• Title/Summary/Keyword: Radiography, Thoracic

Search Result 181, Processing Time 0.03 seconds

A Case of Congenital Cystic Adenomatoid Malformation Infected with Mycobacterium avium-intracellulare Complex

  • Kim, Yong Jin;Kim, Do Young;Seo, Jung Woong;Lee, Song Am;Hwang, Jae Joon;Kim, Hee Joung;Lee, Kye Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.74 no.1
    • /
    • pp.28-31
    • /
    • 2013
  • We present a case of congenital cystic adenomatoid malformation (CCAM) in a 25-year-old male who was presented with chronic cough. Chest radiography revealed an abnormal mass-like shadow in the right lower pulmonary zone. A contrast enhanced computed tomography showed an 11 cm solid, cystic mixed mass on the right lower lobe. A right lower lobectomy was performed by video-assisted thoracoscopic surgery without complications. The gross specimen showed a massive cavitation with multiloculated cysts of varying size, consistent with CCAM, along with noticeable granulomatous inflammation. Non-tuberculosis mycobacteria were isolated from a bronchial wash specimen, and the resected tissue homogenates were positive for Mycobacterium avium-intracellulare complex by polymerase chain reaction.

Surgical Removal of Intrathoracic Lipoma from Herniated Omentum through the Diaphragmatic Defect in an Abyssinian Cat

  • Lee, Jiyeon;Park, Hyojin;Kim, Jieyoo;Kim, Na-Hyun;Lee, Dongbin;Lee, Hee-Chun;Hwang, Tae-Sung;Lee, Jae-Hoon
    • Journal of Veterinary Clinics
    • /
    • v.38 no.4
    • /
    • pp.174-178
    • /
    • 2021
  • A nine-year-old neutered male cat was presented with chronic cough and vomiting. Thoracic radiography showed regions of fatty opacity in the right caudoventral region. On positive contrast celiography, contrast agent did not move into thoracic cavity. Computed tomography revealed 7-mm diameter of defect at the right diaphragmatic crus and a 2-mm diameter defect at the left ventral diaphragmatic crus. Through the right diaphragmatic defect omental herniation was confirmed by the presence of contrast enhanced omental vessel running across the diaphragm. On exploratory thoracotomy, the omentum protruded into the thorax through the right diaphragmatic defect, and it contained a yellowish lipomatous mass. The protruded omentum containing a mass in the thorax was removed, and the right diaphragmatic defect was closed. Histopathologic examination revealed that the protruded omentum showed normal omental structure and the adipose mass showed lipoma surrounded by fibrous tissue. In conclusion, a thorough examination is necessary to confirm the origin of the mass located near the diaphragm.

Transient Myocardial Thickening in a 4-year-old Korean Domestic Shorthair Cat

  • Yunhee Joung;Hyerin Ahn;Jeongbae Choi;YoungMin Yun;Woo-Jin Song
    • Journal of Veterinary Clinics
    • /
    • v.41 no.2
    • /
    • pp.106-111
    • /
    • 2024
  • A 4-year-old neutered female domestic shorthair cat weighing 5.1 kg was referred to Jeju National University Hospital with acute onset respiratory distress, weakness, and anorexia. The patient had a history of stressful antecedent events that involved bullying by a newly introduced cat. Thoracic radiography and echocardiography revealed a stage C hypertrophic cardiomyopathy phenotype based on the American College of Veterinary Internal Medicine classification system with pulmonary edema, pleural effusion, and pericardial effusion at the same time. The patient was treated with furosemide, pimobendan, and rivaroxaban. Pericardiocentesis was performed because pericardial effusion was identified. Reevaluation after 30 days revealed a normal respiratory rate on physical examination, normal cardiac shape on thoracic radiographs, and normal cardiac measurements on echocardiography. The patient was tentatively diagnosed with transient myocardial thickening (TMT) and all medications were discontinued. Six months after the initial hospitalization, the cat continued to do well without any clinical signs or left ventricular wall thickening. This case is the first report describing feline TMT in Korea. Moreover, it involves a rare case in which pulmonary edema, pleural effusion, and pericardial effusion, which induce cardiac tamponade, occurred simultaneously due to TMT-related congestive heart failure.

