• Title/Summary/Keyword: Radio frequency (RF)

Search Result 1,042, Processing Time 0.025 seconds

T1-Based MR Temperature Monitoring with RF Field Change Correction at 7.0T

  • Kim, Jong-Min;Lee, Chulhyun;Hong, Seong-Dae;Kim, Jeong-Hee;Sun, Kyung;Oh, Chang-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.4
    • /
    • pp.218-228
    • /
    • 2018
  • Purpose: The objective of this study is to determine the effect of physical changes on MR temperature imaging at 7.0T and to examine proton-resonance-frequency related changes of MR phase images and T1 related changes of MR magnitude images, which are obtained for MR thermometry at various magnetic field strengths. Materials and Methods: An MR-compatible capacitive-coupled radio-frequency hyperthermia system was implemented for heating a phantom and swine muscle tissue, which can be used for both 7.0T and 3.0T MRI. To determine the effect of flip angle correction on T1-based MR thermometry, proton resonance frequency, apparent T1, actual flip angle, and T1 images were obtained. For this purpose, three types of imaging sequences are used, namely, T1-weighted fast field echo with variable flip angle method, dual repetition time method, and variable flip angle method with radio-frequency field nonuniformity correction. Results: Signal-to-noise ratio of the proton resonance frequency shift-based temperature images obtained at 7.0T was five-fold higher than that at 3.0T. The T1 value increases with increasing temperature at both 3.0T and 7.0T. However, temperature measurement using apparent T1-based MR thermometry results in bias and error because B1 varies with temperature. After correcting for the effect of B1 changes, our experimental results confirmed that the calculated T1 increases with increasing temperature both at 3.0T and 7.0T. Conclusion: This study suggests that the temperature-induced flip angle variations need to be considered for accurate temperature measurements in T1-based MR thermometry.

Capacitively Coupled Radio Frequency Discharge System for Excitation of Gas Laser (기체레이저의 여기를 위한 용량결합고주파(ccrf) 방전시스템)

  • Choi, Sang-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.19-26
    • /
    • 2006
  • The ccrf-discharge has in comparison with the hollow-cathode discharge and DC-discharge some advantages: Simple design of the tube and homogeneous plasma. The ccrf-discharge was researched with the goal, to use on the excitation of the gas laser. In this work a rf-exciting system was planned and developed. With it a homogeneous discharge was produced in the cw operation. To supply the rf-power with the frequency 13.56[MHz] effectively in the discharge, laser tube were used with inner diameter of 5[mm] and the specially developed rf-electrodes. A matching circuit was composed also. Thereby the impedance of the discharge tube was adjusted to the 50[$\Omega$] output resistance of the rf-source.

Volumetric Blood Velocity Measurement on Multigate Pulsed Doppler System based on the Single Channel RF Sampling using the Optimized Sampling Factor (최적화된 샘플링 인수를 갖는 단일 채널 RF 샘플링 방식의 다중점 펄스 도플러 시스템을 사용한 혈류 속도분포 측정)

  • 임춘성;민경선
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.143-152
    • /
    • 1998
  • In this paper, we present the performances of a Doppler system using single channel RF(Radio Frequency) sampling. This technique consists of undersampling the ultrasonic blood backscattered RF signal on a single channel. Conventional undersampling method in Doppler imaging system have to use a minimum of two identical parallel demodulation channels to reconstruct the multigate analytic Doppler signal. However, this system suffers from hardware complexity and problem of unbalance(gain and phase) between the channels. In order to reduce these problems, we have realized a multigate pulsed Doppler system using undersampling on a single channel, It requires sampling frequency at $4f_o$(where $f_o$ is the center frequency of the transducer) and 12bits A/D converter. The proposed " single-Channel RF Sampling" method aims to decrease the required sampling frequency proportionally to $4f_o$/(2k+1). To show the influence of the factor k on the measurements, we have compared the velocity profiles obtained in vitro and in vivo for different intersequence delays time (k=0 to 10). We have used a 4MHz center frequency transducer and a Phantom Doppler system with a laminar stationary flow. The axial and volumetric velocity profiles in the vessel have been computed according to factor k and have been compared. The influence of the angle between the ultrasonic beam and the flow axis direction, and the fluid viscosity on the velocity profiles obtained for different values of k factor is presented. For experiment in vivo on the carotid, we have used a data acquisition system with a sampling frequency of 20MHz and a dynamic range of 12bits. We have compared the axial velocity profiles in systole and diastole phase obtained for single channel RF sampling factor.ng factor.

