• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.026 seconds

Evaluation of usefulness of multi directional angles oblique scan method in optic nerve MRI (시각신경 MR 검사 시 다중 각도 스캔 기법의 유용성 평가)

  • Cho, Moo-Seong;Cho, Jae-Hwan;Bae, Jae-Yeong;Kim, Jeong-Soo;Kim, Kyeong-Keun
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.4
    • /
    • pp.161-169
    • /
    • 2011
  • This research experimented on the change of the multiple colleague scan angle facing one scan object facet to many directions of the form of 3D about the visual angle nervous system forming the cubic distribution with the gradient magnetic field of the mri system and considered the existing basic angle oblique direction test coverage and comparison. MR system can freely select various pulse sequence and image slice. To oblique imaging for optic nerve viewing, we have studied the variation of scan angle between typical oblique scan method (sagittal-coronal plane) and multi directional angles oblique scan method (sagittal-coronal-axial plane) using gradient of MR system. In this study, the subjects of the experiment were normal adults in our country. As a result, we confirmed that multi directional angles oblique scan method can display anatomical information of more wider area than typical oblique scan method. In addition, to clearly display optic nerve, we also confirmed that image slice thickness and pulse sequence have effect on it.

The Design of Cardiovascular System Model Equipment for Education (심장 혈관계 시스템의 교육 모형 고안)

  • Won, Doyeon;Jung, Hongmoon;Jung, Jaeeun;Lee, Joonha
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.3
    • /
    • pp.117-121
    • /
    • 2014
  • The understanding of medical knowledge regarding cardiac shape and cardiovascular system is essentially required for a medical personnel as well as a medical technician. Correct acquisition of medical knowledge through cardiac miniature model is very critical because it is directly related to a patient life. therefore replica model is necessary for the education regarding cardiac and cardiovascular system. In this study anatomical cardiovascular system on fluoroscopy can be shown by cardiac and cardiovascular fluoroscopy replica model. Also, it helps to understand a cardiovascular radiograph. Consequentially medical personnel and medical technician are able to take advantage of this equipment to understand cardiovascular fluoroscopy system.

Evaluating the Reduction of Spatial Scattering based on Lead-free Radiation Shielding Sheet using MCNPX Simulation (MCNPX 시뮬레이션을 이용한 무납 방사선 차폐 시트 기반의 공간산란 저감화 평가)

  • Yang, Seung u;Park, Geum-byeol;Heo, Ye Ji;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.367-373
    • /
    • 2020
  • Most of the spatial scattered dose caused by the scattered rays generated by the collision between the object and X-rays is relatively easily absorbed by the human body as electromagnetic waves in the low energy region, thereby increasing the degree of radiation exposure. Such spatial scattering dose is also used as an indicator of the degree of radiation exposure of radiation workers and patients, and there is a need for a method to reduce exposure by reducing the spatial scattered dose that occurs indirectly. Therefore, in this study, a lead-free radiation shielding sheet was proposed as a way to reduce the spatial scattering dose, and a Monte Carlo (MC) simulation was performed based on a chest X-ray examination. The absorbed dose was calculated and the measured value and the shielding rate were compared and evaluated.

Analysis of Air Activation in PET Cyclotron Facility (PET 사이클로트론 시설의 공기 방사화 분석)

  • Jang, Dong-Gun;Kang, Sesik;Kim, Changsoo;Kim, Junghoon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.489-494
    • /
    • 2016
  • Nuclear reaction which occurs in the cyclotron generate unnecessary neutrons. The results of this happening can radioactivate surrounding materials and radioactive materials cause radiation exposure. When people take radioactive air, it makes internal exposure. The purpose of this study was to analyze the radioactive air inside of the ultra-compact 16.5 MeV cyclotron in operation. As a result of study, the radio activation occurred by compact cyclotron generates a very low internal exposure to workers. Comparing the radioactivity from radioactive nuclide with legal standard, that was under reference value. However, it could be at risk for internal exposure in case of higher energy cyclotron. Therefore, legal standard is needed for ventilation equipment of radiation facilities.

