Radiological Characteristics of Materials Used in 3-Dimensional Printing with Various Infill Densities

  • Park, So-Yeon;Choi, Noorie;Choi, Byeong Geol;Lee, Dong Myung;Jang, Na Young
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.155-159
    • /
    • 2019
  • Radiological properties of newly introduced and existing 3-dimensional (3D) printing materials were evaluated by measuring their Hounsfield units (HUs) at varying infill densities. The six materials for 3D printing which consisted of acrylonitrile butadiene styrene (ABS), a unique ABS plastic blend manufactured by Zortrax (ULTRAT), high impact polystyrene (HIPS), polyethylene terephthalate glycol (PETG), polylactic acid (PLA), and a thermoplastic polyester elastomer manufactured by Zortrax (FLEX) were used. We used computed tomography (CT) imaging to determine the HU values of each material, and thus assess its suitability for various applications in radiation oncology. We found that several material and infill density combinations resembled the HU values of fat, soft tissues, and lungs; however, none of the tested materials exhibited HU values similar to that of bone. These results will help researchers and clinicians develop more appropriate instruments for improving the quality of radiation therapy. Using optimized infill densities will help improve the quality of radiation therapy by producing customized instruments for each field of radiation therapy.

전산화단층 모의치료장치의 정도관리 항목 제안 (Proposal of CT Simulator Quality Assurance Items)

  • 김연래;윤영우;정재용;이정우;정진범
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권4호
    • /
    • pp.367-373
    • /
    • 2021
  • A quality assurance of computed tomography(CT) have done seven items that were water attenuation coefficient, noise, homogeneity, spatial resolution, contrast resolution, slice thickness, artifact using by standard phantom. But there is no quality assurance items and methods for CT simulator at domestic institutions yet. Therefore the study aimed to access the CT dose index(CTDI), table tilting, image distortion, laser accuracy, table movement accuracy and CT seven items for CT simulator quality assurance. The CTDI at the center of the head phantom was 0.81 for 80 kVp, 1.55 for 100 kVp, 2.50 for 120 mm, 0.22 for 80 kVp at the center of the body phantom, 0.469 for 100 kVp, and 0.81 for 120 kVp. The table tilting was within the tolerance range of ±1.0° or less. Image distortion had 1 mm distortion in the left and right images based on the center, and the laser accuracy was measured within ±2 mm tolerance. The purpose of this study is to improve the quality assurance items suitable for the current situation in Korea in order to protect the normal tissues during the radiation treatment process and manage the CT simulator that is implemented to find the location of the tumor more clearly. In order to improve the accuracy of the CT simulator when looking at the results, the error range of each item should be small. It is hoped that the quality assurance items of the CT simulator will be improved by suggesting the quality assurance direction of the CT simulator in this study, and the results of radiation therapy will also improve.

감마선 조사 분말수정과의 저장 중 관능적 품질특성 및 유전독성학적 안전성 평가 (Evaluation of the Sensory Quality Characteristics during Storage and Mutagenicity of Gamma-irradiated Sujeonggwa Powder (Korean Traditional Cinnamon Beverage))

  • 이현자;설민숙;박재남;김재훈;송범석;이주운;변명우
    • 한국식품저장유통학회지
    • /
    • 제14권4호
    • /
    • pp.408-413
    • /
    • 2007
  • 본 연구는 감마선 조사된 분말수정과의 저장 중 관능적 품질특성 변화 및 돌연변이원성을 평가하고자 실시되었다. 미생물 분석결과 멸균을 위한 최소선량은 약 4.5 kGy인 것으로 확인되었다. 감마선 조사된 시료들의 관능평가를 실시한 결과 조사선량이 증가할수록 모든 평가항목에 감소하는 경향이었으며, 색도의 변화를 평가한 결과 감마선 조사선량이 증가함에 따라 명도($L^*$)는 유의적으로 증가하고 적색도($a^*$) 및 황색도($b^*$)는 유의적으로 낮아지는 경향을 나타내었다. S. typhimurium TA98, TA100을 이용한 돌연변이원성 실험에서 감마선 조사군의 전 용량단계에서 음성대조군과 동일한 수준의 돌연변이 집락수를 보여 돌연변이 유발성이 없는 것으로 나타났다.