  • PDF

Integrated Photonic RF Phase Shifter Using an Electrooptic Polymer Modulator (전기광학폴리머 변조기틀 이용한 집적광학적 RF 위상변환기)

  • 이상신
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.3
    • /
    • pp.274-277
    • /
    • 2004
  • An integrated photonic radio frequency (RF) phase shifter has been proposed and fabricated using a nested dual Mach-Zehnder modulator configuration in a new electro-optic polymer. The fabricated device shows a continuous voltage control of the RF signal phase. A near-linear phase shift exceeding 108$^{\circ}$was obtained for a 16-GHz microwave signal by tuning the do control voltage over a 7.8- $V_{pp}$ range.e.

Reliability Evaluation of RF Power Amplifier for Wireless Transmitter

  • Choi, Jin-Ho
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.2
    • /
    • pp.154-157
    • /
    • 2008
  • A class-E RF(Radio Frequency) power amplifier for wireless application is designed using standard CMOS technology. To drive the class-E power amplifier, a class-F RF power amplifier is used and the reliability characteristics are studied with a class-E load network. The reliability characteristic is improved when a finite-DC feed inductor is used instead of an RF choke with the load. After one year of operating, when the load is an RF choke the output current and voltage of the power amplifier decrease about 17% compared to initial values. But when the load is a finite DC-feed inductor the output current and voltage decrease 9.7%. The S-parameter such as input reflection coefficient(S11) and the forward transmission scattering parameter(S21) is simulated with the stress time. In a finite DC-feed inductor the characteristics of S-parameter are changed slightly compared to an RF-choke inductor. From the simulation results, the class-E power amplifier with a finite DC-feed inductor shows superior reliability characteristics compared to power amplifier using an RF choke.

Low-Cost High-Performance TDD Synchronizer for WiBro RF Repeater

  • Seo, Young-Ho;Kim, Dong-Wook
    • ETRI Journal
    • /
    • v.32 no.4
    • /
    • pp.503-511
    • /
    • 2010
  • WiBro radio frequency (RF) repeater is used for solving the problem of partial shadow areas in the wireless communication field that uses time-division duplexing (TDD) mode. In this paper, a method to efficiently generate TDD signals for WiBro RF repeater is proposed and its digital circuit is implemented. A TDD signal is detected from RF signals transmitted/received to/from RF repeater and then inputted again into the RF repeater, so that it can operate normally. First, the envelope of downlink signals is detected and then clamped to extract the basic form of a TDD signal using an operational amplifier circuit. Next, the TDD signal is generated by restoring and filtering the shape which has been distorted by the wireless channel. The algorithm and system to acquire TDD signal are developed with a goal to have simple but powerful functions with as little cost as possible. The proposed method is implemented as an RF-digital integrated system and verified through the experiments under the same condition as actual WiBro service environment.

Synthesis of transparent diamond-like carbon film on the glass by radio-frequency plasma enhanced chemical vapor deposition (RF-PECVD법에 의한 투명 다이아몬드상 탄소 박막 합성)

  • Kim, Tae-Gyu;Shin, Yeong-Ho;Cho, Hyun;Kim, Jin-Kon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.4
    • /
    • pp.190-193
    • /
    • 2012
  • Transparent diamond-like carbon (DLC) films were synthesized on glass using radio frequency plasma enhanced chemical vapor deposition method from the gas mixture of $CH_4$, $SiH_4$ and Ar. The pressure, the rf-power, $CH_4/SiH_4/Ar$ ratio, and the deposition time were 0.1Torr, 100W, 20 : 1 : 1, and 20 min, respectively. The optical transmittances of DLC-deposited glass and uncoated glass were compared with each other in the visible light regions. The DLC-deposited glass showed transmittance of approximately 83 % and 95 % as compared to the uncoated glass for the wavelength of 380 nm and 500 nm, respectively. The hardness and roughness of DLC-coated glass have been measured by nanoindentation and AFM, respectively. The DLC-coated glass showed a little less or similar optical transmittance compared to the uncoated glass, while the hardness of DLC-coated glass was 2.5 times higher than that of the uncoated glass. The deposited DLC film had the very smooth surface and was thicker than 150 nm after deposition for 20 min.

