• Title/Summary/Keyword: Range Sensor

Search Result 2,603, Processing Time 0.025 seconds

Development of ROM Measurement Device capable of IoT-based Real-time Monitoring for Rehabilitation Patients (재활환자를 위한 IoT 기반의 실시간 모니터링이 가능한 ROM 측정 장치 개발)

  • Kang, Min-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.4
    • /
    • pp.111-116
    • /
    • 2018
  • In this thesis, the range of motion of the joint was measured using a flexible sensor without using a goniometer, and the measured values were transferred to a smart device. Current range of joint motion measurement is measured by a person using a goniometer. Since the method of measuring by a person is different according to the measuring method and position of the measuring person, it is difficult to make consistent measurement, and an error may occur. The sensor for measurement is a flexible sensor that measures the resistance value that changes according to the movement of the joint. The sensed value can be transmitted to the smart device wirelessly through the ROM sensor node. Also, the sensed analog values were converted to digital values using an ADC. The converted value can be transmitted to the smart device wirelessly through the sensor node. The developed ROM measuring device can perform more consistent measurement than the measurement using general articulator and real time monitoring by interlocking with smart device, so that rapid diagnosis according to the movement of the joint can help the patient's rapid treatment and rehabilitation medical advancement will be.

Fabrication and Characteristics of Hot-film Air Flow Sensor for Automobile (자동차용 박막 히터형 공기유량센서의 제작 및 특성)

  • Kim, Hyung-Pyo;Park, Se-Kwang
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.5
    • /
    • pp.394-399
    • /
    • 1999
  • An automobile hot-film air flow sensor is deposited with platinum by sputtering method, patterned by photoresisted lift-off method, annealed in $1,000^{\circ}C$ and passivated with PI-2723. The TCR of the fabricated hot-film is about $3500\;ppm/^{\circ}C$. In the experiment, the output voltage of the sensor is in proportional to the fourth power root in the air mass flow range of 300 kg/h. The error in the full flow range is about ${\pm}0.7%$. In the range of air temperature of $-20^{\circ}C{\sim}120^{\circ}C$, the error is about ${\pm}1%$ that is ${\pm}2%$ lower than that of the reference sensor. Therefore, the fabricated hot-film air flow sensor satisfies the specification for automobile. Lower temperature error of the sensor provides to control the precise air/fuel ratio of automobile engine and results in improvement of a fuel mileage and the less amount of toxic gases emitted by automobile.

  • PDF

Sensitivity of BOD Sensor with Heavy Metal Tolerant Serratia marcescens LSY4 (Serratia marcescens LSY4 중금속 내성주를 이용한 BOD센서의 감응도)

  • Kim Mal-Nam;Lee Sun-Young
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.3
    • /
    • pp.394-399
    • /
    • 2004
  • A BOD sensor was prepared with S. marcescens LSY4 and was applied for measurement of BOD values of a solution containing the standard organic pollutants. The sensor sensitivity was nearly independent of the culture time in the range of 9-16 hours. It was also affected little by the cell mass in the range of 0.22-0.75 mg $cm^{-2}$. A cyclic change in the solution pH in the range of 4-9 was accompanied by a reversible variation in the sensor sensitivity. However, the reversibility was lost when the solution pH became more acidic or more basic. Heavy metal ions lowered the sensor sensitivity, which took place more precipitously in the presence of $Cu^{2+}$ and $Ag^+$ rather than in the presence of $Zn^{2+}$ and $Cd^{2+}$. The reduction of the sensor sensitivity was significantly attenuated by loading heavy metal ion tolerance induced strain. The $Cu^{2+}$tolerance induced strain was more efficient for the attenuation than $Zn^{2+}$ and $Cd^{2+}$ tolerance induced strain.

Power-Aware Query Processing Using Optimized Distributed R-tree in Sensor Networks (센서 네트워크 환경에서 최적화된 분산 R-tree를 이용한 에너지 인식 질의 처리 방법)

  • Pandey Suraj;Eo Sang-Hun;Kim Ho-Seok;Bae Hae-Young
    • The KIPS Transactions:PartD
    • /
    • v.13D no.1 s.104
    • /
    • pp.23-28
    • /
    • 2006
  • In this paper, a power-aware query processing using optimized distributed R-tree in a sensor network is proposed. The proposed technique is a new approach for processing range queries that uses spatial indexing. Range queries are most often encountered under sensor networks for computing aggregation values. The previous work just addressed the importance but didn't provide any efficient technique for processing range queries. A query processing scheme is thus designed for efficiently processing them. Each node in the sensor network has the MBR of the region where its children nodes and the node itself are located. The range query is evaluated over the region which intersects the geographic location of sensors. It ensures the maximum power savings by avoiding the communication of nodes not participating over the evaluation of the query.

Multihop Range-Free Localization with Virtual Hole Construction in Anisotropic Sensor Networks (비등방성 센서 네트워크에서 가상 홀을 이용한 다중 홉 Range-Free 측위 알고리즘)

  • Lee, Sangwoo;Kim, Sunwoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.1
    • /
    • pp.33-42
    • /
    • 2013
  • This paper presents a multihop range-free localization algorithm to estimate the physical location of a normal node with local connectivity information in anisotropic sensor networks. In the proposed algorithm, a normal node captures the detour degree of the shortest path connecting an anchor pair and itself by comparing the measured hop count and the expected hop count, and the node estimates the distances to the anchors based on the detour degree. The normal node repeats this procedure with all anchor combinations and pinpoints its location using the obtained distance estimates. The proposed algorithm requires fewer anchors and less communication overhead compared to existing range-free algorithms. We showed the superiority of the proposed algorithm over existing range-free algorithms through MATLA simulations.

