References
- Pawlicki T, Mundt AJ: Quality in radiation oncology. Med. Phys. 34(5):1529-1534 (2007) https://doi.org/10.1118/1.2727748
- Klein EE, Hanley J, Bayouth J, et al.: Task group 142 report: Quality assurance of medical accelerators. Med. Phys. 36(9):4197-4212 (2009) https://doi.org/10.1118/1.3190392
- Lee SH: Engineering Statistics and Data Analysis using Minitab, EreTec (2008)
- AIAG: Statistical process control (SPC) reference manual 2nd ed., AIAG (2005)
- Pawlicki T, Chera B, Ning T, Marks LB: The systematic application of quality measures and process control in clinical radiation oncology. Semin. Radiat. Oncol. 22(1):70-76 (2012) https://doi.org/10.1016/j.semradonc.2011.09.006
- Pawlicki T, Whitaker M: Variation and control of process behavior. Int. J. Radiat. Oncol. Biol. Phys. 71(1 Suppl):S210-4 (2008) https://doi.org/10.1016/j.ijrobp.2007.05.096
- http://en.wikipedia.org/wiki/Control_chart
- Sanghangthum T, Suriyapee S, Srisatit S, Pawlicki T: Retrospective analysis of linear accelerator output constancy checks using process control techniques. J. Appl. Clin. Med. Phys. 14(1):4032 (2013)
- Gerard K, Grandhaye JP, Marchesi V, Kafrouni H, Husson F, Aletti P: A comprehensive analysis of the IMRT dose delivery process using statistical process control (SPC). Med. Phys. 36(4):1275-1285 (2009) https://doi.org/10.1118/1.3089793
- Oh SA, Yea JW, Kim SW, Lee R, Kim SK: Analysis of output constancy checks using process control techniques in linear accelerators. Progress. Med. Phys. 25(3):185-192 https://doi.org/10.14316/pmp.2014.25.3.185
- Able CM, Hampton CJ, Baydush AH, Munley MT: Initial investigation using statistical process control for quality control of accelerator beam steering. Radiat. Oncol. 6180-717X-6-180 (2011)
- Han Y: Review on the pre-treatment quality assurance for intensity modulated radiation therapy. Progress. Med. Phys. 24(4):213-219 (2014) https://doi.org/10.14316/pmp.2013.24.4.213
- Basran PS, Woo MK: An analysis of tolerance levels in IMRT quality assurance procedures. Med. Phys. 35(6):2300-2307 (2008) https://doi.org/10.1118/1.2919075
- Gordon JD, Krafft SP, Jang S, Smith-Raymond L, Stevie MY, Hamilton RJ: Confidence limit variation for a single IMRT system following the TG119 protocol. Med. Phys. 38(3): 1641-1648 (2011) https://doi.org/10.1118/1.3555298
- Sanghangthum T, Suriyapee S, Srisatit S, Pawlicki T: Statistical process control analysis for patient-specific IMRT and VMAT QA. J. Radiat. Res. 54(3):546-552 (2013) https://doi.org/10.1093/jrr/rrs112
- Palaniswaamy G, Scott Brame R, Yaddanapudi S, Rangaraj D, Mutic S: A statistical approach to IMRT patient-specific QA. Med. Phys. 39(12):7560-7570 (2012) https://doi.org/10.1118/1.4768161
- Gagneur JD, Ezzell GA: An improvement in IMRT QA results and beam matching in linacs using statistical process control. J. Appl. Clin. Med. Phys. 15(5):4927 (2014)
- Pawlicki T, Yoo S, Court LE, et al.: Moving from IMRT QA measurements toward independent computer calculations using control charts. Radiother. Oncol. 89(3):330-337 (2008) https://doi.org/10.1016/j.radonc.2008.07.002
- Cheong KH, Lee MY, Kang SK, et al.: Statistical quality control for volumetric modulated arc therapy (VMAT) delivery by using the machine's log data. J. Kor. Phys. Soc. (Article in press, 2015)
- Rah JE, Shin D, Oh DH, Kim TH, Kim GY: Feasibility study of using statistical process control to customized quality assurance in proton therapy. Med. Phys. 41(9):092105 (2014) https://doi.org/10.1118/1.4893916
- Pawlicki T, Whitaker M, Boyer AL: Statistical process control for radiotherapy quality assurance. Med. Phys. 32(9): 2777-2786 (2005) https://doi.org/10.1118/1.2001209
- http://Cran.r-project.org/index.html
- http://www.hanyang.ac.kr/english/ezspc.html
Cited by
- 국내 선형가속기의 포괄적인 품질관리체계에 대한 제언 vol.26, pp.4, 2015, https://doi.org/10.14316/pmp.2015.26.4.294
- Statistical process control analysis for patient quality assurance of intensity modulated radiation therapy vol.71, pp.10, 2015, https://doi.org/10.3938/jkps.71.717
- The Development of New Cost-Effective Optimization Technology for OLED Market Entry vol.17, pp.4, 2015, https://doi.org/10.15722/jds.17.4.201904.51