, considering above many parameters. The table of flow control range of each valve type is presented for convenience of pipeline design engineers who must make decision of valve size and type in this study. Also the reason that butterfly valve is recommended for flow control, and gate valve is forbidden is presented via quantification and figures in this study.

Empirical Study on Stereotype for Burner-Control Relationship of Four-Stove Gas Range for Koreans

  • Kee, Do-Hyung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.3
    • /
    • pp.463-467
    • /
    • 2012
  • This study aims to empirically investigate population stereotype of burner-control linkage of four-stove gas range for Koreans. Background: The previous studies' results for gas range stereotypes were different depending upon methods adopted, i.e., whether using questionnaires, computer simulation or physical models. It is known that the physical model experiment should not be methodologically replaced by the computer simulation or paper-and-pencil tests. Stereotype of gas range for Koreans was surveyed based on questionnaires, but has not been dealt with by using physical models. Method: An experiment was conducted to investigate stereotype of four-burner gas range, in which 32 subjects participated and a real gas range available in the market was bought and used. Four types of burner-control linkage were used as independent variable, and reaction time as dependent variable. Results: ANOVA revealed that four types of burner-control linkage and subjects' gender were not significant on reaction time. Duncan's multiple range test showed that reaction times for type III was significantly lower than those for the other three types of burner-control linkage(${\alpha}$=0.05). Conclusion: It is concluded based on the results of this study that stereotype of gas range for Koreans is type III. This is in agreement with results of existing studies using questionnaire survey, while different from those based on physical models. Application: The results of this study would be useful as an ergonomic guideline when designing gas ranges or similar equipments for minimizing operation errors.

A Modified Weighted Least Squares Range Estimator for ASM (Anti-Ship Missile) Application

  • Whang Ick-Ho;Ra Won-Sang;Ahn Jo-Young
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.3
    • /
    • pp.486-492
    • /
    • 2005
  • A practical recursive WLS (weighted least squares) algorithm is proposed to estimate relative range using LOS (line-of-sight) information for ASM (anti-ship missile) application. Apart from the previous approaches based on the EKF (extended Kalman filter), to ensure good convergence properties in long range engagement situations, the proposed scheme utilizes LOS rate measurements instead of conventionally used LOS angle measurements. The estimation error property for the proposed filter is investigated and a simple error compensator is devised to enhance its estimation error performances. Simulation results indicate that the proposed filter produces very accurate range estimates with extremely small computations.

Motion Control of an Outdoor Patrol Robot using a Single Laser Range Finder (야외 순찰로봇을 위한 단일 레이저거리센서 기반 충돌 회피 주행 제어기법 개발)

  • Hong, Seung-Bohm;Shin, You-Jin;Chung, Woo-Jin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.4
    • /
    • pp.361-367
    • /
    • 2010
  • This paper reports the development of a mobile robot for patrol using a single laser range finder. A Laser range finder is useful for outdoor environment regardless of illumination change or various weather conditions. In this paper we combined the motion control of the mobile robot and the algorithm for detecting the outdoor environment. For obstacle avoidance, we adopted the Vector Field Histogram algorithm. A laser range finder is mounted on the mobile robot and looking down the road with a small tilt angle. We propose an algorithm for detecting the surface of the road. The outdoor patrol robot platform is equipped with a DGPS system, a gyro-compass sensor, and a laser range finder. The proposed obstacle avoidance and road detection algorithms were experimentally tested in success.

A Stable Sensorless Speed Control for Induction Motor in the Overall Range (전영역에서 안정된 유도전동기의 센서리스 속도제어)

  • 김종수;김성환;오세진
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.641-647
    • /
    • 2004
  • By most sensorless speed control schemes for induction motor. the control performances in high speed range are good, but it is difficult to obtain satisfactory results in low speed region. This paper proposes a new method controlling the low and the high speed regions separately to attain the stable operation in the overall range. The current error compensation method, in which the controlled stator voltage is applied to the induction motor so that the error between stator currents of the numerical model and the actual motor can be forced to decay to zero as time proceeds. is used in the low speed region In the high speed region. the method with adaptive observer is utilized. This control strategy contains an adaptive state observer for flux estimation. The rotor speed can be calculated from the rotor flux and the motor currents. The experimental results indicate good speed and load responses from the very low speed range to the high, and also show accurate speed changing performance between the low and the high speed range.

