• Title/Summary/Keyword: Radiological Effects

Search Result 597, Processing Time 0.021 seconds

Effects of Music Therapy on Anxiety of Intravenous Urology Patients (음악요법이 경정맥요로조영 검사시 환자의 불안에미치는 영향)

  • Yeo, Jin-Dong;Ko, In-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.95-107
    • /
    • 2017
  • This study is a research based on the non-equivalent control group pretest-posttest design whose purpose is to examine the effects of music therapy on the anxiety of patients who take the Intravenous Urography test and their feeling of discomfort during the test. "The first hypothesis that the experimental group who receive music therapy will be lower in score for anxiety during the Intravenous UrographyI test than the control group who do not was supported because after the therapy, the experimental group was found significantly decreased in that score in comparison to the control group. "The second hypothesis that the experimental group who receive music therapy will be fewer in vital signs after the Intravenous Urography test than the control group who do not" was rejected in terms of both systolic and diastolic blood pressure. But the same hypothesis was partially supported because the two groups showed a significant difference in pulse rate after the test. "The third hypothesis that the experimental group who receive music therapy will be less in the feeling of subjective discomfort during the Intravenous Urography test than the control group who do not" was verified to find that the two groups were significantly different from each other in the feeling. Specifically, there was a significant difference between the two groups in only one sub-area of that These findings suggest that music therapy could be an alternative method which can effectively reduce the state anxiety of patients during the Intravenous Urography test.

Effects of Practical Training Using 3D Printed Structure-Based Blind Boxes on Multi-Dimensional Radiographic Image Interpretation Ability (3D 프린팅 구조물 기반 블라인드박스를 이용한 실습교육이 다차원 방사선영상해독력에 미치는 효과)

  • Youl-Hun, Seoung
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.131-139
    • /
    • 2023
  • In this study, we are purposed to find the educational effect of practical training using a 3D printed structure-based blind box on multidimensional radiographic image interpretation. The subjects were 83 (male: 49, female: 34) 2nd year radiological science students who participated in the digital medical imaging practice that was conducted for 3 years from 2020 to 2022. The learning method used 3D printing technology to print out the inside structure of the blind box designed by itself. After taking X-rays 3 times (x, y, z axis), the structure images in the blind box were analyzed for each small group. We made the 3D structure that was self-made with clay based on our 2D radiographic images. After taking X-rays of the 3D structure, it was compared whether it matches the structural image of the blind box. The educational effect for the practical training surveyed class faithfulness, radiographic image interpretation ability (attenuation concept, contrast concept, windowing concept, 3-dimensional reading ability), class satisfaction (interest, external recommendation, immersion) on a 5-point Likert scale as an anonymous student self-writing method. As a result, all evaluation items had high positive effects without significant differences between males and females. Practical education using blind boxes is a meaningful example of radiology education technology using 3D printing technology, and it is expected to be used as content to improve students' problem-solving skills and increase satisfaction with major subjects.

Radiation Protection Effects of Dendranthema Zawadskii Var. Latilobum (Maxim.) Kitam. Extracts on Blood Cells, Intestine, and Uterus of Female SD Rats Irradiated with Gamma-Ray 10 Gy (구절초 추출물이 감마선 10 Gy에 조사된 암컷 SD Rat의 혈구 및 소장, 자궁에 미치는 방사선 방호효과)