Polygonal Model Analysis on Occupational Exposure Record of Radiation Workers by Work Field (업종별 방사선작업종사자 피폭 기록 다각형 모델 분석 연구)

  • Je-Wan Park;Ji-Young Han;Yong-Min Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.277-284
    • /
    • 2023
  • Since the radiological risk is different depending on the working environment, protection measures and policies must be developed through analysis of the field area environment. Evaluating the characteristics of the field area that uses radiation should be conducted through comparative analysis with other industries, not just the numerical value of the field area. In this study, evaluation factors were derived from exposure records by the department to compare radiation occupational exposure records by sector. And then, we developed a polygonal model for comparative analysis and applied them to eight work fields through ten evaluation factors. Based on the occupational exposure record in 2020, a polygonal model was applied to compare and evaluate the characteristics of the radiation work area. Through this, the usefulness of the polygonal model was confirmed, and protection policy measures for the industry were proposed.

Recognition difference and improvement direction of the radiological technologists and patient against medical service in department radiology - In-chon area in the object - (방사선과 보건의료서비스에 대한 방사선사와 환자의 인식차이 및 개선방향 - 인천지역을 중심으로 -)

  • An, Sung-Min;Kim, Sung-Chul
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.93-98
    • /
    • 2006
  • Satisfaction of the patient against the medical service in department of radiology and it evaluated the different recognition of radiological technologist and patient. and investigates it's improvement direction. It sent the reply the above the which is a usual result in question result of the most that, the receipt process it was complicated in the portion which is insufficient,"The receipt process is complicated", "waiting time is long"and "don't radiation protection for patient and guardian". Also these a facts was recognizing patients and radiological technologist all. And the effort of the radiological technologist is necessary with the method which reduces a recognition difference. The periodical medical service satisfaction investigates and must endeavor in reform measure preparation.

  • PDF

Calibration of Optically Stimulated Luminescent nanoDot Dosimeter for 6 MV Photon Beam (6 MV 광자 빔에 대한 광자극형광나노닷선량계의 교정)

  • Kim, Jongeon;Kim, Seonghu;Lee, Hyoyeong
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.93-98
    • /
    • 2013
  • The purpose of this study is to investigate the calibration of an optically stimulated luminescent nanoDot dosimeter(OSLnD) to 6 MV photon beam. Dose ranges of the calibration of linear and non-linear from the analysis of dose response of the OSLnD were decided. To evaluate the accuracy of calibration equation and the calibration, the sets of the calibration and quality control dosimeter were used to make. The calibrations were performed by the linear and the non-linear in the dose range of 0~300 cGy and 20~1300 cGy, respectively. The errors of the calibration were acquired less than 0.1% respectively from the measurement of the quality control dosimeters for the calibration of linear and the non-linear. This study provides the calibration equation of the OSLnD to the 6 MV photon beam.

The effects of impacted premaxillary supernumerary teeth on permanent incisors

  • Jung, Yun-Hoa;Kim, Ji-Yeon;Cho, Bong-Hae
    • Imaging Science in Dentistry
    • /
    • v.46 no.4
    • /
    • pp.251-258
    • /
    • 2016
  • Purpose: The aim of this study was to examine the radiographic features associated with impacted premaxillary supernumerary teeth, to determine the relationship between their characteristics and their effects on permanent incisors, and to investigate the types of orthodontic treatment that patients received after the extraction of impacted supernumerary teeth. Materials and Methods: The clinical records and radiographs of 193 patients whose impacted premaxillary supernumerary teeth were removed were retrospectively reviewed, and 241 impacted supernumerary teeth were examined. Cone-beam computed tomographic images and panoramic radiographs were examined to determine the number, location, sagittal position, orientation, and morphology of the supernumerary teeth. Their effects on permanent incisors and the orthodontic treatment received by patients after the extraction of the supernumeraries were also investigated. Results: Supernumerary teeth were most frequently observed in the central incisor region, in the palatal position, in the inverted orientation, and were most commonly conical in shape. The most common complication was median diastema, followed by displacement and delayed eruption of the adjacent incisors. Ten (71.4%) of the 14 odontomas showed delayed eruption of the adjacent incisors. Displacement of the incisors was more frequently observed in association with supernumerary teeth with tuberculate or supplemental shapes. Orthodontic traction was most frequently performed after the removal of odontomas. In 32 cases (13.3%), permanent incisors erupted after the orthodontic creation of sufficient space. Conclusion: Median diastema was most common complication. The delayed eruption of incisors was common in supernumerary teeth with a vertical orientation and an odontoma shape.

