• Title/Summary/Keyword: Radiation pressure

Search Result 690, Processing Time 0.03 seconds

Synthesis of Silica Aerogel at Ambient Pressure and Characterization (II) (실리카 에어로겔의 상압합성 및 특성연구(II))

  • 권영근;최세영;강신규
    • Journal of the Korean Ceramic Society
    • /
    • v.36 no.11
    • /
    • pp.1189-1197
    • /
    • 1999
  • Low-density silica gel monolith was synthesized at ambient pressure by surface modification with TMCS and sub-sequent heat treatment. The mechanical thermal and optical properties of gel were studied. Compressive strength and modulus of compression of 350$^{\circ}C$-heated gel with the density of 0.24g/cm3 were 250kPa and 0.2MPa respectively. The thermal conductivity of silica gels synthesized at ambient pressure exhibited 0.02 W/m$.$K for the density of 0.24g/cm3 which is similar to that of the gel via supercritical drying and their main thermal transfer mechanism is considered to be solid and radiation conduction at room temperature. Ambient-dried silica gels were transparent blue showing about 60% of transmittance in the wavelength of 1500-2100nm and typical absorption bands of existing bonds under heat treatment at 350$^{\circ}C$. Medium scale monolity(${\Phi}$=50mm) at ambient pressure could be successfully prepared through total 5-month process period.

  • PDF

A Study of the Pollutant Formation and Spectral Radiation Properties in Ceramic Fiber Radiant Burner (세라믹 화이버 버너의 배기 배출물과 분광학적 특성에 관한 연구)

  • Jeong, Yong-Ki;Kim, Young-Soo;Lee, Dae-Rae;Yang, Dae-Bong;Ryu, Jung-Wan;Yun, Alexander;Ha, Man-Young;Chang, Young-June;Jeon, Chung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.9
    • /
    • pp.790-798
    • /
    • 2007
  • An experimental study was performed to investigate the effects of mixing quality, inlet pressure, nozzle diameter on CO, NO emission and radiation characteristics in porous ceramic fiber radiant burners. Observations of combustion characteristics occurring inside the burner system which was insulated fiber mat, were investigated by measuring emission and radiation characteristics. Combustion was achieved at the firing rate of $88{\sim}99\;kcal/hr$, inlet pressure of $100{\sim}250mmH_2O$. The fiber burner exhibit significant both spectral intensity peaks in the bands at $2.5{\mu}m\;and\;4.0{\mu}m$ relatively. There is a small difference in the variable mixing tube. However spectral intensity increased with the firing rate. CO emissions were found to be strongly dependent on the operating conditions. There was a tendency that CO concentration increased as the firing rate increases. the reason for rise of CO concentration is that is becomes it the relatively rich condition. Relatively low NO emission was observed for the whole operating range. The NO concentration is maximal at the firing rate of approximately 2850 kcal/hr and an air ratio of about 1.

Effects of Geometric Configuration on the Vibro-acoustic Characteristics of Radial Vibration of an Annular Disc (환형 디스크 형상이 래디얼 진동에 의한 음향방사 특성에 미치는 영향)

  • Lee, Hyeong-Ill
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.7 s.124
    • /
    • pp.596-604
    • /
    • 2007
  • This article investigates the effects of geometric configuration on the vibro-acoustic characteristics of in-plane vibration of a thick annular disc. Disc thickness and outer radius for a given inner radius are selected as independent variables having reasonable ranges. Variations in structural eigensolutions for radial modes are investigated using pre-developed analytical method. Based on these data, far-field sound pressure distributions due to the modal vibrations for a given geometry are also calculated using an analytical solution. Modal sound powers and radiation efficiencies are calculated from the far-field sound pressure distributions and vibratory velocity distributions on the radial surfaces. Based on the results explained above, the geometric configuration that minimizes modal sound radiations in a given frequency range is determined. Finally sound power and radiation efficiency spectra for a unit harmonic force from the selected geometric configuration are obtained from structural and acoustic modal data using the modal expansion technique. Multi-modal sound radiations of the optimized disc that are obtained using proposed analytical methods are confirmed with numerical results. Using the procedure introduced in this article, sound radiation due to in-plane modes within a specific frequency range can be minimized by the disc geometry modifications in a comprehensive and convenient manner.