Implementation of an Integrated Pressure-sensor System Adapted to the Optimum Sensitivity

  • Hong, Sung-Hee;Cho, Chun-Hyung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.2
    • /
    • pp.186-191
    • /
    • 2017
  • An integrated pressure-sensor system was developed using the sensor-conditioning processes, which resulted in the optimum sensitivity of the pressure-sensor through the signal amplification, noise reduction, and level shift. Due to the specified characteristics among the components, such as operation range, the sensor output was generally limited compared to the full scale of the reading when coupled with other parts. Devices fabricated exhibited comparable characteristics with higher pressure sensitivity to that of the pressure sensor without sensor-conditioning process. In this work, the sensor resolution was at least enhanced at least by 25% using the sensor-conditioning processes.

Design and fabrication of IEEE-802.15.4 protocol based universal sensor node platform with good extensity (확장성이 고려된 IEEE-802.15.4 기반의 저전력 범용 센서노드 설계 및 제작)

  • Chung, Wan-Young;Shin, Kwang-Sig;Jang, Sung-Gyun
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.247-253
    • /
    • 2007
  • Low power consumption sensor network platform (sensor node) for sensor networking with IEEE 802.15.4 protocol was fabricated. The sensor node used ceramic bar type antenna for increasing RF signal performance and decreasing PCB size occupied by antenna. The communication range of the fabricated sensor node was about $20{\sim}30$ m in open environment with 915 MHz frequency bandwidth and well supported by Tiny OS. The sensor node have good connectivity with various external devices by RS-232, I2C, analogue and digital expansion board, hence, this sensor node can be applied to various applications in wireless sensor network and ubiquitous sensor network.

A Fast Localization Technique without Range Information in Wireless USB Services for Wearable Computer Systems (무선 USB 서비스 기반 웨어러블 컴퓨터 시스템의 Fast Range-Free 위치인식기법)

  • Hur, Kyeong;Sohn, Won-Sung
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.10
    • /
    • pp.1228-1235
    • /
    • 2012
  • In this Paper, we propose an energy efficient localization technique based on WUSB (Wireless USB) over WBAN (Wireless Body Area Networks) protocol required for Wearable Computer systems. For this purpose, the proposed localization algorithm minimizes power consumption and estimates location without range information. It is executed independently on the basis of WUSB over WBAN protocol at each sensor node comprising peripherals of a wearable computer system. And it minimizes power consumption by estimating locations of sensor nodes with range-free method fast.

Novel Tm(III) Membrane Sensor Based on 2,2'-Dianiline Disulfide and Its Application for the Fluoride Monitoring of Mouth Wash Preparations

  • Ganjali, Mohammad Reza;Norouzi, Parviz;Tamaddon, Atefeh;Husain, Syed Waqif
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.9
    • /
    • pp.1418-1422
    • /
    • 2006
  • In this work the construction of a novel poly(vinyl chloride) membrane sensor based on 2,2'-dianiline disulfide (DADS) as a neutral carrier, o-nitrophenyloctyl ether (NPOE) as a plasticizer and sodium tetraphenyl borate (NaTPB) as an anionic site with unique selectivity towards Tm(III) ions is reported. The electrode has a linear dynamic range between $1.0\;{\times}\;10^{-6}$ and $1.0\;{\times}\;10^{-2}$ M, with a nice Nernstian slope of 19.5 ${\pm}$ 0.3 mV per decade and a detection limit of $4.0\;{\times}\;10^{-7}$ M at the pH range of 4.8-8.5. It has a very fast response time (<15 s) in the whole concentration range, and can be used for at least 4 weeks without any considerable divergence in the electrode potentials. The proposed sensor revealed comparatively good selectivity with respect to most common metal ions, and especially lanthanide ions. It was used as an indicator electrode in the potentiometric titration of Tm(III) ions with EDTA and in direct determination of concentration of Tm(III) ions in binary mixtures. It was also applied in determination of fluoride ions in mouth wash preparations.

Development for Measurement Range Extension Technique of AC High Voltage Source using Parallel Plates Electrode and Electric Field Sensor (평행판 전극과 전기장 센서를 이용한 교류 고전압 발생원의 측정범위 확장기술 개발)

  • Kang, Jeon-Hong;Ryu, Jae-Cheon;Lee, Sang-Hwa;Kim, Kyu-Tae;Kim, Myung-Soo;Han, Sang-Ok;Jung, Jae-Kap
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.9
    • /
    • pp.446-451
    • /
    • 2006
  • The output voltage value of AC high voltage source has been usually measured by employing the high voltage divider of inductive or capacitive type. In the study, we have developed a new method for measuring the output voltage up to 60kV using parallel plates electrode and electric field sensor, which are constructed by home-made. Unlikely the conventional method using a high voltage divider, this developed method makes it possible to extend the range of output voltage from known low voltage measurement to high voltage measurement. From the linearity measured between electric field and applied voltage in the output voltage range of 1kV-30kV, the output voltage value up to 60kV can be obtained by the electric field measurement using the electric field sensor. The output voltage value obtained using the method is consistent with that obtained using high voltage divider within corresponding uncertainties.