치즈와 향신료의 첨가가 감마선 조사된 타락죽의 관능적 품질에 미치는 영향 (Effect of Cheeses and Flavors on Sensory Properties of Gamma-irradiated Tarakjuk)

  • 한인준;윤영민;최수정;송범석;김재경;박종흠;이주운;전순실;김재훈
    • 방사선산업학회지
    • /
    • 제6권2호
    • /
    • pp.111-117
    • /
    • 2012
  • This study was conducted to improve organoleptic quality of gamma-irradiated Tarakjuk at 10 kGy with cheeses (Camembert, Cheddar, Gouda, and Edam) and flavors (Nurungji, cream, and vanilla-cream). Overall acceptability of gamma-irradiated Tarakjuk added each camembert cheese and vanilla-cream flavor was the highest among the all samples. In the effect of sterilization method on the quality of Tarakjuk, the autoclaved samples added with Edam cheese, Gouda cheese, and vanilla-cream flavor, respectively, were showed higher score on the overall acceptability than the irradiated samples, meanwhile the irradiated samples were superior in the other samples. In case of added mixture of Edam cheese and vanilla-cream flavor, irradiated Tarakjuk with mixture was showed the most of high score on overall acceptability. In conclusion, addition of mixture of cheese and flavor to Tarakjuk may help to improve organoleptic quality of sterilized Tarakjuk by gammairradiation.

가루녹차가 유과의 품질 특성에 미치는 영향 (Effect of Green Tea Powder on the Quality Characteristics of Yukwa (Korean Fried Rice Cake))

  • 박재남;권석임;김종군;박진규;한인준;송범석;김재훈;변명우;이주운
    • 한국식품저장유통학회지
    • /
    • 제15권1호
    • /
    • pp.37-42
    • /
    • 2008
  • 본 연구는 유과의 저장안전성 및 관능적 품질개선을 위한 연구의 일환으로 가루녹차를 첨가하여 유과를 제조한 후 품질특성을 비교 평가하고 최종적으로 가루녹차 첨가 유과의 품질 및 저장성 증진에 미치는 영향을 평가하고자 실시하였다. 그 결과 가루녹차 1, 2, 3% 첨가량에 따른 수분 함량은 변화가 없었으며, 조지방 함량은 첨가량이 증가할수록 유의적으로 낮아지는 것으로 나타났다. 가루녹차 첨가 유과의 기공크기와 팽화율은 가루녹차 첨가량이 증가할수록 감소하는 것으로 나타났으며 유과의 경도는 2% 이상의 가루녹차 첨가시 유의적으로 증가하였다. 관능평가 결과 녹차첨가량이 증가할수록 모든 평가항복에서 유의적으로 낮은 점수를 얻었으나 1%의 첨가구는 대조구와 유의적인 차이가 없었다. 항산화 효과는 가루녹차 첨가량이 증가할수록 증가되었으며 이러한 결과들에 의해 1% 가루녹차의 첨가가 품질 및 저장성 향상에 적합한 것으로 판단되었다.

Intensity-modulated radiation therapy: a review with a physics perspective

  • Cho, Byungchul
    • Radiation Oncology Journal
    • /
    • 제36권1호
    • /
    • pp.1-10
    • /
    • 2018
  • Intensity-modulated radiation therapy (IMRT) has been considered the most successful development in radiation oncology since the introduction of computed tomography into treatment planning that enabled three-dimensional conformal radiotherapy in 1980s. More than three decades have passed since the concept of inverse planning was first introduced in 1982, and IMRT has become the most important and common modality in radiation therapy. This review will present developments in inverse IMRT treatment planning and IMRT delivery using multileaf collimators, along with the associated key concepts. Other relevant issues and future perspectives are also presented.