Evaluation of Approximate Exposure to Low-dose Ionizing Radiation from Medical Images using a Computed Radiography (CR) System (전산화 방사선촬영(CR) 시스템을 이용한 근사적 의료 피폭 선량 평가)

  • Yu, Minsun;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.455-464
    • /
    • 2012
  • This study suggested evaluation of approximately exposure to low-dose ionization radiation from medical images using a computed radiography (CR) system in standard X-ray examination and experimental model can compare diagnostic reference level (DRL) will suggest on optimization condition of guard about medical radiation of low dose space. Entrance surface dose (ESD) cross-measuring by standard dosimeter and optically stimulated luminescence dosimeters (OSLDs) in experiment condition about tube voltage and current of X-ray generator. Also, Hounsfield unit (HU) scale measured about each experiment condition in CR system and after character relationship table and graph tabulate about ESD and HU scale, approximately radiation dose about head, neck, thoracic, abdomen, and pelvis draw a measurement. In result measuring head, neck, thoracic, abdomen, and pelvis, average of ESD is 2.10, 2.01, 1.13, 2.97, and 1.95 mGy, respectively. HU scale is $3,276{\pm}3.72$, $3,217{\pm}2.93$, $2,768{\pm}3.13$, $3,782{\pm}5.19$, and $2,318{\pm}4.64$, respectively, in CR image. At this moment, using characteristic relationship table and graph, ESD measured approximately 2.16, 2.06, 1.19, 3.05, and 2.07 mGy, respectively. Average error of measuring value and ESD measured approximately smaller than 3%, this have credibility cover all the bases radiology area of measurement 5%. In its final analysis, this study suggest new experimental model approximately can assess radiation dose of patient in standard X-ray examination and can apply to CR examination, digital radiography and even film-cassette system.

The Evaluation of CR and DDR chest image using ROC analysis (ROC평가 방법을 이용한 CR과 DDR 흉부 영상의 비교)

  • Park, Yeon-Ok;Jung, Eun-Kyung;Park, Yeon-Jung;Nam, So-Ra;Jung, Ji-Young;Kim, Hee-Joung
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.1
    • /
    • pp.25-30
    • /
    • 2007
  • ROC(Receiver Operating Characteristic)curve is the method that estimate detected insignificant signal from the human's sense of sight, it has been raised excellent results. In this study, we evaluate image quality and equipment character by obtaining a chest image from CR(Computed Radiography) and DDR(Direct Digital radiography) using the human chest phantom, The parameter of exposure for obtaining chest image was 120 kVp/3.2 mAs and the SID(Source to Image Distance) was 180cm. The images were obtained by CR(AGFA MD 4.0 General plate, JAPAN) and DDR(HOLOGIC nDirect Ray, USA). Using some pieces of Aluminum and stone for expressing regions, then attached them on the heart, lung and thoracic vertebrae of the phantom. 29 persons hold radiology degrees were participated in ROC analysis. As a result of the ROC analysis, TPF(true positive fraction) and FPF(false positive fraction) of DDR and CR are 0.552 and 0.474 and 0.629 and 0.405, respectively. By using the results, the ROC curve of CR has higher image quality than DDR. According to the theory, DDR has the higher image quality than CR in chest X-ray image. But, CR has the higher image quality than DDR. quality of DDR inserted the enhance board. The results confirmed that image post-processing is important element decipherment of clinical.

  • PDF

A late onset solitary mediastinal cystic lymphangioma in a 66-year-old woman who underwent kidney transplantation

  • Lee, Jung Mo;Lee, Sang Hoon;Park, Youngmok;Kim, Chi Young;Goag, Eun Kyoung;Lee, Eun Hye;Park, Ji Eun;Lee, Chang Young;Kim, Se Kyu
    • Journal of Yeungnam Medical Science
    • /
    • v.32 no.2
    • /
    • pp.155-158
    • /
    • 2015
  • Lymphangioma is a congenital abnormality of the lymphatic system detected primarily in early childhood. There are rare reports of mediastinal lymphangioma in older adults. We hereby report on a 66-year-old female patient who underwent kidney transplantation 20 years previously and who developed pathologically confirmed solitary mediastinal lymphangioma 1 year ago. Chest radiography showed a mediastinal nodule, which was not observed 2 year previously, therefore she was referred to the pulmonary division. She had no symptoms, and chest computed tomography demonstrated a 25-mm, well-defined, low-density nodule located at the anterior mediastinum. The size of the nodule had increased from 25 mm to 34 mm 1 year later, and it was completely resected via video-assisted thoracic surgery. The histological diagnosis was cystic lymphangioma. Therefore, we recommend that clinicians consider cystic lymphangioma as a possible diagnosis even in older patients with a mediastinal cystic mass that shows progressive enlargement.