A Study on the Damage Range According to Leakage Scenarios in Natural Gas Pipeline of LNG Fueled Ship (LNG 추진선의 천연가스 배관에서 누출 시나리오에 따른 피해범위에 관한 연구)

  • Lee, Yoon-Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.4
    • /
    • pp.317-326
    • /
    • 2020
  • In this study, damages caused by flash fire, overpressure, and thermal radiation based on the sizes of leak holes were evaluated using the areal location of hazardous atmospheres when natural gas leaked owing to the damage of pipeline in a LNG fueled ship. In addition, environmental variables (wind speed, atmospheric temperature, and atmospheric stability) and process variables (pipe pressure and pipe length) were classified to analyze the damage impact ranges caused by various scenarios. From the results, the damage range caused by the environmental variables was the largest, followed by overpressure and thermal radiation. Additionally, for the process variables, regardless of the pressure, length, or size of the leak holes, the damage range attributed to flash fire was the most significant, and the damage range was high in the order of overpressure and thermal radiation, similar to the environmental variables. The larger the size of the leak holes, the higher the values of the environmental and process variables, and the higher the damage range caused by jet fire compared to the environmental variables.

The Electrical and Radiation Detection Properties of $Au/Cd_{1-x}Zn_x/Te(x=20%)/Au$ Structure ($Au/Cd_{1-x}Zn_x/Te(x=20%)/Au$ 구조의 전기적 특성 및 방사선 탐지 특성)

  • 최명진;왕진석
    • Electrical & Electronic Materials
    • /
    • v.10 no.1
    • /
    • pp.39-44
    • /
    • 1997
  • Bulk type radiation detector of Au/Cd$_{1-x}$ Zn$_{x}$Te(x=20%)/Au structure using Cd$_{1-x}$ Zn$_{x}$Te(x=20%) wafer(3x4xl mm$^{3}$) grown by high pressure Bridgman method has been developed. We etched wafer surfaces with 2% Br-methanol solution and coated gold thin film on the surfaces by electroless deposition method for 5 min. in 49/o HAuCI$_{3}$ 4H20 solution. Initial etch rates of Cd, Zn and Te were 46%, 12% and 42% respectively. After etched, the surface of wafer was slightly revealed to Te rich condition. The leakage current was increased with etch time, but it didn't exceed 3nA at 50volt. The thickness of Au film was about 100nm by Rutherford Backscattering Spectroscopy(RBS). The resolution were 6.7% for 22.1 keV photon from 109 $^{109}$ Cd and 8.2% for 59.5 keV photon from $^{241}$ Am. The radiation detector such as Au/Cd$_{1-x}$ Zn$_{x}$Te(x=20%)/Au structure was more effective to monitor the low energy gamma radiation.iation.

  • PDF

Housing Analysis for Ocean Radiation Detection (해양 방사선 탐지를 위한 하우징 분석)

  • Park, Gang-teak;Kim, Jong-Yeol;Jung, Hyun-kyu;Lee, Nam-ho;Hwang, Young-gwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.714-715
    • /
    • 2017
  • Much of the interest in ocean radiation detection has been heightened as a lot of radioactivity has leaked to the ocean due to the accident at the Fukushima nuclear power plant in Japan. In the study, MCNP simulation for radiation detection in the ocean was performed. Unlike in the air, the marine environment must ensure the stability of the sensor from water depth, temperature, pressure, and salinity. In the marine environment, too much radiation is shielded. Therefore, it is an object to select a housing with a low radiation shielding ratio.

  • PDF

Characteristics of Ocean Wave Radiation Patterns in a Dense Layer of Fluid (밀도층 유체에서 해양 방사파 패턴 특징)

  • Min, Eun-Hong;Choi, Ha-Yun;Kim, Young-Gyu;Paik, Kwang-Jun;Koo, Weon-Cheol
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.1
    • /
    • pp.92-97
    • /
    • 2019
  • The sea is stratified with water that has different densities because of pressure, temperature, and salinity. When conducting studies of internal waves in the ocean, the fluid is assumed to have layers that have discrete densities. This assumption is made because it is difficult to achieve layers that exhibit gradual changes in the density of the water. In this study, we used previous studies on ocean waves and their radiation issues in the density layer fluid to investigate the characteristics of internal waves in the ocean and their radiation patterns induced by a moving body in a stratified fluid. We also studied the difference in wave radiation between the density gradient layer and the discrete density layer. We found that the wave radiation patterns depended on the velocity of the moving body and the change in the density of the water. The crest apex shift phenomenon was observed in the density gradient in the layer of fluid.