방사선 치료를 받은 암환자의 삶의 질과 관련요인 (Quality of Life and Its Related Factors of Radiation Therapy Cancer Patients)

  • 신령미;정원석;오병천;조준영;김기철;최태규;이석구
    • 대한방사선치료학회지
    • /
    • 제23권1호
    • /
    • pp.21-29
    • /
    • 2011
  • 목 적: 방사선 치료를 받은 암환자의 삶의 질에 영향을 미치는 관련요인을 분석하여 암환자가 가지고 있는 신체적, 정신적 문제들에 대한 삶의 질 정보를 획득하고 향후 방사선 치료를 받은 암환자의 삶의 질을 개선하기 위한 기초 자료로 활용하고자 한다. 대상 및 방법: 2010년 7월 15일부터 8월 15일까지 대전광역시 내 대학병원에서 방사선 치료를 받은 경험이 있는 환자 107명을 대상으로 다양한 특성과 지지 형태에 대한 구조화된 설문지를 이용하여 조사하고 삶의 질에 영향을 미치는 요인을 분석하였다. 결 과: 질환으로 인한 통증이 있는 경우가 65.61점, 질환으로 인한 통증이 없는 경우가 81.87점으로 통증이 없는 경우에서 삶의 질 점수가 높게 나타났고 체중이 감소할수록 삶의 질 점수가 낮아졌으며 경제적 특성에 따른 삶의 질 점수를 비교한 결과 치료기간을 제외한 모든 항목에서 유의한 차이를 나타내었다(P=0.000). 사회적지지, 가족지지, 의료인지지, 자아존중감의 점수가 낮은 경우 삶의 질 점수는 128점 만점에 각각 61.71, 68.77, 71.31, 69.39점으로 나타났으며 반면 지지유형의 점수가 높은 경우 삶의 질 점수는 각각 90.47, 83.29, 90.40, 90.36점으로 나타났다(P<0.05). 대상자의 사회적지지, 가족지지, 의료인지지, 자아존중감과 삶의 질 정도의 상관관계를 분석하여 본 결과 사회적지지 0.768, 가족지지 0.596, 의료인지지 0.434, 자아존중감 0.516으로 통계학적으로 유의한 양의 상관관계를 나타내었다(P<0.01). 삶의 질과 관련이 있는 요인으로는 결혼을 한 경우가 결혼을 하지 않은 경우보다 삶의 질이 증가하였고 직업을 가진 경우가 직업이 없는 경우보다 삶의 질이 증가하여 나타났다. 또한 통증이 있는 경우보다 통증이 없는 경우에서 삶의 질이 증가하였으며 월평균 수입이 증가할수록 삶의 질이 높게 나타났다(P<0.05). 사회적지지, 의료인지지가 높을수록 삶의 질은 0.979배, 0.508배 높게 나타났으며 자아존중감이 높을수록 1.667배 삶의 질이 증가하였다. 결 론: 방사선 치료를 받은 암환자의 삶의 질은 사회적지지, 의료인지지, 자아존중감과 유의한 관련이 있었음을 알 수 있었다. 자아존중감은 삶의 질에 영향을 미치는 요인이므로 국가가 정책적으로 질병에 영향이 가지 않는 선의 업무를 부여하여 소득을 창출한다면 자아존중감을 극대화시키는 동시에 경제적 부담을 감소시킬 수 있는 유용한 방법이 될 것이다. 더불어 의료진의 관심과 암환자 가족을 위한 프로그램 등의 기초자료 개발은 암환자와 가족, 더 나아가 의료진 모두가 한마음이 되어 암환자의 삶의 질을 높일 수 있는 지표가 될 수 있을 것이라 사료된다.

