• Title/Summary/Keyword: Radiation treatment techniques

Search Result 182, Processing Time 0.025 seconds

Thallium-201 Uptake and Washout in T1-201 Brain SPECT of Various Brain Tumors (각종 뇌 종양의 Thallium-201 뇌 SPECT에서 Thallium-201의 동태)

  • Lim, Sang-Moo;Hong, Sung-Woon;Rhee, Chang-Hun;Lee, Seung-Hoon;Kim, Jong-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.360-364
    • /
    • 1992
  • Treatment for the brain tumors consist of surgery, chemotherapy, and a variety of methods of irradiation. Therapy is aimed to destroy the tumor, but necrosis and edema occur concurrently. Conventional structural imaging techniques such as CT or MRI are unable to reliably distinguish persistent and recurrent tumor from necrosis or edema. T1-201 has been shown to be useful in the evaluation of the myocardial viability by comparing the early uptake and redistribution image. The aim of this study is to evaluate the clinical usefulness of the early uptake and delayed washout images of the T1-201 brain SPECT in the brain tumors. In the pathologically diagnosed various brain tumor patients, brain SPECT was done with rotating gamma camera 15 minutes and 3 hours after T1-201 injection, and the T1-201 uptake in the tumor was compared with the skull and scalp activity. In the glioblastoma multiforme, meningioma and metastatic tumor, the T1-201 uptake was higher than low grade glioma in both 15 minute and 3 hour images (p<0.02). In the low grade glioma,3 hour T1-201 uptake was significantly lower than 15 minute uptake (p<0.05) but in the glioblastoma, meningioma and metastatic tumor there was no significant difference. There was no significant difference in the T1-201 uptake among the glioblastoma, meningioma and metastatic tumors. In one matastatic tumor, T1-201 uptake was decreased after radiation therapy. T1-201 brain SPECT could distinguish the benign and malignancy, and seems to be useful in the follow-up after treatment. But one of the early or delayed SPECT seems not to be necessary for these purposes.

  • PDF

Development of Drug Eluting Stent for the Treatment of Benign Biliary Stricture by Electro-spray Method (전기분사를 이용한 양성담관 협착 치료용 약물방출 스텐트 개발)

  • Shin, Il-Gyun;Kim, Dong-Gon;Kim, Han-Ki;Kim, Sang-Ho;Jeon, Dong-Min;Suh, Tae-Seok;Jang, Hong-Seok
    • Polymer(Korea)
    • /
    • v.36 no.2
    • /
    • pp.163-168
    • /
    • 2012
  • Recently, along with technology development of endoscopic equipment, the stent technology has been developed for the convenience of operation, shortening of recovery times, and reduction of patient's pain. In this study, paclitaxel-eluting metal stents for treatment of biliary benign stenosis were developed through an electrospray-coating method. Polyether-based polyurethane (PELLETHANE 2363-80AE$^{(R)}$)) and paclitaxel were coated onto the surface of a metallic stent and Pluronic F127 was used as an additive. As a result, physicochemical characterization of paclitaxel via SEM, FTIR, contact angle and XRD techniques revealed the information of solid state of paclitaxel-loaded PU film. The in vitro release profile showed a slower release rate with a higher content of paclitaxel.

Dosimetric Comparison of Intensity Modulated Radiation, Proton Beam Therapy and Proton Arc Therapy for Para-aortic Lymph Node Tumor (대동맥림프절 종양에 대한 세기조절방사선치료, 양성자치료, 양성자회전치료의 선량 비교평가)