Generalized Analysis on the Combined Effect of SPM and Fiber Chromatic Dispersion on Subcarrier Multiplexed Optical Transmission Systems for RoF Applications

  • Kim, Kyoung-Soo;Lee, Jae-Hoon;Jeong, Ji-Chai
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.132-139
    • /
    • 2011
  • We investigate theoretically the combined effect of fiber chromatic dispersion and self-phase modulation (SPM) on multi-channel subcarrier multiplexed (SCM) optical transmission systems in terms of the detected RF carrier power and SPM-induced power gain after transmission over single-mode fiber (SMF) links. According to the calculated power gain due to the SPM effect at the transmission distance of P3dB using the detected radio-frequency (RF) carrier power after photo-detection, the power gain is significantly degraded with large optical modulation index (OMI), small SCM channel spacing, and large fiber launching power because of the increased interaction between subcarrier channels. The nonlinear phase shift due to linear and nonlinear fiber characteristics is investigated to explain these results in detail. The numerical simulation results show that the OMI per SCM channel has to be smaller than 10 % for the fiber launching power of 10 dBm to guarantee prevention of SPM-induced power gain degradation below 0.5 dB for the SCM system with the channel spacing of 100 MHz. This result is expected to be utilized for the optical transmission systems using the SCM technology in future radio-over-fiber (RoF) networks.

Chaos QPSK Modulated Beamspace MIMO System Using ESPAR Antenna (ESPAR 안테나를 사용하는 카오스 QPSK 변조 빔 공간 MIMO 시스템)

  • Lee, Jun-Hyun;Bok, Jun-Yeong;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.2
    • /
    • pp.77-85
    • /
    • 2014
  • Recently, utilization of MIMO(Multi-Input Multi-Output) system using array antennas is evaluated significantly according to the extension of high-capacity and high-speed communication services. However, MIMO system has disadvantages such as high-complexity and high-power-consumption, because RF(Radio Frequency) chain is required as antenna number, and several array antenna is used in conventional MIMO system. In order to solve these problems, research about beamspace MIMO system using ESPAR(Electronically Steerable Parasitic Array Radiator) antenna that has single RF chain by using one active antenna and several parasitic elements has been studied actively. Beamspace MIMO system using ESPAR antenna is possible to solve the problems of conventional MIMO system, because this system is composed by single RF chain. In this paper, in order to improve the system security, chaos communication algorithm that has characteristics such as non-periodic, non-predictability, easy implementation and initial condition is applied to QPSK (Quadrature Phase Shift Keying) modulated beamspace MIMO system. We design the chaos QPSK modulated beamspace MIMO system, and evaluate SER performance of this system.

Fundamental Studies of Gas-jet Assisted Radio Frequency Glow Discharge Atomic Absorption Spectrometry (원자흡수법에 의한 Gas-Jet Assisted RF 글로우방전 시스템의 특성 연구)

  • Choi, Seong-Kyu;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.69-77
    • /
    • 1995
  • The instrumentation and operating characteristics of a gas-jet assisted radio frequency glow discharge atomic absorption spectrometry(RF-GDAAS) are studied. The roles of discharge power, pressure as well as gas flow rate on the sample loss rate and absorbance are described in this paper. Results show that the optimum discharge conditions depend on pressure and discharge power as well as on the gas flow rate. The gas flow rate plays as an important parameter in RF-GDAAS. Absorbance increases as the gas flow rate increase up to 600ml/min., and the optimum absorbance is obtained at the pressure of 3 mbar. The absorbance increases when the discharge power increases as expected, however, the instability of the system due to the heat might be the trade off factor. The linear calibration curves of Ni and Cr in stainless steel(BAS 461-468) and brass (KSS 1121-1126) are obtained with RF-GDAAS.

  • PDF