Use of Imaging Agent to Determine Postoperative Indwelling Epidural Catheter Position

  • Uchino, Tetsuya;Hagiwara, Satoshi;Iwasaka, Hideo;Kudo, Kyosuke;Takatani, Junji;Mizutani, Akio;Miura, Masahiro;Noguchi, Takayuki
    • The Korean Journal of Pain
    • /
    • v.23 no.4
    • /
    • pp.247-253
    • /
    • 2010
  • Background: Epidural anesthesia is widely used to provide pain relief, whether for surgical anesthesia, postoperative analgesia, treatment of chronic pain, or to facilitate painless childbirth. In many cases, however, the epidural catheter is inserted blindly and the indwelling catheter position is almost always uncertain. Methods: In this study, the loss-of-resistance technique was used and an imaging agent was injected through the indwelling epidural anesthesia catheter to confirm the position of its tip and examine the migration rate. Study subjects were patients scheduled to undergo surgery using general anesthesia combined with epidural anesthesia. Placement of the epidural catheter was confirmed postoperatively by injection of an imaging agent and X-ray imaging. Results: The indwelling epidural catheter was placed between upper thoracic vertebrae (n = 83; incorrect placement, n = 5), lower thoracic vertebrae (n = 123; incorrect placement, n = 5), and lower thoracic vertebra-lumbar vertebra (n = 46; incorrect placement, n = 7). In this study, a relatively high frequency of incorrectly placed epidural catheters using the loss-of-resistance technique was observed, and it was found that incorrect catheter placement resulted in inadequate analgesia during surgery. Conclusions: Although the loss-of-resistance technique is easy and convenient as a method for epidural catheter placement, it frequently results in inadequate placement of epidural catheters. Care should be taken when performing this procedure.

Modified Extraluminal Prostheses Applied to the Canine Tracheal Collapse (변형제작한 기관외보철물을 이용한 기관허탈전 치료 1예)

  • 이충호;권오경;남치주
    • Journal of Veterinary Clinics
    • /
    • v.17 no.1
    • /
    • pp.266-269
    • /
    • 2000
  • Tracheal collapse at the thoracic inlet is described in a 4 year-old female yorkshire terrier. The initial presenting signs included coughing, dyspnea, cyanosis and collapse. Diagnosis was based upon the clinical signs, physical examination, plain radiography and fluoroscopy. The collapse was corrected by the aplication of a neumber of modified total ring prostheses (m-TRP) applied to the cervical trachea. Clinical complicatons were minimal and limited to mild, short-term coughing. The present study indicated that m-TRP were easy to apply to tracheal collapse and were able to decrese clinical signs. Therefore, m-TRP may be applied to tracheal collapse as new prostheses.

  • PDF

Partial Atrioventricular Canal Defect in a Maltese Dog

  • Lee, Seung-Gon;Nam, So-Jeong;Moon, Hyeong-Sun;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.25 no.3
    • /
    • pp.195-199
    • /
    • 2008
  • A 2-year-old female Maltese dog was referred with primary complaints of exercise intolerance and abnormal heart sound. Clinical and diagnostic investigation revealed split S2 and S4 gallop in the cardiac auscultation, tall P wave and left anterior fascicular block in the electrocardiogram, left atrial enlargement on the thoracic radiography, ostium primum atrial septal defect and cleft of the anterior leaflet of the mitral valve on the echocardiography. Based on those findings, the dog was diagnosed as the partial atrioventricular canal defect. Since the dog showed mild exercise intolerance, enalapril and furosemide were prescribed.

Tricuspid valve dysplasia complicated with pulmonic regurgitation in a Cocker Spaniel dog

  • Nam, So-Jeong;Choi, Ran;Park, In-Chul;Hyun, Changbaig
    • Korean Journal of Veterinary Research
    • /
    • v.48 no.4
    • /
    • pp.481-487
    • /
    • 2008
  • A 17-month-old intact male Cocker Spaniel was presented with primary complaints of severe ascites, exercise intolerance, and diarrhea. Diagnostic studies revealed tricuspid and pulmonic regurgitation on phonocardiogram, right ventricular enlargement on the electrocardiogram, typical right cardiac enlargement signs on the thoracic radiography and tricuspid valve malformation and marked enlargement of the right atrium and right ventricle on the echocardiography and tricuspid and pulmonary regurgitation on the color spectral echocardiography, suggesting tricuspid valve dysplasia and pulmonary hypertension. Using angiography and cardiac catheterization, pulmonary hypertension was ruled out. Further echocardiographic study revealed membranous valvular structures cranial to pulmonary annulus causing pulmonary regurgitation. Based on these findings on the diagnostic investigation, the case was diagnosed as tricuspid valve dysplasia complicated with pulmonic regurgitation. The dog was medically managed with furosemide, enalapril, nitroglycerine transdermal patch and pimobendan after the ascitic fluid removal.