Radioprotective effects of dimethyl sulfoxide in the artificial skin reconstructed with cultured human cells (배양된 사람 세포를 이용해 제작한 인공피부에서 방사선조사에 대한 dimethyl sulfoxide의 보호 효과)

  • Ryu Young-Ha;Choi Karp-Shik;Song In-Hwan
    • Imaging Science in Dentistry
    • /
    • v.32 no.1
    • /
    • pp.11-18
    • /
    • 2002
  • Purpose: To evaluate cultured human artificial skin as an experimental model for studying radiation effects in vitro. Materials and Methods: The skin was constructed by culturing keratinocytes over collagen lattice which made by culturing fibroblasts. Two groups were irradiated to gamma rays at single dose of 25 Gy with or without 3.5% of DMSO. Ultrastructures were investigated by electron microscopy after irradiation. The number of epidermal layers and expression of cytokeratin (CK) 14 & 10 were also seem by light microscopy. Results: At 2 days after irradiation in experimental group without DMSO, necrotic cells were rarely found in the spinosal layer and undercornified cells were visible in the homey layer. Similar findings were also found in experimental group with DMSO but in mild form. The number of epidermal layers in experimental group without DMSO were significantly fewer than other group. CK 14 expressed in all the layer excluding homey layer but CK 10 expressed over 3∼4 basal layers. Such patterns of CK expression were similar to all groups. It is suggested that structures of the keratinocytes and epidermal formation could be disturbed by irradiation in artificial skin and that DMSO can protect these damages. Conclusion : Therefore this work could be used as an organotypic experimental model in vitro using human cells for studying radiation effect in skin. Furthermore structural findings provided in this study could be used as useful basic data in further study using this model.

  • PDF

Comparison of high-resolution and standard zoom imaging modes in cone beam computed tomography for detection of longitudinal root fracture: An in vitro study

  • Taramsari, Mehran;Kajan, Zahra Dalili;Bashirzadeh, Parinaz;Salamat, Fatemeh
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.171-177
    • /
    • 2013
  • Purpose: The purpose of this study was to compare the efficacy of two imaging modes in a cone beam computed tomography (CBCT) system in detecting root fracture in endodontically-treated teeth with fiber posts or screw posts by selecting two fields of view. Materials and Methods: In this study, 78 endodontically-treated single canal premolars were included. A post space was created in all of them. Then the teeth were randomly set in one of 6 artificial dental arches. In 39 of the 78 teeth set in the 6 dental arches, a root fracture was intentionally created. Next, a fiber post and a screw post were cemented into 26 teeth having equal the root fractures. High resolution (HiRes) and standard zoom images were provided by a CBCT device. Upon considering the reconstructed images, two observers in agreement with each other confirmed the presence or absence of root fracture. A McNemar test was used for comparing the results of the two modes. Results: The frequency of making a correct diagnosis using the HiRes zoom imaging mode was 71.8% and in standard zoom was 59%. The overall sensitivity and specificity in diagnosing root fracture in the HiRes mode were 71.79% and 46.15% and in the standard zoom modes were 58.97% and 33.33%, respectively. Conclusion: There were no significant differences between the diagnostic values of the two imaging modes used in the diagnosis of root fracture or in the presence of root canal restorations. In both modes, the most true-positive results were reported in the post space group.