  • Kim, JungHoon
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.331-339
    • /
    • 2014
  • To test feasibility of proton arc therapy (PAT) in the treatment of para-aortic lymph node tumor and compare its dosimetric properties with advanced radiotherapy techniques such as intensity modulated radiation therapy (IMRT) and conventional 3D conformal proton beam therapy (PBT). The treatment plans for para-aortic lymph node tumor were planned for 9 patients treated at our institution using IMRT, PBT, and PAT. Feasibility test and dosimetric evaluation were based on comparisons of dose volume histograms (DVHs) which reveal mean dose, $D_{30%}$, $D_{60%}$, $D_{90%}$, $V_{30%}$, $V_{60%}$, $V_{90%}$, organ equivalent doses (OEDs), normal tissue complication probability (NTCP), homogeneity index (HI) and conformity index (CI). The average doses delivered by PAT to the liver, kidney, small bowel, duodenum, stomach were 7.6%, 3%, 17.3%, 26.7%, and 14.4%, of the prescription dose (PD), respectively, which is higher than the doses delivered by IMRT (0.4%, 7.2%, 14.2%, 15.9%, and 12.8%, respectively) and PBT (4.9%, 0.5%, 14.12%, 16.1% 9.9%, respectively). The average homogeneity index and conformity index of tumor using PAT were 12.1 and 1.21, respectively which were much better than IMRT (21.5 and 1.47, respectively) and comparable to PBT (13.1 and 1.23, respectively). The result shows that both NTCP and OED of PAT are generally lower than IMRT and PBT. This study demonstrates that PAT is better in target conformity and homogeneity than IMRT and PBT but worse than IMRT and PBT for most of dosimetric factor which indicate that PAT is not recommended for the treatment of para-aortic lymph node tumor.

Segmentation and Visualization of Human Anatomy using Medical Imagery (의료영상을 이용한 인체장기의 분할 및 시각화)

  • Lee, Joon-Ku;Kim, Yang-Mo;Kim, Do-Yeon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.1
    • /
    • pp.191-197
    • /
    • 2013
  • Conventional CT and MRI scans produce cross-section slices of body that are viewed sequentially by radiologists who must imagine or extrapolate from these views what the 3 dimensional anatomy should be. By using sophisticated algorithm and high performance computing, these cross-sections may be rendered as direct 3D representations of human anatomy. The 2D medical image analysis forced to use time-consuming, subjective, error-prone manual techniques, such as slice tracing and region painting, for extracting regions of interest. To overcome the drawbacks of 2D medical image analysis, combining with medical image processing, 3D visualization is essential for extracting anatomical structures and making measurements. We used the gray-level thresholding, region growing, contour following, deformable model to segment human organ and used the feature vectors from texture analysis to detect harmful cancer. We used the perspective projection and marching cube algorithm to render the surface from volumetric MR and CT image data. The 3D visualization of human anatomy and segmented human organ provides valuable benefits for radiation treatment planning, surgical planning, surgery simulation, image guided surgery and interventional imaging applications.

Development of Independent Target Approximation by Auto-computation of 3-D Distribution Units for Stereotactic Radiosurgery (정위적 방사선 수술시 3차원적 공간상 단위분포들의 자동계산법에 의한 간접적 병소 근사화 방법의 개발)

  • Choi Kyoung Sik;Oh Seung Jong;Lee Jeong Woo;Kim Jeung Kee;Suh Tae Suk;Choe Bo Young;Kim Moon Chan;Chung Hyun-Tai
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.24-31
    • /
    • 2005
  • The stereotactic radiosurgery (SRS) describes a method of delivering a high dose of radiation to a small tar-get volume in the brain, generally in a single fraction, while the dose delivered to the surrounding normal tissue should be minimized. To perform automatic plan of the SRS, a new method of multi-isocenter/shot linear accelerator (linac) and gamma knife (GK) radiosurgery treatment plan was developed, based on a physical lattice structure in target. The optimal radiosurgical plan had been constructed by many beam parameters in a linear accelerator or gamma knife-based radiation therapy. In this work, an isocenter/shot was modeled as a sphere, which is equal to the circular collimator/helmet hole size because the dimension of the 50% isodose level in the dose profile is similar to its size. In a computer-aided system, it accomplished first an automatic arrangement of multi-isocenter/shot considering two parameters such as positions and collimator/helmet sizes for each isocenter/shot. Simultaneously, an irregularly shaped target was approximated by cubic structures through computation of voxel units. The treatment planning method by the technique was evaluated as a dose distribution by dose volume histograms, dose conformity, and dose homogeneity to targets. For irregularly shaped targets, the new method performed optimal multi-isocenter packing, and it only took a few seconds in a computer-aided system. The targets were included in a more than 50% isodose curve. The dose conformity was ordinarily acceptable levels and the dose homogeneity was always less than 2.0, satisfying for various targets referred to Radiation Therapy Oncology Group (RTOG) SRS criteria. In conclusion, this approach by physical lattice structure could be a useful radiosurgical plan without restrictions in the various tumor shapes and the different modality techniques such as linac and GK for SRS.