An Analysis of Global Solar Radiation using the GWNU Solar Radiation Model and Automated Total Cloud Cover Instrument in Gangneung Region (강릉 지역에서 자동 전운량 장비와 GWNU 태양 복사 모델을 이용한 지표면 일사량 분석)

  • Park, Hye-In;Zo, Il-Sung;Kim, Bu-Yo;Jee, Joon-Bum;Lee, Kyu-Tae
    • Journal of the Korean earth science society
    • /
    • v.38 no.2
    • /
    • pp.129-140
    • /
    • 2017
  • Global solar radiation was calculated in this research using ground-base measurement data, meteorological satellite data, and GWNU (Gangneung-Wonju National University) solar radiation model. We also analyzed the accuracy of the GWNU model by comparing the observed solar radiation according to the total cloud cover. Our research was based on the global solar radiation of the GWNU radiation site in 2012, observation data such as temperature and pressure, humidity, aerosol, total ozone amount data from the Ozone Monitoring Instrument (OMI) sensor, and Skyview data used for evaluation of cloud mask and total cloud cover. On a clear day when the total cloud cover was 0 tenth, the calculated global solar radiations using the GWNU model had a high correlation coefficient of 0.98 compared with the observed solar radiation, but root mean square error (RMSE) was relatively high, i.e., $36.62Wm^{-2}$. The Skyview equipment was unable to determine the meteorological condition such as thin clouds, mist, and haze. On a cloudy day, regression equations were used for the radiation model to correct the effect of clouds. The correlation coefficient was 0.92, but the RMSE was high, i.e., $99.50Wm^{-2}$. For more accurate analysis, additional analysis of various elements including shielding of the direct radiation component and cloud optical thickness is required. The results of this study can be useful in the area where the global solar radiation is not observed by calculating the global solar radiation per minute or time.

An Analysis of the acoustic source and radiation acoustic field of centrifugal fans (원심팬 음원 및 방사 음향장 해석)

  • Jeon, Wan-Ho;Lee, Duck-Joo
    • 유체기계공업학회:학술대회논문집
    • /
    • 1998.12a
    • /
    • pp.97-104
    • /
    • 1998
  • The objective of this study is to understand the generation mechanism of sound and to develop a prediction method for the unsteady flow field and the acoustic pressure field of a centrifugal fan. Lowson's method is used to predict the acoustic pressure in a free field. A DVM(discrete vortex method) is used to model the centrifugal fan and to calculate the flow field. In order to compare the experimental data, a centrifugal fan and wedge introduced by Weidemann are used in the numerical calculation and the results are compared with the experimental data.

  • PDF

Dose Assessment According to Application of Carbon Fabric Blanket During Radiation Therapy of the Spine Metastasis Cancer (척추 전이암 환자의 방사선치료 시 Carbon Fabric Blanket 적용에 따른 선량평가)

  • Yang, Myung-Sic;Kim, Jung-Soo;Lee, Sun-Young;Kwon, Hyoung-Cheol
    • Journal of radiological science and technology
    • /
    • v.42 no.1
    • /
    • pp.61-66
    • /
    • 2019
  • The purpose of this study was to improve the unstable treatment posture by placing the Carbon fabric blanket on the couch which was used for the patient fixation for the unstable posture from the severe pain caused by the neuromuscular pressure of the spinal metastatic cancer patient and to analyze the dose difference caused by the energy loss of high energy radiation. Using a linear accelerator, a FC-65G was installed at a depth of 5 cm at a solid phantom at 6 MV and 10 MV energies. The SAD was 100 cm, Gantry angle was $0^{\circ}$, a Cotton and Carbon blanket with a thickness of 1 cm on the couch, The blankets were placed on the couch and the dose was measured according to field size. For the dose measurement, and the dose was measured at 100 MU each time, and the mean value was calculated by repeating the measurement three times in order to reduce the error. The results showed that the difference rate in dose between Carbon blanket and Cotton blanket was respectively -0.54% and -0.75% based on the absence of the blanket(Non). Therefore, it is considered that the use of Carbon fabric blanket, which reduces the patient's pain and does not affect the depth dose, may be useful during radiation therapy of the spine metastasis cancer.