  • Sung-Hyun, Joo;Hae-Suk, Kim;Sang-Hyun, Jeong;Jae-Gyeong, Choi;Seong-Ok, Jin;Byung-In, Min
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.23-28
    • /
    • 2023
  • The purpose of this study is to see the radiation protection effect of the oral injected Dendranthema zawadskii var. latilobum (Maxim.) Kitam. extracts on the small intestine and uterus of female SD Rat as a natural radiation protection agent. The experimental group was divided into four groups: Normal Control group (NC group), Injected Dendranthema zawadskii var. latilobum (Maxim.) Kitam. extracts group (DZ group), irradiated group after injecting Dendranthema zawadskii var. latilobum (Maxim.) Kitam. extracts (DZ+IR group). The whole body of SD Rat was irradiated with gamma-ray 10Gy, and the administration of oral Dendranthema zawadskii var. latilobum (Maxim.) Kitam. Extract was 2 cc (71.56 mg/day/kg) once a day for 2 weeks. For this study, chages in blood cell levels, SOD assay, small intestine and uterus were observed. In the 21st white blood cell level, the DZ+IR group recovered to a normal level, and the IR group didn't. The IR group villus length was lower than other groups on Day 1. IR group was partially recovered, and DZ+IR group was recovered like the NC group on Day 21. In the case of the first-day endometrium, the IR group was thin and the boundary was cloudy, and the DZ+IR group was thicker and the boundary was clearer than the IR group. Day 21 IR group still did not recover, and DZ+IR group recovered like NC group. This is believed to have radiation protection effects in the blood cells and small intestine and uterus of the irradiated female SD Rat, and is expected to be useful for the study of natural radiation protection materials.

Developments of Space Radiation Dosimeter using Commercial Si Radiation Sensor (범용 실리콘 방사선 센서를 이용한 우주방사선 선량계 개발)

  • Jong-kyu Cheon;Sunghwan Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.367-373
    • /
    • 2023
  • Aircrews and passengers are exposed to radiation from cosmic rays and secondary scattered rays generated by reactions with air or aircraft. For aircrews, radiation safety management is based on the exposure dose calculated using a space-weather environment simulation. However, the exposure dose varies depending on solar activity, altitude, flight path, etc., so measuring by route is more suggestive than the calculation. In this study, we developed an instrument to measure the cosmic radiation dose using a general-purpose Si sensor and a multichannel analyzer. The dose calculation applied the algorithm of CRaTER (Cosmic Ray Telescope for the Effects of Radiation), a space radiation measuring device of NASA. Energy and dose calibration was performed with Cs-137 662 keV gamma rays at a standard calibration facility, and good dose rate dependence was confirmed in the experimental range. Using the instrument, the dose was directly measured on the international line between Dubai and Incheon in May 2023, and it was similar to the result calculated by KREAM (Korean Radiation Exposure Assessment Model for Aviation Route Dose) within 12%. It was confirmed that the dose increased as the altitude and latitude increased, consistent with the calculation results by KREAM. Some limitations require more verification experiments. However, we confirmed it has sufficient utilization potential as a cost-effective measuring instrument for monitoring exposure dose inside or on personal aircraft.

Radiation effects to acupuncture in mice embryos

  • Tano Kaori;Itokawa Yuka;Maenaka Toshihiro;Sakazaki Takahiko;Yamashita Takenori;Nakamura Takashi;Cho Kwang-Ho;Choi Jung-Sook;Ahn Kyoo-Seok;Ishida Torao;Gu Yeun-Hwa
    • Advances in Traditional Medicine
    • /
    • v.6 no.3
    • /
    • pp.245-251
    • /
    • 2006
  • We examined the radioprotection effects of acupoint (acupuncture point) stimulation during organogenesis stages of ICR mice. Pregnant mice received 1.5 Gy whole body X-irradiation on day 8 of gestation, which is the early stage of organogenesis. The embryonic death rate and teratogenesis rate by radiation were examined. Electroacupuncture to the leg acupoints and/ or transcutaneous stimulation to the back acupoints on the pregnant mice showed no protective effect against irradiation on embryonic or fetal death rate. On the contrary, the strong stimulation resulted in increase in the mortality after irradiation rather than protection. However acupoint stimulation to the pregnant mice never showed harmful effects by itself on embryos. It tended to reduce the skeletal malformations induced by X-ray irradiation. We suspect that acupoint stimulation removed the cells injured by irradiation during embryonic development, resulting in an increase in embryonic death rate and reduction in skeletal anomalies.

