Proposal of CT Simulator Quality Assurance Items
![]() |
Kim, Yon-Lae
(Department of Radiologic Technology, Choonhae College of Health Science)
Yoon, Young-Woo (Department of Radiologic Technology, Choonhae College of Health Science) Jung, Jae-Yong (Department of Radiation Oncology, Sanggye Paik Hospital) Lee, Jeong-Woo (Department of Radiation Oncology, Konkuk University Hospital) Chung, Jin-Beom (Department of Radiation Oncology, Seoul National University Bundang Hospital) |
1 | Ku EW, Lee JS, Cho JK, Moon SK. An efficient correction process of CT-simulator couch with current diagnostic CT scanners. The Journal of Korea Contents Association. 2009;9(11):254-61. DOI |
2 | Kim JW, Lee JK, Lee MS, Shin DO, Kim YH, Park SY. Acceptance test and quality control of radiotherapy treatment simulator. Journal of Korean Medical Physics. 2002;13(2):90-7. |
3 | Ministry of Health and Welfare. Rules for the installation and operation of special medical equipment. 2019. |
4 | Sasa M, Jatinder RP, Elizabeth KB, Indra JD, Saiful H, Leh-Nien DL, et al. Quality assurance for computed-tomography simulators and the computed tomography-simulation process: Report of the AAPM radiation therapy committee task group No. 66. American Association of Physicists in Medicine; 2005. |
5 | Philippe D, Stewart G. COMP report: CPQR technical quality control guidelines for CT simulators. J Appl Clin Med Phys. 2018;19(2):12-7. DOI |
6 | Zakaria GA. Quality assurance in radiotherapy: Simulators, cone beam CT, EPID and immobilization devices. Academic Teaching Hospital of the University of Cologne; 2012. |
7 | Kim YK, Kim YM. Comparison of estimated and measured doses of dual-energy computed tomography. Journal of Radiological Science and Technology. 2018;41(5):405-11. DOI |
8 | Li XN, Wang D, Li GF, Xiao SH. Quality assurance on accuracy of the external laser centre in CT simulator. Chinese Journal of Radiation Oncology. 2006;(6):481-3. |
9 | Huaiqun G, Rabin H, Yin FF. A positioning QA procedure of 2D/2D(kV/MV) and 3D/3D(CT/CBCT) image matching for radiotherapy patient setup. Journal of Applied Clinical Medical Physics. 2009;10(4):273-80. DOI |
10 | Tomic N, Aldelaijan S, Rajala J, Seuntjens J, Devic S. Image quality of radiotherapy CT simulator with different scanner bore size. Physica Medica. 2018;45:65-71. DOI |
11 | An HJ, Son JM, Jin HM, Sung JW, Chun MS. Acceptance Test and Clinical Commissioning of CT Simulator. Progress in Medical Physics. 2019;0(4):160-166 |
12 | Ku EW, Lee JS, Cho JK, Moon SK. An Efficient Correction Process of CT-Simulator Couch with Current Diagnostic CT Scanners. The Journal of Korea Contents Association. 2009;9(11):254-261. DOI |
13 | Yoon MS, Hong SM, Heo YC, Han DK. Computed Tomography, Quality assurance, Image qulality, AAPM CT phantom, 3D printer. Journal of Radiological Science and Technology. 2018;41(6):595-602. DOI |
14 | Min CK, Yi BY, Ahn SD, Choi EK, Chang HS. A CT simulator phantom for geometrical test. The Journal of the Korean Society for Therapeutic Radiology and Oncology. 2000;18(4):329-36. |
15 | Hwang SH, Min JS, Lee JH, Park HD. Efficiency evaluation of CT simulator QA phantom. The Journal of Korean Society for Radiation Therapy. 2009;21(2):89-95. |
![]() |