  • PDF

유방촬영장치의 타깃에 따른 에너지스펙트럼 및 팬텀영상화질 (The energy spectrum and phantom image quality according to mammography target-filter combinations)

  • 장세영;오왕균;박종배;진계환
    • 한국방사선학회논문지
    • /
    • 제7권1호
    • /
    • pp.51-55
    • /
    • 2013
  • 엑스선의 에너지가 높으면 엑스선이 피사체(object)를 통과하여 영상의 대조도를 떨어뜨리고 엑스선의 에너지가 낮으면 영상의 대조도는 증가시키지만 엑스선이 피사체에 흡수되어 환자의 피폭선량을 증가시킨다. 그러므로 적정한 엑스선 에너지는 영상의 질과 피폭선량에 영향을 미치는 매우 중요한 요소이다. 본 논문에서는 새로운 양극물질을 사용하는 유방촬영 장치의 도입에 따라 방사선 선질이 다양해진 유방촬영장치의 영상품질관리와 환자선량관리을 위하여 유방촬영장치의 타겟 물질에 따른 에너지스펙트럼을 시뮬레이션하고 팬텀 영상의 화질을 비교하였다.

방사선치료에서의 품질보증을 위한 통계적공정관리의 활용 (Use of Statistical Process Control for Quality Assurance in Radiation Therapy)

  • 정광호
    • 한국의학물리학회지:의학물리
    • /
    • 제26권2호
    • /
    • pp.59-71
    • /
    • 2015
  • 품질보증의 목적은 공정의 품질을 유지하기 위하여 계통적인 오류를 최소화하는 것이다. 통계적공정관리는 2005년 이후 방사선치료분야에서도 이용되기 시작하였으며 품질보증의 패러다임을 바꾸어가고 있다. 통계적공정관리의 목적은 공정의 안정성을 관리한계 내에서 유지하며 변동의 양상도 감시하기 위한 것이다. 통계적공정관리는 방사선치료 품질보증 전 분야에 적용 가능하지만, 이를 제대로 활용하기 위해서는 통계적공정관리에 대한 지식이 필요하다. 본 논문에서는 통계적공정관리의 개념을 설명하고 방사선치료분야에서 이를 활용한 연구들을 소개하였다.

Tube Voltage, DNA Double-Strand Breaks, and Image Quality in Coronary CT Angiography

  • Zhu Xiao Lin;Fan Zhou;U. Joseph Schoepf;Balakrishnan Pillai;Chang Sheng Zhou;Wei Quan;Xue Qin Bao;Guang Ming Lu;Long Jiang Zhang
    • Korean Journal of Radiology
    • /
    • 제21권8호
    • /
    • pp.967-977
    • /
    • 2020
  • Objective: To evaluate the effects of tube voltage on image quality in coronary CT angiography (CCTA), the estimated radiation dose, and DNA double-strand breaks (DSBs) in peripheral blood lymphocytes to optimize the use of CCTA in the era of low radiation doses. Materials and Methods: This study included 240 patients who were divided into 2 groups according to the DNA DSB analysis methods, i.e., immunofluorescence microscopy and flow cytometry. Each group was subdivided into 4 subgroups: those receiving CCTA only with different tube voltages of 120, 100, 80, or 70 kVp. Objective and subjective image quality was evaluated by analysis of variance. Radiation dosages were also recorded and compared. Results: There was no significant difference in demographic characteristics between the 2 groups and 4 subgroups in each group (all p > 0.05). As tube voltage decreased, both image quality and radiation dose decreased gradually and significantly. After CCTA, γ-H2AX foci and mean fluorescence intensity in the 120-, 100-, 80-, and 70-kVp groups increased by 0.14, 0.09, 0.07, and 0.06 foci per cell and 21.26, 9.13, 8.10, and 7.13 (all p < 0.05), respectively. The increase in the DNA DSB level in the 120-kVp group was higher than those in the other 3 groups (all p < 0.05), while there was no significant difference in the DSBs levels among these latter groups (all p > 0.05). Conclusion: The 100-kVp tube voltage may be optimal for CCTA when weighing DNA DSBs against the estimated radiation dose and image quality, with further reductions in tube voltage being unnecessary for CCTA.