Anti-Diabetic Effects of Mori Folium Extract on High-Fat Diet and Streptozotocin-Induced Type II Diabetes Mellitus in Mice (고지방식이와 STZ 유도 제2형 당뇨병 마우스에서 상엽 추출물의 항당뇨 효과)

  • Kwon, Tae-Oh;Choi, Ji-Won;Lee, Hyun-Seo;Cho, Byoung-Ok;Yin, Hong-Hua;Jang, Seon-Il
    • The Korea Journal of Herbology
    • /
    • v.30 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • Objectives : The present study was designed to investigate the anti-diabetic effects of Mori Folium (Morus alba L. of Moraceae) extract (MFE) on high fat diet (HFD) and streptozotocin (STZ)-induced type II diabetes mellitus in mice. Methods : The mice (C57BL/6J) were fed HFD for 8 weeks and then was induced with a single injection of STZ (75 mg/kg). The diabetic mice were divided into four groups [(STD, HFD, HFD + MFE and HFD + quercetin (QUR)] and administered with MFE or OUR for 4 weeks. Fasting blood glucose, lipid profile (triglycerides and cholesterol etc.), glutamic oxaloacetic transaminase (GOT), glutamic pyruvic transaminase (GPT), insulin and leptin were measured every 2 weeks. Results : Body weight gain was lower in the MFE and QUR groups than HFD group. The fasting blood glucose was lower in the MFE and QUR groups. Oral glucose and insulin tolerance were decreased in the MFE and QUR groups. The levels of serum total cholesterol, triglycerides, and LDL cholesterol were reduced in the MFE and QUR groups. The HDL cholesterol was much higher in the MFE and QUR groups than HFD group. The levels of GOT, GPT and atherogenic index were decreased in the MFE and QUR groups. The serum insulin and leptin concentrations were reduced in the MFE and QUR groups. Conclusions : These results showed that MFE could decrease blood glucose level and lead to an amelioration in dyslipidemia states on HFD/STZ-induced type II diabetes mellitus in mice.

The Effect of Continuous Ultrasound Therapy and Pulsed Ultrasound Therapy on Adjuvant Induced Rheumatoid Arthritis in Rat (지속적인 초음파치료와 맥동 초음파치료가 Adjuvant로 유도된 흰쥐의 관절염에 미치는 효과)

  • Lee, Byeung-Ok;Min, Kyung-Ok;Hong, Wan-Seng;Lee, Kyung-Moo;Hwang, Seock-Yeon
    • Journal of Korean Physical Therapy Science
    • /
    • v.9 no.4
    • /
    • pp.7-14
    • /
    • 2002
  • The drug therapy for rheumatoid arthritis must be maintained constantly or for the whole life but is apt to induce the adverse effects in gastrointestinal or renal system. Therefor, newer methods are paid attention to reduce adverse effects. The thirty-two rat female separated into seven groups depending on the therapy or Freund's adjuvant applied: Normal group(n=8) not received anything, Positive control group(n=8) only received adjuvant, USC group(n=8) received continuous US, USP group(n=8) received pulsed US. The physical and radiological findings by thermal and non-thermal effects of ultrasound were evaluated in groups with continuous mode at 1 MHz, $0.5\;W/cm^2$ for 6 minutes and with pulsed mode (duty cycle 1:9) at 1 MHz, $0.5\;W/cm^2$ for 6 minutes. The result summarized followings. 1. Swelling of forepaw and hindpaw was significantly reduced in USP. 2. Arthritis indices in USP group were significantly reduced than those in PCG. 3. In naked eye and radiologic findings, swelling was significantly prevented in USP group but not in PCG. The change of swelling, arthritis index, gross feature in naked eye, radiologic finding were significantly improved in all groups except for USC group, taking care for using its continuous mode.