  • PDF

Development of an Automatic Seed Marker Registration Algorithm Using CT and kV X-ray Images (CT 영상 및 kV X선 영상을 이용한 자동 표지 맞춤 알고리듬 개발)

  • Cheong, Kwang-Ho;Cho, Byung-Chul;Kang, Sei-Kwon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Suh, Tae-Suk
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.54-61
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: The purpose of this study is to develop a practical method for determining accurate marker positions for prostate cancer radiotherapy using CT images and kV x-ray images obtained from the use of the on- board imager (OBI). $\underline{Materials\;and\;Methods}$: Three gold seed markers were implanted into the reference position inside a prostate gland by a urologist. Multiple digital image processing techniques were used to determine seed marker position and the center-of-mass (COM) technique was employed to determine a representative reference seed marker position. A setup discrepancy can be estimated by comparing a computed $COM_{OBI}$ with the reference $COM_{CT}$. A proposed algorithm was applied to a seed phantom and to four prostate cancer patients with seed implants treated in our clinic. $\underline{Results}$: In the phantom study, the calculated $COM_{CT}$ and $COM_{OBI}$ agreed with $COM_{actual}$ within a millimeter. The algorithm also could localize each seed marker correctly and calculated $COM_{CT}$ and $COM_{OBI}$ for all CT and kV x-ray image sets, respectively. Discrepancies of setup errors between 2D-2D matching results using the OBI application and results using the proposed algorithm were less than one millimeter for each axis. The setup error of each patient was in the range of $0.1{\pm}2.7{\sim}1.8{\pm}6.6\;mm$ in the AP direction, $0.8{\pm}1.6{\sim}2.0{\pm}2.7\;mm$ in the SI direction and $-0.9{\pm}1.5{\sim}2.8{\pm}3.0\;mm$ in the lateral direction, even though the setup error was quite patient dependent. $\underline{Conclusion}$: As it took less than 10 seconds to evaluate a setup discrepancy, it can be helpful to reduce the setup correction time while minimizing subjective factors that may be user dependent. However, the on-line correction process should be integrated into the treatment machine control system for a more reliable procedure.

Verification of Non-Uniform Dose Distribution in Field-In-Field Technique for Breast Tangential Irradiation (유방암 절선조사 시 종속조사면 병합방법의 불균등한 선량분포 확인)

  • Park, Byung-Moon;Bae, Yong-Ki;Kang, Min-Young;Bang, Dong-Wan;Kim, Yon-Lae;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.277-282
    • /
    • 2010
  • The study is to verify non-uniform dose distribution in Field-In-Field (FIF) technique using two-dimensional ionization chamber (MatriXX, Wellhofer Dosimetrie, Germany) for breast tangential irradiation. The MatriXX and an inverse planning system (Eclipse, ver 6.5, Varian, Palo Alto, USA) were used. Hybrid plans were made from the original twenty patients plans. To verify the non-uniform dose distribution in FIF technique, each portal prescribed doses (90 cGy) was delivered to the MatriXX. The measured doses on the MatriXX were compared to the planned doses. The quantitative analyses were done with a commercial analyzing tool (OmniPro IMRT, ver. 1.4, Wellhofer Dosimetrie, Germany). The delivered doses at the normalization points were different to average 1.6% between the calculated and the measured. In analysis of line profiles, there were some differences of 1.3-5.5% (Avg: 2.4%), 0.9-3.9% (Avg: 2.5%) in longitudinal and transverse planes respectively. For the gamma index (criteria: 3 mm, 3%) analyses, there were shown that 90.23-99.69% (avg: 95.11%, std: 2.81) for acceptable range ($\gamma$-index $\geq$ 1) through the twenty patients cases. In conclusion, through our study, we have confirmed the availability of the FIF technique by comparing the calculated with the measured using MatriXX. In the future, various clinical applications of the FIF techniques would be good trials for better treatment results.