Swing-up Control for a Rotary Inverted Pendulum with Restricted Rotation Range (회전변위 제약을 갖는 회전용 도립진자의 스윙업 제어)

  • Lee, Y.S.;Oh, J.J.;Shim, S.Y.;Lim, H.;Seo, J.H.
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.6
    • /
    • pp.548-553
    • /
    • 2008
  • In this paper, we propose a new swing-up control strategy for rotary inverted pendulums with restricted rotation range. The control law is derived from a Lyapunov function. The Lyapunov function is defined as the square of the sum of the absolute value of the total mechanical energy and weighted squares of the arm's angular displacement and velocity. By adjusting the weighting parameters in the Lyapunov function, we can affect the swing-up strategy such that the restriction on rotation range can be satisfied. Finally, we verify the performance of the proposed control law through simulation and experiments.

Swing up Control for a rotary pendulum with restricted rotation range (회전변위 제약을 갖는 회진형 도립진자의 스윙업 제어)

  • Oh, Jang-Jin;Lee, Young-Sam
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.133-134
    • /
    • 2007
  • A swing-up control strategy is suggested for a rotary inverted pendulum with restricted rotation range. In order to take the rotation range limitation into account, a new Lyapunov function used for energy-based control is proposed a control strategy is derived from the Lyapunov function. Futhermore, optimization-base parameter estimation is adopted to get an exact mathematical model for the pendulum. Simulation results show that the proposed control strategy swings up the rotary inverted pendulum efficiently.

  • PDF

Radioimmunoassay Using Quality Control Materials BIO-RAD of the Suggestions for Setting Acceptable Range (BIO-RAD 정도관리 물질을 이용한 방사면역측정법의 Acceptable Range 설정에 대한 제언)

  • Park, Hee-Won;Kim, Tae-Hoon;Roh, Gyeong-Un;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.108-114
    • /
    • 2012
  • Purpose: Immunosorbent assay most commonly used in the laboratory and commercial third-party quality control material is a substance that provided by BIO-RAD. However, in Reference Sheet by radioimmunoassay test kit or a measuring device for the mention of Acceptable Range is somewhat lacking. Radioimmunoassay for the inspection of test results by setting Acceptable Range to increase the objectivity of the recommendations on the data accumulated by the manufacturer listed in the Reference Sheet is to be issued. Materials and Methods : In our hospital since 2009 partially BIO-RAD using quality control materials in 2011, excluding certain items, some items were most of the BIO-RAD third-party quality control materials are used. Thus, internal quality control data accumulated BIO-RAD's Unity Real Time program by using the items were measured. Results : BIO-RAD using quality control material items were about 50 of the 20 Point Data averages, standard deviations, variation coefficients were calculated to measure the Acceptable Range of kit, automated immunoassay attributed Roche Elecsys / E170 / cobas e Systems the measures and compared. Conclusions : BIO-RAD QC materials commonly used hospital and peer group by setting the measurement kit, suitable for laboratory equipment for radioimmunoassay of Acceptable Range manufacturer recommendation to increase the objectivity of the test results by national and international recognition for radioimmunoassay should seek to increase.

  • PDF

A Common Capacitor Connected LLC Resonant Converter with Auxiliary Switches Operating Over a Wide Output Voltage Control Range (넓은 출력전압 제어범위에서 동작하는 보조스위치 적용 공통커패시터 연결 LLC 공진컨버터)

  • Oh, Jae-Sung;Kim, Min-Ji;Lee, Ji-Cheol;Kim, Eun-Soo;Jeon, Yong-Seog;Kook, Yoon-Sang
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.4
    • /
    • pp.294-302
    • /
    • 2019
  • A capacitor common connected LLC resonant converter with auxiliary switches for a wide output voltage control range is presented in this paper. The proposed converter can be controlled in two ways to achieve a wide output voltage control range of Vo-3Vo. The first control method is performed through pulse width modulation of the auxiliary switches and primary switching devices. The second control method is conducted through frequency modulation of the primary switching devices configured to operate in full-bridge switching modes, when the auxiliary switches are turned off. The feasibility of the proposed converter is verified by the experimental results of a 5 kW prototype.