  • PDF

The Apoptosis according to the Processing Irradiation and The Tumor Necrosis Factor (종양괴사인자와 방사선이 세포자멸사에 미치는 영향)

  • Lee, Jaeseob;Jang, Seongjoo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.195-200
    • /
    • 2016
  • Acute promyelocytic leukemia(APL) is not just the poor grades of treating a type of blood cancer hayeoteul combination with chemotherapy despite concurrent radiation therapy are known to exhibit a greater effect and also works on normal cells to result in side effects. In this study, when after treatment with gamma rays, such as $TNF-{\alpha}$ in order to reduce these side effects was confirmed how affected the cell death of normal cells and cancer cells. HL-60 cells were used as the APL cell line HL-60 cells were differentiated with DMSO for treatment are shown the properties of normal granulocytes was used as a control group. As a result, HL-60 cells treated with $TNF-{\alpha}$ and gamma rays with only showed a cytotoxic effect by inducing the apoptosis cells were put to death. Consequently, $TNF-{\alpha}$ is thought to active substances that can increase the efficiency of cancer treatment to increase the removal of cancer cells when used with low-density gamma-ray treatment in order to eliminate the side effects of chemotherapy.

Contrast Media Side Effects Prediction Study using Artificial Intelligence Technique (인공지능 기법을 이용한 조영제 부작용 예측 연구)

  • Sang-Hyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.423-431
    • /
    • 2023
  • The purpose of this study is to analyze the factors affecting the classification of the severity of contrast media side effects based on the patient's body information using artificial intelligence techniques to be used as basic data to reduce the degree of contrast medium side effects. The data used in this study were 606 examiners who had no contrast medium side effects in the past history survey among 1,235 cases of contrast medium side effects among 58,000 CT scans performed at a general hospital in Seoul. The total data is 606, of which 70% was used as a training set and the remaining 30% was used as a test set for validation. Age, BMI(Body Mass Index), GFR(Glomerular Filtration Rate), BUN(Blood Urea Nitrogen), GGT(Gamma Glutamyl Transgerase), AST(Aspartate Amino Transferase,), and ALT(Alanine Amiono Transferase) features were used as independent variables, and contrast media severity was used as a target variable. AUC(Area under curve), CA(Classification Accuracy), F1, Precision, and Recall were identified through AdaBoost, Tree, Neural network, SVM, and Random foest algorithm. AdaBoost and Random Forest show the highest evaluation index in the classification prediction algorithm. The largest factors in the predictions of all models were GFR, BMI, and GGT. It was found that the difference in the amount of contrast media injected according to renal filtration function and obesity, and the presence or absence of metabolic syndrome affected the severity of contrast medium side effects.

Effects of Contrast Improvement on High Voltage Rectification Type of X-ray Diagnostic Apparatus (X선 진단장치의 고압정류방식이 대조도 향상에 미치는 영향)

  • Lee, Hoo-Min;Yoon, Joon;Kim, Hyun-Ju
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.187-193
    • /
    • 2014
  • The purpose of this study was to analyze the effect on the selectivity on of high-voltage rectification device that measured the performance of the grid, and the contrast improvement ability (K factor) by measuring the scattered radiation content of the transmitted X-rays. The scattered radiation generated when the X-ray flux comes from the diagnostic X-ray generator that passes through an object. Targeting four different rectifications of X-ray generators, the mean value of the tube voltage and the tube current was measured in order to maximize the accuracy of the generating power dose within the same exposure condition. Using fluorescence meter, the content of the scattered rays that are transmitted through the acrylic was measured depending on the grid usage. When grid is not used, the content of the scattered rays was the lowest (34.158%) with the single-phase rectifier, was increased with the inverter rectifier (37.043%) and the three-phase 24-peak rectification method (37.447%). The difference of the scattered radiation content of each device was significant from the lowest 0.404% to the highest 3.289% while using 8:1 grid, the content of the scattered ray was the lowest with the single content of the scattered ray was the lowest with the single-phase rectifier (18.258%), was increased with the rectifier (25.502%) and the 24-peaks rectification (24.217%). Furthermore, there was difference up to content 7.244% to the lowest content 1.285% within three-phase 24-peaks rectification, inverter rectifications, and single-phase rectifier depending on the selectivity of the grid. Drawn from the statistical analysis, there was a similar relationship between the contrast improvement factor and the K factor. As a result, the grid selectivity and the contrast were increased within the single-phase rectifier rather than the constant voltage rectifier.