Evidence Based Approach of Wheel Balance Cancer Therapy: A Review (수레바퀴 암 치료법에 대한 근거중심적 연구)

  • Zheng, Hongmei;Yoon, Jeungwon;Yoo, Hwa-Seung;Cho, Chong-Kwan
    • Journal of Korean Traditional Oncology
    • /
    • v.17 no.2
    • /
    • pp.1-16
    • /
    • 2012
  • Background : Integrative cancer treatment is a holistic approach embracing body, mind, and spirit incorporating conventional treatments of surgery, chemotherapy, radiation and personalized complementary treatments. Wheel Balance Therapy (WBT) of East-West Cancer Center(EWCC), Dunsan Oriental Hospital of Daejeon University was developed to balance out all factors involved in cancer care based on the traditional theories of oriental medicine. Objective : This work aims to analytically review literatures on WBT and its related components. Methods : Literatures published from January 1st, 1990 to April 30th, 2011 were reviewed focusing on 4 main components of WBT; herbal medicine, immune activation, anti-cancer diet, and breathing/meditation. Data were retrieved from medical search engines and electronic data bases including Pubmed, Research Information sharing Service (RISS), Korean-studies Information Service System (KISS), China National Knowledge Infrastructure (CNKI), and Korea's National Digital Library (KNDL). Results : In this review, EWCC's most commonly prescribed formulas are explored. The composition of the formulas, their use in clinical settings as well as the background studies and other therapeutic efficacies are explained. Information on incorporating anti-cancer dietary support and breathing and meditation techniques, other therapies practiced as part of the center's integrative cancer care are also covered. Conclusion : WBT based on holistic theories of oriental medicine embracing body, mind, and spirit is expected to further contribute in promotion of cancer patients' quality of life and prolonged survival time.

Clinical Application of DIAGNOcam (DIAGNOcam의 임상적 적용)

  • Kim, Jinhyock;Kim, Jongsoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.4
    • /
    • pp.461-466
    • /
    • 2016
  • Dental caries is an important dental disease among children and adolescents that can continue for a lifetime. Early detection of dental caries in deciduous dentition is significant because it can influence the permanent teeth. It is also critical to prevent dental caries by performing fluoride treatment and pit-and-fissure sealant for high-risk children. Various methods have been developed for the early detection of dental caries; however, many studies are still seeking to discover more effective methods. In general, visual examination and radiographic images are used, but these techniques have several limitations such as errors and radiation exposure. In this study, clinical application of the newly developed DIAGNOcam caries identification device and its possible applications were examined. DIAGNOcam was applied to diagnose dental caries in the posterior teeth of patients in the Department of Pediatric Dentistry, and it was confirmed that it could be used to detect proximal caries, the margin of restoration, and the extent of dental caries lesions.

A Study on ARC Therapy of 18MeV Linear Accelerator (18MeV 선형가속기의 ARC Therapy에 관한 고찰)

  • Kim, Sung-Kyu;Shin, Sei-One;Kim, Myung-Se
    • Journal of Yeungnam Medical Science
    • /
    • v.5 no.2
    • /
    • pp.31-36
    • /
    • 1988
  • In recent years there has been a growing interest in all forms of rotational therapy, and many different types of therapy machines designed for this kind of treatment have become available. To the medical radiation physicist, the dosimetry of rotation therapy has presented a number of interesting problems, and much useful work has been published on the basic data of dose distribution and dosage calculation. The setting dose for ARC therapy were obtained by computer calculation and measurement with cylindrical phantom. Authors compared computer calculation with measured value. And in ARC therapy, the region of maximum dose is shifted from the tumor center. The extent of shift was analyzed by isodose distribution for ARC therapy techniques.

  • PDF